• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 9
  • 9
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Synthetic drain envelopes and soil particle distribution /

Broadhead, Richard Grant. January 1981 (has links)
Thesis (M.S.)--Ohio State University, 1981. / Includes bibliographical references (leaves 89-91). Available online via OhioLINK's ETD Center
2

The capacity of corrugated plastic tubing to support earth loads.

Bolduc, Gilles. January 1982 (has links)
No description available.
3

Laboratory testing of envelope materials for pipe drains

Rehman, Shafiq-ur January 1995 (has links)
Soils which were known to have caused sedimentation problems in drain pipes were used in the investigations. Different envelope combinations such as soil-fabric, soil-gravel and soil-sand-fabric were evaluated. Nine 100 mm diameter, 250 mm high permeameters were used to determine the functioning of envelope materials and to improve the criteria for testing of envelope materials. To obtain a clear indication of success/failure of an envelope, a wide range of hydraulic gradients and different thicknesses of soils and envelopes were used. The most effective thicknesses were, 5 cm of soil with fabrics and 2.5 cm of soil plus 7.5 cm of gravel for gravel envelopes. / All the fabrics were successful in retaining the soil particles. No clogging was observed and higher flow rates were measured in fabrics having 2 to 3 mm thicknesses with openings O$ sb{95}$ finer than 100 $ mu$m. / SCS criteria (1988) with the following modifications: $ rm D sb{100}0.3$ mm for gravel; and $ rm D sb{100}<9.5$ mm for crushed rock mixed with sand are suggested. The performance of envelopes meeting these criteria were successful. / The laboratory tests show that the use of a fabric with river sand as an envelope has a very good potential for successful field operation. There was no laboratory evidence to reject the functioning of this concept.
4

The capacity of corrugated plastic tubing to support earth loads.

Bolduc, Gilles. January 1982 (has links)
No description available.
5

Laboratory testing of envelope materials for pipe drains

Rehman, Shafiq-ur January 1995 (has links)
No description available.
6

Frictional losses of air flowing through plastic corrugated and PVC sewer pipe

Duarte-Massey, Jaime. January 1982 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1982. / Typescript. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 83-84).
7

The implementation of a Kanban system in a multi-facility organization with a shared tooling constraint

O'Grady, Erin L. January 2001 (has links)
Thesis (M.S.)--Ohio University, November, 2001. / Title from PDF t.p.
8

L'essai d'un nettoyeur de drains hydraulique

Laperrière, Lucie. January 1988 (has links)
No description available.
9

L'essai d'un nettoyeur de drains hydraulique

Laperrière, Lucie January 1988 (has links)
No description available.

Page generated in 0.0556 seconds