• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 392
  • 294
  • 54
  • 42
  • 14
  • 10
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 1239
  • 674
  • 381
  • 234
  • 155
  • 154
  • 152
  • 152
  • 116
  • 103
  • 102
  • 100
  • 92
  • 92
  • 90
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação do dispositivo eletrônico de imagem portal \"Portal Dosimetry\" no controle de qualidade de radioterapia de intensidade modulada / Evaluation of electronic imaging device portal \"Portal Dosimetry\" in quality control in intensity modulated radiotherapy

Érika Yumi Watanabe 13 August 2010 (has links)
No presente trabalho serão apresentados testes de comissionamento e de avaliação da utilização do portal dosimetry, da Varian, no controle de qualidade dos planejamentos de radioterapia de intensidade modulada. Os testes de comissionamento foram realizados para caracterizar o portal dosimetry em termos dosimétricos e para avaliar a sua possível aplicação em radioterapia. Esses testes demonstraram que o portal dosimetry possui todas as características necessárias para ser utilizado em dosimetria na radioterapia tais como linearidade da resposta com a dose, independência com a taxa de dose, reprodutibilidade, dentre outras. A avaliação da utilização do portal dosimetry no controle de qualidade de IMRT foi realizada em duas etapas: avaliação da capacidade do dispositivo em detectar erros propositalmente introduzidos em fluências simples e em fluências complexas. Foram introduzidos erros de magnitude conhecida em áreas determinadas das fluências e foi realizado o controle de qualidade dessas fluências com o portal dosimetry e com mais três sistemas dosimétricos: câmara de ionização, filme e matriz de câmaras de ionização. Os dados obtidos com o portal foram comparados com os dos outros dispositivos e todos foram capazes de identificar os erros introduzidos de maneira satisfatória, sendo os valores, normalizados para a fluência original, obtidos com o dosímetro portal indênticos aos da câmara de ionização e aos da matriz de câmaras de ionização (seven29) e diferindo em até 2% dos valores obtidos com os filmes. As fluências medidas com o portal dosimetry foram avaliadas em termos quantitativos e qualitativos. Os índices da função gama fornecidos pelo software de análise do portal dosimetry não apresentaram regras definidas de comportamento em relação aos erros introduzidos e por essa razão a análise qualitativa se mostrou indispensável nos casos avaliados. / In this paper we present commissioning testing and evaluation of the use of Varians portal dosimetry in the quality assurance of intensity-modulated radiotherapy. The commissioning tests were performed to characterize the portal dosimetry in terms dosimetric and to assess the its possible application in radiotherapy. These tests demonstrated that portal dosimetry has all the characteristics to be used for dosimetry in radiotherapy such as linear response with dose, the independence of dose rate, reproducibility, and others. The evaluation of the use of portal dosimetry in quality control of IMRT was performed in two steps: assessing the ability of the device to detect errors deliberately introduced in simple and complex fluences. Errors of known magnitude were introduced in certain areas of fluences and was carried out quality control of these fluences with portal dosimetry and three dosimetric systems: ionization chamber, film and array of ionization chambers. The data obtained from the portal were compared with those of other devices and all were able to identify errors introduced satisfactorily, the values, normalized to the original fluence, obtained with the portal dosimetry were similar to the ionization chamber and the array of ion chambers (seven29) and differing in up to 2% of the values obtained with the films. The fluences measured with the portal dosimetry were evaluated both quantitatively and qualitatively. The index of the gamma function provided by software analysis of portal dosimetry showed no defined rules of behavior in relation to the errors introduced and for this reason the qualitative analysis has proved indispensable in cases evaluated.
72

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fótons

BARSANELLI, CRISTIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:43Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
73

Implementacao da irradiacao de corpo inteiro em radioterapia / Implementation of total body irradiation in radiotherapy

HABITZREUTER, ANGELA B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:05Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
74

Zpracování výukového programu pro předměty: "DOZIMETRIE IONIZUJÍCÍHO ZÁŘENÍ" "KLINICKÁ DOZIMETRIE" / Processing of education schedule the areas: "Dosimetry of ionising radiation", "Clinical dosimetry"

LEŠTINA, Štěpán January 2007 (has links)
The problem I am dealing with in the diploma thesis : Processing of education schedule the areas: {\clqq}Dosimetry of ionising radiation``, {\clqq}Clinical dosimetry``, is connected with a creating of practical internet applications of formal training of university´s students. To design certain applications which would tend to be more effective in teaching and would lead to easier understading of given curriculum is the main aim of this work. It also concerns a didactic approach to teaching the subjects, such as: {\clqq}Dosimetry of ionising radiation``, {\clqq}Clinical dosimetry``, which is included in curriculum of Bachelor and Master degree studies in the Department of Radiology and Toxicology at University of South Bohemia České Budějovice. The important component of the thesis is a teaching program which is accesible also on the web side : http://www.lestinas.webzdarma.cz
75

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fótons

BARSANELLI, CRISTIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:43Z (GMT). No. of bitstreams: 0 / Neste trabalho, estão descritos os métodos de seleção, calibração e de determinação dos fatores de correção, as características físicas dos dosímetros termoluminescentes, o procedimento de cálculo para converter a leitura do dosímetro em dose absorvida e a metodologia para se determinar a dose de entrada. Foram investigadas a praticidade e a utilidade das medidas de dose de entrada com os dosímetros termoluminescentes, bem como a exatidão e a reprodutibilidade no fornecimento da dose diária. As medidas de dose de entrada foram realizadas em cinco pacientes com diagnóstico de câncer de mama tratadas com um feixe de fótons de 6 MV. Não foram detectados grandes desvios entre a dose medida e a dose esperada (os valores concordaram em ± 5%), devido à excelente estabilidade do equipamento de tratamento, ao sistema automático de verificação e à boa exatidão no ajuste diário do tratamento. Uma boa precisão pode ser alcançada quando os fatores de correção para cada parâmetro de influência na resposta do dosímetro são cuidadosamente determinados e aplicados para converter o sinal termoluminescente em dose absorvida. O estudo demonstrou a viabilidade do uso dos dosímetros termoluminescentes para a dosimetria in vivo e sua utilidade como parte de um programa de garantia de qualidade em um serviço de radioterapia. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
76

Implementacao da irradiacao de corpo inteiro em radioterapia / Implementation of total body irradiation in radiotherapy

HABITZREUTER, ANGELA B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:05Z (GMT). No. of bitstreams: 0 / Ao implementar uma técnica de tratamento, as características do feixe nas condições de irradiação precisam ser bem conhecidas e estudadas. Cada um dos parâmetros utilizados para cálculo de dose deve ser medido e validado antes da utilização dos mesmos na rotina clínica. Isso se torna ainda mais necessário quando se tratam de técnicas especiais. Neste trabalho estão descritos todos os parâmetros e medidas necessárias para a implementação da irradiação de corpo inteiro numa instalação projetada para tratamentos convencionais, e que faz uso de geometrias não convencionais para gerar os tamanhos de campos alargados. Além disso, são apresentados os dados de comissionamento desta modalidade no Hospital das Clínicas de São Paulo utilizando a comparação de três tipos de detectores para medidas de dose de entrada durante tratamentos de irradiação de corpo inteiro. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
77

Modelling induced fields in the human body exposed to electric fields from high voltage transmission lines designed to meet 10 kV/m at ground level

Hubbard, Kenneth Roy January 2017 (has links)
A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, Johannesburg, in fulfilment of the requirements for the degree of Master of Science in Engineering. Johannesburg, February 2017 / There has been increasing public concern regarding adverse health effects due to power frequency electric and magnetic fields. Safety guidelines/standards for electric and magnetic field exposures have been established by different public organizations. However, the link between low frequency (power frequency) electric and magnetic field exposure and adverse health effects is not yet well established. Limits on human exposure to low frequency electric and magnetic fields are fundamentally specified for in-situ fields in tissues/organs. These dosimetric limits are referred to as Basic Restrictions for protection against potentially adverse effects from electro-stimulation. In addition, secondary limits, the exposure Reference Levels in environmental electric and magnetic fields are also given for practical compliance purposes. These are generally derived from the Basic Restrictions based on uniform-fields with a provision that the Basic Restrictions must be observed for non-uniform cases. In practice, any structure influences the electric fields in High Voltage systems, and thus creates electric field non-uniformity. The human exposure of the general public to electric fields from Eskom’s 765 kV transmission network operating at 50 Hz, is addressed through physical measurements, theoretical predictions and 3-D human model dosimetry, which is presented in this dissertation. / MT 2017
78

Estudo e levantamentos de parâmetros para  dosimetria de fontes de Iodo -125 aplicadas em braquiterapia / Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy

Moura, Eduardo Santana de 10 February 2011 (has links)
A utilização da técnica braquiterapia com sementes de iodo-125 para o tratamento do câncer de próstata têm sido utilizada por décadas com bons resultados clínicos. Para atender as necessidades da população brasileira, o IPEN-CNEN/SP desenvolveu o protótipo para as sementes de iodo-125 com tecnologia nacional. Os objetivos deste trabalho são o desenvolvimento e estudo dos processos dosimétricos associados à obtenção experimental dos parâmetros úteis à caracterização das sementes de iodo-125 e avaliar se os procedimentos desenvolvidos, por este trabalho, possuem as condições necessárias para a determinação das análises dosimétricas, fundamentais para o sucesso dos procedimentos clínicos. Os dosímetros escolhidos para as análises são os TLD-100 (LiF:Mg,Ti), inicialmente estes dosímetros foram submetidos por duas etapas de seleção, com o objetivo de escolher os dosímetros mais reprodutíveis para as análises dosimétricas. As duas etapas foram à seleção por medidas de massa e a reprodutibilidade após quatro séries de irradiações por um irradiador de Cobalto-60 (CTR-IPEN). Após estas etapas, os dosímetros foram irradiados em um acelerador linear com energia de 6 MV (Serviço de Radioterapia Hospital Israelita Albert Einstein) para gerar os fatores de calibração individuais para cada dosímetro. Posteriormente, os dosímetros foram utilizados para as irradiações com a semente de iodo-125, modelo 6711 (GE-Healthcare). As irradiações com a semente de iodo-125 e demais análises renderam os valores necessários para a determinação dos parâmetros sugeridos pela AAPM (American Association of Physicists in Medicine): constante de taxa de dose, função de geometria, função de dose radial e função de anisotropia. Os resultados obtidos mostram boa concordância com os valores publicados pela literatura, para o mesmo modelo de semente de iodo-125, ratificando que os parâmetros realizados poderão ser utilizados para a dosimetria e controle de qualidade das sementes de iodo- 125 que irão ser produzidas pelo IPEN-CNEN/SP. / The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control.
79

Dosimetric and Radiobiological Plan Evaluation Parameters for Fractionated High-Dose Rate GYN Brachytherapy

Unknown Date (has links)
Intracavitary high-dose-rate brachytherapy (HDRBT) is a treatment option for endometrial cancer, depending on the cancer stage. Because of the steep high dose gradient of HDRBT, very small differences in the treatment plans, surrounding organ’s anatomy, or procedures during the treatment could potentially cause significant dose variation to the tumor, as well as organs at risks (OAR) nearby the treatment area, which could result in unwanted radiobiological side effects. In this retrospective study, the radiobiological plan evaluation parameters Equivalent Uniform Dose (EUD), Normal Tissue Complication Probability (NTCP) are used as assessment tools to evaluate HDRBT plans. Furthermore, gynecological applicator position in the coordinate system, and possible dose variations to the tumor and critical organs from the initial fraction in comparison with subsequent fractions over the entire multi fractionated treatment are studied. The evaluations were performed for 118 HDR treatment plans for 30 patients by registration of the subsequent treatment plans into the initial CT-image guided plan. Dose fractionation regimens varied from 4Gy to 7Gy per fraction, 1 or 2 fractions per week, depending on the cancer stage. Our results demonstrate no significant radiobiological impacts on organs at risks (OAR). In addition, the results of the applicator positions’ study indicate that improvement of immobilization and localization devices are recommended. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2018. / FAU Electronic Theses and Dissertations Collection
80

Estudo e levantamentos de parâmetros para  dosimetria de fontes de Iodo -125 aplicadas em braquiterapia / Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy

Eduardo Santana de Moura 10 February 2011 (has links)
A utilização da técnica braquiterapia com sementes de iodo-125 para o tratamento do câncer de próstata têm sido utilizada por décadas com bons resultados clínicos. Para atender as necessidades da população brasileira, o IPEN-CNEN/SP desenvolveu o protótipo para as sementes de iodo-125 com tecnologia nacional. Os objetivos deste trabalho são o desenvolvimento e estudo dos processos dosimétricos associados à obtenção experimental dos parâmetros úteis à caracterização das sementes de iodo-125 e avaliar se os procedimentos desenvolvidos, por este trabalho, possuem as condições necessárias para a determinação das análises dosimétricas, fundamentais para o sucesso dos procedimentos clínicos. Os dosímetros escolhidos para as análises são os TLD-100 (LiF:Mg,Ti), inicialmente estes dosímetros foram submetidos por duas etapas de seleção, com o objetivo de escolher os dosímetros mais reprodutíveis para as análises dosimétricas. As duas etapas foram à seleção por medidas de massa e a reprodutibilidade após quatro séries de irradiações por um irradiador de Cobalto-60 (CTR-IPEN). Após estas etapas, os dosímetros foram irradiados em um acelerador linear com energia de 6 MV (Serviço de Radioterapia Hospital Israelita Albert Einstein) para gerar os fatores de calibração individuais para cada dosímetro. Posteriormente, os dosímetros foram utilizados para as irradiações com a semente de iodo-125, modelo 6711 (GE-Healthcare). As irradiações com a semente de iodo-125 e demais análises renderam os valores necessários para a determinação dos parâmetros sugeridos pela AAPM (American Association of Physicists in Medicine): constante de taxa de dose, função de geometria, função de dose radial e função de anisotropia. Os resultados obtidos mostram boa concordância com os valores publicados pela literatura, para o mesmo modelo de semente de iodo-125, ratificando que os parâmetros realizados poderão ser utilizados para a dosimetria e controle de qualidade das sementes de iodo- 125 que irão ser produzidas pelo IPEN-CNEN/SP. / The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control.

Page generated in 0.0482 seconds