Spelling suggestions: "subject:"cynamic impacts"" "subject:"clynamic impacts""
1 |
Contact damage of ceramics and ceramic nanocompositesWade, James January 2017 (has links)
Herein, we study the contact damage performance of two armour ceramics, alumina and silicon carbide, with varying microstructures and one particle-reinforced ceramic nanocomposite, alumina/silicon carbide, in an attempt to understand the microstructural mechanisms that affect plasticity and cracking under quasi-static and dynamic conditions. Quasi-static contact damage was imitated using Vickers indentation over a varying load regime. Numerical analysis of the indentation size effect, performed using the proportional specimen resistance model, allowed the contributions of plastic deformation and cracking to be separated into two individual values. In all three samples, higher levels of surface energy were found to correlate with increased amounts of cracking per unit area of indentation impression. Analytical modelling of crack initiation during Vickers indentation together with quantitative measurements of surface flaw populations revealed that such an increase in cracking damage was the result of higher densities of larger flaws. The hardness of the monolithic ceramics was found vary based on grain size and porosity levels, a smaller average grain size and lower porosity levels resulting in higher hardness values. In the nanocomposite materials, hardening was found to occur with further additions of silicon carbide nanoparticles. Such an effect has been attributed to the increased dislocation densities, as measured using Cr3+/Al2O3 fluorescence spectroscopy, and the impedance of dislocation movement within the lattice due to the presence of silicon carbide nanoparticles. In order to simulate dynamic contact damage, a low velocity, scaled-down drop-weight test was designed and developed. The dynamic contact damage resistance was determined based on the depth of penetration of a blunt indenter. In the monolithic ceramics, the indenter penetration was found to be shallower in materials of higher hardness. However, the nanocomposite materials displayed an opposing trend, the indenter penetration becoming deeper in the samples of higher hardness. The macro-scale fracture patterns produced during drop-weight impacts were seen to vary based on flaw populations and indenter penetration. In certain microstructures, extensive micro-cracking was also observed.
|
2 |
Implementation of Machine Learning and Internal Temperature Sensors in Nail Penetration Testing of Lithium-ion BatteriesCasey M Jones (9607445) 13 June 2023 (has links)
<p>This work focuses on the collection and analysis of Lithium-ion battery operational and temperature data during nail penetration testing through two different experimental approaches. Raman spectroscopy, machine learning, and internal temperature sensors are used to collect and analyze data to further investigate the effects on cell operation during and after nail penetrations, and the feasibility of using this data to predict future performance.</p>
<p><br></p>
<p>The first section of this work analyzes the effects on continued operation of a small Lithium-ion prismatic cell after nail penetration. Raman spectroscopy is used to examine the effects on the anode and cathode materials of cells that are cycled for different amounts of time after a nail puncture. Incremental capacity analysis is then used to corroborate the findings from the Raman analysis. The study finds that the operational capacity and lifetime of cells is greatly reduced due to the accelerated degradation caused by loss of material, uneven current distribution, and exposure to atmosphere. This leads into the study of using the magnitude and corresponding voltage of incremental capacity peaks after nail puncture to forecast the operation of damaged cells. A Gaussian process regression is used to predict discharge capacity of different cells that experience the same type of nail puncture. The results from this study show that the method is capable of making accurate predictions of cell discharge capacity even with the higher rate of variance in operation after nail puncture, showing the method of prediction has the potential to be implemented in devices such as battery management systems.</p>
<p><br></p>
<p>The second section of this work proposes a method of inserting temperature sensors into commercially-available cylindrical cells to directly obtain internal temperature readings. Characterization tests are used to determine the effect on the operability of the modified cells after the sensors are inserted, and lifetime cycle testing is implemented to determine the long-term effects on cell performance. The results show the sensor insertion causes a small reduction in operational performance, and lifetime cycle testing shows the cells can operate near their optimal output for approximately 100-150 cycles. Modified cells are then used to monitor internal temperatures during nail penetration tests and how the amount of aging affects the temperature response. The results show that more aging in a cell causes higher temperatures during nail puncture, as well as a larger difference between internal and external temperatures, due mostly to the larger contribution of Joule heating caused by increased internal resistance.</p>
|
Page generated in 0.05 seconds