• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização hidrodispersiva de dois solos da região irrigada do Vale do São Francisco

Inácio do Carmo, André 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:16:22Z (GMT). No. of bitstreams: 2 arquivo8667_1.pdf: 2266908 bytes, checksum: 0206b11ae129ac1b2eb8e327f0ddd6a9 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A caracterização hidrodispersiva de um Latossolo e de um Neossolo Quartzarênico, ambos da região do Vale do São Francisco, foi realizada em laboratório por meio de ensaios de deslocamento de líquidos miscíveis em colunas de solo deformado. Os ensaios compreenderam o deslocamento de um pulso de 1,0 volume de poros da solução de KBr nas vazões de 0,4; 0,8; 1,2; 1,6 e 2,0 cm³.min-1 e nas concentrações de 0,1; 0,5 e 1,0M, sendo realizadas três repetições para cada ensaio, sob condições de saturação e fluxo em regime estacionário. Por meio do programa CXTFIT 2.0, que ajusta a solução analítica da equação do modelo convectivodispersivo (CDE) aos pontos da curva de experimental eluição, foi possível obter os parâmetros hidrodispersivos: fator de retardamento (R) e o coeficiente de dispersão hidrodinâmica (D). O modelo CDE realizou um bom ajuste aos pontos das curvas de eluição, com os valores dos coeficientes de determinação variando de 98% a 99% para ambos os solos. Os valores de R ficaram próximos a 1,0, para ambos os solos, indicando que o KBr não interage com os mesmos. Verificou-se que a dispersividade do Neossolo é maior que a do Latossolo devido à distribuição do tamanho dos poros ser maior no Neossolo
2

Condutividade hidráulica no processo de eluição em um solo bruno-não-cálcico / Hydraulic conductivity in the elution process in a noncalcic brown soil

Andrade, Lazaro Nonato Vasconcellos de 04 July 1994 (has links)
Avaliar o efeito da porcentagem de sódio trocável (ESP) do solo e da concentração eletrolítica da água de percolação, sobre a condutividade hidráulica e a lixiviação em um solo bruno-não-cálcico da região do Rio Salitre-BA, foi o objetivo principal do trabalho de pesquisa. O experimento foi realizado utilizando-se amostras indeformadas coletadas em anéis cilíndricos tipo Uhland e consistiu da determinação e da análise da condutividade hidráulica do solo saturado, utilizando-se diferentes soluções percolantes. As soluções apresentavam diferentes concentrações eletrolíticas. A condutividade hidráulica e a condutividade elétrica das soluções foram medidas durante o tempo de percolação. Foram determinados os teores de sódio antes e após a eluição com as soluções. Utilizando a câmara de membrana de pressão Richards, amostras foram submetidas à diferentes tensões, determinando-se os teores de água e sódio deslocado. Então, o processo de eluição foi ajustado pelo modelo matemático de Glueckauf para o estudo do deslocamento miscível das soluções e da lixiviação dos sais em uma coluna contínua. Os resultados mostraram que a variabilidade espacial e os fluxos de natureza preferenciais determinaram correlações baixas entre os parâmetros e não permitiu ajuste adequado das curvas teóricas às curvas de eluição através do modelo matemático / The purpose of this work was, to evaluate the effect of exchangeable sodium percentage (ESP) and electrolite concentration of percolating water, on the hydraulic conductivity and leaching fraction in a Noncalcic Brown Soil of the River Salitre-Ba region. The experiment was conducted in laboratory conditions at "Luiz de Queiroz" College of Agriculture of the University of São Paulo. The experiment was carried out using undsturbed soil samples collected in Uhland type steel cylinder. It consisted on the determination and analisis of hydraulic saturated conductivity using leaching solutions with differents electrolite concentrations. The hydraulic conductivity was measured during the percolation's time. In addition, was measured the eletrical conductivity of the percolate and sodium exchangeable concentration, before and after downward flow of the solution. Using Richards pressure-membrane apparatus with large range of tensions, moisture and sodium dislocated were measured. Then, the leaching process and elutions was ajusted through Glueckauf matematical model for the studies of the miscible displacement fenomenon by leaching of salts out of the soil column. The results showed that because of the spatial variability and border-flows, the hydraulic conductivity data were heterogeneous. A low correlation between hydraulic conductivity and ESP leveIs was found. Applying calcium sulfate solution showed a beneficiaI effect on the hydraulic saturated conductivity, except when irreversible processes of mineral dissolution occoured. This effect has been associated to pH or carbonate content in the percolating solution. Although the Glueckauf model explains the nature of some fenomenons that may occur in a system of soil columns under leaching process, the effect of the boundary flow has not allowed an adequate agreement between theoretical and observed leaching curves
3

Lixiviação de nitrato e amônio em colunas indeformadas de solos de uma pedossequência do estado do Paraná / Ammonium and nitrate leaching in undisturbed soil columns of a pedossequence of Paraná State (Brazil)

Neiverth, Cristhiane Anete 26 August 2013 (has links)
O uso intensivo do solo na agricultura associado ao consumo de fertilizantes nitrogenados tem causado a degradação acelerada dos recursos naturais e dos mananciais. A presente pesquisa teve como objetivo avaliar a lixiviação dos íons nitrato (NO3-) e amônio (NH4+) em colunas indeformadas de solo de uma pedossequência (cabeceira de drenagem), no município de Ponta Grossa, Paraná, analisando o comportamento dos solos em relação à susceptibilidade à contaminação da água pela lixiviação destes íons. Foram coletadas amostras de solo indeformadas de 0,5 m de comprimento, nas profundidades de 0 a 0,50 m e de 0,50 a 1,00 m. Nas amostras à granel foram efetuadas análises de macro e micronutrientes, da acidez atual e potencial, do teor de matéria orgânica e da granulometria nas camadas de 0-0,1 m, 0,1-0,2 m, 0,2-0,3 m, 0,3-0,5 m e 0,5-1,0 m de profundidade. Para determinação das porosidades (macro, micro e total) dos solos foram feitas coletas de amostras em anéis volumétricos nas mesmas profundidades das amostras à granel. Os solos descritos e amostrados foram os seguintes: Latossolo Bruno* Distrófico rubrico (não-hidromórfico), Cambissolo Húmico Distrófico gleissólico (semi-hidromórfico) e Gleissolo Melânico Tb Distrófico típico (hidromórfico). Nas colunas foram adicionadas quantidades de ureia e NPK equivalente a adubação recomendada para um ano e o volume de água adicionado foi equivalente a um ano de precipitação pluvial. Foram determinadas as concentrações de NO3- pelo método colorimétrico do salicilato e de NH4+ pelo sistema FIA (Análise de Injeção de Fluxo) nas amostras de água eluídas nos solos. Os resultados das análises foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey ao nível de 5% de probabilidade, utilizando o programa SAS. A partir dos resultados obtidos concluiu-se que: o volume de eluição para os solos da coluna de superfície foi maior para o Gleissolo e Latossolo em relação ao Cambissolo, provavelmente devido a compactação desse último. Ao contrário do solo das colunas de superfície, a subsuperfície do Cambissolo apresentou o maior volume de eluição em relação ao Latossolo; as colunas de solo de superfície apresentaram maior lixiviação de N-NH4+ e N-NO3- no Latossolo em relação ao Cambissolo e Gleissolo. Na subsuperfície, tanto a lixiviação de N-NH4+ como a lixiviação de N-NO3- não diferenciou estatisticamente no Latossolo e Cambissolo. Para o N-NH4+ houve maior retenção no Latossolo em relação ao Cambissolo e o Gleissolo na camada 0,0-0,1 m e maior retenção no Cambissolo e o Gleissolo na camada de 0,1-0,2 m; nas demais camadas não houve diferença estatística. Com relação ao N-NO3- praticamente não houve retenção nos solos estudados; a lixiviação de nitrogênio nos três solos foi maior na forma N-NH4+ em relação a forma N-NO3- / The intensive use of soil in agriculture associated with the nitrogen fertilizers consumption has caused accelerated degradation of natural resources and water sources. This study aimed to evaluate leaching of nitrate (NO3-) and ammonium (NH4+) ions in undisturbed soils columns of a pedossequence in the county of Ponta Grossa, Paraná (Brazil) (25o09\' S, 50o16\' W) and to analyse the behavior of soils in relation to water contamination susceptibility by leaching of these ions. Undisturbed soil columns were colleted in these soils, in the depths from 0 to 0.5 m and from 0.5 to 1.0 m. In the disturbed soil samples were measured both macro and micronutriens, current and potential acidity, organic matter contend and particle size at depths of 0-0.1 m, 0.1-0.2 m, 0.2-0.3 m, 0.3-0.5 m and 0.5-1.0 m. To determine the porosity (macro, micro and total) of soil, undisturbed soil samples were colleted using Uhland extractor at the same depths of the disturbed ones. Soils described and sampled were the following: Latosol (non-hydromorphic), Cambisol (semi-hydromorphic) and Gleisol (hydromorphic). Urea and NPK equivalent to fertilization for one year and water equivalent to one year of rainfall were added into the soil columns. Concentrations of NO3- and NH4+ in eluate (water) samples and in the soils were determined by salicylate colorimetric method and FIA system (Flow Injection Analysis), respectively. The results were subjected to variance analysis and means compared by Tukey test at 5% probability, using the SAS program. From this experiment it a could be concluded that: (i) the elution water volume for surface soil columns (0.0-0.5 m) was higher for Gleisol and Latosol in relation to Cambisol, probably due to compaction of Cambisol and, in contrast, for subsurface soil columns (0.5-1.0 m), the elution water volume was higher in Cambisol than Latosol; (ii) in surface soil columns, N-NH4+ and N-N0-3 lixiviations were higher in Latosol in relation to Cambisol and Gleisol and, in subsurface soil columns, both N-NH4+ and N-N0-3 lixiviations were not significantly different in Latosol and Cambisol; (iii) there was higher N-NH4+ retention in Latosol in relation to Cambisol and Gleisol only in 0.0-0.1 m soil layer and a higher N-NH4+ retention in Cambisol and Gleisol in relation to Latosol only in 0.1-0.2 m soil layer, whereas with respect to N-N03-, there was no retention in any soil layers in studied soils; (iv) nitorogen lixiviation in the three soils was higher as N-NH4+ than N-N0-3.
4

Lixiviação de nitrato e amônio em colunas indeformadas de solos de uma pedossequência do estado do Paraná / Ammonium and nitrate leaching in undisturbed soil columns of a pedossequence of Paraná State (Brazil)

Cristhiane Anete Neiverth 26 August 2013 (has links)
O uso intensivo do solo na agricultura associado ao consumo de fertilizantes nitrogenados tem causado a degradação acelerada dos recursos naturais e dos mananciais. A presente pesquisa teve como objetivo avaliar a lixiviação dos íons nitrato (NO3-) e amônio (NH4+) em colunas indeformadas de solo de uma pedossequência (cabeceira de drenagem), no município de Ponta Grossa, Paraná, analisando o comportamento dos solos em relação à susceptibilidade à contaminação da água pela lixiviação destes íons. Foram coletadas amostras de solo indeformadas de 0,5 m de comprimento, nas profundidades de 0 a 0,50 m e de 0,50 a 1,00 m. Nas amostras à granel foram efetuadas análises de macro e micronutrientes, da acidez atual e potencial, do teor de matéria orgânica e da granulometria nas camadas de 0-0,1 m, 0,1-0,2 m, 0,2-0,3 m, 0,3-0,5 m e 0,5-1,0 m de profundidade. Para determinação das porosidades (macro, micro e total) dos solos foram feitas coletas de amostras em anéis volumétricos nas mesmas profundidades das amostras à granel. Os solos descritos e amostrados foram os seguintes: Latossolo Bruno* Distrófico rubrico (não-hidromórfico), Cambissolo Húmico Distrófico gleissólico (semi-hidromórfico) e Gleissolo Melânico Tb Distrófico típico (hidromórfico). Nas colunas foram adicionadas quantidades de ureia e NPK equivalente a adubação recomendada para um ano e o volume de água adicionado foi equivalente a um ano de precipitação pluvial. Foram determinadas as concentrações de NO3- pelo método colorimétrico do salicilato e de NH4+ pelo sistema FIA (Análise de Injeção de Fluxo) nas amostras de água eluídas nos solos. Os resultados das análises foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey ao nível de 5% de probabilidade, utilizando o programa SAS. A partir dos resultados obtidos concluiu-se que: o volume de eluição para os solos da coluna de superfície foi maior para o Gleissolo e Latossolo em relação ao Cambissolo, provavelmente devido a compactação desse último. Ao contrário do solo das colunas de superfície, a subsuperfície do Cambissolo apresentou o maior volume de eluição em relação ao Latossolo; as colunas de solo de superfície apresentaram maior lixiviação de N-NH4+ e N-NO3- no Latossolo em relação ao Cambissolo e Gleissolo. Na subsuperfície, tanto a lixiviação de N-NH4+ como a lixiviação de N-NO3- não diferenciou estatisticamente no Latossolo e Cambissolo. Para o N-NH4+ houve maior retenção no Latossolo em relação ao Cambissolo e o Gleissolo na camada 0,0-0,1 m e maior retenção no Cambissolo e o Gleissolo na camada de 0,1-0,2 m; nas demais camadas não houve diferença estatística. Com relação ao N-NO3- praticamente não houve retenção nos solos estudados; a lixiviação de nitrogênio nos três solos foi maior na forma N-NH4+ em relação a forma N-NO3- / The intensive use of soil in agriculture associated with the nitrogen fertilizers consumption has caused accelerated degradation of natural resources and water sources. This study aimed to evaluate leaching of nitrate (NO3-) and ammonium (NH4+) ions in undisturbed soils columns of a pedossequence in the county of Ponta Grossa, Paraná (Brazil) (25o09\' S, 50o16\' W) and to analyse the behavior of soils in relation to water contamination susceptibility by leaching of these ions. Undisturbed soil columns were colleted in these soils, in the depths from 0 to 0.5 m and from 0.5 to 1.0 m. In the disturbed soil samples were measured both macro and micronutriens, current and potential acidity, organic matter contend and particle size at depths of 0-0.1 m, 0.1-0.2 m, 0.2-0.3 m, 0.3-0.5 m and 0.5-1.0 m. To determine the porosity (macro, micro and total) of soil, undisturbed soil samples were colleted using Uhland extractor at the same depths of the disturbed ones. Soils described and sampled were the following: Latosol (non-hydromorphic), Cambisol (semi-hydromorphic) and Gleisol (hydromorphic). Urea and NPK equivalent to fertilization for one year and water equivalent to one year of rainfall were added into the soil columns. Concentrations of NO3- and NH4+ in eluate (water) samples and in the soils were determined by salicylate colorimetric method and FIA system (Flow Injection Analysis), respectively. The results were subjected to variance analysis and means compared by Tukey test at 5% probability, using the SAS program. From this experiment it a could be concluded that: (i) the elution water volume for surface soil columns (0.0-0.5 m) was higher for Gleisol and Latosol in relation to Cambisol, probably due to compaction of Cambisol and, in contrast, for subsurface soil columns (0.5-1.0 m), the elution water volume was higher in Cambisol than Latosol; (ii) in surface soil columns, N-NH4+ and N-N0-3 lixiviations were higher in Latosol in relation to Cambisol and Gleisol and, in subsurface soil columns, both N-NH4+ and N-N0-3 lixiviations were not significantly different in Latosol and Cambisol; (iii) there was higher N-NH4+ retention in Latosol in relation to Cambisol and Gleisol only in 0.0-0.1 m soil layer and a higher N-NH4+ retention in Cambisol and Gleisol in relation to Latosol only in 0.1-0.2 m soil layer, whereas with respect to N-N03-, there was no retention in any soil layers in studied soils; (iv) nitorogen lixiviation in the three soils was higher as N-NH4+ than N-N0-3.

Page generated in 0.024 seconds