• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do sistema cardiorrespiratório na capacidade funcional de exercício em gestantes com pré-eclâmpsia /

Silva, Evelise Guimarães da. January 2010 (has links)
Resumo: Avaliar o sistema cardiorrespiratório e sua influência na capacidade funcional de exercício em gestantes com pré-eclâmpsia. Estudo transversal com 50 gestantes portadoras de pré-eclâmpsia e 50 gestantes normotensas, estimado pelo tamanho amostral. Foi realizado espirometria, dopplerecocardiografia e teste de caminhada de seis minutos. Na análise estatística foi usado o teste t e Mann-Whitney para as variáveis com distribuição simétrica e assimétrica, respectivamente, e regressão múltipla linear. As variáveis espirométricas mostraram redução significativa da capacidade vital forçada (L) [3,35 (2,95; 3,74) ν 3,62 (3,31; 3,88) p=0,012], do volume expirado forçado no primeiro segundo (L) [2,85 (2,58; 3,16) ν 3,06 (2,83; 3,27) p=0,034] e da capacidade vital lenta (L) [3,34 (2,87; 3,91) ν 3,65 (3,32; 4,07) p=0,039], no grupo pré-eclâmpsia comparado com o grupo controle, respectivamente. Os valores do diâmetro sistólico (cm) [2,90 (2,7; 3) ν 2,7(2,65; 2,9) p=0,048] e diastólico do ventrículo esquerdo (cm) [4,8 (4,7; 5) ν 4,7 (4,55; 4,8) p=0,016], índice de massa do ventrículo esquerdo (g/m2,7) [48,65 (45,27; 52,12) ν 34,34 (31,57; 38,05) p<0,001], espessura relativa da parede ventricular esquerda (cm) [0,40 (0,38; 0,45) ν 0,34 (0,34; 0,35) p<0,001], volume sistólico (mL) [62,4 (58,57; 67,66) ν 58,19 (55,24; 63,18) p=0,014], tempo de relaxamento isovolumétrico do ventrículo esquerdo (ms) [88 (80; 92) ν 80 (76;84) p<0,001], tempo de desaceleração da onda E (ms) [196 (192;208) ν 192 (188;196) p=0,002] e onda A (cm/s) [64 (54;75) ν 49 (54;54) p<0,001] foram estatisticamente maiores no grupo préeclâmpsia que no controle. Enquanto que a razão E/A foi significativamente menor no grupo pré-eclâmpsia [1,40 (1,21; 1,63) ν 1,72 (1,55; 1,94) p<0,001]. A distância percorrida (m) no teste de caminhada de seis minutos foi significativamente menor... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To evaluate the cardio respiratory system and its influence on the functional exercise capacity of pregnant women with preeclampsia. Cross-sectional trial on 50 pregnant women with preeclampsia and 50 normotensive pregnant women, estimated by sample size. Spirometry, Doppler echocardiography and the six-minute walk test were performed. In statistical analysis, the t test and the Mann-Whitney test were respectively used for variables with symmetrical and asymmetrical distribution, in addition to multiple linear regression. Results: The spirometric variables showed significant reduction in forced vital capacity (L) 3.35 (2.95; 3.74) 3.62 (3.31; 3.88) p=0.012 , in forced expired volume in the first second (L) 2.85 (2.58; 3.16) 3.06 (2.83; 3.27) p=0.034 and in slow vital capacity (L) 3.34 (2.87; 3.91) 3.65 (3.32; 4.07) p=0.039 as compared to the control group, respectively. The values for systolic (cm) 2.90 (2.7; 3) 2.7(2.65; 2.9) p=0.048 and diastolic diameter of the left ventricle (cm) 4.8 (4.7; 5) 4.7 (4.55; 4.8) p=0.016 , mass index of the left ventricle (g/m2,7) 48.65 (45.27; 52.12) 34.34 (31.57; 38.05) p<0.001 , relative thickness of the left ventricular wall (cm) 0.40 (0.38; 0.45) 0.34 (0.34; 0.35) p<0.001 , systolic volume (mL) 62.4 (58.57; 67.66) 58.19 (55.24; 63.18) p=0.014 , isovolumetric relaxation time of the left ventricle (ms) 88 (80;92) 80 (76;84) p<0.001 , deceleration time of the E wave (ms) 196 (192;208) 192 (188;196) p=0.002 and the A wave (cm/s) 64 (54;75) 49 (54;54) p<0.001 were statistically larger in the preeclampsia group than in control while the E/A ratio was significantly smaller in the preeclampsia group 1.40 (1.21; 1.63) 1.72 (1.55; 1.94) p<0.001 . The distance walked (m) in the six-minute walk test was significantly smaller in the preeclampsia group (465± 61) than in the control group (534± 44) p<0.001. Linear multiple regression showed that, in the presence... (Complete abstract click electronic access below) / Orientador: José Carlos Peraçoli / Coorientador: Beatriz Bojikian Matsubara / Coorientador: Irma de Godoy / Banca: Victor Zuniga Dourado / Banca: Audrey Borghi e Silva / Banca: Vera Therezinha Medeiros Borges / Banca: Silméia Garcia Zanatti Bazan / Doutor
2

Avaliações cardiovasculares e comportamentais em gatos após a injeção intravenosa de amitraz ou xilazina /

Escobar, André. January 2007 (has links)
Orientador: Carlos Augusto Araújo Valadão / Banca: Paulo Sérgio Patto dos Santos / Banca: Anderson Farias / Resumo: Foram avaliados os efeitos cardiovasculares e comportamentais após a administração intravenosa de amitraz ou xilazina em oito gatos. Todos os animais foram submetidos aos três tratamentos, a saber: GXil - 1 mg/kg de xilazina; GAmz - 1 mg/kg de amitraz em diluente lipídico; e GDil - volume de diluente lipídico idêntico ao utilizado nos animais tratados com amitraz, respeitando-se um intervalo mínimo de 15 dias entre eles. Imediatamente antes dos tratamentos, avaliaram-se à pressão arterial sistólica (PAS), temperatura retal (T), freqüência respiratória (f), ritmo, freqüência (FC), índice (IC) e contratilidade cardíaca. Os demais registros foram realizados aos 5, 10, 15, 20, 30, 40, 50 e 60 minutos após os tratamentos. Empregou-se análise de variância (ANOVA) de uma única via e teste de Friedman, ambos seguidos pelo teste de Tukey (p=0,05), respectivamente para os dados paramétricos e não-paramétricos. Tanto o amitraz como a xilazina causaram bloqueios atrioventriculares de 1º grau e redução da FC, frações de ejeção (FE) e de encurtamento (FS), IC, PAS e T. Complexos ventriculares prematuros foram observados após a aplicação de amitraz ou do diluente, e a f aumentou. O amitraz induziu sedação menos intensa do que a xilazina. Conclui-se que ambos induzem bradicardia e BAV de 1º grau, observando-se maior depressão da contratilidade cardíaca para a xilazina. A dose empregada do amitraz produz efeito sedativo em gatos. / Abstract: To evaluate the cardiovascular and behavioral alterations, eight cats were submitted to amitraz or xylazine intravenous injection: GXil - 1 mg/kg of xylazine; GAmz - 1 mg/kg of amitraz; and GDil - diluent in equal volume used on GAmz. The same cats were used after a 15 day interval. Systolic arterial blood pressure (SAP), temperature (T), respiratory (RR) and heart rates (HR), cardiac index (CI), rhythm and contractility (ejection fraction - EF and shortening fraction - SF) were measured before treatments and 5, 10, 15, 20, 30, 40, 50 and 60 minutes after each treatment. One way analysis of variance (ANOVA) and Friedman test, followed by Tukey test (p=0.05), were used to compare parametric and non-parametric data, respectively. Amitraz and xylazine induced first-degree A-V block, decreased HR, EF, SF, CI, SAP and T. Ventricular premature complexes were noted after amitraz or diluent injection, and RR increased. Amitraz induced a lower sedative effect compared to xylazine. It was concluded that both a2-agonists produce bradycardia and first-degree A-V block, but xylazine causes greater cardiac contractility depression. Additionally, amitraz produces a sedative effect in cats. / Mestre

Page generated in 0.08 seconds