• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • Tagged with
  • 33
  • 33
  • 24
  • 22
  • 19
  • 19
  • 17
  • 14
  • 12
  • 11
  • 11
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Retificador trifásico boost semi-controlado, com elevado fator de potência e controle por razão cíclica variável / Three-phase rectifier boost half-controlled, with high power factor and variable duty cycle control

Morais, Douglas Carvalho 02 March 2018 (has links)
Submitted by DOUGLAS CARVALHO MORAIS (morais.sccp.carvalho@gmail.com) on 2018-04-26T20:36:20Z No. of bitstreams: 1 RETIFICADOR TRIFÁSICO BOOST SEM PONTE DE DIODOS, COM ELEVADO FATOR DE POTÊNCIA E CONTROLE POR RAZÃO CÍCLICA VARIÁVEL.pdf: 3578931 bytes, checksum: 59462e5e8af8153b4c38efb1636c59de (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-04-27T12:43:58Z (GMT) No. of bitstreams: 1 morais_dc_me_ilha.pdf: 3578931 bytes, checksum: 59462e5e8af8153b4c38efb1636c59de (MD5) / Made available in DSpace on 2018-04-27T12:43:58Z (GMT). No. of bitstreams: 1 morais_dc_me_ilha.pdf: 3578931 bytes, checksum: 59462e5e8af8153b4c38efb1636c59de (MD5) Previous issue date: 2018-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho tem como objetivo a proposição de um retificador trifásico boost semi-controlado, com correção ativa do fator de potência, que faça uso de técnicas de controle de razão cíclica variável, visando reduzir o conteúdo harmônico de corrente em baixa frequência. O conversor proposto opera em modo de condução descontínua, desta forma, a corrente de entrada segue uma envoltória senoidal. Além disso, devido ao modo de condução, o conversor apresenta a entrada em condução da chave com corrente nula, diminuindo assim, as perdas por chaveamento. Inicialmente, são apresentados, estudos teóricos da topologia em questão e, por meio de gráficos e equações, verifica-se a distorção harmônica imposta devida à operação com razão cíclica constante. Funções que permitam a variação permanente da razão cíclica, durante um ciclo da rede, serão apresentadas. Tais funções possuem o intuito de minimizar a distorção harmônica da corrente de entrada, com foco principal na 5ª componente harmônica. Resultados de simulação demonstram eficácia das técnicas de controle por razão cíclica variável e apontam redução no conteúdo harmônico de corrente. Resultados experimentais demonstram conteúdo harmônico de corrente em torno de 18% para operação do conversor com razão cíclica constante. A utilização de razão cíclica variável proporciona uma redução no conteúdo harmônico de corrente para 13%, resultando em um aumento do fator de potência. / This work aims propose a three-phase rectifier boost half-controlled, with power factor correction, that makes use variable duty cycle control techniques, in order to reduce the harmonic content of current in low frequency. The proposed converter operates in a discontinuous current conduction mode, this way, the input current is naturally corrected. Moreover, due to the conduction mode, the converter presents entry in conduction of switch with null current, thus decreasing, the losses by switching. Initially, are presented theoretical studies of the topology in question and, through of graphs and equations, the harmonic distortion imposed by operation due constant duty cycle is verified. Functions that allow permanently the variation of duty cycle, during a network cycle, are presented. These functions have as main objective minimize the harmonic distortion in the input current, with focus in the 5th harmonic component. Simulation results demonstrate efficacy of techniques by variable duty cycle control and indicate a reducing of harmonic content of current. Experimental results demonstrate a reducing around 18% for operation with constant duty cycle. The use of variable duty cycle provides a reducing around 13%, resulting in an increase of the power factor.
32

Retificador híbrido trifásico com fator de potência unitário, alta densidade de potência e ampla faixa de regulação de tensão no barramento em corrente contínua para conexão em microrredes

Rodrigues, Danillo Borges 25 August 2016 (has links)
Este trabalho apresenta a análise e o desenvolvimento experimental de uma estrutura topológica de retificador híbrido trifásico que oferece as características operacionais de imposição de correntes de linha de entrada senoidais, de alto fator de potência, de reduzida distorção harmônica total de corrente e de fornecimento de um barramento CC com tensão regulada utilizando a inovadora técnica de Compensação Série de Tensão no Barramento CC tanto para condições normais de suprimento da rede elétrica como para condições de afundamentos temporários de tensão equilibrados e desequilibrados na rede CA. Para corroborar com a teoria exposta e com as análises de simulação computacional, um protótipo de 5 kW foi construído e ensaios experimentais realizados em laboratório permitiram demonstrar que para condições normais de suprimento da rede CA a solução proposta assegura distorções harmônicas de corrente na ordem de 2% e um fator de potência por fase próximo do valor unitário (0,996), além de ser capaz de regular e manter a tensão no barramento CC constante mesmo durante o transitório provocado por um degrau de carga de alta potência. Durante a ocorrência de afundamentos de tensão, a estrutura é capaz de regular a tensão do barramento CC no valor de referência estabelecido, assegurando elevado fator de potência mesmo durantes estes distúrbios da rede CA de alimentação. Destaca-se que estas características operacionais, além de serem alcançadas com os conversores chaveados que compõem a estrutura processando apenas uma parcela da potência total de saída, tornando o conjunto mais eficiente e robusto, fazem da estrutura proposta uma excelente alternativa para aplicações com elevados níveis de potência envolvendo a alimentação de cargas CC sensíveis aos distúrbios provocados pela rede CA e para aplicações que compreendem a compensação de oscilações de tensão devido às intermitências dos sistemas de microgeração que compõem as redes de distribuição em corrente contínua das microrredes. / This work presents the analysis and the experimental development of a topological structure of three-phase hybrid rectifier, which provides operational characteristics for imposing sinusoidal input line currents, with high power factor, low current total harmonic distortion and providing a DC bus with regulated voltage using the innovative technique of Series Voltage Compensation in the DC Bus for both normal conditions of mains power supply and for temporary sags for balanced and unbalanced voltage ac power supply conditions. In order to corroborate the exposed theory and with computational simulation analysis, a 5 kW prototype was assembled and experimental tests were conducted in laboratory. The results demonstrated that under normal conditions of AC mains supply the proposed solution ensures harmonic distortions about 2 % for the input AC currents and a power factor per phase approximately unitary (0.996). Moreover, the prototype can regulate and maintain the DC bus voltage in a constant value even during the transient caused by a high-power load step. During the occurrence of voltage sags, the structure can regulate the DC bus voltage in the established reference value, ensuring high power factor even during AC mains power supply disturbances. One can emphasize that these operational characteristics, in addition of being achieved with the switched converters that comprise the structure processing only an amount of the total output power, was observed that the whole assembly is more efficient and robust. The proposed structure is an excellent alternative for supplying high power DC loads sensitive to disturbances caused by AC mains and for applications involving voltage oscillations compensation due to intermittences of microgeneration systems that are connected to DC distribution of microgrids. / Tese (Doutorado)
33

ESTIMAÇÃO PROBABILÍSTICA DO NÍVEL DE DISTORÇÃO HARMÔNICA TOTAL DE TENSÃO EM REDES DE DISTRIBUIÇÃO SECUNDÁRIAS COM GERAÇÃO DISTRIBUÍDA FOTOVOLTAICA / PROBABILISTIC ESTIMATION OF THE LEVEL OF DISTORTION TOTAL HARMONIC VOLTAGE IN DISTRIBUTION NETWORKS SECONDARY WITH PHOTOVOLTAIC DISTRIBUTED GENERATION

SILVA, Elson Natanael Moreira 10 February 2017 (has links)
Submitted by Maria Aparecida (cidazen@gmail.com) on 2017-04-17T13:14:17Z No. of bitstreams: 1 Elson Moreira.pdf: 7883984 bytes, checksum: cf59b3b0b24a249a7fd9e2390b7f16de (MD5) / Made available in DSpace on 2017-04-17T13:14:17Z (GMT). No. of bitstreams: 1 Elson Moreira.pdf: 7883984 bytes, checksum: cf59b3b0b24a249a7fd9e2390b7f16de (MD5) Previous issue date: 2017-02-10 / CNPQ / A problem of electric power quality that always affects the consumers of the distribution network are the harmonic distortions. Harmonic distortions arise from the presence of socalled harmonic sources, which are nonlinear equipment, i.e., equipment in which the voltage waveform differs from the current. Such equipment injects harmonic currents in the network generating distortions in the voltage waveform. Nowadays, the number of these equipment in the electrical network has increased considerably. However, the increasing use of such equipment over the network makes systems more vulnerable and prone to quality problems in the supply of electricity to consumers. In addition, it is important to note that in the current scenario, the generation of electricity from renewable sources, connected in the secondary distribution network, is increasing rapidly. This is mainly due to shortage and high costs of fossil fuels. In this context, the Photovoltaic Distributed Generation (PVDG), that uses the sun as a primary source for electric energy generation, is the main technology of renewable generation installed in distribution network. However, the PVDG is a potential source of harmonics, because the interface of the PVDG with the CA network is carried out by a CC/CA inverter, that is a highly nonlinear equipment. Thus, the electrical power quality problems associated with harmonic distortion in distribution networks tend to increase and be very frequent. One of the main indicators of harmonic distortion is the total harmonic distortion of voltage ( ) used by distribution utilities to limit the levels of harmonic distortion present in the electrical network. In the literature there are several deterministic techniques to estimate . These techniques have the disadvantage of not considering the uncertainties present in the electric network, such as: change in the network configuration, load variation, intermittence of the power injected by renewable distributed generation. Therefore, in order to provide a more accurate assessment of the harmonic distortions, this dissertation has as main objective to develop a probabilistic methodology to estimate the level of in secondary distribution networks considering the uncertainties present in the network and PVDG connected along the network. The methodology proposed in this dissertation is based on the combination of the following techniques: three-phase harmonic power flow in phase coordinate via method sum of admittance, point estimate method and series expansion of Gram-Charlier. The validation of the methodology was performed using the Monte Carlo Simulation. The methodology was tested in European secondary distribution network with 906 nodes of 416 V. The results were obtained by performing two case studies: without the presence of PVDG and with the PVDG connection. For the case studies, the following statistics for nodal were estimated: mean value, standard deviation and the 95% percentile. The results showed that the probabilistic estimation of is more complete, since it shows the variation of due to the uncertainties associated with harmonic sources and electric network. In addition, they show that the connection of PV-DG in the electric network significantly affects the levels of of the electric network. / Um problema de qualidade de energia elétrica que afeta os consumidores da rede de distribuição secundária são as distorções harmônicas. As distorções harmônicas são provenientes da presença das chamadas fontes de harmônicas que são equipamentos de características não-lineares, ou seja, equipamentos em que a forma de onda da tensão difere da de corrente. Tais equipamentos injetam correntes harmônicas na rede produzindo, portanto distorções na forma de onda da tensão. Nos dias atuais, a quantidade desses equipamentos na rede elétrica tem aumentado consideravelmente. Porém, o uso crescente desse tipo de equipamento ao longo da rede torna os sistemas mais vulneráveis e propensos a apresentarem problemas de qualidade no fornecimento de energia elétrica aos consumidores. Além disso, é importante destacar que no cenário atual, a geração de energia elétrica a partir de fontes renováveis, conectada na rede de distribuição secundária, está aumentando rapidamente. Isso se deve principalmente devido a escassez e altos custos dos combustíveis fosseis. Neste contexto, a Geração Distribuída Fotovoltaica (GDFV), que utiliza o sol como fonte primária para geração de energia elétrica, é a principal tecnologia de geração renovável instalada na rede de distribuição no Brasil. Contudo, a GDFV é uma potencial fonte de harmônica, pois a interface da GDFV com a rede CA é realizada por um inversor CC/CA, que é um equipamento altamente não-linear. Desde modo, os problemas de qualidade de energia elétrica associados à distorção harmônica nas redes de distribuição tendem a aumentar e a serem bem frequentes nos consumidores da rede de distribuição secundárias. Um dos principais indicadores de distorção harmônica é a distorção harmônica total de tensão ( do inglês “Total Harmonic Distortion of Voltage”) utilizada pelas concessionárias de energia elétrica para quantificar os níveis de distorção harmônica presentes na rede elétrica. Na literatura técnica existem várias técnicas determinísticas para estimar a . Essas técnicas possuem a desvantagem de não considerar as incertezas presentes na rede elétrica, tais como: mudança na configuração da rede, variação de carga e intermitência da potência injetada pela geração distribuída renovável. Portanto, a fim de fornecer uma avaliação mais precisa das distorções harmônicas, este trabalho tem como principal objetivo desenvolver uma metodologia probabilística para estimar o nível de em redes de distribuição secundária considerando as incertezas presentes na rede e na GDFV conectada ao longo da rede. A metodologia proposta nesta dissertação se baseia na combinação das seguintes técnicas: fluxo de potência harmônico trifásico em coordenadas de fase via método de soma de admitância, método de estimação por pontos e expansão em série de Gram-Charlier. Além disso, a validação da metodologia foi realizada utilizando a Simulação Monte Carlo. A metodologia desenvolvida foi testada na rede de distribuição secundária europeia com 906 nós de 416 V. Os resultados foram obtidos realizando dois casos de estudos: sem a presença de GDFV e com a conexão de GDFV. Para ambos os casos de estudo as seguintes estatísticas do nodal foram estimadas: valor médio, desvio padrão e o percentil de 95%. Os resultados demonstraram que a estimação probabilística da é mais completa, pois mostra a variação da devido às incertezas associadas com as fontes de harmônicas e as da rede elétrica. Os resultados também mostram que a conexão da GDFV afeta significativamente os níveis de da rede elétrica

Page generated in 0.0407 seconds