Proposta de norma de conexão de fontes de geração distribuída à rede de baixa tensão da concessionária / Proposal of standard connection for distributed generation sources on low voltage network of the utility

Donadon, Antonio Roberto 16 August 2018 (has links)
Orientadores: João Carlos Camargo, Ennio Peres da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-16T18:59:48Z (GMT). No. of bitstreams: 1 Donadon_AntonioRoberto_M.pdf: 1117953 bytes, checksum: 01a83592806648f889aea2c35b02b7c6 (MD5) Previous issue date: 2010 / Resumo: O objetivo do trabalho foi propor uma minuta de norma de conexão de geradores ou pequenos sistemas de geração distribuída em baixa tensão (GDBT) com potência menor ou igual a 75 kW monofásico ou trifásico com conversão estática em paralelo com a rede de distribuição secundária da concessionária local. Para atingir esse objetivo realizou-se um levantamento do estado da arte em matéria de normas de conexão em países onde esse assunto já se encontra em situação mais avançada bem como da incipiente legislação brasileira sobre o assunto. Baseado nisso e nos os dados obtidos dos testes de operação das fontes estudadas no projeto de pesquisa Implantação de Geração Distribuída Junto à Rede de Distribuição relacionados aos aspectos de qualidade de energia e segurança chegou-se a um elenco de tópicos relevantes para a construção de uma norma. O trabalho concluiu também que fontes de GDBT que possuam conversores estáticos que atendam aos requisitos de segurança e qualidade de energia da norma internacional IEEE 1547 poderiam ser conectadas à rede de distribuição da concessionária / Abstract: The objective was to propose a draft standard for connecting small single-phase or three phase generators with rated power lower than or equal to 75 kW with static converter in parallel with low voltage utility grid (GDBT). To reach this goal it was carried out a survey of the state of the art in connection standards in countries where this matter is already more advanced state as well as the incipient Brazilian legislation on this matter. Based on this survey and the data obtained from operation tests of power sources studied in the R&D project Implementation of Distributed Generation in the Utility Grid related to safety and power quality was possible to obtain a range of relevant topics to build a connection standard. The study also concluded that GDBT power sources equipped with static converters that meet the international standard IEEE 1547 safety and power quality requirements could be connected to the utility grid / Mestrado / Engenharia Mecanica / Mestre em Planejamento de Sistemas Energéticos
2

Conversor eletrônico de potência trifásico para sistema fotovoltaico conectado à rede elétrica / Three-phase power converter for grid-connected photovoltaic system

Villalva, Marcelo Gradella, 1978- 17 August 2018 (has links)
Orientador: Ernesto Ruppert Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-17T05:47:06Z (GMT). No. of bitstreams: 1 Villalva_MarceloGradella_D.pdf: 10773240 bytes, checksum: aeccba84d675a257bed00100b3d011cb (MD5) Previous issue date: 2010 / Resumo: Este trabalho é uma contribuição ao estudo de conversores eletrônicos para sistemas fotovoltaicos de geração distribuída de energia elétrica. O objetivo principal é apresentar o desenvolvimento e os resultados de um conversor eletrônico trifásico para a conexão de um conjunto de painéis solares fotovoltaicos à rede elétrica de baixa tensão. São apresentados resultados experimentais e estudos teóricos sobre a modelagem e a simulação de dispositivos fotovoltaicos, a regulação da tensão fotovoltaica, o rastreamento da máxima potência e a modelagem e o controle de um conversor eletrônico de dois estágios / Abstract: This work is a contribution to the study of power converters for photovoltaic distributed generation systems. The main objective is to present the development and results of a threephase power converter for a grid-connected photovoltaic plant. The work presents experimental results and theoretical studies on the modeling and simulation of photovoltaic devices, regulation of the photovoltaic voltage, maximum power point tracking, and the modeling and control of a two-stage grid-connected power converter / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
3

Estudo de técnicas de controle de fluxo de potência e de gerenciamento de ilhamento em sistemas de geração distribuída com interfaces eletrônicas de potência para conexão com a rede elétrica / Power flow control and islanding management in small power distributed generation systems using power electronics interface for the connection with the grid

Moreno Martinez, Rodolfo Manuel 15 August 2018 (has links)
Orientadores: José Antenor Pomilio, Luiz Carlos Pereira da Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T23:21:44Z (GMT). No. of bitstreams: 1 MorenoMartinez_RodolfoManuel_D.pdf: 3227759 bytes, checksum: b66cea18c73d62eee160d3b5cf012d1f (MD5) Previous issue date: 2010 / Resumo: O presente trabalho estuda problemas do controle de fluxo de potência e de gestão de ilhamento em sistemas de geração distribuída de pequeno porte nos quais a interface com a rede elétrica sejam feitas por meio de conversores eletrônicos de potência. O sistema completo apresenta conversor "on-line", no qual a potência produzida localmente é totalmente processada pelo conversor, juntamente com uma estrutura "interativa com a rede", na qual o conversor opera para manter determinados padrões de desempenho sem, no entanto, processar potência ativa. É também focalizado o problema de qualidade da energia elétrica, analisando-se maneiras de operar os conversores de modo a mitigar problemas relacionados a harmônicos. Além de estudos de modelagem e simulação, avança-se na implementação experimental de algumas das técnicas analisadas / Abstract: This work studies problems of power flow control and islanding management in small power distributed generation systems in which the interface with the grid is made through electronic power converters. The complete system has "on-line" behavior, in which the power produced locally is fully processed by the converter, and also a structure "line-interactive," in which the converter operates to maintain certain performance standards without, however, process active power. It is also focused on the problem of power quality, analyzing ways to operate the converter in order to mitigate problems related to harmonics. In addition to modeling and simulation, some experimental implementation of the proposed techniques are realized / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
4

Microinversor monofásico para sistema solar fotovoltaico conectado à rede elétrica / Single-phase micro-inverter for grid-connected photovoltaic systems

Gazoli, Jonas Rafael 08 October 2011 (has links)
Orientadores: Ernesto Ruppert Filho, Marcelo Gradella Villalva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T00:52:44Z (GMT). No. of bitstreams: 1 Gazoli_JonasRafael_M.pdf: 7156744 bytes, checksum: 8382e373834c6001d3a70cd31e6f291f (MD5) Previous issue date: 2011 / Resumo: Este trabalho apresenta uma contribuição à pesquisa e ao desenvolvimento de microinversores monofásicos para sistemas fotovoltaicos de energia solar conectados à rede elétrica de baixa tensão. O objetivo principal da pesquisa é apresentar o projeto, a construção e os resultados experimentais de um microinversor eletrônico que processa a energia proveniente de um painel fotovoltaico e faz a conexão deste dispositivo com a rede El. São apresentados estudos teóricos e simulações sobre painéis fotovoltaicos, sobre a modelagem e o controle de conversores eletrônicos e sobre o algoritmo de rastreamento do ponto de máxima potência. São apresentados resultados experimentais obtidos com um microinversor experimental desenvolvido em laboratório, constituído de dois estágios de conversão (CC-CC e CC-CA) / Abstract: This thesis presents a contribution to research and development of single-phase micro-inverters for low voltage grid-connected photovoltaic systems. The main goal of this research is to present the project, the development and experimental results of an electronic micro-inverter that processes the energy from a photovoltaic panel and connects this device to the main grid. Theoretical studies and simulations on photovoltaic panels are shown, as the modeling and control of the electronic converters and the maximum power point tracking algorithm. Results with an experimental microinverter consisting of two stages (DC-DC and DC-AC) are also shown / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
5

Sistema monofásico de geração distribuída baseado em inversor multinível / Single-phase distributed generation system based on asymmetrical cascaded multilevel inverter

Pimentel, Sergio Pires 19 August 2018 (has links)
Orientador: José Antenor Pomilio / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T00:56:56Z (GMT). No. of bitstreams: 1 Pimentel_SergioPires_D.pdf: 7198764 bytes, checksum: 8dbb9a95a5a5374423051cba1bcfc1be (MD5) Previous issue date: 2011 / Resumo: Este trabalho aborda as características que envolvem o gerenciamento da operação de um sistema monofásico de geração distribuída. Embora tais características possam ser expandidas para sistemas trifásicos e de potência elevada, o sistema proposto está relacionado com aplicações de geração distribuída em baixa tensão ou naquelas que envolvam consumidores residenciais. O funcionamento do sistema proposto é baseado em um conversor eletrônico de potência elaborado a partir da estrutura multinível na topologia cascata assimétrica de 19 níveis. Nesta topologia, as tensões dos barramentos CC devem ser isoladas e desiguais entre si. Tal condição permite o envolvimento, nos barramentos CC do inversor, de múltiplas ou diferentes fontes alternativas de energia elétrica tais como sistemas fotovoltaicos, sistemas de células a combustível ou sistemas eólicos associados com conversores CC/CC. Com o sistema em operação, busca-se uma injeção apenas de potência ativa no sistema de distribuição alimentador e um fornecimento ininterrupto de energia elétrica para uma carga local mesmo quando nesta predominar características não-lineares de alimentação. Assim, de acordo com os seus objetivos, o sistema proposto opera de forma contínua e intercalada entre os modos ilhado e compartilhado. Detalhes sobre tais modos de operação e suas respectivas transições são apresentadas. As transições envolvem a detecção de ilhamento e o êxito no sincronismo. Em função disso, é apresentado um método ativo de detecção de condições de ilhamento. Tal método representa a adaptação de um método ativo já existente (AFDPF) aos requisitos de operação do sistema proposto neste trabalho. Justificativas e detalhes dessa adaptação do método ativo AFDPF são apresentados. Com relação à outra transição, um método de sincronismo baseado em técnicas PLL é apresentado. Tal método de sincronismo atende os requisitos estabelecidos em IEEE Std 1547-2003, diminuindo os impactos de uma possível religação com o sistema de distribuição. Para permitir um melhor funcionamento sob diferentes requisitos, também são descritas as etapas que envolvem os métodos de projeto dos controladores adotados: controlador PI de corrente de saída; controlador PI de potência média injetada; e controlador P+Ress de tensão na carga. Em especial, é apresentada uma nova metodologia de projeto do controlador proporcional e ressonante (P+Ress) de tensão baseada na sua resposta em malha fechada observada no domínio do tempo, em contrapartida ao seu método clássico de projeto baseado no domínio da freqüência. Um modelo matemático para simulações computacionais e um protótipo experimental utilizando o DSP TMS320F2812 foram considerados. Resultados de simulações computacionais e experimentais são comparados e permitem a verificação do comportamento do sistema proposto sob condições normais e anormais de operação / Abstract: This work regards the issues related to the operation management of a single-phase distributed generation system. Although these issues can be applied three-phase systems and high power systems, the proposed system is related to low voltage distributed generation applications or related to residential consumers. The operation of the single-phase proposed system is based on an utility-interactive power electronics converter which is composed by an asymmetrical cascaded multilevel inverter. This topology is able to create an output signal with up to 19 levels and it is supplied by DC voltage power sources that must be isolated and unequal from each other. By this demand it is possible to combine multiple and/or different alternative DC voltage power supplies as photovoltaic, fuel cells or wind energy systems into the DC buses of the single-phase multilevel inverter. During the operation of the proposed system, an injection of only active power into the grid utility and an uninterrupted load supply are achieved even when the local load (or group of local loads) has predominant nonlinear characteristics. For those reasons the proposed system operates continuously and alternately between two operation modes: grid-connected mode and stand-alone mode. Details about them and its transitions are also presented. The transitions are related to a correct detection of islanding situations and also to an effective synchronization method. The islanding detection is achieved by adaptations on an already known active method (AFDPF) to accomplish the project's goals. The reasons and details about these adaptations are presented. Furthermore the synchronization method is described and it is based on PLL techniques. Both transition methods meet the IEEE Std 1547-2003 requirements and it decreases the impacts from the proposed system into grid utility. To guarantee a suitable operating under several conditions, a wide range of operation points can be found by using the design methods described to each proposed controller: PI output current controller; PI injected active power controller; and a P+Ress load voltage controller. In highlights it is proposed a new design method to proportional and resonant controller (P+Ress) based on its closed-loop time response, instead of the classical method based on its open-loop frequency response. A mathematical model for simulations and an experimental low power prototype based on DSP TMS320F2812 have been considered. Simulation and experimental results are compared and they allow examining the performance of the proposed system operating under normal and abnormal conditions / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
6

Desempenho de geradores distribuídos durante curtos-circuitos considerando requisitos de suportabilidade a afundamentos de tensão = Distributed generators performance during short-circuits considering fault ride-through requirements / Distributed generators performance during short-circuits considering fault ride-through requirements

Silva, Rafael Schincariol da, 1983- 08 March 2012 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T00:53:15Z (GMT). No. of bitstreams: 1 Silva_RafaelSchincariolda_M.pdf: 3440136 bytes, checksum: 042a03fcb6272566cfc1c79d07478e1c (MD5) Previous issue date: 2012 / Resumo: O aumento da penetração de geradores em redes de distribuição de energia elétrica além de diversificar a matriz elétrica proporciona benefícios técnicos e econômicos. Contudo, também levanta preocupações relativas à confiabilidade no suprimento de energia elétrica. Para plantas eólicas conectadas na média e alta tensão são estabelecidos requisitos de "Fault Ride-Through" que determinam que os geradores devem permanecer conectados à rede durante perturbações com afundamentos de tensão e, em alguns casos, fornecer reativos para o reestabelecimento da tensão terminal. Porém, implementar tais requisitos para geradores na baixa tensão não é trivial. Na ocorrência de grandes perturbações os geradores distribuídos devem obrigatoriamente ser desconectados em casos de ilhamento, caso contrário a segurança de pessoas e equipamentos é colocada em risco e a qualidade de energia fornecida não é garantida. Ainda, durante curtos-circuitos os geradores contribuem para ao aumento das correntes de falta e os esquemas de proteção podem sofrer impactos na seletividade e coordenação. Por isso, para atender o requisito de "Fault Ride- Through" seria necessário além de manter os geradores conectados rever os esquemas de proteção de sobrecorrente, sendo necessários estudos dos impactos desta iniciativa e a análise do comportamento dos principais tipos de geradores distribuídos na ocorrência de curtos-circuitos. Nesta dissertação de mestrado, uma rede de distribuição com geradores distribuídos foi analisada através do estudo de sucessivas simulações de transitórios eletromagnéticos. O comportamento de três tipos de geradores distribuídos na ocorrência de curtos-circuitos foi investigado por meio de estudos de estabilidade, da análise das características de afundamentos de tensão e do suporte de reativos. Os geradores síncronos se mostraram com maior capacidade de suportarem faltas temporárias na rede. Os impactos do aumento das correntes de falta nas proteções contra sobrecorrente e da não desconexão do gerador do sistema ilhado também foram analisados. Os resultados mostraram que a presença de geradores distribuídos pode causar problemas na seletividade e na coordenação da proteção, alem de deteriorar o comportamento transitório de geradores ilhados / Abstract: The increase of distributed generation penetration in distribution systems not only helps to diversify the electrical matrix but also brings both technical and economic benefits. Yet, it also raises worries related to energy supply reliability. For wind power plants into the medium and high voltage networks there are the grid codes for "Fault Ride-Through" which stands that wind generators ought to ride a fault with voltage sag and, in some cases, provide reactive power for the terminal voltage restoration. However, implementing such requisites for low voltage connected generators is not a trivial task, as under great perturbations the distributed generators are required to be disconnected from the grid if an islanding situation occurs. Otherwise, people and equipment security would be at risk and the quality of the supplied power cannot be guaranteed. Besides, during short-circuits generators contribute to the increased fault currents along the grid and because of that the protection schemes should experience loss of selectivity and coordination. So, meeting the fault ride-through requirement demand a review of the anti-islanding schemes in order to permit generator islanding, as well as review the protection schemes to guarantee selectivity and coordination. Therefore, studies about the impacts of this initiative are necessary as well as the main generators behavior analysis under short-circuits. In this dissertation, a distribution network was analyzed through successive electromagnetic transient simulations. The behavior of three types of distributed generators under shortcircuits was investigated by stability studies, voltage sag characteristics and reactive power support. Synchronous generators showed to present the best capability to ride through temporary faults on the grid. The impacts on overcurrent protection of increased shortcircuit currents due to the distributed generators and impacts of not disconnecting the generators during islanding situations were also analyzed. The outcomes showed that keeping distributed generators connected might lead to problems on the protection selectivity and coordination and deteriorate the transient behavior of generators / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
7

Multifuncionalidade de conversores eletrônicos de potência utilizados em microrredes inteligentes / Multifunctionality of power electronic converters applied to smart microgrids

Bonaldo, Jakson Paulo, 1985- 05 August 2015 (has links)
Orientadores: José Antenor Pomilio, Helmo Kelis Morales Paredes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T15:42:43Z (GMT). No. of bitstreams: 1 Bonaldo_JaksonPaulo_D.pdf: 17560251 bytes, checksum: 58f533494814fb77a6b0736b27fa4d61 (MD5) Previous issue date: 2015 / Resumo: Esta tese apresenta contribuições para a utilização multifuncional de conversores eletrônicos de potência aplicados à geração distribuída de energia. Através das técnicas propostas, o conversor, que convencionalmente atua como interface entre fontes alternativas de energia e a rede elétrica, agrega funcionalidades relacionadas ao tratamento de problemas de qualidade da energia elétrica, passando a operar, também, como um filtro ativo de potência. As estratégias desenvolvidas para viabilizar o uso multifuncional do conversor têm como base a corrente que flui por uma carga local conectada ao ponto de acoplamento do conversor. Através da decomposição da corrente da carga em parcelas ortogonais relacionadas aos distúrbios de qualidade de energia, podem ser escolhidos os distúrbios a serem compensados, bem como o grau de compensação a ser aplicado. Entretanto, devido ao comportamento intermitente e imprevisível das cargas e das fontes alternativas de energia, a capacidade de potência ou corrente do conversor pode ser insuficiente para realizar sua função primária, isto é, a injeção da energia produzida pela fonte local, simultaneamente à compensação de distúrbios de qualidade de energia. Por isso, são desenvolvidas estratégias para limitar a potência ou corrente processadas pelo conversor, priorizando a injeção da potência gerada pela fonte local. Também é apresentado um breve estudo sobre a operação coordenada entre conversores multifuncionais em microrredes inteligentes de energia. Através de uma rede de dados os conversores são conectados a uma central de monitoramento e supervisão que ajusta de forma "on-line" as funções auxiliares que devem ser executadas por cada um dos conversores. As análises e testes realizados ao decorrer do trabalho consideram um cenário comumente encontrado em redes de distribuição de energia em baixa tensão, cujas impedâncias são elevadas e a distorção harmônica presente na tensão é considerável. As estratégias multifuncionais propostas neste trabalho foram validadas por resultados experimentais obtidos através da implementação de protótipos de conversores multifuncionais / Abstract: This thesis presents the development of strategies to operate grid-tied power electronic converters, which are conventionally used as power interface between renewable power sources and the grid, as a multifunctional device. Through the application of the proposed control techniques, the grid-tied converter is able to aggregate additional features intended to perform ancillary services related to power quality improvement. Therefore, the original function of the grid-tied converter is combined with features of an active power filter. The strategies developed to allow the multifunctional operation are based on the current throughout a local load which is connected at the point of coupling of the converter. By means of the decomposition of the load current into orthogonal components it is possible to choose the kind of disturbance to be compensated, as well as, the level of compensation. However, due to the unpredictable behavior of renewable energy sources and loads, the power or current capacity available in grid-tied converter may be insufficient to perform its primary function, i.e. the injection of the active power generated by the energy source, along with the power quality improvement. Therefore, strategies to limit the power or current processed by the converter are developed giving priority to the active power injection. It is also presented a brief study about the coordinated operation of multifunctional power converters used in smart microgrids. A communication network is used to connect the power converters to a remote central of supervision that adjusts the ancillary services each converter should perform. Analysis, tests and discussions performed in this thesis consider a scenario commonly observed in low voltage energy networks, where the grid is weak and, in general, non-sinusoidal. The strategies and techniques proposed were validated through experimental results obtained by the implementation of multifunctional power converters prototypes / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica