Validation of Results of Smart Grid Protection through Self-Healing

Assumpção, Felipe Framil 29 October 2018 (has links)
This is a verification of the results of “Smart Grid Protection through Self-Healing” from the publication of Chathurika Chandraratne, et al., that proposes a protection solution for the smart grid. The paper used as reference has as the main focus on three different protections; directional overcurrent protection, overcurrent protection, and transformer protection, which are validated through ETAP software simulation of IEEE- 9 bus and 14 bus electrical power systems, the same used by the author. It was validated after repeated simulation, that just as intended, self-healing increases system agility, and it helped prevent false-tripping14 bus electrical power systems.
2

Analys av reläskyddsinställningar för jordfelsskydd

Edblom, Hampus January 2019 (has links)
Väl inställda reläskydd för ställverk är en nödvändighet för en personoch driftsäker anläggning. Rapportens mål är att undersöka om oriktade skydd med enbart signalering är tillräckligt för att skydda anläggningen som undersöks, och om riktade skydd har fördelen att förbättra felutpekning, minska risken för felaktig funktion eller minska funktionstiden. Anläggningen som undersökts är ett 6,3 kV industrinät med resistansjordning. I rapporten kontrolleras isolationsvärden och strömtoleranser för utrustningen, som sedan jämförs med beräknade spänningar och strömmar vid enfasiga jordfel. Rapporten beskriver också kort riktade skydd och dess funktioner i förhållande till frågeställningen om den eventuella fördelen med riktade skydd. Resultatet blev att överspänningar på grund av jordfel inte är något problem, men felströmmen genom nollpunktsmotståndet är för stor för enbart signalering. Vid stumma jordfel klarar nollpunktsmotståndet av att hantera felströmmen i 30 sekunder, varefter värmeutvecklingen resulterar i att nollpunktmotståndet kopplas bort och anläggningen blir isolerad från nollpunkten. Riktade skydd behövs enligt studien inte i en anläggning som denna. Detta är baserat på att kabelsträckorna är för korta för att orsaka kapacitiva strömmar tillräckligt stora för att felaktig funktion ska uppstå i oriktade skydd, och att nätstrukturen inte genererar strömmar i oväntade riktningar. Rapportens resultat visar att oriktade skydd är tillräckligt men att funktionen bör ställas om till bortkoppling av felande krets. / Well-adjusted relay protection for electrical substations is a necessity for personal safety and reliable operation. The aim of the report is to investigate whether non-directional protection with signaling alone is sufficient to protect the facility being investigated, and if directional protection has the advantage of improving fault detection, reducing the risk of unnecessary operation or reducing the function time. The facility under investigation is a 6.3 kV industrial network with resistance grounding. The report checks the insulation values and current tolerances for the equipment, which are then compared with calculated voltages and currents at single-phase earth faults. The report also briefly describes directional protection and its functions in relation to the issue of the potential benefit of directional protection. The result was that overvoltages due to earth faults are not a problem, but the fault current through the neutral point resistance is too large for signaling alone. In the case of earth faults with very low fault impedance, the neutral point resistance can handle the fault current for 30 seconds. After which the heat development results in the neutral point resistance being disconnected and the facility being isolated from the neutral point. According to the study, targeted protection is not needed in a facility like this. This is based on the fact that the cable paths are too short to cause capacitive currents large enough to cause unnecessary operation in non-directional protection, and that the network structure does not generate currents in unexpected directions. The result of the report shows that non-directional protection is sufficient, but that the operation function should be changed to tripping of faulty circuits
3

Analýza provozu mřížové sítě Brno – střed / Analysis of the operation of the lattice network Brno - střed

Frechová, Lucie January 2017 (has links)
The thesis shows the historical development of the South Moravian electricity system and the development of Brno´s network is discussed in more detail, especially the current form of the network from the outskirts of the city to its historical centre. The lattice network, as a subject of the analysis, is described in terms of the operation and reliability of the power supply. It also informs about the gradual development of the technology applied in the lattice network Brno-střed. The practical part performs the analysis of theoretical data and recorded data with respect to steady-state and faulty-state operation of the lattice network Brno-střed. The theoretical analysis is based on the simulation and calculation of the lattice network model in the software PAS DAISY Bizon and the monitored parameter is the transformers power load. In addition, the analysis of the real data includes the assessment of the difference average phase current values, as well as voltage, between the transformer phases. There is also the evaluation of the energy flow from the low voltage side to the high voltage side of the analysed network.