Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel / Absorbed dose distribution in the treatment of Mycosis Fungoides using Fricke Xylenol Gel dosimetry

Silveira, Michely Cristina da 28 May 2010 (has links)
A radioterapia utiliza a radiação ionizante para a destruição de células tumorais. O controle da dose absorvida de um tipo específico de radiação aplicada a um volume alvo (tumor) é feito através da dosimetria, (uso de sensores de radiação), que neste trabalho foram utilizados os dosímetros químicos Fricke e filme. Dentre os diversos tipos de câncer, indicados para tratamento, utilizando a radiação ionizante, têm-se também a neoplasia Micose Fungóide (MF), linfoma que se alastra na superfície e em profundidade na pele para o qual elétrons com alta energia são utilizados para seu tratamento, devido aos seus alcances. Neste trabalho o Fricke Xilenol Gel (FXG) foi utilizado para o planejamento do tratamento da MF, para averiguar a distribuição da dose absorvida proveniente das interações dos elétrons com os tecidos. Para tal, foram construídas cubetas especiais em acrílico (tomos) conformacionadas aos contornos do crânio e do abdômen, que uma vez preenchidas com o FXG serviram para avaliar as doses absorvidas num objeto simulador antropomórfico, o Rando Phantom. O simulador, completado com cubetas e filmes radiocrômicos, este último também conformacionado aos dois contornos de interesse, foi submetido à técnica de Stanford para irradiação do corpo total com elétrons de 6 MeV. Imagens CCD e de densidade radiográfica foram feitas e posteriormente avaliadas, através de perfis horizontais e verticais passando por seus centros. Estes a seguir foram analisados por programas computacionais: um desenvolvido no Matlab para as imagens do FXG e o outro pelo programa já conhecido, ImageJ, para as imagens do filme. Das medidas, pode-se inferir que o dosímetro FXG se presta, similarmente ao filme, para as avaliações da dose absorvida devida aos elétrons na superfície do paciente e no seu interior, devida à contaminação por raios-X. / Radioterapy uses ionizing radiation to destroy tumor cells. The absorbed dose control in a target volume is done through dosimetry, using radiation sensors, being the Fricke and film used in this study. Among several types of cancer indicated for treatment using ionizing radiation, there is also the Mycosis Fungoides (MF), lymphom that spreads on surface and depth in the skin, for which high-energy electrons are used for its treatment. In this work the Fricke Xylenol Gel (FXG) was used for MF treatment control, to obtain the absorbed dose distribution from electrons interaction with the tissues. For this scope cuvettes were manufactured of acrylic (slices), with the same contours of the skull and abdomen anthropomorphic simulator tomos. Once filled with the FXG, these cuvettes were used to infer the absorbed dose by the anthropomorphic simulator Rando Phantom. This simulator, completed with the cuvettes and radiochromic films, this last one also with the same contours similar to skull and abdomen were submitted to the Stanford technique, for 6 MeV electrons total body irradiation. CCD and radiographic density images were acquired and evaluated by horizontal and vertical profiles through theirs centers. These profiles were analyzed through a computer programs: one developed in Matlab for FXG images and the other by an already known program, ImageJ, for film images. From the results one can infer that the FXG dosimeter presents similarity with that of film, in the evaluation of the absorbed dose distribution on surface and also inside of the patient.
12

Desenvolvimento de um leitor digital de absorbância microprocessado / SILVA, A. J. Development of a digital reader Absorbance microprocessor . Dissertation (Master) Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto - SP, 2011.

Silva, Aldriano José da 04 March 2011 (has links)
O espectrofotômetro, aparelho muito utilizado para realizar leituras de absorbância e/ou transmitância de amostras laboratoriais, pode ser aplicado para a realização de leituras do dosímetro químico Fricke Xilenol Gel. Este aparelho, por possuir componentes eletrônicos avançados e ser importado, apresenta um custo elevado e acaba muitas vezes se tornando um dispositivo inviável para medidas mais simples e rotineiras. O presente estudo implementou-se um aparelho portátil e de baixo custo, para que medidas específicas de absorbância possam ser feitas em laboratórios de ensino de física e que possa ser aplicado como leitor de dosímetros géis, como o acima citado. Este monoespectrofotômetro é constituído por uma fonte LED (próximo a 590 nm), um fotodiodo para avaliação da intensidade da luz transmitida e um display de LCD. Tal leitor permite a comunicação com microcomputadores via porta USB, facilitando o trabalho do usuário para manipular os resultados das medidas. A principal finalidade é voltada para uso acadêmico, no entanto, devido ao seu baixo custo e simplicidade, poderá também ser direcionado para atender outros segmentos como ambulatorial, industrial, cosmético, biológico, agronômico, dentre outros. / The spectrophotometer, a device often used to perform absorbance readings and or transmittance of laboratory samples, can be applied to perform readings in the chemical dosimeter Fricke Xylenol Gel. This device, once it has advanced electronics components and is imported, has an elevated cost and often ends up becoming an impractical device for most simple measurements and routine. This study implemented a device portable and inexpensive, so that specific measurements absorbance can be made in teaching laboratories of physics and that can be applied as a gel dosimeter reader, like the above. This monospectrophotometer consists of a LED source of visible light (near 590 nm), a photodiode to assess the intensity of transmitted light and an LCD display. This reader allows communication with computers via USB port, making it easier for users to manipulate the results of the measurements. The main purpose is directed for academic use, however, due to its low cost and simplicity, may also be applied to attend other segments such as outpatient, industrial, cosmetic, biological, agronomic, among others.
13

Aplicações de semicondutores orgânicos: de células solares nanoestruturadas a dosímetros de radiação ionizante / Applications of organic semiconductors: from nanostructured solar cells to ionizing radiation dosimeters.

Fernando Araújo de Castro 22 June 2007 (has links)
Semicondutores orgânicos têm atraído cada vez mais atenção da comunidade científica e de indústrias. O grande interesse se divide entre a riqueza de fenômenos físicos e químicos a serem estudados e o seu grande potencial de aplicação tecnológica nas mais diversas áreas: diodos emissores de luz (OLEDs), células solares e fotodiodos, transistores, biosensores, sensores de radiação ionizante, entre outros. O objetivo deste trabalho foi de contribuir para o avanço de duas áreas de aplicação, ambas relacionadas com a interação de radiação eletromagnética com a matéria: células solares e dosimetria de radiação gama. Na área de células solares, foram explorados dois dos principais limitadores do aumento de eficiência de conversão de potência: a falta de materiais com absorção na região em que o Sol emite mais fótons (infravermelho próximo (NIR)) e a dificuldade de controle da morfologia interna das células. Foi demonstrado um novo conceito de fabricação de células solares através da nanoestruturação de filmes finos poliméricos. A metodologia de estruturação se baseia no processo de separação de fases em blendas poliméricas durante o processo de deposição por spin-coating e a subseqüente remoção de uma das componentes. Assim é possível obter uma camada ativa cobrindo todo o substrato e apresentando ondulações na superfície que podem ser variadas desde alguns nanômetros de altura e largura até micrômetros. O processo de nanoestruturação é discutido e dispositivos fotovoltaicos foram produzidos cobrindo filmes nanoestruturados de MEH-PPV com fulereno C60. A eficiência de conversão de potência destas células é três vezes maior do que o melhor resultado já reportado para este par de materiais até o momento e atinge quase 3% sob irradiação monocromática. Utilizando corantes cianinos, dispositivos fotovoltaicos e fotodiodos com resposta desde no visível até o infravermelhor próximo (~1000 nm) foram demonstrados e foi observado um papel importante dos íons móveis presentes nos corantes. Finalmente, foi demonstrada a aplicabilidade de um corante polimerizado como dosímetro de radiação gama. A faixa de operação do dosímetro pode ser alterada variando-se a concentração da solução do corante, que poderia ser utilizado na região de doses de irradiação de alimentos. / Organic semiconductors have atracted much attention from the scientific community and from the industry. The large interest is divided between the rich number of basic physical and chemical phenomena to be investigated and the great technological potential for application in different areas, such as light emitting diodes (OLEDs), solar cells, photodiodes, transistors, biosensors, ionizing radiation sensors, among others. The subject of this work was to contribute to a deeper understanding of two areas of application, both related to the interaction of electromagnetic radiation with matter: solar cells and gamma ray dosimetry. In the area of solar cells, the lack of materials absorbing in the near infrared (NIR) and the poor control of the morphology of the active films are limiting factor to increasing device efficiency. Therefore both this aspects were explored. A new concept of organic solar cell fabrication was presented based on the anostructuration of polymeric thin films. The methodology is based on phase separation of polymer blends during spin-coating followed by the selective removal of one component. This allows the controlled formation of thin films with characteristic features varying from a few nanometers to micrometers. The effects of molecular weigth, solvent and relative composition were investigated and discussed based on the analysis of AFM images and phase separation models. Devices using structured MEH-PPV layers, covered by C60 were fabricated and showed white light power conversion efficiencies (?) up to 400 % higher than a flat double layer device. Monochromatic ? achieved 2.95 % (480 nm), three times higher than the best reported value for this material combination so far. Using cyanine dyes, photovoltaic devices and photodiodes active in the NIR (~1000 nm) were demosntrated and an important effect of movable ions present in the dyes was observed. Finally, the application of a polymerized dye as gamma ray dosimeter was demonstrated. The operation range can be altered by varying the concentration of polymer in solution, and are useful in the range of low dose food irradiation.
14

Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel / Absorbed dose distribution in the treatment of Mycosis Fungoides using Fricke Xylenol Gel dosimetry

Michely Cristina da Silveira 28 May 2010 (has links)
A radioterapia utiliza a radiação ionizante para a destruição de células tumorais. O controle da dose absorvida de um tipo específico de radiação aplicada a um volume alvo (tumor) é feito através da dosimetria, (uso de sensores de radiação), que neste trabalho foram utilizados os dosímetros químicos Fricke e filme. Dentre os diversos tipos de câncer, indicados para tratamento, utilizando a radiação ionizante, têm-se também a neoplasia Micose Fungóide (MF), linfoma que se alastra na superfície e em profundidade na pele para o qual elétrons com alta energia são utilizados para seu tratamento, devido aos seus alcances. Neste trabalho o Fricke Xilenol Gel (FXG) foi utilizado para o planejamento do tratamento da MF, para averiguar a distribuição da dose absorvida proveniente das interações dos elétrons com os tecidos. Para tal, foram construídas cubetas especiais em acrílico (tomos) conformacionadas aos contornos do crânio e do abdômen, que uma vez preenchidas com o FXG serviram para avaliar as doses absorvidas num objeto simulador antropomórfico, o Rando Phantom. O simulador, completado com cubetas e filmes radiocrômicos, este último também conformacionado aos dois contornos de interesse, foi submetido à técnica de Stanford para irradiação do corpo total com elétrons de 6 MeV. Imagens CCD e de densidade radiográfica foram feitas e posteriormente avaliadas, através de perfis horizontais e verticais passando por seus centros. Estes a seguir foram analisados por programas computacionais: um desenvolvido no Matlab para as imagens do FXG e o outro pelo programa já conhecido, ImageJ, para as imagens do filme. Das medidas, pode-se inferir que o dosímetro FXG se presta, similarmente ao filme, para as avaliações da dose absorvida devida aos elétrons na superfície do paciente e no seu interior, devida à contaminação por raios-X. / Radioterapy uses ionizing radiation to destroy tumor cells. The absorbed dose control in a target volume is done through dosimetry, using radiation sensors, being the Fricke and film used in this study. Among several types of cancer indicated for treatment using ionizing radiation, there is also the Mycosis Fungoides (MF), lymphom that spreads on surface and depth in the skin, for which high-energy electrons are used for its treatment. In this work the Fricke Xylenol Gel (FXG) was used for MF treatment control, to obtain the absorbed dose distribution from electrons interaction with the tissues. For this scope cuvettes were manufactured of acrylic (slices), with the same contours of the skull and abdomen anthropomorphic simulator tomos. Once filled with the FXG, these cuvettes were used to infer the absorbed dose by the anthropomorphic simulator Rando Phantom. This simulator, completed with the cuvettes and radiochromic films, this last one also with the same contours similar to skull and abdomen were submitted to the Stanford technique, for 6 MeV electrons total body irradiation. CCD and radiographic density images were acquired and evaluated by horizontal and vertical profiles through theirs centers. These profiles were analyzed through a computer programs: one developed in Matlab for FXG images and the other by an already known program, ImageJ, for film images. From the results one can infer that the FXG dosimeter presents similarity with that of film, in the evaluation of the absorbed dose distribution on surface and also inside of the patient.
15

Desenvolvimento de um leitor digital de absorbância microprocessado / SILVA, A. J. Development of a digital reader Absorbance microprocessor . Dissertation (Master) Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto - SP, 2011.

Aldriano José da Silva 04 March 2011 (has links)
O espectrofotômetro, aparelho muito utilizado para realizar leituras de absorbância e/ou transmitância de amostras laboratoriais, pode ser aplicado para a realização de leituras do dosímetro químico Fricke Xilenol Gel. Este aparelho, por possuir componentes eletrônicos avançados e ser importado, apresenta um custo elevado e acaba muitas vezes se tornando um dispositivo inviável para medidas mais simples e rotineiras. O presente estudo implementou-se um aparelho portátil e de baixo custo, para que medidas específicas de absorbância possam ser feitas em laboratórios de ensino de física e que possa ser aplicado como leitor de dosímetros géis, como o acima citado. Este monoespectrofotômetro é constituído por uma fonte LED (próximo a 590 nm), um fotodiodo para avaliação da intensidade da luz transmitida e um display de LCD. Tal leitor permite a comunicação com microcomputadores via porta USB, facilitando o trabalho do usuário para manipular os resultados das medidas. A principal finalidade é voltada para uso acadêmico, no entanto, devido ao seu baixo custo e simplicidade, poderá também ser direcionado para atender outros segmentos como ambulatorial, industrial, cosmético, biológico, agronômico, dentre outros. / The spectrophotometer, a device often used to perform absorbance readings and or transmittance of laboratory samples, can be applied to perform readings in the chemical dosimeter Fricke Xylenol Gel. This device, once it has advanced electronics components and is imported, has an elevated cost and often ends up becoming an impractical device for most simple measurements and routine. This study implemented a device portable and inexpensive, so that specific measurements absorbance can be made in teaching laboratories of physics and that can be applied as a gel dosimeter reader, like the above. This monospectrophotometer consists of a LED source of visible light (near 590 nm), a photodiode to assess the intensity of transmitted light and an LCD display. This reader allows communication with computers via USB port, making it easier for users to manipulate the results of the measurements. The main purpose is directed for academic use, however, due to its low cost and simplicity, may also be applied to attend other segments such as outpatient, industrial, cosmetic, biological, agronomic, among others.
16

Dosímetro FXGB para caracterização de feixes em radioterapia / FXGB Dosimeter for Beam Characterization in Radiotherapy.

Paulo Cesar Dias Petchevist 26 June 2006 (has links)
Desde a descoberta dos raios X por Wilhelm Conrad Roentgen em 1895, a medicina vem fazendo uso da radiação ionizante para o tratamento de alguns cânceres. No entanto, para que os tratamentos se façam com maior precisão, há a necessidade de um controle de qualidade adequado, que é da responsabilidade do físico médico de um serviço de radioterapia. Do aprimoramento do dosímetro químico Fricke em 2000 [BERO et al, 2000], através da adição de alaranjado de xilenol e gelatina de origem animal 300 Bloom, alcançou-se um aumento da sensibilidade e estabilidade da substância química. Porém, o custo da importação da gelatina e de um espectrofotômetro para as medidas de absorção óptica na determinação da dose absorvida poderia dificultar a utilização desse dosímetro num serviço de radioterapia. O presente trabalho busca apresentar uma alternativa simples e barata para atender às situações apresentadas através da substituição da gelatina importada por uma nacional (atualmente em teste) constituindo o novo dosímetro FXGB, que permitiu uma caracterização prévia de feixes de fótons (1,25 MeV) e elétrons (5, 7 e 10 MeV), além da determinação de parâmetros físicos para elétrons como fator e perfil de campo e porcentagem de dose profunda. As medidas foram realizadas com um protótipo leitor portátil (RADIARE III) desenvolvido [FELIPE, 2001] e otimizado [ZAIAS, 2006] em nosso grupo de pesquisa. Dessas medidas foi comprovado que o novo dosímetro é adequado para ser utilizado em medidas de dose absorvida na radioterapia para fótons e elétrons. / Since the X rays discovery for Wilhelm Conrad Roentgen in 1895, the medicine started to use the ionizing radiation for some cancers treatments. However, to obtain higher precision in the treatments is necessary an adequate quality control, which is a medical physicist responsibility in the service. This work was developed to assist the medical physicist on the quality control through an simple, inexpensive and commercially accessible dosimetry. From the chemical dosimetry Fricke improvement in 2000 [BERO et al, 2000], through the orange xilenol and 300 Bloom gelatin addition, it was shown a sensibility and chemicalstability improvement. However, the high cost and difficulty to import the gelatin and necessity to utilize an spectrophotometer to determine the absorbed dose lead us to find another new gelatin adequate for the measurements. The new FXGB dosimeter was characterized for photons (1,25 MeV) and electrons (5, 7 and 10 MeV) and applied for some electrons beam physical determination as: field factor, field profile and depth dose percentage (PDD). From the obtained results, the FXGB dosimetric system (FXGB gel + prototype RADIARE III) show a promising option to assist the quality control in an radiotherapy service.
17

Gel Turnbull Blue aplicado à dosimetria de radiação ultravioleta e visível / Turnbull Blue Gel applied to ultraviolet and visible radiation dosimetry

Euclydes Borguezan Neto 21 October 2016 (has links)
O gel radiocrômico Turnbull Blue (TBG) é sensível a raios gamma e x. Este composto tem sido utilizado em dosimetria de radiações ionizantes devido à sua capacidade de simular tecido biológico quando exposto à radiação de alta energia. Após sua irradiação, o TBG sofre uma mudança de cor: o aspecto amarelo torna-se azul devido à formação do corante Turnbull Blue. Essa alteração de cor produz uma larga banda de absorção na faixa espectral do visível, com pico localizado em 690 nm. A intensidade desta banda é proporcional à dose de radiação absorvida. Entretanto, o comportamento do TBG, quando exposto a radiações menos energéticas, como luz visível e ultravioleta, ainda não é conhecido. Considerando as recomendações de organizações internacionais sobre os riscos do uso de tais radiações, esta pesquisa teve como objetivo caracterizar a resposta do TBG, quando irradiado por diferentes fontes ultravioletas e visíveis, tais como lâmpadas fluorescentes, LEDs e um simulador solar. O tempo entre a exposição do gel e a leitura de sua resposta foi estudado, assim como a influência da utilização de fontes com diferentes irradiâncias e diferentes temperaturas de irradiação. Um espectrômetro, operando na faixa espectral de 350 nm a 900 nm, foi utilizado para mensurar a mudança de cor no gel. Os resultados mostraram que o gel possui diferentes sensibilidades de acordo com a faixa espectral entregue pela fonte: a radiação UVC produziu a alteração de cor mais intensa, seguida pela UVB, UVA e visível, respectivamente. A temperatura de irradiação e a irradiância da fonte tiveram influência considerável na mudança de cor do TBG. Os resultados mostraram que é possível usar o gel TBG como um dosímetro de radiação óptica, desde que fatores de correção relacionados à irradiância da fonte e temperatura de irradiação sejam levados em consideração. / The radiochromic gel Turnbull Blue (TBG) is sensitive to gamma and x-rays. This compound has been utilized in ionizing radiation dosimetry, since it acts as biological tissue simulator when exposed to high-energy radiation. Subsequently to its radiation, TBG shows a color shift: the original yellow aspect becomes blue due to the production of the colorant Turnbull Blue. Such chromic shift yields a broad absorption band in the visible spectral range, with a peak located at 690 nm. The intensity of this band is proportional to the absorbed radiation dose. However, the behavior of TBG when exposed to less energetic radiation, e.g. ultraviolet and visible light, remains unclear. Considering the recommendations of international organizations regarding the risks of using such type of radiation, this research aimed to characterize the TBG response when irradiated by different ultraviolet and visible sources as well as to determine its sensitivity to the radiation in the UV-Visible spectral range. Furthermore, this investigation evaluated the viability of TBG as an optical dosimeter. During this study, the gel was exposed to different non-ionizing radiation sources, such as fluorescent lamps, LEDs and a sun simulator. The time between the gel exposition and the measurement of its response was studied, as well as the influence of different source irradiances and temperatures of irradiation. A spectrometer operating on the 350-900 nm spectral range has measured the gel color shift. The results showed different sensitivities according to the spectral range delivered by the source: UVC has produced the most intense change in color, followed by UVB, UVA and visible, respectively. The temperature of irradiation and the irradiance provided by the sources have shown considerable influence on the color shift. The results showed that it is possible to use the TBG gel as optical radiation dosimeter. The use of correction factors for temperature of irradiation and irradiance of the source are mandatory.
18

Determinação pelo metodo da dosimetria termoluminescente, das doses de radiação incidentes em orgãos criticos, durante a obtenção de radiografias cefalometricas : estudo comparativo entre duas condições de regulagem do aparelho de raios X

Di Hipolito Junior, Oswaldo, 1944- 14 July 2018 (has links)
Orientador : Lourenço Bozzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-14T10:26:31Z (GMT). No. of bitstreams: 1 DiHipolitoJunior_Oswaldo_M.pdf: 1309125 bytes, checksum: 02a0d4a435d43722c19013e7154b3919 (MD5) Previous issue date: 1980 / Resumo: Não informado / Abstract: Not informed. / Mestrado / Patologia / Mestre em Odontologia
19

Avaliação nacional da exposição ocupacional à radiação por urologistas brasileiros / National survey on occupational radiation exposure by brazilian urologists

Borges, Cláudio Ferreira, 1980- 02 March 2015 (has links)
Orientador: Adriano Fregonesi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T20:23:11Z (GMT). No. of bitstreams: 1 Borges_ClaudioFerreira_D.pdf: 1990683 bytes, checksum: 1a75e1725e18e65f74c600f93224b4bb (MD5) Previous issue date: 2015 / Resumo: Objetivo: Foi realizada uma pesquisa de âmbito nacional com urologistas brasileiros a fim de estudar seu comportamento frente à exposição à radiação e ao uso de equipamentos de proteção e monitoramento. Material e Métodos: Um questionário com 13 perguntas foi enviado por e-mail para urologistas brasileiros; as questões abordavam temas como características demográficas, a exposição à radiação, bem como a utilização de dispositivos de proteção e dosímetros. As razões pelas quais esses dispositivos não foram utilizados também foram investigadas. Resultados: Um total de 332 questionários foi preenchido completamente e analisado; a idade média dos entrevistados foi de 43,3 ± 10,8 anos. Aventais de chumbo e protetores de tireoide são utilizados em cada procedimento por 84,4% e 53,89% dos entrevistados, respectivamente. Óculos de proteção nunca são utilizados por 72,12% dos entrevistados. Urologistas mais velhos são mais propensos a não usar proteção adequada. Dos urologistas que responderam, 76,42% nunca usam dosímetros. Conclusão: Este estudo mostra uma utilização insatisfatória dos dispositivos de proteção contra radiação e dosímetros, revelando uma baixa adesão ao ALARA (as low as reasonably achievable) entre urologistas brasileiros / Abstract: Purpose: We performed a nationwide survey of Brazilian urologists to study behaviors toward radiation exposure and the use of protective and monitoring equipment. Material and Methods: A 13-question e-mail questionnaire was sent to Brazilian urologists; the questions addressed demographic characteristics, radiation exposure, and the utilization of shielding devices and dosimeters. The reasons why these devices were not used were also investigated. Results: A total of 332 completed questionnaires were analyzed; the median age of the respondents was 43.3 ± 10.8 years. Lead aprons and thyroid protection are utilized in every procedure by 84.4% and 53.89% of respondents, respectively. Protective eyeglasses are never used by 72.12% of the respondents. Older urologists were more likely not to use adequate protection. Of the urologists who responded, 76.42% never use dosimeters. Conclusion: This study shows an unsatisfactory utilization of radiation-shielding devices and dosimeters, revealing a low compliance to the ALARA (as low as reasonably achievable) principle among Brazilian urologists / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências
20

Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG / Physical Dosimetric Parameters Commissioning in Clinical Linear Accelerators using FXG dosimeter

Petchevist, Paulo Cesar Dias 22 May 2015 (has links)
A International Comission on Radiation Units and Measurements (ICRU) recomenda que a incerteza total de um tratamento radioterápico não deva ultrapassar de 5%, ou seja, cada etapa do processo de entrega da dose absorvida ao volume alvo do paciente tenha incerteza menor que esse valor (ICRU 50, 1993; ICRU 62, 1999). O cuidado com essas incertezas inicia-se na instalação da máquina (neste caso, de um Acelerador Linear Clínico), passando pela sua aceitação, pelo comissionamento, perdurando nos controles de qualidade posteriores e até em novos comissionamentos, se necessários. Os parâmetros físicos dosimétricos mínimos necessários a serem comissionados para feixes de fótons e elétrons são: Porcentagem de Dose em Profundidade (PDD), Perfis de Campos abertos e filtrados, Fatores de Espalhamento Total (Scp), Cone (Fcone) e de Transmissão (de Filtros em cunha FF, Bandeja FB, e de Transmissão intra FMLC,intra e de fuga inter lâminas FMLC,inter), além da Determinação da Posição Virtual da Fonte de Elétrons através da SSD efetiva (SSDeff). Para tal, a American Association of Physicists in Medicine (AAPM), através do seu protocolo mais recente, apresenta objetos simuladores, tipos e tamanhos de detectores, arranjos e procedimentos experimentais específicos, através dos quais é possível inferir os parâmetros dosimétricos de feixes de fótons e elétrons, usando varredura destes com câmara de ionização (CI), considerando o erro total das medidas menor do que 1% (AAPM TG 106, 2008). Entretanto este mesmo protocolo cita de maneira sucinta ou pouco detalhada, a possibilidade da utilização de dosímetros tipo gel para o citado comissionamento, já que possuem diversas vantagens a serem consideradas na Radioterapia, como equivalência ao tecido mole (Z e ), independência energética num amplo intervalo de energia de fótons e elétrons, além da alta resolução espacial. Desta forma, o objetivo geral deste trabalho é apresentar de forma inédita, o comissionamento dos parâmetros físicos dosimétricos de aceleradores lineares clínicos (PFDALC), especificamente através do dosímetro Fricke Xilenol Gel (FXG), como método alternativo e/ou complementar aos internacionais vigentes. Para tal, neste trabalho foram desenvolvidos dispositivos e procedimentos que proporcionassem aos usuários uma forma prática, eficiente e de baixo custo para obtenção dos parâmetros citados através do FXG, em relação aqueles obtidos com a CI (método padrão). Todos os resultados dos parâmetros físicos dosimétricos obtidos com o dosímetro citado foram validados com a CI, considerando a incerteza preconizada para a mesma. Esses resultados sugerem que o FXG efetivamente poderá ser utilizado para o comissionamento de aceleradores lineares clínicos e que um protocolo específico para este dosímetro poderá ser gerado. / The International Commission on Radiation Units and Measurements (ICRU) recommends that the total radiotherapy treatment uncertainty should not exceeds 5%, in other words, considering that each step involved in the absorbed dose delivery process should not surpass the cited value (ICRU 50, 1993; ICRU 62, 1999). The uncertainties considered are those involved with, the machine installation (in this work, a Clinical Linear Accelerator), its acceptance, commissioning, followed by those related to subsequent quality controls and even new commissioning, if necessary. The minimum required physical dosimetric parameters to be commissioned for electron or photon beams are: the Percentage Depth Dose (PDD), the filtered and open Field Profiles, Total Scatter Factors (Scp), Cone Factor (Fcone), Transmission Factors: Wedge Filter (FF), Tray (FB), intra Leaf (FMLC,intra) and inter Leaf Leakage (FMLC,inter), besides the Virtual Source Position Determination (SSDeff). For this purpose, the American Association of Physicists in Medicine (AAPM), through its last protocol, provides guidelines on phantom and detector selections, setting up of phantom for data acquisition (for scanning and no-scanning data), procedures for acquiring the cited beam parameters with ionizing chambers (CI) and methods to reduce the total measurement error lower than 1% (AAPM TG 106, 2008). However, this protocol does not present any information or details about the physical dosimetric parameters for clinical linear accelerators (PFDALC), through gel dosimeters once they present several useful advantages for Radiotherapy, such as: soft tissue equivalence (Z and ), wide energy independence range for photons or electrons beams and high spatial resolution. The scope of this work is to present an innovative way for physical dosimetric parameters commissioning, specifically using the Fricke Xylenol Gel (FXG) dosimeter, like an alternative and/or complementary method to that employed internationally. Devices and procedures have been developed for this work in order to infer the cited parameters, in a practical, efficient and low cost way, compared to that used with CI (standard method). All the FXG results obtained were validated with the CI, considering the uncertainty recommended for the last one. The results suggest that the FXG effectively can be used for physical dosimetric parameters commissioning for clinical linear accelerators and a new specific protocol can be generated.