Heat Transfer and Flow Measurements on a One-Scale Gas Turbine Can Combustor Model

Abraham, Santosh 05 November 2008 (has links)
Combustion designers have considered back-side impingement cooling as the solution for modern DLE combustors. The idea is to provide more cooling to the deserved local hot spots and reserve unnecessary coolant air from local cold spots. Therefore, if accurate heat load distribution on the liners can be obtained, then an intelligent cooling system can be designed to focus more on the localized hot spots. The goal of this study is to determine the heat transfer and pressure distribution inside a typical can-annular gas turbine combustor. This is one of the first efforts in the public domain to investigate the convective heat load to combustor liner due to swirling flow generated by swirler nozzles. An experimental combustor test model was designed and fitted with a swirler nozzle provided by Solar Turbines Inc. Heat transfer and pressure distribution measurements were carried out along the combustor wall to determine the thermo-fluid dynamic effects inside a combustor. The temperature and heat transfer profile along the length of the combustor liner were determined and a heat transfer peak region was established. Constant-heat-flux boundary condition was established using two identical surface heaters, and the Infrared Thermal Imaging system was used to capture the real-time steady-state temperature distribution at the combustor liner wall. Analysis on the flow characteristics was also performed to compare the pressure distributions with the heat transfer results. The experiment was conducted at two different Reynolds numbers (Re 50,000 and Re 80,000), to investigate the effect of Reynolds Number on the heat transfer peak locations and pressure distributions. The results reveal that the heat transfer peak regions at both the Reynolds numbers occur at approximately the same location. The results from this study on a broader scale will help in understanding and predicting swirling flow effects on the local convective heat load to the combustor liner, thereby enabling the combustion engineer to design more effective cooling systems to improve combustor durability and performance. / Master of Science
2

Heat Transfer and Flow Measurements in Gas Turbine Engine Can and Annular Combustors

Carmack, Andrew Cardin 31 May 2012 (has links)
A comparison study between axial and radial swirler performance in a gas turbine can combustor was conducted by investigating the correlation between combustor flow field geometry and convective heat transfer at cold flow conditions for Reynolds numbers of 50,000 and 80,000. Flow velocities were measured using Particle Image Velocimetry (PIV) along the center axial plane and radial cross sections of the flow. It was observed that both swirlers produced a strong rotating flow with a reverse flow core. The axial swirler induced larger recirculation zones at both the backside wall and the central area as the flow exits the swirler, and created a much more uniform rotational velocity distribution. The radial swirler however, produced greater rotational velocity as well as a thicker and higher velocity reverse flow core. Wall heat transfer and temperature measurements were also taken. Peak heat transfer regions directly correspond to the location of the flow as it exits each swirler and impinges on the combustor liner wall. Convective heat transfer was also measured along the liner wall of a gas turbine annular combustor fitted with radial swirlers for Reynolds numbers 210000, 420000, and 840000. The impingement location of the flow exiting from the radial swirler resulted in peak heat transfer regions along the concave wall of the annular combustor. The convex side showed peak heat transfer regions above and below the impingement area. This behavior is due to the recirculation zones caused by the interaction between the swirlers inside the annulus. / Master of Science