• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 20
  • 20
  • 20
  • 7
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Impacts of ozonation and membrane filtration on drinking water biostability and the effects of sample strorage on the assimilable organic carbon (AOC) bioassay

Escobar, Isabel Cristina 01 April 2000 (has links)
No description available.
12

Microbiological assessment of water quality and prevalence of waterborne diseases in rural areas of Masaka, Rwanda

Uwimpuhwe, Monique 28 May 2014 (has links)
Submitted in fulfilment of the requirements for the Master of Technology Degree: Environmental Health, Durban University of Technology, 2012. / Waterborne diseases represent substantial global burden of disease and children under the age of five are more susceptible to these diseases compared to adults. The aim of this study was to determine the microbiological quality of Nyabarongo River water used for domestic purposes, women’s knowledge, attitudes and practices (KAP) on water usage and waterborne diseases and its link to the diarrhoea outbreaks experienced in two rural communities: Rusheshe and Ayabaraya of Masaka in Rwanda. A total of 35water samples were collected from Nyabarongo River and from study households which used slow sand filtration (SSF) or Sûr’Eau as treatment methods and analyzed for total coliform and faecal coliform indicators. For household samples turbidity was also analyzed. Retrospective records from Masaka Health Centre were reviewed to determine the prevalence of waterborne diseases from the study areas during 2010. Further, a structured questionnaire was administered to 324 women residents of the study areas to elicit information on their KAP on water handling and waterborne diseases. SPSS Predictive Analytic Software (PASW) Statistics version 18.0 (IBM, Somers, NY) and STATA Release (Version 11.0, College Station, Texas USA) were used for data analysis. Results showed that the mean values of total and faecal coliforms of river and household water samples were above the WHO and Rwandan recommended guidelines. The mean values of total coliform and faecal coliform were significantly lower (p ≤ 0.05) in both filtered and Sûr’Eau treated water than in river water. No statistical differences of means were observed for both total coliform and faecal coliform counts between samples taken from filtered and Sûr’Eau treated water containers (p=0.80 (TC) and p = 0.56 (FC). However, turbidity values were significantly lower in filtered water using SSF than in Sûr’Eau treated water samples (p =0.002). Out of 2814 records form Masaka Health Centre during 2010, 160 cases were identified as having diarrhoeal diseases. Furthermore, respondents who used Nyabarongo River as source of water were more likely to have symptoms of diarrhoea (OR =5.35; CI: 2.12 - 14.46; p <0.05). The frequency of diarrhoea were significantly higher among people who did not wash hands before food preparation (p = 002) and after using a toilet (p = 0.007) than among those who did. There was a statistically significant association of level of education levels and drinking water treatment practices at the household level (p < 0.05). Respondents with primary school education only and those with high school education were more likely to wash their hands after using a toilet (OR= 5.24, CI 1.42-19.38, p =0.01 and OR = 7.15, CI = 1.79 -28.62, p=0.01, respectively) than those who did not attend school. No significant associations were identified between educational levels and washing hands before food preparation. The findings of this study points to the facts that water sourced from Nyabarongo River is unsafe for human consumption even after prescribed treatment, such as the use of SSF and Sûr’Eau, and could increase the prevalence of waterborne diseases and therefore calls for urgent provision of potable water. Women in the study areas had limited knowledge regarding water storage practices for prevention of household water contamination and this; underscore the need for more water handling practices and hygiene education in rural communities. / Durban University of Technology.
13

Endotoxins detection and control in drinking water systems

Parent Uribe, Santiago. January 2007 (has links)
Endotoxins are a constituent of the lipopolysaccharide (LPS) complexes present in the outer layer of the cell wall of most Gram-negative bacteria and some cyanobacteria. The ingestion by a typical adult of amounts exceeding 1,000 endotoxin units (EUs) can cause fever, diarrhoea, vomiting, acute respiratory illnesses, and lung inflammation. In contrast, much smaller doses may lead to protective immunity against allergic diseases. / Endotoxins can be released in the air as well as in the water; previous studies have mainly focused on airborne endotoxins. Although many studies on endotoxins in raw and treated drinking waters have been performed, few have assessed seasonal variations and none have been conducted in Eastern Canada. Furthermore, a clear understanding of removal of endotoxins by various water treatment processes is still required. / Two methods to measure the concentrations of endotoxin were used and compared, the Limulus Amebocyte Lysate test (LAL) and the recombinant Factor C test (rFC). Raw water samples were taken from various drinking water sources around the Island of Montreal. The effects of free chlorine, UV radiation, and ozone were studied in batch experiments on filtered water samples via typical dosages and fluences used in drinking water treatment facilities. Residual concentrations for free chlorine were 0.8 and 1.6 mg/L; ozone doses were 0.5 and 1 mg/L; UV fluences were 40 and 100 mWs/cm2. Detention times of 20 and 60 minutes were tested for chlorine and 5 and 20 minutes for ozone. Grab sampling from three drinking water treatment plants in the Montreal area was performed during the months of June and late August/September 2006 and January 2007. Processes at these plants include coagulation and flocculation, sand filtration, ozonation and disinfection by chlorine. To test the variation in endotoxin concentrations during a sand filter cycle, samples were withdrawn directly from a filter in one of the treatment plants studied. The filtration cycle, from one backwash to the next one, lasts 72 h. Samples were collected immediately before the backwash, at the beginning and at the end of the ripening period, at the beginning of the filtration cycle and 48 h later, which corresponds to a half cycle period. / Of the two endotoxin detection methods used, LAL consistently gave slightly higher values compared to rFC; rFC also required more expensive hardware, but the method was less tedious and reagent costs were lower. Results presented, unless otherwise stated, were obtained with the rFC method. Endotoxin levels decreased in raw water samples between June and September. Concentrations ranged from 20 to 30 EU/mL in June, and decreased to 10 to 14 EU/mL in August and beyond. For the disinfection processes, the UV and free chlorine doses tested had little or no effect on the endotoxin concentrations, but ozone reduced the concentrations by up to 75%. Sand filtration and flocculation showed significant endotoxin removal efficiencies (50--60%). Levels remained around 5 EU/mL throughout the remaining treatment processes regardless of the influent concentration. Hence, endotoxin inactivation by free chlorine and UV does not occur with typical doses used in drinking water treatment plants; in contrast, flocculation and sand filtration, as well as ozonation, are much more effective.
14

The development of functionalized electrospun nanofibers for the control of pathogenic microorganisms in water.

Kleyi, Phumelele Eldridge January 2014 (has links)
The thesis presents the development of functionalized electrospun nylon 6 nanofibers for the eradication of pathogenic microorganisms in drinking water. Imidazole derivatives were synthesized as the antimicrobial agents and were characterized by means of NMR spectroscopy, IR spectroscopy, elemental analysis and X-ray crystallography. The first set of compounds (2-substituted N-alkylimidazoles) consisted of imidazole derivatives substituted with different alkyl groups (methyl, ethyl, propyl, butyl, heptyl, octyl, decyl and benzyl) at the 1-position and various functional groups [carboxaldehyde (CHO), alcohol (CH2OH) and carboxylic acid (COOH)] at the 2-position. It was observed that the antimicrobial activity of the compounds increased with increasing alkyl chain length and decreasing pKa of the 2-substituent. It was also observed that the antimicrobial activity was predominantly against a Gram-positive bacterial strains [Staphylococcus aureus (MIC = 5-160 μg/mL) and Bacillus subtilis subsp. spizizenii (MIC = 5-20 μg/mL)], with the latter being the more susceptible. However, the compounds displayed poor antimicrobial activity against Gram-negative bacterial strain, E. coli (MIC = 150- >2500 μg/mL) and did not show any activity against the yeast, C. albicans. The second set of compounds consisted of the silver(I) complexes containing 2-hydroxymethyl-N-alkylimidazoles. The complexes displayed a broad spectrum antimicrobial activity towards the microorganisms that were tested and their activity [E. coli (MIC = 5-40 μg/mL), S. aureus (MIC = 20-80 μg/mL), Bacillus subtilis subsp. spizizenii (MIC = 5-40 μg/mL) and C. albicans (MIC = 40-80 μg/mL)] increased with the alkyl chain length of the 2-hydroxymethyl-N-alkylimidazole. The third set of compounds consisted of the vinylimidazoles containing the vinyl group either at the 1-position or at the 4- or 5- position. The imidazoles with the vinyl group at the 4- or 5-position contained the alkyl group (decyl) at the 1-position. For the fabrication of the antimicrobial nanofibers, the first two sets of imidazole derivatives (2-substituted N-alkylimidazoles and silver(I) complexes) were incorporated into electrospun nylon 6 nanofibers while the third set (2-substituted vinylimidazoles) was immobilized onto electrospun nylon 6 nanofibers employing the graft polymerization method. The antimicrobial nylon nanofibers were characterized by IR spectroscopy and SEM-EDAX (EDS). The electrospun nylon 6 nanofibers incorporated with 2-substituted N-alkylimidazoles displayed moderate to excellent levels of growth reduction against S. aureus (73.2-99.8 percent). For the electrospun nylon 6 nanofibers incorporated with silver(I) complexes, the levels of growth reduction were >99.99 percent, after the antimicrobial activity evaluation using the shake flask method. Furthermore, the grafted electrospun nylon 6 nanofibers showed excellent levels of growth reduction for E. coli (99.94-99.99 percent) and S. aureus (99.93-99.99 percent). The reusability results indicated that the grafted electrospun nylon 6 nanofibers maintained the antibacterial activity until the third cycle of useage. The cytotoxicity studies showed that grafted electrospun nylon 6 nanofibers possess lower cytotoxic effects on Chang liver cells with IC50 values in the range 23.48-26.81 μg/mL. The thesis demonstrated that the development of antimicrobial electrospun nanofibers, with potential for the eradication of pathogenic microoganisms in water, could be accomplished by incorporation as well as immobilization strategies.
15

Endotoxins detection and control in drinking water systems

Parent Uribe, Santiago. January 2007 (has links)
No description available.
16

A contribution towards real-time forecasting of algal blooms in drinking water reservoirs by means of artificial neural networks and evolutionary algorithms.

Welk, Amber Lee January 2008 (has links)
Historical water quality databases from two South Australian drinking water reservoirs were used, in conjunction with various computational modelling methods for the ordination, clustering and forecasting of complex ecological data. Techniques used throughout the study were: Kohonen artificial neural networks (KANN) for data categorisation and the discovery of patterns and relationships, recurrent supervised artificial neural networks (RANN) for knowledge discovery and forecasting of algal dynamics and hybrid evolutionary algorithms (HEA) for rule-set discovery and optimisation for forecasting algal dynamics. These methods were combined to provide an integrated approach to the analysis of algal populations including interactions within the algal community and with other water quality factors, which results in improved understanding and forecasting of algal dynamics. The project initially focussed on KANN for the patternising and classification of the historical data to reveal links between the physical, chemical and biological components of the reservoirs. This offered some understanding of the system and relationships being considered for the construction of the forecasting models. Specific investigations were performed to examine past conditions and the impacts of different management regimes, as well as to discover sets of conditions that correspond with specific algal functional groups. RANN was then used to build models for forecasting both Chl-a and the main nuisance species, Anabaena, up to 7 days in advance. This method also provided sensitivity analyses to demonstrate the relationship between input and output variables by plotting the reaction of the output to variations in the inputs. Initially one year from the data set was selected for the testing of a model, as per the split-sample technique. To further test the models, it was later decided to select several years for testing to ensure the models were useful under changed conditions, and that test results were not misleading regarding the models true capabilities. RANN were firstly used to create reservoir specific or ad-hoc models. Later, the models were trained with the merged data sets of both reservoirs to create one model that could be applied to either reservoir. Another method of forecasting was trialled and compared to RANN. HEA was found to be equal or superior to RANN in predictive power, also allowed sensitivity analysis and provided an explicit, portable rule set. The HEA rule sets were initially tested on selected years of data, however to fully demonstrate the models potential, a process for k-fold cross-validation was developed to test the rule-set on all years of data. To further extend the applicability of the HEA rule-set; the idea of rule-based agents for specific lake ecosystem categories was examined. The generality of a rule-based agent means that, after successful validation on several lakes from one category, the agent could then be applied to other water bodies from within that category that had not been involved in the training process. The ultimate test of the rule-based agent for the warm monomictic and eutrophic lake ecosystem category was to be applied to a real-time monitoring and forecasting situation. The agent was fed with online, real-time data from a reservoir that belonged to the same ecosystem category but was not used in the training process. These preliminary experiments showed promising results. It can be concluded that the concept of rulebased agents will facilitate real-time forecasting of algal blooms in drinking water reservoirs provided on-line monitoring of relevant variables has been implemented. Contributions of this research include: (1) to offer insight into the capabilities of 3 kinds of computational modelling techniques applied to complex water quality data, (2) novel applications of KANN including the division of data into separate management periods for comparison of management efficiency, (3) to both qualitatively and quantitatively elucidate relationships between water quality parameters, (4) research toward the development of a forecasting tool for algal abundance 7 days in advance that could be generic for a particular lake ecosystem category and implemented in real-time, and (5) to suggest a thorough testing method for such models (k-fold cross validation). / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1331584 / Thesis (Ph.D.) -- University of Adelaide, School of Earth and Environmental Sciences, 2008
17

Evaluating the post-implementation effectiveness of selected household water treatment technologies in rural Kenya

Onabolu, Boluwaji January 2014 (has links)
Water, sanitation and hygiene-related diseases are responsible for 7% of all deaths and 8% of all disability adjusted live years (DALYs), as well as the loss of 320 million days of productivity in developing countries. Though laboratory and field trials have shown that household water treatment (HWT) technologies can quickly improve the microbiological quality of drinking water, questions remain about the effectiveness of these technologies under real-world conditions. Furthermore, the value that rural communities attach to HWT is unknown, and it is not clear why, in spite of the fact that rural African households need household water treatment (HWT) most, they are the least likely to use them. The primary objective of this multi-level study was to assess the post-implementation effectiveness of selected HWT technologies in the Nyanza and Western Provinces of Kenya. The study was carried out in the rainy season between March and May, 2011 using a mixed method approach. Evidence was collected in order to build a case of evidence of HWT effectiveness or ineffectiveness in a post-implementation context. A quasi-experimental design was used first to conduct a Knowledge, Attitudes and Practices (KAP) survey in 474 households in ten intervention and five control villages (Chapter 3). The survey assessed the context in which household water treatment was being used in the study villages to provide real-world information for assessing the effectiveness of the technologies. An interviewer-administered questionnaire elicited information about the water, sanitation and hygiene-related KAP of the study communities. A household water treatment (HWT) survey (Chapter 4) was carried out in the same study households and villages as the KAP study, using a semi-structured questionnaire to gather HWT adoption, compliance and sustained use-related information to provide insight into the perceived value the study households attach to HWT technologies, and their likelihood of adoption of and compliance with these technologies. The drinking water quality of 171 (one quarter of those surveyed during KAP) randomly selected households was determined and tracked from source to the point of use (Chapter 5). This provided insights into HWT effectiveness by highlighting the need for HWT (as indicated by source water quality) and the effect of the study households’ KAP on drinking water quality (as indicated by the stored water quality). Physico-chemical and microbiological water quality of the nineteen improved and unimproved sources used by the study households was determined, according to the World Health Organisation guidelines. The microbiological quality of 291 water samples in six intervention and five control villages was determined from source to the point-of-use (POU) using the WHO and Sphere Drinking Water Quality Guidelines. An observational study design was then used to assess the post-implementation effectiveness of the technologies used in 37 households in five intervention villages (Chapter 6). Three assessments were carried out to determine the changes in the microbiological quality of 107 drinking water samples before treatment (from collection container) and after treatment (from storage container) by the households. The criteria used to assess the performance of the technologies were microbial efficacy, robustness and performance in relation to sector standards. A Quantitative Microbial Risk Assessment (QMRA) was then carried out in the HWT effectiveness study households to assess the technologies’ ability to reduce the users’ exposure to and probability of infection with water-borne pathogens (Chapter 7). The KAP survey showed that the intervention and control communities did not differ significantly in 18 out of 20 socio-economic variables that could potentially be influenced by the structured manner of introducing HWT into the intervention villages. The majority of the intervention group (IG) and the control group (CG) were poor or very poor on the basis of household assets they owned. The predominant level of education for almost two-thirds of the IG and CG respondents was primary school (completed and non-completed). Though very few were unemployed in IG (8.07%) and CG (14.29%), the two groups of respondents were predominantly engaged in subsistence farming — a low income occupation. With regard to practices, both groups had inadequate access to water and sanitation with only one in two of the households in both IG and CG using improved water sources as their main drinking water source in the non-rainy season. One in ten households in both study groups possessed an improved sanitation facility, though the CG was significantly more likely to practice open defecation than the IG. The self-reported use of soap in both study groups was mainly for bathing and not for handwashing after faecal contact with adult or child faeces. Despite the study groups' knowledge about diarrhoea, both groups showed a disconnection between their knowledge about routes of contamination and barriers to contamination. The most frequent reason for not treating water was the perceived safety of rain water in both the IG and CG. / The HWT adoption survey revealed poor storage and water-handling practices in both IG and CG, and that very few respondents knew how to use the HWT technologies correctly: The IG and CG were similar in perceived value attached to household water treatment. All HWT technologies had a lower likelihood of adoption compared to the likelihood of compliance indicators in both IG and CG. The users’ perceptions about efficacy, time taken and ease of use of the HWT technologies lowered the perceived value attached to the technologies. The assessment of the drinking water quality used by the study communities indicated that the improved sources had a lower geometric mean E. coli and total coliform count than the unimproved sources. Both categories of sources were of poor microbiological quality and both exceeded the Sphere Project (2004) and the WHO (2008) guidelines for total coliforms and E. Coli respectively The study communities’ predominant drinking water sources, surface water and rainwater were faecally contaminated (geometric mean E. coli load of 388.1±30.45 and 38.9±22.35 cfu/100 ml respectively) and needed effective HWT. The improved sources were significantly more likely than the unimproved sources to have a higher proportion of samples that complied with the WHO drinking water guidelines at source, highlighting the importance of providing improved water sources. The lowest levels of faecal contamination were observed between the collection and storage points which coincided with the stage at which HWT is normally applied, suggesting an HWT effect on the water quality. All water sources had nitrate and turbidity levels that exceeded the WHO stipulated guidelines, while some of the improved and unimproved sources had higher than permissible levels of lead, manganese and aluminium. The water source category and the mouth type of the storage container were predictive of the stored water quality. The active treater households had a higher percentage of samples that complied with WHO water quality guidelines for E. coli than inactive treater households in both improved and unimproved source categories. In inactive treater households, 65% of storage container water samples from the improved sources complied with the WHO guidelines in comparison to 72% of the stored water samples in the active treater households. However the differences were not statistically significant. The HWT technologies did not attain sector standards of effective performance: in descending order, the mean log10 reduction in E. coli concentrations after treatment of water from unimproved sources was PUR (log₁₀ 2.0), ceramic filters (log₁₀ 1.57), Aquatab (log₁₀ 1.06) and Waterguard (log₁₀ 0.44). The mean log10 reduction in E. coli after treatment of water from improved sources was Aquatab (log₁₀ 2.3), Waterguard (log₁₀ 1.43), PUR (log₁₀ 0.94) and ceramic filters (log₁₀ 0.16). The HWT technologies reduced the user’s daily exposure to water-borne pathogens from both unimproved and improved drinking water sources. The mean difference in exposure after treatment of water from unimproved sources was ceramic filter (log₁₀ 2.1), Aquatab (log₁₀ 1.9), PUR (log₁₀ 1.5) and Waterguard (log₁₀ 0.9), in descending order. The mean probability of infection with water-borne pathogens (using E.coli as indicator) after consumption of treated water from both improved and unimproved sources was reduced in users of all the HWT technologies. The difference in reduction between technologies was not statistically significant. The study concluded that despite the apparent need for HWT, the study households’ inadequate knowledge, poor attitudes and unhygienic practices make it unlikely that they will use the technologies effectively to reduce microbial concentrations to the standards stipulated by accepted drinking water quality guidelines. The structured method of HWT promotion in the intervention villages had not resulted in more hygienic water and sanitation KAP in the IG compared to the CG, or significant differences in likelihood of adoption and compliance with the assessed HWT technologies. Despite attaching a high perceived value to HWT, insufficient knowledge about how to use the HWT technologies and user concerns about factors such as ease of use, accessibility and time to use will impact negatively on adoption and compliance with HWT, notwithstanding their efficacy during field trials. Even though external support had been withdrawn, the assessed HWT technologies were able improve the quality of household drinking water and reduce the exposure and risk of water-borne infections. However, the improvement in water quality and reduction in risk did not attain sector guidelines, highlighting the need to address the attitudes, practices and design criteria identified in this study which limit the adoption, compliance and effective use of these technologies. These findings have implications for HWT interventions, emphasising the need for practice-based behavioural support alongside technical support.
18

Evaluating the Impacts of Sustainable Water Use Measures on Drinking Water Microbiology and Chemistry

Christiane J Ley (11199507) 29 July 2021 (has links)
<div>This dissertation focused on examining the potential unintended consequences of sustainability on drinking water quality at the tap. The rising trend in water conservation awareness has given rise to the use of water-efficient appliances and fixtures for residential potable water systems. The first study (Chapter 1) characterized the microbial dynamics at a water-efficient residential building over the course of one year and examined the effects of water stagnation, season, and changes in physicochemical properties on the occurrence of opportunistic pathogen markers. When rainwater harvesting is utilized as an alternative water resource in buildings, a combination of municipal water and rainwater is typically required to meet water demands. However, altering source water chemistry can disrupt pipe scale and biofilm and negatively impact water quality at the distribution level. The second study (Chapter 2) in this dissertation evaluated the potential water quality consequences of using intermittent supplies of municipal water and rainwater within building plumbing systems. Cross-linked polyethylene (PEX) pipes are considered by some to be more sustainable than copper pipes and are commonly installed in building plumbing. The goal of the third study (Chapter 3) was to better understand chemical release from commercially available PEX pipes, to characterize toxicological characteristics of the contact water, and to compare microbial growth potential among the three pipe types. During the COVID-19 pandemic, many commercial and office buildings were closed for extended periods of time, allowing water age to increase over the course of several months. Heightened water age is often associated with an increase in chemical and microbial contamination. The objective of the fourth study (Chapter 4) was to evaluate the impacts of an extended COVID-19 related building closure and stagnation on water quality. The goal of this study was to evaluate the efficacy of flushing and shock chlorination remediation strategies on water quality at the tap. </div><div><br></div><div>This dissertation contains four chapters and each chapter is a single manuscript. The first two chapters have been published.</div><div><br></div><div>“Drinking water microbiology in a water-efficient building: Stagnation, seasonality, and physiochemical effects on opportunistic pathogen and total bacteria proliferation.” (Chapter 1) Utilizing a residential building that had been retrofitted with low-flow fixtures, the unintended water quality consequences of increased stagnation in low-flow plumbing were evaluated over a year long period. The study results indicated that microbial growth and potential opportunistic pathogen markers, Legionella and Mycobacterium spp. were detected at higher levels within the home as compared to the municipal water main. Reduced water usage induced longer stagnation times and longer stagnation times were correlated with an increase in Legionella spp., Mycobacterium spp., and total cell counts.</div><div><br></div><div>“Impacts of Municipal Water−Rainwater Source Transitions on Microbial and Chemical Water Quality Dynamics at the Tap.” (Chapter 2) Altering source water chemistry can disrupt pipe scale and biofilm and negatively impact water quality at the distribution level. Still, it is unknown if similar reactions occur within building plumbing following a transition in source water quality. To date, no prior studies had evaluated the water quality impacts of transitioning between rainwater and municipal groundwater sources in low-flow plumbing. The study revealed that influent water chemistry impacted rates of metal release from plumbing. Because of differences in source water treatment and water chemistry, rainwater and municipal water uniquely interacted with building plumbing and generated distinctively different drinking water chemical and microbial quality profiles. </div><div><br></div><div>“Contaminant Leaching and Toxicological Assessment of Drinking Water in Contact with Cross-linked Polyethylene (PEX) Pipes.” (Chapter 3) Cross-linked polyethylene (PEX) plastic water pipes are increasingly being installed instead of copper pipes for conventional and green building construction. Unlike metal pipe, PEX pipe is easier to install and not vulnerable to corrosion. However, potential health concerns associated with PEX pipe are: 1.) the organic contaminant release that occurs during its service-life, 2.) increased microbial growth compared to metal pipes, and 3.) compound toxicity. Our study goal was to better understand chemical release from commercially available PEX pipes, to characterize toxicological characteristics of the contact water, and to compare microbial growth potential among the three pipe types at varying chlorine concentrations. Results indicated that PEX contact waters did not affect the neurobehavioral development of zebrafish, but affected development in the zebrafish model. Further studies should be conducted to determine how influent water chemistry impacts carbon migration and the water’s toxicity.</div><div><br></div><div>“Water quality during the COVID-19 pandemic: The role of flushing and shock chlorination strategies in reducing building water problems.” (Chapter 4) The COVID-19 pandemic led to widespread “stay at home” orders across the United States. As a result, many office buildings, schools, and commercial buildings were left empty, allowing water age within the plumbing to increase dramatically. Heightened stagnation and water age can lead to increased metal leaching from pipe walls, as well as increases in microbial growth and opportunistic pathogen proliferation. Water quality in a large school building was monitored after approximately six months of being closed due to COVID-19 related restrictions. Upon sampling the building, chemical and microbial water quality indicators were affected by the initial six month stagnation period. To monitor the relationship between shock chlorination and water quality at the tap, samples were collected at fixtures at different time points to gain a better understanding of the effects of shock disinfection on drinking water chemistry and microbiology. This study raises concerns with respect to the impact of extended building closures on drinking water quality and the best approach to remediate and monitor water quality issues thereafter.</div>
19

Quality of drinking water sources in the Bloemfontein area of the Mangaung Metropolitan Municipality

Ratikane, Mosepeli January 2013 (has links)
Thesis (M. Tech. (Environmental Health)) -- Central University of technology, Free State, 2013 / Introduction: Drinking water of poor quality can cause a variety of diseases and may even result in death. The impact of poor drinking water is a course for concern even in South Africa. Therefore, the physical, chemical and microbiological drinking water quality was investigated in the peri-urban area of Bainsvlei and the Woodlands Hills Estate in Bloemfontein, Free State. Materials and Methods: The water quality was assessed in 20 identified sampling sites for three series with ten weeks apart. These sites use treated municipal and untreated borehole water for drinking. The determinants analysed for were pH, electrical conductivity (EC), turbidity, temperature, Ca, Mg, Na, F, Cl, N, SO₄,N, Free chlorine, Al, As, CN, Fe, Mn, Pb, Hg, total coliforms and E. coli. The water samples were collected and analysed on site and in the laboratory. Both the physical and chemical determinants were measured using standard methods whereas the microbiological determinants were measured using the Defined Substrate Technology (DST) method. The measurements were first compared to the SANS 241 (2011) for compliance. The ANOVA tests were used to investigate if any seasonal variations existed in the water quality as well as to compare the levels of the determinants between borehole and municipal water. In the assessment of the overall drinking water quality of different water sampling sites the water quality index (WQI) was used. Results and Discussions: Significant effects were believed to exist if the p-values of the ANOVA and Scheffe tests were at a significance level of 5% (p < 0.05). The study results revealed that of the four physical determinants that were measured turbidity exceeded the standard in many sampling sites in the three series. Of all the chemical determinants, nitrates exceeded the standard. In the same way coliforms exceeded the standard in a number of sampling sites while E. coli was found in a few sampling sites in the first series. ANOVA tests revealed that seasonal variations existed between pH, EC, temperature, cyanide and iron at a significant level of 5% (p < 0.05) while the Post-hoc Scheffe test further revealed the series in which the effect existed. Similarly, the ANOVA tests revealed that the levels of the determinants between municipal versus borehole varied in pH, EC, Ca, Mg, Na, F, Cl, N, and SO₄ at a significant level of 5% (p < 0.05). The WQI showed that in all the series when combining the good and excellent category season 2 had the highest percentage of 80%, followed by season 3 with 79% and season 1 with 70%. Only borehole sampling sites were found in the poor, very poor and unsuitable categories. Similarly all the highest WQI values were found in borehole sampling sites. Conclusion: This study revealed that the water quality is of good quality in the Bainsvlei and Woodlands Hills Estate of the Mangaung metropolitan municipality in Bloemfontein, in the Free State, South Africa. The presence of E. coli, though found in a few sampling sites and the high levels of turbidity, nitrates and coliforms are of concern to public health.
20

Is the shelf life of bottled water a cause for concern?

Liee, Yvone Lieketseng 08 1900 (has links)
Thesis. (M. Tech (Biotechnology, Faculty of Applied and Computer Science))--Vaal University of Technology, 2011. / Bottled water like any drinking water used for human consumption should be safe and wholesome to ensure adequate public health protection. This is due to potential health effects of concern such as endocrine disruption, toxicity teratogenicity, mutagenicity and carcinogenicity. Despite the number of regulatory bodies, publications on bottled water and speculations on its public health significance, many questions remain to be answered. One of the questions is whether the shelf life of bottled water is a cause for concern. The aim of the study was to determine the shelf-life of various commercial bottled waters by monitoring the variation in microbiological, chemical and aesthetic qualities of bottled water. A total of five commercial bottled water brands (A, B, C, D, E) each containing bottles from the same batch consisting of spring water, mineral water and bottled tap water were purchased directly after being bottled from different distributors around Gauteng in South Africa. All samples were stored at room temperature with artificial lighting and controlled temperature for a year thus mimicking typical conditions in retail outlets, supermarkets and in homes. Analyses were conducted over a period of 12 months, at monthly intervals. Within days of being purchased, high Heterotrophic plate counts (HPC) bacteria exceeding drinking water alert level >5 000 cfu/ml was common in four bottled water brands. Growth succession occurred during the period of study as various algal species were growing and accumulating on all bottled water tested. Total coliforms (TC), faecal coliforms (FC) and E.coli were not detected in all the bottled water tested. Yeasts and moulds were also not detected in all the bottled water. There were insignificant variations during the period of study for turbidity, pH, TDS, conductivity, and colour. These did not indicate any potential impact on aesthetic quality of bottled water. Two bottled water brands had hardness measures as low as 11mg/ℓ as CaCO3 making the water too soft which has an effect on taste. Radioactive substances, trihalomethanes, heavy metals, pesticides and other chemical contaminants were not found at levels that can be detrimental to human health.

Page generated in 0.0924 seconds