• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1012
  • 352
  • 137
  • 111
  • 77
  • 72
  • 64
  • 43
  • 29
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • Tagged with
  • 2483
  • 395
  • 382
  • 373
  • 346
  • 336
  • 331
  • 318
  • 279
  • 231
  • 228
  • 219
  • 173
  • 172
  • 162
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

The effect of market power in emission permit markets /

Godby, Robert William. January 1900 (has links)
Thesis (Ph.D.) -- McMaster University, 1997. / Includes bibliographical references (p. 328-332). Also available via World Wide Web.
102

Stochastische Algorithmen zur Parameterschätzung in der Kompartmentanalyse von dynamischen Positronen-Emissions-Tomographischen Daten /

Schuth, Gerhard. January 1999 (has links)
Techn. Hochsch., Diss.--Aachen, 1999. / Auch als: Berichte des Forschungszentrums Jülich ; 3720. Mit engl. Zsfassung.
103

Effect of bone conduction transducer placement on distortion product otoacoustic emissions

Hazelbaker, Julie L., January 2004 (has links)
Thesis (Ph. D.)--Ohio State University, 2004. / Title from first page of PDF file. Document formatted into pages; contains xi, 102 p. : ill. (some col.). Advisor: Lawrence Feth, Dept. of Speech & Hearing Science. Includes bibliographical references (p. 97-102).
104

Occupational hearing loss in Hong Kong : screening with distortion product otoacoustic emission /

Chan, Sze-wen, Vanessa. January 2000 (has links)
Thesis (M. Sc.)--University of Hong Kong, 2000. / Includes bibliographical references (leaves 39-43).
105

Novel method of analysis for DPOAE magnitude and phase :

Adegoke, Modupe Florence. January 2010 (has links)
Honors Project--Smith College, Northampton, Mass., 2010. / Includes bibliographical references (p. 119-121).
106

Beiträge zur Einführung der Positronen-Emissions-Tomographie bei der Schwerionen-Tumortherapie /

Hinz, Rainer. January 2000 (has links)
Techn. Universiẗat, Diss., 2000--Dresden.
107

Fast-response FID measurement of SI engine residual gas hydrocarbon concentration

Summers, Tim January 1996 (has links)
No description available.
108

Air quality impact assessment of transport-related air pollutants

Clark, Alistair I. W. January 1984 (has links)
No description available.
109

Vliv provozních parametrů spalovacího procesu na koncentraci jemných částic ve spalinách biomasových kotlů / Impact of Operation Parameters on Fine Combustion Particles Concentration in the Flue Gas of Biomass Boilers

Poláčik, Ján January 2020 (has links)
This work deals with the impact of operating parameters on fine combustion particles formation in the flue gas of biomass combustion device. The research part of the work describes the properties of fine particles, its basic division, impact on human health and the environment. The basic knowledge of the influence of biomass combustion process on fine particles production up to 1 µm in size is summarized. The main part describes the experimental setup for evaluating the size distribution of fine particles. The following section describes the experimental setup with measured results for various combustion parameters in laboratory combustion, automatic boilers, as well as in the manual wood-burning combustion device. The main parameters which were tested were combustion temperature, oxygen amount, type of fuel and geometry of the burned biomass. The impact of individual parameters on the formation of the fine particles is evaluated. The final part of the thesis summarizes the ways in which it is possible to significantly influence the emissions of fine particles by the appropriate choice of combustion operating parameters.
110

Assessment of the left ventricular systolic and diastolic function in rats using electrocardiogram-gated cardiac positron emission tomography / Bestimmung der linksventrikulären systolischen und diastolischen Funktion in Ratten durch Elektrokardiogramm-getriggerte kardiale Positronen-Emissions-Tomographie

Eißler, Christoph Marcel January 2021 (has links) (PDF)
DD is a cardiac disturbance, which has gained increasing importance in recent years due to its important role in different cardiac disease and cardiomyopathies including ischemic cardiomyopathy, arterial hypertension and diabetic cardiomyopathy. ECG-gated 18F-FDG PET is an imaging technique, that can distinguish between districts of myocardial viability and myocardial scars and further provides information of great interest on the efficacy of experimental approaches designed to improve the cardiac function and/or myocardial metabolism in experimental small animal models. However, ECG-gated 18F-FDG PET is a technique whose feasibility in the assessment of the LV diastolic function in small animals has not been a subject of study. In this thesis, the ability of the ECG-gated 18F-FDG PET for the assessment of both the systolic and diastolic function in eight control rats and in seven ZDF rats, which are an experimental animal model mimicking T2DM conditions and diabetic related complications in humans including DCM, has been investigated The ECG-gated 18F-FDG PET imaging was performed under hyperinsulinemic-euglycemic clamping and the data were stored in list mode files and retrospectively reconstructed. The systolic and diastolic parameters were achieved from the time/volume and the time/filling curve calculated from the software HFV. Additionally, the influence of the number of gates per cardiac cycle on the LV volumes and function parameters has been studied. Hyperinsulinemic-euglycemic clamp procedure and blood glucose measurement did confirm the development of a manifest diabetes in the ZDF rats at the timepoint of the experiments. Regarding the systolic parameters, no significant difference could be detected between the ZDF and ZL rats. The values for the CO were similar in both groups, which demonstrates a similar LV systolic function in the ZDF and the ZL rats at the age of 13 weeks. Values for the systolic parameters are in good line with previous PET, MRI and cardiac catheterization-based studies in diabetic rats. The main finding of this study was that by using in vivo ECG-gated 18F-FDG PET and the software HFV, reliable diastolic parameters could be calculated. Moreover, it was possible to detect the presence of a mild impaired diastolic filling in the ZDF rats in absence of any systolic alteration. This impaired diastolic function in an early stage of diabetes could also be detected by other investigators, who used echocardiography or cardiac catheterization. Therefore, this is the first study showing, that the assessment of the diastolic function in rats can be carried out by ECG-gated 18F-FDG PET imaging. In conclusion, additionally to calculating LV volumes and LV EF, ECG-gated 18F-FDG PET can evaluate the diastolic function of healthy and diabetic rats and is able to detect a DD in ZDF rats. / Die DD ist eine Störung der Herzdynamik, welche, aufgrund ihrer Beteiligung in verschiedenen Herzerkrankungen und Kardiomyopathien wie der ischämischen Kardiomyopathie, der arteriellen Hypertonie und der diabetischen Kardiomyopathie, in den letzten Jahren zunehmend in das Interessenzentrum der Herzforschung gerückt ist. Die EKG-getriggerte 18F-FDG PET ist eine Bildgebungsmethode, welche die Unterscheidung von vitalem Myokard und Narben ermöglicht und zusätzlich noch in der Lage ist, wichtige Informationen zu erheben, welche von Bedeutung für die Beurteilung von experimentelle Behandlungen zur Verbesserung der Herzfunktion und/oder des kardialen Stoffwechsels in präklinischen Tiermodellen sind. Trotz dieser Möglichkeiten wurde bisher noch nicht die Fähigkeit der EKG-getriggerten 18F-FDG PET zur Bestimmung der LV diastoischen Funktion in Kleintiermodellen untersucht. Deshalb wurde in dieser Arbeit das Potential der EKG-getriggerten 18F-FDG PET in Bezug auf die Bestimmung der LV systolischen und diastolischen Funktion in acht Kontrollratten (ZL) und sieben ZDF-Ratten, welche eine experimentelles Tiermodell für T2DM und die damit verbundenen Komplikationen einschließlich der diabetischen Kardiomyopathie sind, untersucht. Die EKG-getriggerte 18F-FDG PET wurde unter der hyperinsulinämischen euglykämischen Klemm Methode durchgeführt, die Daten in „list-mode“ Dateien gespeichert und retrospektiv rekonstruiert. Die Berechnung der LV systolischen und diastolischen Parameter erfolge aus der Zeit-Volumen-Kurve und der Zeit-Füllungs-Kurve durch das Programm HFV. Zudem wurde der Einfluss der pro Rekonstruktion verwendeten „frames“ pro kardialen Zyklus auf die LV Volumina und die linksventrikulären Funktionsparameter untersucht. Durch die hyperinsulinämische euglykämische Klemm Methode und durch Blutglukose Messungen konnte die Entwicklung eines manifesten Diabetes zum Zeitpunkt der Experimente in den ZDF Ratten nachgewiesen werden. Es konnte kein signifikanter Unterschied zwischen den systolischen Parametern der ZDF und der ZL Ratten gefunden werden. Der kardiale Auswurf war nahezu identisch in den beiden Gruppen zum Zeitpunkt der Experimente, was eine vergleichbare systolische Funktion in beiden Gruppen demonstriert. Die erhobenen Werte für die systolischen Parameter befinden sich in guter Übereinstimmung mit den Werten der Literatur von vorherigen PET, MRT und Katheter-gestützten Experimenten in diabetischen Rattenmodellen. Ein wichtiges Ergebnis dieser Arbeit ist die Erhebung von verlässlichen diastolischen Parametern durch den kombinierten Einsatz von EKG-getriggerter 18F-FDG PET und HFV. Zudem war es möglich, eine gestörte diastolische Füllung des LV in den ZDF Ratten nachzuweisen, in Abwesenheit von systolischen Funktionseinschränkungen. Eine Beeinträchtigung der diastolischen Funktion in der frühen Phase des Diabetes wurde bereits in anderen Rattenstudien mittels Echokardiografie und Katheter basierten Untersuchungen gezeigt. Dennoch ist dies hier die erste Studie, welche demonstriert, dass die Bestimmung der diastolischen Funktion auch mit Hilfe der EKG-getriggerten 18F-FDG PET durchgeführt werden kann. In Zusammenfassung lässt sich festhalten, das zusätzlich zu der Bestimmung der LV-Volumina und der LVEF durch EKG-getriggerten 18F-FDG PET auch die Bestimmung der diastolischen Funktion in gesunden und diabetischen Ratten möglich ist und dass durch EKG-getriggerten 18F-FDG PET die Identifikation einer DD in ZDF Ratten möglich ist.

Page generated in 0.0336 seconds