1

Distribution fault location using short-circuit fault current profile approach

Das, Swagata 09 July 2012 (has links)
Popularly used impedance-based methods need voltage and current waveform as well as line impedance per unit length to estimate distance to fault location. For a non-homogenous system with different line configuration, these methods assume that the system is homogenous and use the line impedance of the most frequently occurring line configuration. Load present in the system before fault is an important parameter which affects fault location accuracy. Impedance-based methods like Takagi and positive-sequence method assume that the load is lumped beyond the fault point which may not be true for a typical distribution system. As a result, accuracy of the impedance-based methods in estimating distance to fault is affected. Another short-coming of impedance-based methods are that they are unable to identify the branch in which the fault may be located. To minimize these errors, this thesis proposes a short-circuit fault current profile approach to complement impedance-based algorithms. In the short-circuit fault current profile approach, circuit model of the distribution feeder is used to place faults at every bus and the corresponding short-circuit fault current is plotted against reactance or distance to fault. When a fault occurs in the distribution feeder, fault current recorded by relay is extrapolated on the current profile to get location estimates. Since the circuit model is directly used in building the current profile, this approach takes into account load and non-uniform line impedance. Using the estimates from short-circuit fault current profile approach and impedance-based methods, the path on which the fault is located is identified. Next to improve fault location estimates, a median value of the estimates is computed. The median is a more robust estimate since it is not affected by outliers. The strategy developed above is tested using modified IEEE 34 Node Test Feeder and validated against field data provided by utilities. For the IEEE 34 Node Test Feeder, it is observed that the median estimate computed from impedance-based methods and the short-circuit fault current profile approach is very close to the actual fault location. Error in estimation is within 0.58 miles. It was also observed that if a 0.6 mile radius is built around the median estimate, the fault will lie within that range. Now the IEEE 34 Node Test Feeder represents a typical distribution feeder and has also been modeled to represent the worst case scenario, i.e. load current is around 51% of the fault current for the farthest bus. Hence the 0.6 mile radius around the median estimate will hold true for most distribution feeders and will be used when computing the fault range for field case events. For the field events, it was seen that the actual faults indeed lie within the 0.6 mile radius built around the median estimate and the path of the fault location has also been accurately estimated. For certain events, voltage waveform was not useful for analysis. In such situations, short-circuit fault current profile alone could be used to estimate fault location. Error in estimation is within 0.1 miles, provided the circuit model closely represents the distribution feeder. / text
2

Fault location and characterization in AC and DC power systems

Kulkarni, Saurabh Shirish 12 November 2013 (has links)
The focus of this research is on identification, location, interruption, characterization and overall management of faults in conventional AC distribution systems as well as isolated MVDC power systems. The primary focus in AC distributions systems is on identifying and locating underground cable faults using voltage and current waveforms as the input data. Cable failure process is gradual and is characterized by a series of single-phase sub-cycle incipient faults with high arc voltage. They often go undetected and eventually result in a permanent fault in the same phase. In order to locate such incipient cable faults, a robust yet practical algorithm is developed taking into account the fault arc voltage. The algorithm is implemented in the time-domain and utilizes power quality monitor data to estimate the distance to the fault in terms of the line impedance. It can be applied to locate both sub-cycle as well as permanent faults. The proposed algorithm is evaluated and proved out using field data collected from utility distribution circuits. Furthermore, this algorithm is extended to locate evolving faults on overhead distribution lines. Evolving faults are faults beginning in one phase of a distribution circuit and spreading to another phase after a few cycles. The algorithm is divided into two parts, namely, the single line-to-ground portion of the fault and the line-to-line-to-ground portion of the fault. For the single line-to-ground portion of the fault, the distance to the fault is estimated in terms of the loop or self-reactance between the monitor and the fault. On the other hand, for the line-to-line-to-ground and line-to-line portion of the fault the distance is estimated in terms of the positive-sequence reactance. The secondary focus of fault management in AC distribution systems is on identifying fault cause employing voltage and current waveform data as well as meteorological information. As the first step, unique characteristics of cable faults are examined along with methods to identify such faults with suitable accuracy. These characteristics are also used to distinguish underground cable faults from other overhead distribution line faults. The overhead line faults include tree contact, animal contact and lightning induced faults. Waveform signature analysis, wavelet transforms and arc voltages during the fault event are used for fault cause identification and classification. A statistical based classification methodology to identify fault cause is developed by utilizing promising characteristics. Unlike the AC system infrastructure which is already in place, the DC system considered in this document is that of a notional electric ship. The nature of DC current, with the absence of a current zero as well as the presence of power electronic devices influencing the current behavior, makes interrupting DC fault currents challenging. As a part of this research an innovative DC fault interruption scheme is proposed for rectifier- fed MVDC systems. A fault at the terminals of a phase-controlled rectifier results in a high magnitude current impulse caused by the filter capacitor discharging into the fault resistance. It is proposed to use a series inductor to limit the magnitude of this current impulse. The addition of the inductor results in an underdamped series RLC circuit at the output terminals of the rectifier which causes the fault current to oscillate about zero. Furthermore, it is proposed to utilize a conventional AC circuit breaker to interrupt this fault current by exploiting the zero crossings resulting from the oscillations. Using the proposed scheme for the example case, the peak fault current magnitude as well as the interruption time is significantly reduced. / text
3

Modeling, Control and Protection of Low-Voltage DC Microgrids

Salomonsson, Daniel January 2008 (has links)
Current trends in electric power consumption indicate an increasing use of dc in end-user equipment, such as computers and other electronic appliances used in households and offices. With a dc power system, ac/dc conversion within these loads can be avoided, and losses reduced. AC/DC conversion is instead centralized, and by using efficient, fully controllable power-electronic interfaces, high power quality for both ac and dc systems during steady state and ac grid disturbances can be obtained. Connection of back-up energy storage and small-size generation is also easier to realize in a dc power system. To facilitate practical application, it is important that the shift from ac to dc can be implemented with minimal changes. Results from measurements carried out on common household appliances show that most loads are able to operate with dc supply without any modifications. Furthermore, simple, and yet sufficiently accurate, load models have been derived using the measurement results. The models have been used for further analysis of the dc system, both in steady state and during transients. AC microgrids have gained research interest during the last years. A microgrid is a part of power systems which can operate both connected to the ac grid, and autonomously in island mode when the loads are supplied from locally distributed resources. A low-voltage dc microgrid can be used to supply sensitive electronic loads, since it combines the advantages of using a dc supply for electronic loads, and using local generation to supply sensitive loads. An example of a commercial power system which can benefit from using a dc microgrid is data center. The lower losses due to fewer power conversion steps results in less heat which need to be cooled, and therefore the operation costs are lowered. To ensure reliable operation of a low-voltage dc microgrid, well-designed control and protection systems are needed. An adaptive controller is required to coordinate the different resources based on the load-generation balance in the microgrid, and status of the ac grid. The performance of the developed controller has been studied and evaluated through simulations. The results show that it is possible to extend use of the data center dc microgrid to also support a limited amount of ac loads close to the data center, for example an office building. A protection-system design for low-voltage dc microgrids has been proposed, and different protection devices and grounding methods have been presented. Moreover, different fault types and their impact on the system have been analyzed. The type of protection that can be used depends on the sensitivity of the components in the microgrid. Detection methods for different components have been suggested in order to achieve a fast and accurate fault clearing. An experimental small-scale dc power system has been used to supply different loads, both during normal and fault conditions. A three-phase two-level voltage source converter in series with a Buck converter was used to interconnect the ac and the dc power systems. Together the converters have large controllability, high power quality performance, and allow bi-directional power flow. This topology can preferably be used together with energy storage. The tests confirm the feasibility of using a dc power system to supply sensitive electronic loads. / QC 20100908