• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 548
  • 94
  • 93
  • 91
  • 30
  • 22
  • 17
  • 15
  • 14
  • 12
  • 12
  • 9
  • 9
  • 8
  • 5
  • Tagged with
  • 1125
  • 419
  • 167
  • 149
  • 114
  • 108
  • 105
  • 94
  • 86
  • 85
  • 83
  • 71
  • 70
  • 64
  • 63
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
531

Stewart Platform Actuator for Direct Access Cochlear Implant

Patil, Gaurav 08 September 2015 (has links)
No description available.
532

Image Analysis for Computer-aided Histopathology

Sertel, Olcay 14 September 2010 (has links)
No description available.
533

Biking on Campus: The Impacts of Administrative Structure, Policies, Programs, and Facilities on Mode Share

Walton, Sara A. 29 July 2011 (has links)
No description available.
534

Robust Variability Analysis Using Diffusion Tensor Imaging

Irfanoglu, Mustafa O. 27 July 2011 (has links)
No description available.
535

Quantification and Detection of Motion Artifacts in Laser Speckle Contrast Imaging / Kvantifiering och detektering av rörelseartefakter inom laser-speckle-kontrast-avbildning

Amphan, Dennis January 2022 (has links)
Laser speckle contrast imaging (LSCI) is a non-invasive method for assessment of microcirculatory blood flow. The technique is based on analysis of speckle patterns to build 2D maps of perfusion with high spatial and temporal resolution. A drawback of the method is that it is highly sensitive to motion artifacts since the perfusion estimates are based on quantification of the motion blurring in the images. The camera is today limited to a bulky stand for good measurements, but even as it is fixed, it does not ensure that the patient is completely still. In many clinical settings, it would be advantageous to have a more flexible camera and to be able to detect if an image is influenced by external motion. Multi-exposure laser speckle contrast imaging (MELSCI) is an extension to LSCI that utilizes the contrast from multiple exposure times. The gain in information has paved way for more accurate perfusion estimates. The technique has been limited due to its computational complexity, but recently a real time system has been developed. The goals of this thesis was twofold, firstly find a quantifiable measure of motion artifacts to be able to evaluate and compare LSCI and MELSCI. Secondly, propose an algorithm that detects movements in LSCI recordings. Motion artifacts in LSCI and MELSCI were investigated by developing a setup where repeatable movements could be made. Measurements of a hand influenced by motions of different speeds and directions were acquired and the relative difference between motion and static states were calculated and compared for the two systems. The relative difference of the MELSCI measurements were lower for all speeds above 0.57 mm/s, indicating more robustness to motion artifacts. A detection algorithm using image registration to calculate the instantaneous speed in each frame of the recording was developed. The method successfully detects movements perpendicular to the camera and shows that the intensity images of an LSCI recording can be used to give a direct indication of when movement has occurred.
536

Finite Element Head ModelPersonalization by Mesh Morphing / Personalisering av finita element huvudmodeller genom bildregistering

Levin, Yann January 2021 (has links)
Finite Element (FE) head models are very convenient tools forthe study of Traumatic Brain Injuries (TBIs) but lack significantanatomical details for the investigation of morphology or age-dependantinjury mechanisms. In this context, the use of deformable registrationalgorithms for the generation of personalized head models is veryconsistent for the development of improved protection systems likehelmets. This thesis presents the performances of the registrationpipeline Demons combined to the Difformable Registration via AttributesMatching and Mutual-SaliencyWeighting (DRAMMS) for the generationof FE head models. Twelve subject-specific models are formed bymorphing the baseline mesh with the displacement fields resultingfrom the registration methods. The obtained models are assessedand compared through the evaluation of elements’ quality by analysisof the distortion index distribution. The Dice similarity coefficientis also calculated to estimate the personalization accuracy of theapplied pipeline. The Demons+DRAMMS registration pipeline showssatisfactory personalization accuracy for cranial mask and internalbrain structures. No significant degradation of mesh quality dueto the morphing process or specific subject morphology is observed.The present work corroborates previous study regarding the use ofDemons+DRAMMS registration pipeline for generating subject-specifichead models and validates the performances of the registration methodsand the repeatability of the morphing process for this purpose.
537

DOSE-BASED EVALUATION OF A PROSTATE BED PROTOCOL

Dona, Lemus M. Olga 10 1900 (has links)
<p>The image-guided radiation therapy (IGRT) protocol used at Juravinski Cancer Center for post-prostatectomy patients involves acquiring a kV cone beam computed tomography (CBCT) image at each fraction and shifting the treatment couch to align surgical clips. This IGRT strategy is promising but its dosimetric impact is unknown, it requires significant resources, and delivers non-negligible doses to normal tissues. The objective of this work is to evaluate this IGRT protocol and investigate possible alternatives.</p> <p>IGRT delivered dose is reconstructed by deforming the planning CT to the CBCT images acquired at each fraction, computing dose on the deformed images, and inversely transforming the dose back to the original geometry. The treatments of six patients were evaluated under four scenarios: no guidance (Non-IGRT), daily guidance as performed clinically (IGRT), guidance on alternating days (Alt-IGRT), and daily automated guidance (Auto-IGRT). For one patient, the impact of reducing the planning target volume (PTV) margin to five (IGRT-5) and eight (IGRT-8) mm isotropic was also evaluated.</p> <p>With the standard clinical PTV margin of ten/seven mm, the evaluated alternatives produced similar results. The minimum dose to the CTV was decreased by 1.6±1.0, 1.2±0.7, and 0.8±0.8 Gy for Non-IGRT, Alt-IGRT, and IGRT, respectively. IGRT with manual shifting did not appear to significantly improve the delivered treatment dose compared to Auto-IGRT (difference in CTV minimum dose was 1.2±2.1Gy). Doses to the organs at risk varied but in general, an increased volume of the bladder and rectum received low doses while smaller portions received high doses. The IGRT-5 and -8 analyses showed the same CTV dose can be delivered with significant reduction in normal tissue exposure. Overall, the desired doses are delivered during IGRT although much of this may be attributed to the large PTV margins currently employed clinically.</p> / Master of Science (MSc)
538

VIRTUAL FLUOROSCOPY SYSTEM FOR ARTHROSCOPIC SURGICAL TRAINING

Hosseini, Zahra 10 1900 (has links)
<p>Minimally invasive operations have gained popularity over open surgical procedures in the recent years. These procedures, require the surgeon to perform highly specialized tasks including manipulation of tools through small incisions on the surface of the skin while looking at the images that are displayed on a screen. Therefore, effective training is required for the surgeons prior to performing such procedures on patients.</p> <p>In this thesis I explored a novel idea for creating a training system for arthroscopic surgery. Previously obtained CT images of a patient model and the surgical tools are manipulated to create a library of fluoroscopy images. The surgical tools are tracked (a mechanical tracker and an electromagnetic tracker used in each iterations) in order to generate a spacial relationship between the patient model and the surgical tools. The position and orientation information from the tracking system is translated into the image coordinate frame. These homologous points in the two images (of surgical tools and the patient model), are used to co-register and overlay the two images and create a virtual fluoroscopy image.</p> <p>The output image and the system performance was found to be very good and quite similar to that of a fluoroscopy system. The registration accuracy was evaluated using Root Mean Square Target Registration Error (RMS TRE). The RMS TRE for the system setup with the mechanical tracker was evaluated at 2:0 mm, 2:1 mm, and 2:5 mm, for 4, 5, and 6 control points, respectively. In the system setup with the electromagnetic tracking system the RMS TRE was evaluated at 7:6 mm, 12:4 mm, and 11:3 mm, for 5, 7, and 9 control points, respectively. The acceptable range of error for arthroscopy procedures has been proposed to be 1-2 mm.</p> <p>It was concluded that by using a tracking system, which is not prone to interference and allows for a wide range of motion this system can be completed to the point of manufacturing and use in training new surgeons.</p> / Master of Applied Science (MASc)
539

Labeling Adult Sex Offenders and Sexually Violent Predators: The Impact of Registration and Community Notification

Gaines, Jonathan S. January 2009 (has links)
When released from prison, sex offenders are typically required to register with designated law enforcement officials as a condition of their parole. These officials can warn local community members, organizations, and establishments of the offender's incoming presence. Research indicates that community notification can adversely affect sex offenders in terms of their interpersonal and family relationships, employment opportunities and housing, and can lead to offender harassment that extends to the family members of sex offenders (Burchfield & Mingus, 2008; Levenson & Cotter, 2005a, 2005b; Levenson, D'Amora, & Hern, 2007; Tewksbury, 2004, 2005; Tewksbury & Lees, 2007; Zevitz & Farkas, 2000b). The current analysis seeks to build on and extend the existing literature by investigating the consequences of sex offender registration and community notification from the perspective of registered sex offenders and sexually violent predators in Pennsylvania. Using multiple methods of data collection (i.e., survey and interview research) and analyses, the present study contributes to the current understanding of how sex offenders experience registration and community notification and focuses on the positive and negative effects (e.g., unintended and unanticipated consequences) of being labeled and subject to community notification. Data for the present study were collected in collaboration with four providers of sex offender treatment. These treatment facilities are non-profit mental health organizations that provide both outpatient examinations and treatment services for sex offenders. All treatment providers are located in Pennsylvania, and will remain anonymous in the current study. The survey sample consists of 200 adult male sex offenders. For the purposes of making comparisons, 181 of the sampled sex offenders were further classified as the following three subsamples: (1) registered sex offenders (RSOs) (n = 121), (2) sexually violent predators (SVPs) (n = 13), and (3) non-registered sex offenders (and non-sexually violent predators) (n = 47). Nine of the SVPs elected to participate in the face-to-face interview portion of this research where topics focused on the impact of active community notification, the process whereby the state police are required to mail out letters to community members about an offender's physical description and home address. The age of the interview sample ranged from 35 to 63, and the average was 49.22 years old. Descriptive results of the complete survey sample reveal that most sex offenders are White or African American, middle-aged, and not married, and have relatively little formal education. Most sex offenders are working in some capacity, self-identify as "working class," and earn less than $20,000 per year. The majority of the total sample of sex offenders has been convicted of indecent assault/indecent sexual assault (24.6%) followed by possession of child pornography (12%) and then rape (11.4%). Overall, most victims are minor-aged females who were known by - but not related to - the offender. Findings from the anonymous survey also indicate that over 40 percent of the sampled RSOs are restricted by a 1,000-foot-rule, have primary group members who sustained some type of harm, and have had meaningful, personal relationships severed. Sexually violent predators experienced job loss, denial of employment, loss of housing, and denial of a place to live, and were treated rudely in public, and had primary group members who experienced emotional harm and, separately, had personal relationships severed at a higher rate (i.e., at least 10 percentage points) than RSOs. None of the SVPs were physically assaulted, whereas six RSOs (i.e., 5 percent of 120 RSOs) were physically assaulted. Using only a combination of two of the three subsamples of sex offenders (i.e., RSOs and SVPs), the multivariate contingency table analyses assessed how sex offenders' selection of victim-type, relationship to victim, and race influenced the fifteen different economic, residency-related, and harassment outcomes. Specifically, if offenders victimized a child (i.e., victims from age 5 to 17), as opposed to an adult (i.e., 18 or older), they were significantly more likely to be restricted by a 1,000-foot-rule, as expected. Offenders who victimized children were also more likely than offenders who victimized adults (by at least 10 percentage points) to experience job loss and receive harassing telephone calls, and to have primary group members who sustained some form of emotional harm and, separately, have personal relationships severed. Findings gleaned from the interviews indicate that SVPs are experiencing several of the problems identified in the previous and related literature. Specifically, six of the interviewees (66.67 percent) indicated that, since the notification process began, they have had a difficult time locating and obtaining affordable housing. Analysis of covariance (ANCOVA) was used to examine the effect of sex offenders' socio-demographics, offender characteristics, victim characteristics, and negative experiences resulting from registration and/or notification on self-esteem (Rosenberg, 1965), mastery (Pearlin et al., 1981; Pearlin & Schooler, 1978), stigma (Link, 1987; Link et al., 1997), and depression using the Center for Epidemiologic Studies Depression Scale (CES-D). The multivariate regression results were quite unexpected. After controlling for sex offenders' sociodemographics, offender characteristics, and victim characteristics, none of the scales devised to measure the impact of registration and/or community notification significantly predicted any of the four outcomes. The significance of these findings for criminological theory, and offender rehabilitation and reintegration are discussed. / Criminal Justice
540

Hypoxic Target Volume Determination in PET/CT Imaging : The Impact of Deformable Image Registration / Hypoxisk målvolymbestämning i PET/CT-avbildning : Påverkan av deformerbar bildregistrering

Rosenberg, Viktor January 2022 (has links)
Using a tailored dose distribution for personalized radiotherapy with the help of positron emission tomography (PET) might give an edge for successful tumour elimination. One of the main determinants for tumour radioresistance in several solid tumours has been investigated as hypoxia, including head and neck cancer (HNC). Using novel methods of converting radiotracer uptake into partial oxygen pressure distribution in the form of partial pressure maps, it is possible to delineate the hypoxic region of a target to further escalate the treatment dose there, aiming at an increase in tumour control. However, the registration between functional and structural images may have an impact on the effectiveness of dose escalation, and choosing the correct registration method could be imperative. In this master’s thesis, the impact of choosing rigid or deformable image registration between planning-CT and PET/CT images on the characterization of the hypoxic compartment, as well as on the treatment evaluation in terms of tumour control and normal tissue complication, was assessed. This was achieved by, using hypoxic patients of a cohort of 22 HNC patients, creating a separate plan for each registration method, for each patient, and comparing them quantitatively. The results showed that both methods would yield distinctly different dose distributions when planned using the same objectives and constraints in terms of dose level and shape. Furthermore, they both give a distribution of similar quality. However, using rigid registration together with the deformed PET did not render lower results overall in tumour control. Thus, no advantage could be seen in choosing deformable registration over rigid registration when aiming at tumour control.

Page generated in 0.1269 seconds