• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 512
  • 90
  • 62
  • 51
  • 41
  • 34
  • 13
  • 9
  • 6
  • 6
  • 6
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 1044
  • 1044
  • 183
  • 178
  • 178
  • 163
  • 98
  • 83
  • 82
  • 80
  • 73
  • 68
  • 66
  • 64
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Reducing Lead and Selenium from Drinking Water Using Limestone-based Material

Tumati, Sindhu 01 May 2012 (has links)
Contamination of drinking water with metals is a major problem facing many areas of United States and the World. There is a need for an inexpensive remediation technology for the removal of metals in drinking water that can be applied to small rural water systems. This research will focus on the development of a process for removal of select metals from drinking water by limestone-based material. Metals in drinking water considered for this research include lead and selenium. Limestone-based material has demonstrated the potential to reduce select metals (lead, cadmium and arsenic) in drinking water, with the additional benefit of low-cost disposal of a stable waste product in ordinary landfills. Earlier research by the principal investigators using limestone-based material for drinking water treatment has clearly shown that this material can achieve metals removal of greater than 90 percent. This project will investigate techniques to improve removal efficiency of limestone-based material through adsorption and precipitation. This research will assist in the development of a granular adsorbent product that will remove metals and that can be manufactured and sold for use at the drinking water source, at point-of-use, or at point-of entry.
202

An Integrated Design Approach for Improving Drinking Water Ozone Disinfection Treatment Based on Computational Fluid Dynamics

Zhang, Jianping 05 December 2006 (has links)
Ozonation is currently considered as one of the most effective microbial disinfection technologies due to its powerful disinfection capacity and reduction in levels of chlorinated disinfection by-products (DBP). However, ozonation of waters containing bromide can produce bromate ion above regulated levels, leading to tradeoffs between microbial and chemical risks. In efforts to meet increasingly stringent drinking water regulations and to be cost-effective, water suppliers are required to optimize ozone dosage. Therefore, there is a need to develop a robust and flexible tool to accurately describe ozone disinfection processes and contribute to their design and operation. Computational fluid dynamics (CFD) has come into use recently for evaluating disinfection systems. However, the focus of its application has been largely on modelling the hydraulic behaviour of contactors, which is only one component of system design. The significance of this dissertation is that a fully comprehensive three dimensional (3D) multiphase CFD model has been developed to address all the major components of ozone disinfection processes: contactor hydraulics, ozone mass transfer, ozone decay, and microbial inactivation. The model was validated using full-scale experimental data, including tracer test results and ozone profiles from full-scale ozone contactors in two Canadian drinking water treatment plants (WTPs): the DesBaillets WTP in Montréal, Quebec and the Mannheim WTP in Kitchener, Ontario. Good agreement was observed between the numerical simulation and experimental data. The CFD model was applied to investigate ozone contactor performance at the DesBaillets WTP. The CFD-predicted flow fields showed that recirculation zones and short circuiting existed in the DesBaillets contactors. The simulation results suggested that additional baffles could be installed to increase the residence time and improve disinfection efficiency. The CFD model was also used to simulate ozone contactor performance at the Mannheim Water Treatment Plant before and after installing new liquid oxygen (LOX) ozone generators and removing some diffusers from the system. The modelling results indicated that such changes led to an increase in effective residence time, and therefore an adjustment to operational parameters was required after system modification. Another significant contribution is that, for the first time, the Eulerian and Lagrangian (or particle tracking) approaches, two commonly utilized methods for predicting microbial inactivation efficiency have been compared for the study of ozone disinfection processes. The modelling results of two hypothetical ozone reactors and a full scale contactor suggested that the effective CT values predicted by the Lagriangian approach were slightly lower than those obtained from the Eulerian approach but their differences were within 10%. Therefore, both approaches can be used to predict ozone disinfection efficiency. For the full scale contactor investigated, the tracer residence time distribution predicted by the Euerlian approach provided a better fit to the experimental results, which indicated that the Eulerian approach might be more suitable for the simulation of chemical tracer performance. The results of this part of work provided important insight in understanding the complex performance of multiphase ozonation systems and played an important role in further improving CFD modelling approaches for full-scale ozone disinfection systems. The third significant contribution of this work is that a CFD model was applied to illustrate the importance of ozone residual monitoring locations and suggest an improved strategy for ozone residual monitoring. For the DesBaillets ozone contactors, the CFD modelling results showed that ozone residuals in the cross section of the outlets of some contactor chambers differed by an order of magnitude. The “optimal” area of monitoring locations however varied at different operational conditions. Therefore, it was suggested that multiple ozone residual sampling points should be installed based on CFD analysis and experimental studies, to provide more accurate indicators to system operators. The CFD model was also used to study the factors affecting the residence time distribution (RTD). The results suggested that the selection of the tracer injection locations as well as tracer sampling locations might affect the RTD prediction or measurement. The CFD-predicted T10 values at different outlet locations varied by more than 10% variation. It is therefore recommended that CFD modelling be used to determine tracer test strategy before conducting a full-scale tracer test, and multiple sampling points should be employed during tracer tests, if possible. In addition, a research based on full-scale investigation has also been done to compare the three different CT prediction approaches: CT10, integrated disinfection design framework (IDDF), and CFD, to determine the most appropriate method for design and operation of ozone systems. The CFD approach yielded more accurate predictions of inactivation efficacy than the other two approaches. The current results also suggested that the differences in the three approaches in CT predictions became smaller at higher contactor T10/T ratios conditions as the contactors performed more closely to ideal plug flow reactors. This study has demonstrated that the computational fluid dynamics (CFD) approach is an efficient tool for improving ozone disinfection performance of existing water treatment plants and designing new ozonation systems. The model developed in this study can be used for ozone contactor design, evaluation, and troubleshooting. It can also be used as a virtual experimental tool to optimize ozone contactor behaviour under varying water quality and operational conditions.
203

An Integrated Design Approach for Improving Drinking Water Ozone Disinfection Treatment Based on Computational Fluid Dynamics

Zhang, Jianping 05 December 2006 (has links)
Ozonation is currently considered as one of the most effective microbial disinfection technologies due to its powerful disinfection capacity and reduction in levels of chlorinated disinfection by-products (DBP). However, ozonation of waters containing bromide can produce bromate ion above regulated levels, leading to tradeoffs between microbial and chemical risks. In efforts to meet increasingly stringent drinking water regulations and to be cost-effective, water suppliers are required to optimize ozone dosage. Therefore, there is a need to develop a robust and flexible tool to accurately describe ozone disinfection processes and contribute to their design and operation. Computational fluid dynamics (CFD) has come into use recently for evaluating disinfection systems. However, the focus of its application has been largely on modelling the hydraulic behaviour of contactors, which is only one component of system design. The significance of this dissertation is that a fully comprehensive three dimensional (3D) multiphase CFD model has been developed to address all the major components of ozone disinfection processes: contactor hydraulics, ozone mass transfer, ozone decay, and microbial inactivation. The model was validated using full-scale experimental data, including tracer test results and ozone profiles from full-scale ozone contactors in two Canadian drinking water treatment plants (WTPs): the DesBaillets WTP in Montréal, Quebec and the Mannheim WTP in Kitchener, Ontario. Good agreement was observed between the numerical simulation and experimental data. The CFD model was applied to investigate ozone contactor performance at the DesBaillets WTP. The CFD-predicted flow fields showed that recirculation zones and short circuiting existed in the DesBaillets contactors. The simulation results suggested that additional baffles could be installed to increase the residence time and improve disinfection efficiency. The CFD model was also used to simulate ozone contactor performance at the Mannheim Water Treatment Plant before and after installing new liquid oxygen (LOX) ozone generators and removing some diffusers from the system. The modelling results indicated that such changes led to an increase in effective residence time, and therefore an adjustment to operational parameters was required after system modification. Another significant contribution is that, for the first time, the Eulerian and Lagrangian (or particle tracking) approaches, two commonly utilized methods for predicting microbial inactivation efficiency have been compared for the study of ozone disinfection processes. The modelling results of two hypothetical ozone reactors and a full scale contactor suggested that the effective CT values predicted by the Lagriangian approach were slightly lower than those obtained from the Eulerian approach but their differences were within 10%. Therefore, both approaches can be used to predict ozone disinfection efficiency. For the full scale contactor investigated, the tracer residence time distribution predicted by the Euerlian approach provided a better fit to the experimental results, which indicated that the Eulerian approach might be more suitable for the simulation of chemical tracer performance. The results of this part of work provided important insight in understanding the complex performance of multiphase ozonation systems and played an important role in further improving CFD modelling approaches for full-scale ozone disinfection systems. The third significant contribution of this work is that a CFD model was applied to illustrate the importance of ozone residual monitoring locations and suggest an improved strategy for ozone residual monitoring. For the DesBaillets ozone contactors, the CFD modelling results showed that ozone residuals in the cross section of the outlets of some contactor chambers differed by an order of magnitude. The “optimal” area of monitoring locations however varied at different operational conditions. Therefore, it was suggested that multiple ozone residual sampling points should be installed based on CFD analysis and experimental studies, to provide more accurate indicators to system operators. The CFD model was also used to study the factors affecting the residence time distribution (RTD). The results suggested that the selection of the tracer injection locations as well as tracer sampling locations might affect the RTD prediction or measurement. The CFD-predicted T10 values at different outlet locations varied by more than 10% variation. It is therefore recommended that CFD modelling be used to determine tracer test strategy before conducting a full-scale tracer test, and multiple sampling points should be employed during tracer tests, if possible. In addition, a research based on full-scale investigation has also been done to compare the three different CT prediction approaches: CT10, integrated disinfection design framework (IDDF), and CFD, to determine the most appropriate method for design and operation of ozone systems. The CFD approach yielded more accurate predictions of inactivation efficacy than the other two approaches. The current results also suggested that the differences in the three approaches in CT predictions became smaller at higher contactor T10/T ratios conditions as the contactors performed more closely to ideal plug flow reactors. This study has demonstrated that the computational fluid dynamics (CFD) approach is an efficient tool for improving ozone disinfection performance of existing water treatment plants and designing new ozonation systems. The model developed in this study can be used for ozone contactor design, evaluation, and troubleshooting. It can also be used as a virtual experimental tool to optimize ozone contactor behaviour under varying water quality and operational conditions.
204

Iron: From Synthesis, Characterization, and Application of Sulfide Green Rust to Viability in Arsenic Water Treatment

Jones, Christopher 16 September 2013 (has links)
Iron chemistry plays an important role in our world. At the nanoscale, iron oxide nanoparticles (nanomagnetite) have many inherent physical or chemical characteristics that drive potential solutions to real-world problems; appropriation of nanomagnetite’s properties as a “scaffold” for chemistry would further enhance its effectiveness in applications. In an effort to make use of nanomagnetite’s physical properties, a new “Sulfide Green Rust” (sGR) has been synthesized from magnetic iron nanoparticles. The material is crystalline, reactive due to high iron(II) content, and dissolves in the aqueous phase. Nanomagnetite’s magnetic properties were also observed to persist after sGR synthesis. X-ray absorption spectroscopy (XAS) confirmed the synthesis of this new FeS2-like material. The crystallinity, composition, and various physical characteristics were examined using a host of techniques including X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), Mössbauer spectroscopy, CRYO-TEM, Raman spectroscopy, and ultraviolet-to-visible (UV-Vis) spectroscopy. To demonstrate its use, the material was then subjected to a test of its reactive potential, namely water remediation of an orange dye contaminant. Iron serves a function at the macroscale as well regarding water treatment, since iron coagulation-filtration is the industry standard for arsenic treatment. Determining a technology’s merit as a solution goes beyond technical concern, however, as environmental and economic aspects also play important roles. Life Cycle Analysis, or LCA, methodology works to holistically compare each of these facets from cradle to grave. To address the current arsenic drinking water requirements at a case setting in Hungary, the LCA technique was applied on two example arsenic removal technologies, both coagulation-filtration and adsorption. 9 out of 10 considered impact categories tended to favour coagulation-filtration in this small municipality study, however realistic variations in water chemistry and product characteristics led to some overlap of their environmental impact. Electricity did not have a large direct impact, regeneration of the adsorption technology was very costly, and adsorption’s hazardous waste was not reduced compared to coagulation-filtration. Coagulation-filtration is also the cheaper of the two technologies; its highest cost is that of waste disposal, while the highest single expense modeled is that of adsorption media cost.
205

An Integrated Design Approach for Improving Drinking Water Ozone Disinfection Treatment Based on Computational Fluid Dynamics

Zhang, Jianping 05 December 2006 (has links)
Ozonation is currently considered as one of the most effective microbial disinfection technologies due to its powerful disinfection capacity and reduction in levels of chlorinated disinfection by-products (DBP). However, ozonation of waters containing bromide can produce bromate ion above regulated levels, leading to tradeoffs between microbial and chemical risks. In efforts to meet increasingly stringent drinking water regulations and to be cost-effective, water suppliers are required to optimize ozone dosage. Therefore, there is a need to develop a robust and flexible tool to accurately describe ozone disinfection processes and contribute to their design and operation. Computational fluid dynamics (CFD) has come into use recently for evaluating disinfection systems. However, the focus of its application has been largely on modelling the hydraulic behaviour of contactors, which is only one component of system design. The significance of this dissertation is that a fully comprehensive three dimensional (3D) multiphase CFD model has been developed to address all the major components of ozone disinfection processes: contactor hydraulics, ozone mass transfer, ozone decay, and microbial inactivation. The model was validated using full-scale experimental data, including tracer test results and ozone profiles from full-scale ozone contactors in two Canadian drinking water treatment plants (WTPs): the DesBaillets WTP in Montréal, Quebec and the Mannheim WTP in Kitchener, Ontario. Good agreement was observed between the numerical simulation and experimental data. The CFD model was applied to investigate ozone contactor performance at the DesBaillets WTP. The CFD-predicted flow fields showed that recirculation zones and short circuiting existed in the DesBaillets contactors. The simulation results suggested that additional baffles could be installed to increase the residence time and improve disinfection efficiency. The CFD model was also used to simulate ozone contactor performance at the Mannheim Water Treatment Plant before and after installing new liquid oxygen (LOX) ozone generators and removing some diffusers from the system. The modelling results indicated that such changes led to an increase in effective residence time, and therefore an adjustment to operational parameters was required after system modification. Another significant contribution is that, for the first time, the Eulerian and Lagrangian (or particle tracking) approaches, two commonly utilized methods for predicting microbial inactivation efficiency have been compared for the study of ozone disinfection processes. The modelling results of two hypothetical ozone reactors and a full scale contactor suggested that the effective CT values predicted by the Lagriangian approach were slightly lower than those obtained from the Eulerian approach but their differences were within 10%. Therefore, both approaches can be used to predict ozone disinfection efficiency. For the full scale contactor investigated, the tracer residence time distribution predicted by the Euerlian approach provided a better fit to the experimental results, which indicated that the Eulerian approach might be more suitable for the simulation of chemical tracer performance. The results of this part of work provided important insight in understanding the complex performance of multiphase ozonation systems and played an important role in further improving CFD modelling approaches for full-scale ozone disinfection systems. The third significant contribution of this work is that a CFD model was applied to illustrate the importance of ozone residual monitoring locations and suggest an improved strategy for ozone residual monitoring. For the DesBaillets ozone contactors, the CFD modelling results showed that ozone residuals in the cross section of the outlets of some contactor chambers differed by an order of magnitude. The “optimal” area of monitoring locations however varied at different operational conditions. Therefore, it was suggested that multiple ozone residual sampling points should be installed based on CFD analysis and experimental studies, to provide more accurate indicators to system operators. The CFD model was also used to study the factors affecting the residence time distribution (RTD). The results suggested that the selection of the tracer injection locations as well as tracer sampling locations might affect the RTD prediction or measurement. The CFD-predicted T10 values at different outlet locations varied by more than 10% variation. It is therefore recommended that CFD modelling be used to determine tracer test strategy before conducting a full-scale tracer test, and multiple sampling points should be employed during tracer tests, if possible. In addition, a research based on full-scale investigation has also been done to compare the three different CT prediction approaches: CT10, integrated disinfection design framework (IDDF), and CFD, to determine the most appropriate method for design and operation of ozone systems. The CFD approach yielded more accurate predictions of inactivation efficacy than the other two approaches. The current results also suggested that the differences in the three approaches in CT predictions became smaller at higher contactor T10/T ratios conditions as the contactors performed more closely to ideal plug flow reactors. This study has demonstrated that the computational fluid dynamics (CFD) approach is an efficient tool for improving ozone disinfection performance of existing water treatment plants and designing new ozonation systems. The model developed in this study can be used for ozone contactor design, evaluation, and troubleshooting. It can also be used as a virtual experimental tool to optimize ozone contactor behaviour under varying water quality and operational conditions.
206

An Integrated Design Approach for Improving Drinking Water Ozone Disinfection Treatment Based on Computational Fluid Dynamics

Zhang, Jianping 05 December 2006 (has links)
Ozonation is currently considered as one of the most effective microbial disinfection technologies due to its powerful disinfection capacity and reduction in levels of chlorinated disinfection by-products (DBP). However, ozonation of waters containing bromide can produce bromate ion above regulated levels, leading to tradeoffs between microbial and chemical risks. In efforts to meet increasingly stringent drinking water regulations and to be cost-effective, water suppliers are required to optimize ozone dosage. Therefore, there is a need to develop a robust and flexible tool to accurately describe ozone disinfection processes and contribute to their design and operation. Computational fluid dynamics (CFD) has come into use recently for evaluating disinfection systems. However, the focus of its application has been largely on modelling the hydraulic behaviour of contactors, which is only one component of system design. The significance of this dissertation is that a fully comprehensive three dimensional (3D) multiphase CFD model has been developed to address all the major components of ozone disinfection processes: contactor hydraulics, ozone mass transfer, ozone decay, and microbial inactivation. The model was validated using full-scale experimental data, including tracer test results and ozone profiles from full-scale ozone contactors in two Canadian drinking water treatment plants (WTPs): the DesBaillets WTP in Montréal, Quebec and the Mannheim WTP in Kitchener, Ontario. Good agreement was observed between the numerical simulation and experimental data. The CFD model was applied to investigate ozone contactor performance at the DesBaillets WTP. The CFD-predicted flow fields showed that recirculation zones and short circuiting existed in the DesBaillets contactors. The simulation results suggested that additional baffles could be installed to increase the residence time and improve disinfection efficiency. The CFD model was also used to simulate ozone contactor performance at the Mannheim Water Treatment Plant before and after installing new liquid oxygen (LOX) ozone generators and removing some diffusers from the system. The modelling results indicated that such changes led to an increase in effective residence time, and therefore an adjustment to operational parameters was required after system modification. Another significant contribution is that, for the first time, the Eulerian and Lagrangian (or particle tracking) approaches, two commonly utilized methods for predicting microbial inactivation efficiency have been compared for the study of ozone disinfection processes. The modelling results of two hypothetical ozone reactors and a full scale contactor suggested that the effective CT values predicted by the Lagriangian approach were slightly lower than those obtained from the Eulerian approach but their differences were within 10%. Therefore, both approaches can be used to predict ozone disinfection efficiency. For the full scale contactor investigated, the tracer residence time distribution predicted by the Euerlian approach provided a better fit to the experimental results, which indicated that the Eulerian approach might be more suitable for the simulation of chemical tracer performance. The results of this part of work provided important insight in understanding the complex performance of multiphase ozonation systems and played an important role in further improving CFD modelling approaches for full-scale ozone disinfection systems. The third significant contribution of this work is that a CFD model was applied to illustrate the importance of ozone residual monitoring locations and suggest an improved strategy for ozone residual monitoring. For the DesBaillets ozone contactors, the CFD modelling results showed that ozone residuals in the cross section of the outlets of some contactor chambers differed by an order of magnitude. The “optimal” area of monitoring locations however varied at different operational conditions. Therefore, it was suggested that multiple ozone residual sampling points should be installed based on CFD analysis and experimental studies, to provide more accurate indicators to system operators. The CFD model was also used to study the factors affecting the residence time distribution (RTD). The results suggested that the selection of the tracer injection locations as well as tracer sampling locations might affect the RTD prediction or measurement. The CFD-predicted T10 values at different outlet locations varied by more than 10% variation. It is therefore recommended that CFD modelling be used to determine tracer test strategy before conducting a full-scale tracer test, and multiple sampling points should be employed during tracer tests, if possible. In addition, a research based on full-scale investigation has also been done to compare the three different CT prediction approaches: CT10, integrated disinfection design framework (IDDF), and CFD, to determine the most appropriate method for design and operation of ozone systems. The CFD approach yielded more accurate predictions of inactivation efficacy than the other two approaches. The current results also suggested that the differences in the three approaches in CT predictions became smaller at higher contactor T10/T ratios conditions as the contactors performed more closely to ideal plug flow reactors. This study has demonstrated that the computational fluid dynamics (CFD) approach is an efficient tool for improving ozone disinfection performance of existing water treatment plants and designing new ozonation systems. The model developed in this study can be used for ozone contactor design, evaluation, and troubleshooting. It can also be used as a virtual experimental tool to optimize ozone contactor behaviour under varying water quality and operational conditions.
207

Removal of Enteric Viruses By Ultrafiltration Membranes

El-Hadidy, Ahmed 24 August 2011 (has links)
Application of low pressure membranes in drinking water treatment, including both microfiltration (MF) and ultrafiltration (UF), have witnessed a rapid increase in the past decades. Low pressure membranes are considered a good technology in retrofitting existing conventional drinking water treatment plants or in newly constructed plants to meet the stringent regulations for drinking water treatment that aim at preventing health risks of waterborne diseases. Enteric viruses are one of the major types of waterborne pathogens, and they can be commonly found and are persistent in the environment. Both the United States and Canada require a 99.99% (4-log) removal of viruses during the drinking water treatment train. Unlike MF membranes, UF membranes have a very good potential for removing enteric viruses from the water due to their smaller pores comparable to the size of viruses. Drinking water regulations/guidelines in both the United States and Canada do not grant UF membranes any removal credit for viruses by default; however they have the provision that, in certain cases, virus removal credit may be granted based on pilot scale challenge testing. A better understanding of the interaction between the UF membranes and virus rejection can help to establish a removal credit for UF membranes. An essential part of this will be the effect of the membrane operation on the rejection of viruses to determine if UF membranes can offer a consistent removal of viruses. Membrane fouling is one of the major problems in membrane operation and it can affect the rejection characteristics of the membrane and improve its performance. The aim of this study was to investigate the removal of virus surrogates (MS2 and φX174 bacteriophage) using a commercial UF membrane under different conditions, to obtain information about the removal mechanisms of viruses. The experimental filtration unit was designed to have similar conditions like the full scale membrane treatment plants. The UF membrane used in this study provided very good removal of both MS2 and φX174 bacteriophage. The obtained results were consistent and in agreement with the expected removals based on the membrane characterization results and types of virus surrogate. As part of this work, a detailed study to improve methods for characterizing the pore size distribution of membranes was conducted. In the second part of the study, two different types of surface waters were used to study the effect of membrane fouling on virus removal. It was found that mainly hydraulically irreversible fouling could significantly improve the virus removal by UF membranes. Different cleaning regimes that are used in treatment plants had varying effects on virus removal. After maintenance cleaning, virus removal remained higher than that of clean membranes, and only chemical cleaning was effective for completely removing membrane foulants and returning virus removal back to base levels. Advanced analytical techniques were used to define the nature of the fouling layer on the membrane surface and how the foulants affected the rejection of viruses. Finally, our study showed that UF membranes are a robust treatment technology for removing different types of enteric virus surrogates from water under different operational conditions. Close monitoring of the UF unit performance and direct integrity testing can possibly detect membrane problems that can affect the rejection of viruses. Based on the virus physical characteristics and a detailed study of the membrane surface characteristics, especially the pore size distribution of the membrane, the removal of the specific virus can be closely estimated.
208

An Investigation of Nitrification Predictors and Factors in Two Full-Scale Drinking Water Distribution Systems

Scott, Daniel January 2012 (has links)
The biologically-mediated process of nitrification can occur in chloraminated drinking water distribution systems. In this process, ammonia is oxidized to nitrite by ammonia-oxidizing bacteria (AOB) and archaea (AOA). In complete nitrification, nitrite is further converted to nitrate by nitrite-oxidizers; however, bacterial mediation of this step is less critical as a chemical-oxidation pathway also exists. The initial conversion of ammonia to nitrite is also more critical due to its role in the degradation of the disinfectant residual. Nitrification is affected by factors such as the concentrations of ammonia and total chlorine, the pH of the drinking water, and the temperature. The key consequence of distribution system nitrification is an accelerated decay of the disinfectant residual; it can also lead to increases in nitrite and nitrate, and a potential proliferation of heterotrophic bacteria. The goal of this thesis is to enhance understanding of distribution system nitrification; one aspect to this goal is the evaluation of models for nitrification. The approach followed in this study was to collect water samples from two full-scale distribution systems in Southern Ontario. In the first phase, a sampling campaign was conducted at sites in these systems, with water samples being analyzed for parameters considered relevant to nitrification, such as the concentrations of nitrogen species affected by nitrification, the disinfectant residual, and the levels of ammonia-oxidizing microorganisms. In the second phase, batch tests were conducted with water from these same distribution systems. In the course of the field sampling campaign some indications of nitrification were detected, but there were no severe nitrification episodes as indicated by major losses of the disinfectant or prolonged elevations in nitrite levels. On some occasions at some sites there were small rises in nitrite above baseline levels; moderate declines in total chlorine residual were also seen. Nitrifying microorganisms were present in most samples, as detected by both culture-based and molecular methods (PCR). The latter was able to distinguish AOA from AOB; both were detected in the systems included in this study, with AOB gene counts outnumbering those of AOA at most sites. Using Spearman non-parametric correlations, significant correlations were found between some parameters relevant to nitrification. Notably, AOB were found to be positively correlated with heterotrophic plate counts (HPC), reinforcing the latter's role as a useful indicator of microbial regrowth conditions in a distribution system. Also of interest is the negative correlation between total chlorine residual and levels of microorganisms, reminding drinking water professionals of the value of maintaining a stable disinfectant residual. Batch testing investigations compared total chlorine decay curves between inhibited and uninhibited samples to provide insight into the microbial contribution to disinfectant decay. Four types of decay curves were identified, with qualitative differences in the microbial contribution to the disinfectant residual decay. Liquid chromatography with organic carbon detection (LC-OCD) was applied to investigate changes in the character of the dissolved organic carbon over the course of the batch tests. Based on the results of this study, it is recommended to evaluate the results of nitrification batch tests based on a visual identification of the curve type and calculation of the decay rates and critical threshold residual (CTR), rather than relying on the microbial decay factor alone to express the results. An application of this work was in making comparisons to some models for nitrification proposed in the literature. The ultimate goal of these models is to provide drinking water system operators with a prediction of when nitrification episodes will occur so that action may be taken to avert them. The models considered in this study differ in their degree of complexity and in whether they are based on mechanistic considerations. The differences in the underlying principles and data required for analysis make these models suitable for different applications. The results of this evaluation support the use of the model of Fleming et al. (2005) in full-scale distribution systems and the use of the model by Yang et al. (2008) for research applications, while the other models considered can still offer some useful insights. The results of this research can be applied to monitoring and operational practices in chloraminated distribution systems where nitrification is a potential concern. The correlations between parameters that have significance to distribution system nitrification that were found in this study, along with the modelling and batch testing evaluated in this work, can provide insight into predicting conditions favourable to nitrification and avoiding or averting nitrification episodes.
209

The capacity of Montreal Lake, SK to provide safe drinking water

Lebel, Pierre Mathieu 30 April 2008 (has links)
Recent waterborne disease outbreaks in Canada have brought national awareness to drinking water safety. In particular, the long history of poor water quality plaguing First Nations communities has received substantial public attention. Despite several initiatives from the federal government and considerable financial support, the quality of drinking water on reserves has shown little improvement and continues to pose health risks. As a result, there is a growing interest in the ability of First Nations communities to effectively manage their drinking water resources. The purpose of this study was to assess the capacity of Montreal Lake, SK to provide its residents with safe drinking water, both now and into the future. This research employed a mixed methods approach in the examination of the communitys water system and management practices. Data sources included individual interviews, a public workshop, documents and inspection reports, and water quality data. Water system capacity was considered in terms of financial, human resources, institutional, social/political, and technical dimensions. An analytical framework was developed through a literature review where each dimension of capacity was rated based on a series of indicators. It was determined that there are no serious deficiencies in the management of Montreal Lakes drinking water. However, a number of flaws in each aspect drinking water management were detected. These include weak linkages between the agencies responsible for drinking water provision, and a low level of drinking water safety for community residents served by the truck haul distribution system. This research confirms the multi-dimensional aspects of water system capacity, reveals the necessity for the different levels of authority to work together, and provides an analytical framework which may be applicable to future studies examining First Nations and small-scale drinking water systems.
210

Reduction of Perchlorate and Nitrate by Aluminum Activated by pH Change and Electrochemically Induced Pitting Corrosion.

Raut Desai, Aditya B. 2010 May 1900 (has links)
Highly oxidized species like perchlorate and nitrate that are released into the environment by anthropogenic activities are a source of concern as they have been known to contaminate groundwater. These species are extremely soluble in water and can migrate through aquifer systems, travelling substantial distances from the original site of contamination. Due to their high solubility, these oxy-anions cannot be treated using conventional treatment processes like filtration and sedimentation. Several treatment technologies are currently available to abate the human health risk due to exposure to perchlorate and nitrate. However, most of the existing treatment processes are expensive or have limitations, like generation of brines with high concentrations of perchlorate or nitrate. Aluminum can effectively reduce perchlorate and nitrate, if the protective oxide film that separates the thermodynamically reactive Al0 from most environments is removed. Aluminum was activated by pH change and electrochemically induced, pitting corrosion to remove the passivating oxide layer and expose the underlying, thermodynamically reactive, zero-valent aluminum. A partially oxidized species of aluminum, like monovalent aluminum, is believed to bring about the reduction of perchlorate and nitrate. This research studied the reduction of perchlorate and nitrate by aluminum that was activated by these two mechanisms. Results indicated that aluminum activated by pH change resulted in an instantaneous decrease in perchlorate concentration without any increase in chlorate or chloride concentrations, which suggests that the perchlorate might be adsorbed on the aluminum oxide surface. However, aluminum activated by electrochemically induced pitting corrosion can effectively reduce perchlorate to chlorate. Nitrate, on the other hand, was reduced completely to ammonia by both treatment mechanisms. The studies conducted in this dissertation suggest that aluminum can be effectively used as a reducing agent to develop a treatment process to reduce perchlorate and nitrate.

Page generated in 0.0625 seconds