• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Assessment of susceptibility corrosion of stainless steel super duplex UNS S32750 (SAF 2507) AND UNS S32760 (ZERON100) using a EPR portable cell / AvaliaÃÃo da susceptibilidade à corrosÃo dos aÃos inoxidÃveis super duplex UNS S32750 (SAF 2507) e UNS S32760 (ZERON100) utilizando uma cÃlula de EPR portÃtil

Caroliny Gomes de Oliveira 24 January 2014 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / The great demand for techniques that can detect and determine the degree of susceptibility to corrosion motivated thedevelopment of a research project that resulted in the construction of a portable electrochemical cell that has been validated according to ASTM A262. The success of this technique for nondestructive evaluation has motivated the expansion of this technique to other materials and phenomena of precipitation. In this work it was evaluated the use of this EPR-DL portable cell used applied for assessing the susceptibility to corrosion in super duplex stainless steels UNSS32750 and UNSS32760.Those materials were heat treated at 475ÂC and 850ÂC at different time of creating different patterns precipitation of deleterious phases to be detected by the cell. The solutions used were: 2M H2SO4 +0.01 M KSCN +0.5 M NaCl (solution 1 ) and 2M H2SO4 +0.01 M KSCN +1.0 M NaCl (solution 2) and the speedsscanswerestudied: 1.67 mV / s , 3.0 mV / s and 6.0 mV / s. To prove the presence of deleterious phases precipitation and associate them with the electrochemical behavior presentedby the electrochemical cell, the sampleshad theirmicrostructuresanalyzedby optical microscopy (OM), scanning electron microscopy (SEM), and energy dispersive of X-ray spectroscopy (EDS). Also the consumption of ferrite magnetic phase was assessed with ferrite scope and performed Vickers hardness tests to analyze the increasing in hardness due to precipitation of deleterious phases. It was observed by OM, SEM / EDS, ferrite scope, EPR- DL and Vickers hardness, that as much longer the heat treatment the amount of deleterious phasesprecipitated was increased. The results demonstrated that the solution 2 was the most effective in detecting susceptibility to corrosion, being capable to detect the depletion of chromium even in conditions of low precipitation and obtaining greater values of Ir/Ia as the scanning speed was reduced to the same condition of heat treatment. All these analyzes has confirmed that the EPR- DL portable cell was able to detect the depletionof chromium caused by the presence of deleterious phases, and reflecting the degree of susceptibility to corrosion of SDSS which were studied / A grande demanda por tÃcnicas que consigam detectar e determinar o grau de susceptibilidade à corrosÃo motivou o desenvolvimento de um projeto que resultou na construÃÃo de uma cÃlula portÃtil para a determinaÃÃo do fenÃmeno da sensitizaÃÃo em aÃos inoxidÃveis austenÃticos, a qual foi validada seguindo a norma ASTM A262. O sucesso desta tÃcnica nÃo destrutiva em campo tem motivado a expansÃo dessa tÃcnica de anÃlise para outros materiais e fenÃmenos de precipitaÃÃo. O presente trabalho apresenta a avaliaÃÃo dessa cÃlula portÃtil utilizada em ensaios de EPRâDL para avaliaÃÃo de susceptibilidade a corrosÃo nos AISD UNS S32750 e UNS S32760. Estes materiais foram tratados termicamente a 475ÂC e a 850ÂCem diferentes tempos, criando diferentes padrÃes de precipitaÃÃes de fases deletÃrias para serem detectados pela cÃlula. As soluÃÃes utilizadas foram: 2M de H2SO4+0,01M de KSCN+0,5 M de NaCl (soluÃÃo 1) e 2M de H2SO4+0,01M de KSCN+1,0 M de NaCl (soluÃÃo2) e as velocidades de varreduras estudadas foram de 1,67mV/s, 3,0mV/s e 6,0mV/s. Para comprovar a presenÃa da precipitaÃÃo de fases deletÃrias e associÃ-las ao comportamento eletroquÃmico apresentado pela cÃlula, as amostras tiveram suas microestruturas analisadas por microscopia Ãtica (MO), microscopia eletrÃnica de varredura (MEV),e ensaios com energia dispersiva de raios-X (EDS).TambÃm foram avaliados o consumo da fase ferrita por analise magnÃtica com ferritoscÃpio e realizados ensaios de dureza Vickers para analisar o aumento da dureza devido a precipitaÃÃo das fases deletÃrias. Foi observado por MO, MEV/ EDS, ferritoscÃpio, EPR-DL e por dureza Vickers que quando maior o tempo de tratamento tÃrmico maior foi a quantidade de fases deletÃrias precipitadas. Quanto maior foi o nÃvel de precipitaÃÃo, maiores foram os valores de Ir/Ia e maiores valores de dureza foram obtidos. Os resultados mostraram que a soluÃÃo 2 foi a mais eficaz na detecÃÃo da susceptibilidade a corrosÃo, conseguindo detectar o empobrecimento de cromo mesmo em condiÃÃes de baixa precipitaÃÃo, e obtendo maior valores de Ir/Ia conforme a velocidade de varredura era diminuÃda para uma mesma condiÃÃo de tratamento. Todas essas anÃlises comprovaram que a cÃlula portÃtil de EPR- DL foi capaz de detectar o empobrecimento de cromo ocasionado pela presenÃa das fases deletÃrias, e refletindo o grau de susceptibilidade a corrosÃo dos AISD estudados.

Page generated in 0.0177 seconds