• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dispersão de luz intraocular em diferentes idades e condições oculares

Bitencourt, Emilia Longhi 04 October 2012 (has links)
Avaliar a dispersão de luz intraocular em participantes com olhos saudáveis, moradores da Grande São Paulo e de San Miguel de Tucuman, Argentina, e pacientes que realizariam cirurgia refrativa (LASIK), utilizando o metodo psicofísico da Comparacão da Compensação presente no aparelho C-Quant (Oculus Optikgerate, Alemanha). Método: Foi utilizado o aparelho C-Quant, desenvolvido por Franssen, Coppens e van den Berg. (IOVS, 47:768,2006), disponivel comercialmente, para avaliar de maneira objetiva a dispersão de luz intraocular atraves de metodo psicofisico. Foram testados 261 voluntarios, de ambos os sexos, com idades variando entre 10 e 78 anos, divididos em tres grupos experimentais: grupo 1: n= 209, idade: 33,74 } 15,87 anos, moradores da Grande Sao Paulo; grupo 2: n=29, idade: 39,72}13,28 anos, moradores de San Miguel de Tucuman, Argentina; grupo 3: n=23, idade: 30,52}4,94 anos, moradores da Grande Sao Paulo e pacientes de cirurgia refrativa (LASIK). Cada voluntario realizou 6 testes, 3 em cada olho (olhos alternados), e os valores obtidos do parametro de dispersao foram comparados entre si e com as normas do equipamento. Os voluntarios do grupo 3 realizaram tres sessoes de testagem, antes da cirurgia, apos 60 dias da cirurgia e apos 120 dias da cirurgia. Resultados: Observou-se que, apesar da variacao entre respostas do mesmo participante e de diferentes participantes da mesma idade, nao houve significancia estatistica (ANOVA medidas pareadas, grupo 1: t=1,501, Wilcoxon, grupo 2: Z=-2,422, p-level 0,015) entre os dados, e em todos os grupos experimentais houve alta correlacao (grupo 1: Pearson: R=0,7101, grupo 2: Spearman = 0,942, grupo 3: Spearman = 0,958) entre olho direito e esquerdo. Comparando-se com as normas do aparelho atualizadas, nao foi encontrada diferenca estatistica para os tres grupos experimentais. No grupo 3, os resultados de dispersao pre-operatorio foram ligeiramente maiores que os obtidos com 60 e 120 dias de pos-operatorio, porem nao houve diferenca estatistica entre tais dados. Discussão: Os valores de dispersao de luz intraocular foram compativeis com as normas atualizadas do aparelho, o que se deve, principalmente, a grande variacao dos dados coletados, levando a um desvio padrao grande, que impossibilita qualquer diferenca estatistica. Observamos que entre os mais jovens (entre 10 e 20 anos), tais variacoes de valores de dispersao tambem ocorrem, levantando duvidas sobre a constancia da dispersao de luz nessa faixa etaria, fato predito na literatura. Observamos tambem uma diminuicao nos valores de dispersao no pos-operatorio a niveis normais, indicando recuperacao dos meios opticos apos a cirurgia. Nao foram observadas diferencas significativas entre a populacao brasileira e a argentina, nem entre participantes de olhos de cores diferentes, o que vai contra a literatura, que prediz valores maiores de dispersao para olhos claros / Purpose: Evaluate retinal straylight in healthy eyes of people living in Sao Paulo and San Miguel de Tucuman, Argentina, and in patients of refractive surgery (LASIK), using the psychophysical method Compensation Comparison as presented in the Oculus C-Quant (Oculus Optikgerate, Germany). Methods: Oculus C-Quant was used to access the retinal straylight, as developed by Franssen, Coppens and van den Berg (IOVS, 47:768,2006), using a psychophysical method to quantify retinal straylight. For this study 261 subjects were tested, both sexes, ages between 10 and 78 years old, arranged in three experimental groups: group 1, n=209, age: 33,74 } 15,87 years, all living in Sao Paulo; group 2: n=29, age: 39,72}13,28 years, living in San Miguel de Tucuman, Argentina; group 3: n=23, age: 30,52}4,94 years, living in Sao Paulo and all refractive surgery (LASIK) patients. Each subject performed the test 6 times, 3 times each eye (alternating eyes), and the straylight values were compared between measures on the same subject and with the updated standard norms of the C-Quant. Group 3 subjects were tested three times, one previously the refractive surgery, one 60 days after surgery and the last one 120 days after surgery. Results: As a result, there were no statistic differences between measures on the same subject and when comparing different subjects same age (Paired Measures ANOVA, group 1, t=1,501, Wilcoxon, group 2: Z=-2,422, p-level 0,015), and there were high correlation between right and left eyes for all three groups (group 1: Pearson: R=0,7101, group 2: Spearman = 0,942, group 3: Spearman = 0,958). The standard norms of the C-Quant were also compared with the straylight values for the subjects in all three groups, and also there was no statistical significance between them. At group 3, the pre-op results were slightly higher than the post-op (both 60 and 120 days), but no statistical difference was found. Discussion: The straylight values obtained were similar to those on the updated standard norms of the test, due mainly to data scatter and therefore high standard deviation values. Among the younger subjects (ages between 10 and 20 years) the straylight values also vary and didnt remain constant as predicted by literature. At group 3, straylight values on postop (60 and 120 days) were similar those from updated norms, indicating a recovery of the eye media after surgery. No statistical differences were found between Brazilian and Argentinean subjects, neither between dark and light eyes subjects, although the literature predicts higher straylight values for light eyes
2

Dispersão de luz intraocular em diferentes idades e condições oculares

Emilia Longhi Bitencourt 04 October 2012 (has links)
Avaliar a dispersão de luz intraocular em participantes com olhos saudáveis, moradores da Grande São Paulo e de San Miguel de Tucuman, Argentina, e pacientes que realizariam cirurgia refrativa (LASIK), utilizando o metodo psicofísico da Comparacão da Compensação presente no aparelho C-Quant (Oculus Optikgerate, Alemanha). Método: Foi utilizado o aparelho C-Quant, desenvolvido por Franssen, Coppens e van den Berg. (IOVS, 47:768,2006), disponivel comercialmente, para avaliar de maneira objetiva a dispersão de luz intraocular atraves de metodo psicofisico. Foram testados 261 voluntarios, de ambos os sexos, com idades variando entre 10 e 78 anos, divididos em tres grupos experimentais: grupo 1: n= 209, idade: 33,74 } 15,87 anos, moradores da Grande Sao Paulo; grupo 2: n=29, idade: 39,72}13,28 anos, moradores de San Miguel de Tucuman, Argentina; grupo 3: n=23, idade: 30,52}4,94 anos, moradores da Grande Sao Paulo e pacientes de cirurgia refrativa (LASIK). Cada voluntario realizou 6 testes, 3 em cada olho (olhos alternados), e os valores obtidos do parametro de dispersao foram comparados entre si e com as normas do equipamento. Os voluntarios do grupo 3 realizaram tres sessoes de testagem, antes da cirurgia, apos 60 dias da cirurgia e apos 120 dias da cirurgia. Resultados: Observou-se que, apesar da variacao entre respostas do mesmo participante e de diferentes participantes da mesma idade, nao houve significancia estatistica (ANOVA medidas pareadas, grupo 1: t=1,501, Wilcoxon, grupo 2: Z=-2,422, p-level 0,015) entre os dados, e em todos os grupos experimentais houve alta correlacao (grupo 1: Pearson: R=0,7101, grupo 2: Spearman = 0,942, grupo 3: Spearman = 0,958) entre olho direito e esquerdo. Comparando-se com as normas do aparelho atualizadas, nao foi encontrada diferenca estatistica para os tres grupos experimentais. No grupo 3, os resultados de dispersao pre-operatorio foram ligeiramente maiores que os obtidos com 60 e 120 dias de pos-operatorio, porem nao houve diferenca estatistica entre tais dados. Discussão: Os valores de dispersao de luz intraocular foram compativeis com as normas atualizadas do aparelho, o que se deve, principalmente, a grande variacao dos dados coletados, levando a um desvio padrao grande, que impossibilita qualquer diferenca estatistica. Observamos que entre os mais jovens (entre 10 e 20 anos), tais variacoes de valores de dispersao tambem ocorrem, levantando duvidas sobre a constancia da dispersao de luz nessa faixa etaria, fato predito na literatura. Observamos tambem uma diminuicao nos valores de dispersao no pos-operatorio a niveis normais, indicando recuperacao dos meios opticos apos a cirurgia. Nao foram observadas diferencas significativas entre a populacao brasileira e a argentina, nem entre participantes de olhos de cores diferentes, o que vai contra a literatura, que prediz valores maiores de dispersao para olhos claros / Purpose: Evaluate retinal straylight in healthy eyes of people living in Sao Paulo and San Miguel de Tucuman, Argentina, and in patients of refractive surgery (LASIK), using the psychophysical method Compensation Comparison as presented in the Oculus C-Quant (Oculus Optikgerate, Germany). Methods: Oculus C-Quant was used to access the retinal straylight, as developed by Franssen, Coppens and van den Berg (IOVS, 47:768,2006), using a psychophysical method to quantify retinal straylight. For this study 261 subjects were tested, both sexes, ages between 10 and 78 years old, arranged in three experimental groups: group 1, n=209, age: 33,74 } 15,87 years, all living in Sao Paulo; group 2: n=29, age: 39,72}13,28 years, living in San Miguel de Tucuman, Argentina; group 3: n=23, age: 30,52}4,94 years, living in Sao Paulo and all refractive surgery (LASIK) patients. Each subject performed the test 6 times, 3 times each eye (alternating eyes), and the straylight values were compared between measures on the same subject and with the updated standard norms of the C-Quant. Group 3 subjects were tested three times, one previously the refractive surgery, one 60 days after surgery and the last one 120 days after surgery. Results: As a result, there were no statistic differences between measures on the same subject and when comparing different subjects same age (Paired Measures ANOVA, group 1, t=1,501, Wilcoxon, group 2: Z=-2,422, p-level 0,015), and there were high correlation between right and left eyes for all three groups (group 1: Pearson: R=0,7101, group 2: Spearman = 0,942, group 3: Spearman = 0,958). The standard norms of the C-Quant were also compared with the straylight values for the subjects in all three groups, and also there was no statistical significance between them. At group 3, the pre-op results were slightly higher than the post-op (both 60 and 120 days), but no statistical difference was found. Discussion: The straylight values obtained were similar to those on the updated standard norms of the test, due mainly to data scatter and therefore high standard deviation values. Among the younger subjects (ages between 10 and 20 years) the straylight values also vary and didnt remain constant as predicted by literature. At group 3, straylight values on postop (60 and 120 days) were similar those from updated norms, indicating a recovery of the eye media after surgery. No statistical differences were found between Brazilian and Argentinean subjects, neither between dark and light eyes subjects, although the literature predicts higher straylight values for light eyes
3

Integração monolítica de guias de onda, curvas e junções em Y baseados em cristais fotônicos planares de silício e com baixas velocidades de grupo. / Monolithic integration of slow-light silicon photonic crystal slab waveguides, bends and Y-junctions.

Melo, Emerson Gonçalves de 10 October 2017 (has links)
A fotônica em silício é um campo de pesquisas emergente com grande potencial para contribuir com a resolução de alguns dos problemas tecnológicos da atualidade. O gargalo imposto por interconexões metálicas na expansão da taxa de transmissão de dados em sistemas de comunicação como os de computadores de alto desempenho talvez seja um dos maiores desafios a serem superados. A propagação de luz em baixas velocidades de grupo e com controle de dispersão é uma das linhas de pesquisa atuais nas quais se busca explorar de forma mais eficiente as propriedades ópticas do silício, e assim, aumentar a compatibilidade entre componentes fotônicos e a tecnologia CMOS (Complementary Metal- Oxide-Semiconductor) por meio da diminuição das dimensões e do consumo de energia de componentes ópticos ativos. Dessa forma, espera-se diminuir os custos de fabricação e viabilizar a produção em larga escala de dispositivos integrados optoeletrônicos, que poderiam ser utilizados em sistemas de comunicação de curtas distâncias e assim ampliar a largura de banda disponível. Investigações recentes têm demonstrado que a fabricação de dispositivos baseados em cristais fotônicos planares possui grande potencial para controlar simultaneamente a velocidade de grupo e a dispersão, além de permitir a redução do tamanho de elementos como curvas, divisores de potência e cavidades ressonantes devido ao efeito do confinamento dos campos através do bandgap fotônico. Dessa forma, esse trabalho aborda um estudo sobre a integração monolítica entre guias de onda, curvas de 60º e junções em Y que operam em baixas velocidades de grupo e com reduzida dispersão, construídos em cristais fotônicos planares formados por uma matriz periódica de furos em uma membrana de silício suspensa em ar. Essa investigação englobou atividades bastante intensivas, tanto de simulações por métodos numéricos, como de processos de fabricação dedicados à nanofotônica, assim como de caracterizações ópticas. Ao longo das discussões são identificados e analisados os mecanismos que afetaram de forma mais crítica a eficiência dos dispositivos propostos. Também foram avaliados os maiores problemas enfrentados nos processos de fabricação, e suas possíveis soluções foram apontadas. Os resultados demonstraram a possibilidade teórica de realizar tal integração de forma eficiente. O melhor entendimento sobre a relação entre a dispersão e os parâmetros geométricos dos guias de onda permitiram modelar curvas e divisores de potência que exibiram, respectivamente, larguras de banda em torno de 56 e 40 nm, cobrindo regiões do espectro com elevados índices de grupo. Foi possível fabricar cristais fotônicos com uma qualidade próxima das já reportadas na literatura sobre o tema e assim foram estabelecidas bases bastante sólidas para a fabricação de tais dispositivos localmente, sem a necessidade expressa de acessar centros de fabricação no exterior. / Silicon photonics is an emerging research field that has great potential to contribute to solving some of the technological problems nowadays. Maybe, one of the greatest challenges to be overcome is the bottleneck imposed by electrical interconnections in the expansion of the bandwidth of communication systems such as those of high performance computers. Slow light propagation in dispersionless media is a hot topic in the current research fields that seek to more efficiently explore the silicon optical properties, and thus, increase the compatibility between photonic components and CMOS technology by decreasing the footprint and power consumption of active optical components. This way, the manufacturing costs it is expected to be reduced by making the large-scale production of integrated optoelectronic devices feasible, and so, they could be used in short distance communication systems to expand the available bandwidth. Recent researches has also shown that photonic crystal slab waveguides are very promising to simultaneously control group velocity and devices dispersion, as well as in the reduction of the size of elements such as bends, power splitters and nanocavities due to the fields confinement through the photonic bandgap effect. Thus, this work addresses a study of the monolithic integration of slow light and dispersionless waveguides, 60º bends, and Y-junctions fabricated in air-bridge photonic crystal slabs formed by the drilling of a periodic array of air holes in a silicon membrane. The research was accomplished with intensive activities in numerical simulations, as well as in nanophotonic manufacturing processes, and optical characterizations. Throughout the discussions were identified and analyzed the mechanisms that more critically affected the devices efficiency. The major problems faced in the manufacturing processes were also evaluated, and their possible solutions were pointed out. The results demonstrated a theoretical possibility of performing such integration more efficiently. Having a better understandment about the relation between the photonic crystal waveguides geometrical parameters and their dispersion allowed the modeling of bends and power splitters which exhibited 3 dB bandwidths that covered, respectively, ranges around 56 and 40 nm, along spectral regions with very high group indices. It was possible to fabricate photonic crystals with a quality close to those already reported in the literature on this subject and thus, very solid bases were established for the manufacture of such devices locally, without the necessity of accessing manufacturing centers abroad.
4

Sequência didática sobre dispersão e difração da luz: confecção e utilização de um espectroscópio / Didactic sequence on dispersion and diffraction of light: confection and use of a spectroscope

Bruzadin, Felipe Rodrigues 27 September 2018 (has links)
Submitted by Felipe Rodrigues Bruzadin (felipebruzadin@hotmail.com) on 2018-11-14T15:47:02Z No. of bitstreams: 1 Dissertação Felipe Rodrigues Bruzadin.pdf: 1216866 bytes, checksum: 8f5b1b8d6f77b31f16363a41024cdedc (MD5) / Rejected by ALESSANDRA KUBA OSHIRO ASSUNÇÃO (alessandra@fct.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: - A ficha catalográfica está fora do padrão. Ela deve ser gerada através do link https://www.biblioteca.unesp.br/ficha/ Será gerado um pdf que deverá ser acrescentado ao trabalho - A ficha deve vir antes da folha de aprovação - Nos agradecimentos, de acordo com a portaria nº 206, de 04/09/2018, deverá constar a seguinte frase: O presente trabalho foi realizado com apoio da Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - Brasil (CAPES) - Código de Financiamento 001 Agradecemos a compreensão. on 2018-11-14T18:09:34Z (GMT) / Submitted by Felipe Rodrigues Bruzadin (felipebruzadin@hotmail.com) on 2018-11-14T18:58:24Z No. of bitstreams: 1 Dissertação Felipe Rodrigues Bruzadin.pdf: 1223088 bytes, checksum: 6154c5af3c3bf01a650eed314f51f20e (MD5) / Approved for entry into archive by ALESSANDRA KUBA OSHIRO ASSUNÇÃO (alessandra@fct.unesp.br) on 2018-11-14T19:19:22Z (GMT) No. of bitstreams: 1 bruzadin_fr_me_prud.pdf: 1223088 bytes, checksum: 6154c5af3c3bf01a650eed314f51f20e (MD5) / Made available in DSpace on 2018-11-14T19:19:22Z (GMT). No. of bitstreams: 1 bruzadin_fr_me_prud.pdf: 1223088 bytes, checksum: 6154c5af3c3bf01a650eed314f51f20e (MD5) Previous issue date: 2018-09-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta uma sequência didática onde são utilizadas ferramentas de informática e a experimentação como recursos metodológicos, com o intuito de contribuir com o ensino e a prática em sala de aula dos professores. Na sequência, aparece a ordem de como trabalhar a dispersão e a difração da luz, assim como as habilidades e competências necessárias, levando em conta os conhecimentos prévios dos alunos. Os resultados nos mostram que os alunos conseguiram entender a relação entre o espectro e a luz fornecida por diferentes lâmpadas assim como a participação deles nas atividades foi relevante. / This work presents a didactic sequence in which computer tools and experimentation are used as methodological resources, with the aim of contributing to teaching and practice in the teachers' classroom. In the sequence, appears the order of how work the scattering and diffraction of light, as well as the skills and competencies necessary, taking into account the prior knowledge of students. The results show us that students understand the relationship between the spectrum and the light supplied by different light bulbs as well as their participation in activities was relevant.
5

Integração monolítica de guias de onda, curvas e junções em Y baseados em cristais fotônicos planares de silício e com baixas velocidades de grupo. / Monolithic integration of slow-light silicon photonic crystal slab waveguides, bends and Y-junctions.

Emerson Gonçalves de Melo 10 October 2017 (has links)
A fotônica em silício é um campo de pesquisas emergente com grande potencial para contribuir com a resolução de alguns dos problemas tecnológicos da atualidade. O gargalo imposto por interconexões metálicas na expansão da taxa de transmissão de dados em sistemas de comunicação como os de computadores de alto desempenho talvez seja um dos maiores desafios a serem superados. A propagação de luz em baixas velocidades de grupo e com controle de dispersão é uma das linhas de pesquisa atuais nas quais se busca explorar de forma mais eficiente as propriedades ópticas do silício, e assim, aumentar a compatibilidade entre componentes fotônicos e a tecnologia CMOS (Complementary Metal- Oxide-Semiconductor) por meio da diminuição das dimensões e do consumo de energia de componentes ópticos ativos. Dessa forma, espera-se diminuir os custos de fabricação e viabilizar a produção em larga escala de dispositivos integrados optoeletrônicos, que poderiam ser utilizados em sistemas de comunicação de curtas distâncias e assim ampliar a largura de banda disponível. Investigações recentes têm demonstrado que a fabricação de dispositivos baseados em cristais fotônicos planares possui grande potencial para controlar simultaneamente a velocidade de grupo e a dispersão, além de permitir a redução do tamanho de elementos como curvas, divisores de potência e cavidades ressonantes devido ao efeito do confinamento dos campos através do bandgap fotônico. Dessa forma, esse trabalho aborda um estudo sobre a integração monolítica entre guias de onda, curvas de 60º e junções em Y que operam em baixas velocidades de grupo e com reduzida dispersão, construídos em cristais fotônicos planares formados por uma matriz periódica de furos em uma membrana de silício suspensa em ar. Essa investigação englobou atividades bastante intensivas, tanto de simulações por métodos numéricos, como de processos de fabricação dedicados à nanofotônica, assim como de caracterizações ópticas. Ao longo das discussões são identificados e analisados os mecanismos que afetaram de forma mais crítica a eficiência dos dispositivos propostos. Também foram avaliados os maiores problemas enfrentados nos processos de fabricação, e suas possíveis soluções foram apontadas. Os resultados demonstraram a possibilidade teórica de realizar tal integração de forma eficiente. O melhor entendimento sobre a relação entre a dispersão e os parâmetros geométricos dos guias de onda permitiram modelar curvas e divisores de potência que exibiram, respectivamente, larguras de banda em torno de 56 e 40 nm, cobrindo regiões do espectro com elevados índices de grupo. Foi possível fabricar cristais fotônicos com uma qualidade próxima das já reportadas na literatura sobre o tema e assim foram estabelecidas bases bastante sólidas para a fabricação de tais dispositivos localmente, sem a necessidade expressa de acessar centros de fabricação no exterior. / Silicon photonics is an emerging research field that has great potential to contribute to solving some of the technological problems nowadays. Maybe, one of the greatest challenges to be overcome is the bottleneck imposed by electrical interconnections in the expansion of the bandwidth of communication systems such as those of high performance computers. Slow light propagation in dispersionless media is a hot topic in the current research fields that seek to more efficiently explore the silicon optical properties, and thus, increase the compatibility between photonic components and CMOS technology by decreasing the footprint and power consumption of active optical components. This way, the manufacturing costs it is expected to be reduced by making the large-scale production of integrated optoelectronic devices feasible, and so, they could be used in short distance communication systems to expand the available bandwidth. Recent researches has also shown that photonic crystal slab waveguides are very promising to simultaneously control group velocity and devices dispersion, as well as in the reduction of the size of elements such as bends, power splitters and nanocavities due to the fields confinement through the photonic bandgap effect. Thus, this work addresses a study of the monolithic integration of slow light and dispersionless waveguides, 60º bends, and Y-junctions fabricated in air-bridge photonic crystal slabs formed by the drilling of a periodic array of air holes in a silicon membrane. The research was accomplished with intensive activities in numerical simulations, as well as in nanophotonic manufacturing processes, and optical characterizations. Throughout the discussions were identified and analyzed the mechanisms that more critically affected the devices efficiency. The major problems faced in the manufacturing processes were also evaluated, and their possible solutions were pointed out. The results demonstrated a theoretical possibility of performing such integration more efficiently. Having a better understandment about the relation between the photonic crystal waveguides geometrical parameters and their dispersion allowed the modeling of bends and power splitters which exhibited 3 dB bandwidths that covered, respectively, ranges around 56 and 40 nm, along spectral regions with very high group indices. It was possible to fabricate photonic crystals with a quality close to those already reported in the literature on this subject and thus, very solid bases were established for the manufacture of such devices locally, without the necessity of accessing manufacturing centers abroad.
6

Avaliação da dispersão de luz sobre a retina de pacientes com histórico de hanseníase

OLIVEIRA, Iraciane Rodrigues Nascimento January 2012 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-10-18T12:38:16Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoDispersaoLuz.pdf: 1108623 bytes, checksum: 61778de64ac4ed59a72b8a3d5c1700af (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-11-06T15:51:01Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoDispersaoLuz.pdf: 1108623 bytes, checksum: 61778de64ac4ed59a72b8a3d5c1700af (MD5) / Made available in DSpace on 2017-11-06T15:51:02Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoDispersaoLuz.pdf: 1108623 bytes, checksum: 61778de64ac4ed59a72b8a3d5c1700af (MD5) Previous issue date: 2012 / A hanseníase acomete as estruturas oculares e tem o potencial de prejudicar a passagem da luz através dos meios ópticos e prejudicar a formação da imagem na retina. Devido a importância da visão na vida do ser humano, a diminuição da qualidade de formação de imagem na retina, piora a qualidade de vida de pessoas que podem ter alterações sensoriais somestésicas e motoras. Este estudo transversal foi realizado com pacientes com história de hanseníase registrados no município de Governador Edison Lobão no Estado do Maranhão no período de agosto de 2011 a maio de 2012 e teve como principal objetivo avaliar o grau de dispersão da luz sobre a retina destes pacientes. Os dados foram colhidos através da utilização do aparelho C-Quant, o qual utiliza um procedimento psicofísico que permite quantificar a avaliação da dispersão da luz sobre a retina. Também foram utilizados questionários com o intuito de identificação as formas clínicas, grau de incapacidades, tempo de tratamento e dificuldade visual e comprometimento ocular dos pacientes envolvidos na pesquisa. Foram avaliados 50 olhos de pacientes com história clínica de hanseníase e foram comparados a 48 olhos de sujeitos controles. Não houve diferença entre os grupos estudados quanto à acuidade visual. Houve diferença estatística entre os valores de dispersão da luz entre os grupos controle e de pacientes com hanseníase (ANOVA de uma via, α = 0,05). Não houve diferença dos valores de dispersão de luz entre olhos de pacientes com diferentes formas clínicas da hanseníase. Vinte e sete (54%) olhos de pacientes com hanseníase apresentaram valores de dispersão da luz maiores acima de 99% da distribuição dos valores de dispersão da luz do grupo controle. Os valores da dispersão da luz em função da idade dos sujeitos controle ajustaram-se bem a um modelo preditivo, enquanto os valores dos pacientes com hanseníase não tiveram um bom ajuste ao modelo preditivo. A dispersão da luz em função do tempo de diagnóstico mostrou que os valores de dispersão da luz são maiores em pacientes recém-diagnosticados e que iniciaram o tratamento (2-6 meses) e em pacientes já tratados e com tempo de diagnósticos superior a 30 meses. Mesmo pacientes com acuidade visual normal tiveram alteração da dispersão da luz na retina e podem ter a qualidade de vida prejudicada no decorrer da vida. As alterações de dispersão da luz apresentados pelos pacientes com história de hanseníase devem ser devido ao comprometimento dos tecidos oculares devido a hanseníase, consequência de perdas de reações protetoras aos olhos devido perdas somestésicas e uso da terapia medicamentosa. / Leprosy affects the ocular structures e it has the potential to make deficits the image formation on the retina. As the vision has a very important function for the human being, the decrement of the image quality on the retina can get worst the quality of life of the leprosy patients, which already can have somesthesics and motor alterations. This study was performed with leprosy patients in the Edison Lobão city in the Maranhão state from August 2011 and May 2012. The main purpose was to evaluate the straylight in the eye of the leprosy patients. The data was collected using the equipment C-Quant that performs a psychophysical procedure to quantify the straylight in the retina. Questionnaires were used to get clinical history, incapacities, treatment duration and visual complains. It was evaluated 50 eyes from leprosy patients and they were compared to 48 eyes of control subjects. There were no differences between both groups in the comparison of visual acuity. There was statistical difference of the retinal straylight between the control and leprosy patients (one way ANOVA, α = 0.05). There was no difference between the retinal straylight between the clinical forms of leprosy. Twenty seven eyes of the leprosy patients had retinal straylight values above 99% of the retinal straylight distribution of the control group. The retinal straylight values of the control group fitted well to the predictive model to their variation as a function of the age, while the results obtained from leprosy patients had a low fit to that predictive model. The retinal straylight of the leprosy patients were higher in the begging of the treatment (2-6 months) and in cured patients with diagnosis time above to 30 months. Even in normal visual acuity patients, the retinal straylight values could be altered e they can have decreasing of the quality of life across the years. The changes of the retinal straylight showed by leprosy patients must be due alterations in the ocular media or tissues caused by leprosy, or loss of the protective reaction of the eyes due somesthesics losses or even use of drug therapy.

Page generated in 0.0809 seconds