Spelling suggestions: "subject:"disinfectants. eng"" "subject:"disinfectant's. eng""
1 |
Suscetibilidade de microorganismos relacionados com a contaminação de alimentos em biofilme artificial e em suspensão frente a desinfetantes /Cabeça, Tatiane Karen. January 2006 (has links)
Orientador: Elisabeth Loshchagin Pizzolitto / Banca: Jonas Contiero / Banca: Cristina Paiva de Sousa / Resumo: Avaliou-se o perfil de suscetibilidade de Staphylococcus aureus ATCC 6538, Escherichia coli ATCC 25922 e Listeria monocytogenes ATCC 7644, em suspensão e em biofilme formado in vitro, frente à ação dos desinfetantes: ácido iodado, à base de biguanida, à base de quaternário de amônio, à base de ácido peracético e clorado, empregados comumente em indústrias alimentícias brasileiras. As técnicas de microscopia eletrônica de varredura e microbiológica de viabilidade celular foram utilizadas para esta pesquisa. Os resultados demonstraram que as células microbianas em suspensão foram suscetíveis a ação de todos os desinfetantes estudados, não apresentando células viáveis após 10 minutos de tratamento com os desinfetantes. O desinfetante clorado foi o mais eficaz na eliminação das células microbianas em biofilme, proporcionando baixos valores numéricos na contagem das células viáveis e poucas células aderidas à superfície do aço inoxidável após submetido ao tratamento de 10 minutos, enquanto o desinfetante à base de biguanida mostrou ser o menos eficaz na eliminação das células microbianas em biofilme após um tratamento de 10 minutos. A idade do biofilme em horas (24, 75, 120) não mostrou ser um fator influente na resistência das células microbianas aos desinfetantes testados. Comparando-se os resultados da suscetibilidade das células microbianas em suspensão e em biofilme, foi verificado que as células em biofilme são mais resistentes à ação dos desinfetantes. O conjunto dos resultados sugerem uma deficiência de todos os desinfetantes estudados na eliminação de S. aureus, E. coli e L. monocytogenes quando em biofilme. / Abstract: The susceptibility of Staphylococcus aureus ATCC 6538, Escherichia coli ATCC 25922 and Listeria monocytogenes ATCC 7644, in suspension and in biofilm formed in vitro, was studied against the action of disinfectants: iodine, biguanide, quaternary ammonium, peracetic acid and chlorine, commonly used in Brazilian food industries. The scanning electron microscopy and cellular viability techniques were used in this research. The results showed that the microbiological suspension cells were susceptible after 10 minutes of treatment with the disinfectants. The chlorine disinfectant was the most effective against microbiological cells in biofilm, showed low numbers of viable cells and few adhered cells on stainless steel surface after 10 minutes of treatment, while the biguanide disinfectant showed to be the least effective against microbiological cells in biofilm after 10 minutes of treatment. The biofilm age in hours (24, 72 and 120) didn't show to be an influential factor on resistance of microbiological cells to studied disinfectant. The comparison between the results of susceptibility of microbiological suspension cells and microbiological biofilm cells showed that the biofilm cells are more resistant to disinfectants action. The results suggest that the studied disinfectants could not eliminate S. aureus, E. coli and L. monocytogenes biofilms. / Mestre
|
2 |
Efeito da polimerização e desinfecção na resistência flexural e na topografia da superfície de resina acrílica /Oliveira, Derly Tescaro Narcizo de. January 2011 (has links)
Orientador: Francisco Antonio Bertoz / Coorientador: Maria Cristina Rosifini Alves Rezende / Banca: Marcelo Coelho Goiato / Banca: Kurt Faltin Júnior / Resumo: A ação dos produtos desinfetantes sobre as propriedades físico-químicas da resina acrílica norteia sua seleção para a higienização de aparelhos ortodônticos removíveis. Avaliou-se a resistência à fratura de resina acrílica ativada quimicamente após ciclagem em diferentes soluções desinfetantes. Foram confeccionados quarenta corpos de prova com resina acrílica autopolimerizável incolor (Clássico,Ind.&Com.Ltda./Brasil) utilizando-se matriz metálica retangular e circular, seguindo-se às técnicas de polimerização sob pressão úmida (imersão em água/n=20) e sob pressão seca (sem água/n=20) foram subdivididos em 4 grupos (n=5), conforme a solução utilizada para ciclagem: água destilada (Controle), bicarbonato de sódio, hipoclorito de sódio 1% e Corega®Tabs. A ciclagem consistiu em imersão em 100 ml da solução por 10 minutos três vezes ao dia e, em seguida, manutenção em recipiente fechado contendo saliva artificial a 37ºC. Este ciclo foi realizado durante 30 dias, trocando-se as soluções e a saliva a cada procedimento executado. Na sequência os espécimes foram submetidos ao ensaio de resistência flexural a três pontos foi utilizada máquina EMIC DL3000, à velocidade de 5mm/min, dispondo-se as amostras em suporte contendo dois apoios de sustentação, sendo aplicada força axial e equidistante aos dois outro pontos até a ruptura do corpo-de-prova. Os espécimes circulares foram levados para leitura em Microscópio de Força Atômica (AFM - V Nanoscope Veeco). Os resultados, submetidos à análise de variância (P<0,001 ) e o Teste de Tuckey (P<0,05) não apontaram diferenças significantes para a resistência flexural. Conclui-se que os métodos de polimerização e as soluções testadas não modificaram a resistência flexural... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The disinfectant products action on the physicochemical properties of acrylic resin guides its selection to the cleaning of removable orthodontic appliances. The fracture resistance of acrylic resin after cycling in different disinfectant solutions was evaluated. Forty specimens were made with colorless acrylic resin (Clássico, Ind. & Com.Ltda. / Brazil), using matrix, followed by the techniques of polymerization under wet pressure (immersion in water / n = 20) and dry pressure (no water / n = 20). The samples were divided into 4 groups (n = 5) as the solution used for cycling: distilled water (Control), sodium bicarbonate, sodium hypochlorite 1% and Corega®Tabs. The cycling consisted of immersion in 100 ml of solution for 10 minutes three times a day and then maintained in a closed container containing artificial saliva at 37 º C. These cycles were conducted during 30 days, changing the solutions and artificial saliva for each procedure performed. Latter, the specimens were submitted to surface analysis with Atomic Force Microscope (AFM - Veeco Nanoscope V). A machine, EMIC DL3000, was used for the three-point flexural strength test, speed of 5mm/min, providing the sample in medium containing two restraints support. After that axial force was applied and equidistant to the two other points to the body to break the specimens. The results were submitted to analysis of variace(P<0,001) and Tuckey Test (P<0,05) showed no significant differences in flexural strength test. The Atomic Force Microscopy analysis revealed less topographical roughness for the group Corega®Tabs. We conclude that the polymerization methods and solutions tested did not alter the flexural strength of the material studied except the comparation between... (Complete abstract click electronic access below) / Mestre
|
3 |
Efetividade de duas soluções desinfetantes e da irradiação por micro-ondas na desinfecção de próteses totais contaminadas com staphylococcus aureus resistente à meticilina (MRSA) /Altieri, Karen Tereza. January 2011 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Banca: Wander José da Silva / Resumo: Infecções causadas por bactérias resistentes a antibióticos são consideradas causa principal de mortalidade entre indivíduos imunocomprometidos e aproximadamente 50 % destas infecções tem sido relacionadas ao Staphylococcus aureus resistente à meticilina (MRSA). Estes microrganismos, quando presentes no biofilme das próteses dentarias, podem se dispersar nas secreções salivares e se disseminar pelo trato respiratório, causando pneumonia aspirativa. Assim, o presente estudo comparou a efetividade do hipoclorito de sódio a 1 %, digluconato de clorexidina a 2 % e irradiação por micro-ondas na desinfecção de próteses totais e corpos-de-prova circulares de resina acrílica para base de prótese (10 x 2 mm) contaminados com MRSA. Para isso, 36 próteses totais simuladas e 36 corpos-de-prova circulares foram confeccionados, esterilizados, inoculados com MRSA (107 ufc/mL) e incubados a 37 °C (por 24 e 48 h, respectivamente). Após incubação, próteses totais e corpos-de-prova foram distribuídos em 4 grupos de estudo (n=9): GC - não foi realizado nenhum método de desinfecção; GH - foi realizada a imersão em solução de hipoclorito de sódio a 1 % por 10 min; GCl -foi realizada a imersão em solução de digluconato de clorexidina a 2 % por 10 min; GM - foi realizada a desinfecção por irradiação em forno de micro-ondas a 650 W por 3 min. A efetividade dos procedimentos de desinfecção foi avaliada por meio de quantificação de colônias viáveis e da viabilidade celular. Para a quantificação de colônias viáveis, alíquotas de 25 μL da solução resultante das diluições seriadas (10-3 a 10-6 para GC e 100 a 10-3 para os grupos experimentais) foram semeadas em placas de Petri em duplicata e todas as placas foram incubadas por 48 h a 37 °C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por micro-ondas em longo prazo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Infections caused by antibiotic-resistant bacteria have been recognized as a predominant risk factor for mortality in elderly patients and approximately 50 % of these infections have been related to methicillin-resistant Staphylococcus aureus (MRSA). This microorganism, when present in the denture biofilm, can be released into the oral fluids and aspirated into the lower respiratory tract, thus causing infections such as aspiration pneumonia. The present study compared the efficacy of 1 % sodium hypochlorite, 2 % chlorhexidine gluconate, and microwave irradiation in disinfecting simulated complete dentures and circular specimens of acrylic resin denture base material (10 x 2 mm) contaminated with MRSA. Thirty-six dentures and 36 specimens were made, sterilized, inoculated with MRSA (107 cfu/mL), and incubated at 37 °C (for 24 and 48 h, respectively). After incubation, dentures and specimens were divided into 4 groups of study (n=9): PC - positive control, consisting of dentures and specimens not disinfected; HY - soaking in 1 % sodium hypochlorite solution for 10 min; CHL - soaking in 2 % chlorhexidine gluconate solution for 10 min; and MW - irradiating by microwave for 3 min at 650W. The effectiveness of the disinfection procedures was assessed cell viability (quantification of viable cells and XTT reduction method). For quantification procedures, aliquots of suspensions were plated at dilutions (10-3 to 10-6 for PC and 100 to 10-3 for experimental groups) and incubated (37 °C/48 h). Colonies counts (cfu/mL) were quantified. Dentures disinfected were also incubated at 37 °C for 7 days to verify the long-term effectiveness of disinfection. The viability of cells in each group of specimens was evaluated by XTT reduction method. The results showed that all dentures and specimens from the PC groups showed substantial microbial growth. No evidence of microbial growth was observed... (Complete abstract click electronic access below) / Mestre
|