Dosimetria de altas doses de raios gama e elétrons com diodos de Si resistentes a danos de radiação / Gamma and electron high dose dosimetry with rad-hard Si diodes

Pascoalino, Kelly Cristina da Silva 28 May 2014 (has links)
Neste trabalho foram avaliadas as principais características dosimétricas de diodos crescidos pelos métodos de Fusão Zonal (FZ) e Czochralski magnético (MCz), resistentes a danos de radiação, quando aplicados em dosimetria de processos de irradiação industrial com elétrons (1,5 MeV) e raios gama (60Co). O sistema dosimétrico proposto baseia-se no registro de valores de correntes elétricas geradas nos diodos devido à passagem da radiação ionizante. A uniformidade de resposta de um lote de dispositivos foi analisada para os diodos FZ do tipo n irradiados com raios gama. Para uma dose de até 5 kGy obteve-se um coeficiente de variação de 1,25% dos valores de corrente elétrica registrados. A queda da sensibilidade dos diodos com o acúmulo de dose (Total Ionizing Dose TID) foi observada, de acordo com o esperado, para ambos os diodos FZ e MCz, sendo mais acentuada para dispositivos do tipo n ou com resistividade menor, quando irradiados com raios gama. Nos procedimentos de irradiação com elétrons foram utilizados dois protótipos de sonda dosimétrica, sendo que um deles foi projetado para evitar a deterioração dos contatos elétricos e da metalização dos diodos, fenômeno observado durante o desenvolvimento do projeto. A queda da sensibilidade dos diodos FZ e MCz pré-irradiados foi de aproximadamente 10% e 40%, respectivamente, durante os procedimentos de irradiação com elétrons para uma dose acumulada total de 1,25 MGy. A influência dos danos causados por esse tipo de radiação nas propriedades elétricas dos diodos FZ e MCz foi avaliada por meio das medições de corrente de fuga e da capacitância em função da tensão de polarização. A corrente de fuga, que aumenta com a dose de radiação acumulada, não contribui significativamente para a formação do sinal de corrente durante a irradiação, uma vez que os diodos são operados no modo fotovoltaico, ou seja, sem tensão de polarização. Para o diodo MCz não foram observadas alterações significativas dos valores de tensão de depleção total, evidenciando sua maior tolerância aos danos induzidos pela radiação, como esperado. Como durante os procedimentos de irradiação com elétrons há uma variação acentuada dos valores de temperatura, a influência deste parâmetro para as medições de corrente elétrica foi avaliada por meio da extrapolação dos valores de corrente de fuga até 35°C. A contribuição da corrente de fuga para a corrente induzida pela radiação, devido ao aumento da temperatura, não ultrapassa 0,1% para os diodos FZ e MCz. A influência do tipo de radiação, elétrons ou raios gama, na pré-dose dos diodos foi avaliada para o dispositivo FZ do tipo n e observou-se que a pré-irradiação com elétrons é mais eficiente no tocante à queda da sensibilidade dos dispositivos. Os resultados apresentados neste trabalho indicam a potencialidade da aplicação dos diodos FZ e MCz como dosímetros em processos de irradiação de rotina com raios gama e elétrons. Vale ressaltar que a vantagem do sistema proposto reside na possibilidade de acompanhamento em tempo real dos processos envolvidos, sobretudo para elétrons, permitindo a monitoração dos parâmetros dos aceleradores, tais como velocidade de esteira e corrente elétrica de feixe. / In this work the main dosimetric characteristics of rad-hard Float Zone (FZ) and magnetic Czochralski (MCz) diodes to electrons (1.5 MeV) and gamma (60Co) radiation are evaluated. The dosimetric system proposed is based on electrical current measurements due to radiation interactions on the devices. The batch response uniformity was studied for the n-type FZ diodes irradiated with gamma rays. The coefficient of variation of the current measurement was about 1.25% at 5 kGy of accumulated dose. A sensitivity decrease with the increase of the accumulated dose (Total Ionizing Dose TID) was observed for both FZ and MCz diodes. For gamma irradiation, these effect is more pronounced for n-type or smaller resistivity diodes. Two types of dosimetric probe were used on the electron irradiation procedures, one of them specially designed to avoid the deterioration of the electrical contacts and the diodes metallization. The sensitivity of the preirradiated FZ and MCz diodes fell about 10% and 40%, respectively, during electron irradiation at 1.25 MGy of accumulated dose. The effect of electron radiation damage on the electrical properties of the diodes was studied by the means of leakage current and capacitance measurements as a function of bias voltage. The leakage current increases with the accumulated dose but does not contributes significantly to the current signal, since the diodes are operated in photovoltaic mode, without bias voltage. For the MCz diode no change in the full depletion voltage was observed, which indicates its higher tolerance to radiation-induced damage, as expected. During electron irradiation the temperature increases and in order to determine its influence for the current signals, the leakage current values were extrapolated up to 35 °C. The contribution does not exceed 0.1% for FZ and MCz diodes. The effect of the radiation type, electrons or gamma rays, on the predose procedures was analyzed for the FZ n-type device and was observed that the electron pre-irradiation is more efficient regarding the sensitivity decrease. The present work indicates the potential application of FZ and MCz diodes as dosimeters in gamma rays and in electron routine irradiation processes. It is worth noting that the proposed system advantage relies on the possibility of real-time monitoring of electron accelerator parameters.
2

Dosimetria de altas doses de raios gama e elétrons com diodos de Si resistentes a danos de radiação / Gamma and electron high dose dosimetry with rad-hard Si diodes

Kelly Cristina da Silva Pascoalino 28 May 2014 (has links)
Neste trabalho foram avaliadas as principais características dosimétricas de diodos crescidos pelos métodos de Fusão Zonal (FZ) e Czochralski magnético (MCz), resistentes a danos de radiação, quando aplicados em dosimetria de processos de irradiação industrial com elétrons (1,5 MeV) e raios gama (60Co). O sistema dosimétrico proposto baseia-se no registro de valores de correntes elétricas geradas nos diodos devido à passagem da radiação ionizante. A uniformidade de resposta de um lote de dispositivos foi analisada para os diodos FZ do tipo n irradiados com raios gama. Para uma dose de até 5 kGy obteve-se um coeficiente de variação de 1,25% dos valores de corrente elétrica registrados. A queda da sensibilidade dos diodos com o acúmulo de dose (Total Ionizing Dose TID) foi observada, de acordo com o esperado, para ambos os diodos FZ e MCz, sendo mais acentuada para dispositivos do tipo n ou com resistividade menor, quando irradiados com raios gama. Nos procedimentos de irradiação com elétrons foram utilizados dois protótipos de sonda dosimétrica, sendo que um deles foi projetado para evitar a deterioração dos contatos elétricos e da metalização dos diodos, fenômeno observado durante o desenvolvimento do projeto. A queda da sensibilidade dos diodos FZ e MCz pré-irradiados foi de aproximadamente 10% e 40%, respectivamente, durante os procedimentos de irradiação com elétrons para uma dose acumulada total de 1,25 MGy. A influência dos danos causados por esse tipo de radiação nas propriedades elétricas dos diodos FZ e MCz foi avaliada por meio das medições de corrente de fuga e da capacitância em função da tensão de polarização. A corrente de fuga, que aumenta com a dose de radiação acumulada, não contribui significativamente para a formação do sinal de corrente durante a irradiação, uma vez que os diodos são operados no modo fotovoltaico, ou seja, sem tensão de polarização. Para o diodo MCz não foram observadas alterações significativas dos valores de tensão de depleção total, evidenciando sua maior tolerância aos danos induzidos pela radiação, como esperado. Como durante os procedimentos de irradiação com elétrons há uma variação acentuada dos valores de temperatura, a influência deste parâmetro para as medições de corrente elétrica foi avaliada por meio da extrapolação dos valores de corrente de fuga até 35°C. A contribuição da corrente de fuga para a corrente induzida pela radiação, devido ao aumento da temperatura, não ultrapassa 0,1% para os diodos FZ e MCz. A influência do tipo de radiação, elétrons ou raios gama, na pré-dose dos diodos foi avaliada para o dispositivo FZ do tipo n e observou-se que a pré-irradiação com elétrons é mais eficiente no tocante à queda da sensibilidade dos dispositivos. Os resultados apresentados neste trabalho indicam a potencialidade da aplicação dos diodos FZ e MCz como dosímetros em processos de irradiação de rotina com raios gama e elétrons. Vale ressaltar que a vantagem do sistema proposto reside na possibilidade de acompanhamento em tempo real dos processos envolvidos, sobretudo para elétrons, permitindo a monitoração dos parâmetros dos aceleradores, tais como velocidade de esteira e corrente elétrica de feixe. / In this work the main dosimetric characteristics of rad-hard Float Zone (FZ) and magnetic Czochralski (MCz) diodes to electrons (1.5 MeV) and gamma (60Co) radiation are evaluated. The dosimetric system proposed is based on electrical current measurements due to radiation interactions on the devices. The batch response uniformity was studied for the n-type FZ diodes irradiated with gamma rays. The coefficient of variation of the current measurement was about 1.25% at 5 kGy of accumulated dose. A sensitivity decrease with the increase of the accumulated dose (Total Ionizing Dose TID) was observed for both FZ and MCz diodes. For gamma irradiation, these effect is more pronounced for n-type or smaller resistivity diodes. Two types of dosimetric probe were used on the electron irradiation procedures, one of them specially designed to avoid the deterioration of the electrical contacts and the diodes metallization. The sensitivity of the preirradiated FZ and MCz diodes fell about 10% and 40%, respectively, during electron irradiation at 1.25 MGy of accumulated dose. The effect of electron radiation damage on the electrical properties of the diodes was studied by the means of leakage current and capacitance measurements as a function of bias voltage. The leakage current increases with the accumulated dose but does not contributes significantly to the current signal, since the diodes are operated in photovoltaic mode, without bias voltage. For the MCz diode no change in the full depletion voltage was observed, which indicates its higher tolerance to radiation-induced damage, as expected. During electron irradiation the temperature increases and in order to determine its influence for the current signals, the leakage current values were extrapolated up to 35 °C. The contribution does not exceed 0.1% for FZ and MCz diodes. The effect of the radiation type, electrons or gamma rays, on the predose procedures was analyzed for the FZ n-type device and was observed that the electron pre-irradiation is more efficient regarding the sensitivity decrease. The present work indicates the potential application of FZ and MCz diodes as dosimeters in gamma rays and in electron routine irradiation processes. It is worth noting that the proposed system advantage relies on the possibility of real-time monitoring of electron accelerator parameters.
3

Avaliacao dosimetrica da solucao fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimetria de eletrons e neutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

MANGUEIRA, THYAGO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:05Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
4

Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons

BULLA, ROSELI T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:54Z (GMT). No. of bitstreams: 1 06647.pdf: 14390009 bytes, checksum: 45cfd01966c46f569e307306814794db (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
5

Avaliacao dosimetrica da solucao fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimetria de eletrons e neutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

MANGUEIRA, THYAGO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:05Z (GMT). No. of bitstreams: 0 / Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
6

Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons

BULLA, ROSELI T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:54Z (GMT). No. of bitstreams: 1 06647.pdf: 14390009 bytes, checksum: 45cfd01966c46f569e307306814794db (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
7

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Mangueira, Thyago Fressatti 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.
8

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Thyago Fressatti Mangueira 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.
9

Boundary Electron Dosimetry: Radiochromic Film Measurement and Monte Carlo Simulation of Electron Absorbed Dose Near Tissue Interfaces

Khan, Fuad A. 01 1900 (has links)
Tissue heterogeneity effects present a major challenge to electron beam dosimetry in radiotherapy and radiation protection. The perturbation of the absorbed dose distribution in tissue due to the presence of heterogeneous material boundaries was investigated in this work. Experiments were conducted in a tissue-equivalent phantom in order to quantify electron backscatter from various materials. For these experiments, irradiations were performed using a 6MeV (nominal) electron beam under conditions of one dimensional geometry. Depth-energy degradation of the electron beam provided mean electron energies of 2.3MeV, 1.9MeV, and 1.4MeV at interface locations. Backscatter phenomena were investigated for the following interface geometries: polystyrene/air, polystyrene/cortical-bone-equivalent plastic, polystyrene/copper, and polystyrene/bismuth. Novel radiochromic film dosimetry techniques were developed for these experiments, and the dose and energy response characteristics of GAFChromic Type 37-041 film were investigated. Monte Carlo simulations of the experiments were performed in parallel, using tile ITS TIGER code, and methodologies were developed to determine appropriate input parameters to these simulations. From experimental and Monte Carlo results, the backscatter factor at the interface, its spatial variation with depth, and its dependence on electron energy and scatterer atomic number were investigated. / Thesis / Master of Science (MS)
10

Desenvolvimento de um programa computacional para o tratamento de sinais obtidos pela Ressonancia Paramagnetica Eletronica na dosimetria de doses altas

RODRIGUES JUNIOR, ORLANDO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:44Z (GMT). No. of bitstreams: 1 09619.pdf: 5936704 bytes, checksum: a799cb7aade21da395953ba57cba7dcc (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP