• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Traitement d'éffluents gazeux malodorants issus du secteur industriel du traitement des déchets par voie biologique : étude du couplage lit percolateur/biofiltre

Soupramanien, Alexandre 23 October 2012 (has links) (PDF)
Le secteur industriel du traitement des déchets génère des émissions gazeuses induisant des nuisances odorantes auprès des populations riveraines des installations. Ces effluents gazeux contiennent une grande diversité de composés volatils : oxygénés (acides gras volatils, cétones, aldéhydes, alcools), azotés et soufrés (hydrogène sulfuré (H2S), diméthylsulfure (DMS), diméthyldisulfure (DMDS) et méthanethiol (MT)). Ces effluents gazeux sont traités par un dispositif approprié que sont les bioprocédés. Néanmoins, les seuils de perception des composés odorants et plus particulièrement ceux des composés soufrés, très bas, obligent à atteindre des efficacités d'abattement particulièrement élevées, faute de quoi le résiduel de concentration peut être à l'origine d'un impact notable sur les populations riveraines. L'objectif de cette étude est donc d'améliorer les performances de ces procédés biologiques par la mise en oeuvre de filières de traitement. L'originalité de ce travail est d'évaluer les performances d'épuration d'un mélange de composés soufrés par la mise en oeuvre du couplage de deux procédés biologiques que sont le lit percolateur et le biofiltre.Le premier résultat de ce travail de thèse a consisté à évaluer l'impact du pH sur l'activité de dégradation de composés soufrés en mélange (H2S, DMS et DMDS) en mettant en oeuvre des microcosmes. La valeur du pH de la phase aqueuse a une influence sur l'efficacité d'élimination des DMS et DMDS. Une élimination complète de ces derniers est observée pour une gamme de pH comprise entre 5 et 7. Les performances de ce couplage ont été comparées avec celles observées dans le cas de biofiltres seuls (dupliquats). Après une phase d'acclimatation, un fonctionnement stable est maintenu en conditions opératoires stationnaires. Les potentialités du couplage ont été mises en évidence, les niveaux d'abattement des DMS et DMDS étant supérieurs (de l'ordre de 20%) pour le couplage de bioprocédés. La composante microbiologique a fait l'objet d'une attention particulière en évaluant les densités de deux populations connues pour dégrader ces composés soufrés (Hyphomicrobium et Thiobacillus thioparus) par q-PCR au sein du biofiltre couplé au filtre percolateur et des biofiltres de référence. Les résultats obtenus mettent en évidence la présence de ces deux populations à des taux élevés (104 copies du gène ADNr-16S/ng ADN extrait pour Thiobacillus thioparus et 104-106 copies du gène ADNr-16S/ng ADN extrait pour Hyphomicrobium). La répartition de ces deux populations est similaire dans les deux cas (couplage et biofiltres seuls).Face à des perturbations représentatives de celles observées sur site, la robustesse du couplage a pu être mise en évidence, les niveaux d'efficacité d'avant les chocs sont récupérés dans un délai inférieur ou égal à 72 heures après l'arrêt de la perturbation. Enfin, une application sur site (équarrissage) a été conduite sur une période de trois mois et a permis de valider les résultats de laboratoire et de montrer l'adaptabilité d'un tel système face à la variabilité d'un effluent réel.
2

Traitement d'éffluents gazeux malodorants issus du secteur industriel du traitement des déchets par voie biologique : étude du couplage lit percolateur/biofiltre / Biological treatment of malodorous gaseous compounds stemming from the industrial sector of waste management : study of a biotrickling filter/biofilter combination

Soupramanien, Alexandre 23 October 2012 (has links)
Le secteur industriel du traitement des déchets génère des émissions gazeuses induisant des nuisances odorantes auprès des populations riveraines des installations. Ces effluents gazeux contiennent une grande diversité de composés volatils : oxygénés (acides gras volatils, cétones, aldéhydes, alcools), azotés et soufrés (hydrogène sulfuré (H2S), diméthylsulfure (DMS), diméthyldisulfure (DMDS) et méthanethiol (MT)). Ces effluents gazeux sont traités par un dispositif approprié que sont les bioprocédés. Néanmoins, les seuils de perception des composés odorants et plus particulièrement ceux des composés soufrés, très bas, obligent à atteindre des efficacités d’abattement particulièrement élevées, faute de quoi le résiduel de concentration peut être à l’origine d’un impact notable sur les populations riveraines. L’objectif de cette étude est donc d’améliorer les performances de ces procédés biologiques par la mise en oeuvre de filières de traitement. L’originalité de ce travail est d’évaluer les performances d’épuration d’un mélange de composés soufrés par la mise en oeuvre du couplage de deux procédés biologiques que sont le lit percolateur et le biofiltre.Le premier résultat de ce travail de thèse a consisté à évaluer l’impact du pH sur l’activité de dégradation de composés soufrés en mélange (H2S, DMS et DMDS) en mettant en oeuvre des microcosmes. La valeur du pH de la phase aqueuse a une influence sur l’efficacité d’élimination des DMS et DMDS. Une élimination complète de ces derniers est observée pour une gamme de pH comprise entre 5 et 7. Les performances de ce couplage ont été comparées avec celles observées dans le cas de biofiltres seuls (dupliquats). Après une phase d’acclimatation, un fonctionnement stable est maintenu en conditions opératoires stationnaires. Les potentialités du couplage ont été mises en évidence, les niveaux d’abattement des DMS et DMDS étant supérieurs (de l’ordre de 20%) pour le couplage de bioprocédés. La composante microbiologique a fait l’objet d’une attention particulière en évaluant les densités de deux populations connues pour dégrader ces composés soufrés (Hyphomicrobium et Thiobacillus thioparus) par q-PCR au sein du biofiltre couplé au filtre percolateur et des biofiltres de référence. Les résultats obtenus mettent en évidence la présence de ces deux populations à des taux élevés (104 copies du gène ADNr-16S/ng ADN extrait pour Thiobacillus thioparus et 104-106 copies du gène ADNr-16S/ng ADN extrait pour Hyphomicrobium). La répartition de ces deux populations est similaire dans les deux cas (couplage et biofiltres seuls).Face à des perturbations représentatives de celles observées sur site, la robustesse du couplage a pu être mise en évidence, les niveaux d’efficacité d’avant les chocs sont récupérés dans un délai inférieur ou égal à 72 heures après l’arrêt de la perturbation. Enfin, une application sur site (équarrissage) a été conduite sur une période de trois mois et a permis de valider les résultats de laboratoire et de montrer l’adaptabilité d’un tel système face à la variabilité d’un effluent réel. / Waste treatment industries generate gaseous emissions that may induce odor annoyance to the surrounding populations. These gaseous effluents contain a large variety of volatile compounds such as oxygenated (volatile fatty acids, ketones, aldehydes and alcohols), nitrogen and sulphur compounds (hydrogen sulphide (H2S), dimethylsulphide (DMS), dimethyldisulfide (DMDS) and methanethiol (MT). These gaseous emissions are controlled by using an adequate system such as biotechniques. Nevertheless, because of their very low odor thresholds, complete elimination of sulphur compounds has to be assessed, as the residual concentration can induce an odorous impact on neighbourhood populations. The aim of this study is to improve these bioprocesses performances by carrying out an adequate system strategy. The originality of this work is to evaluate the removal efficiency of a mixture of sulphur compounds by implementing a combination of two bioprocesses and more precisely a biotrickling filter and biofilter.The first step of this PhD. work consisted of evaluating the pH impact on the biodegradation activity of a mixture of sulphur compounds (H2S, DMS and DMDS) by using microcosms. The pH has an impact on the removal efficiency of DMS and DMDS. The total removal of these compounds is observed for a pH range between 5 and 7. The performances of the coupling have been compared with those reached by implementing control biofilters (duplicated). After an acclimatization period, stable performances are maintained under constant operating conditions. The efficiency of the coupling have been highlighted, the DMS and DMDS abatement levels are superior (around 20%) for the bioprocesses combination.The microbiological component has been investigated within all biofilters by estimating the densities of two populations involved in the biodegradation of sulphur compounds (Hyphomicrobium and Thiobacillus thioparus), by using qPCR. The obtained results highlighted the presence of both populations at high level (104 copies of DNAr-16S gene/ng extracted DNA for Thiobacillus thioparus and 104-106 copies of DNAr-16S gene/ng extracted DNA for Hyphomicrobium). The repartition of these two bacterial populations is similar in both cases (coupling system and reference biofilters). Under transient shock load conditions, the robustness of the coupling has been revealed. The efficiency levels before the shock load are recovered 48 hours after the perturbation off. Finally, the monitoring of an on- site pilot (rendering facility) has been carried out during three months. The laboratory results have been confirmed and the suitability of such a system has been showed under industrial gas variability.
3

Étude et développement d'un procédé de traitement des odeurs par oxydation à l'ozone : application aux effluents gazeux d'usines de production de superphosphate / Study and development of an odor treatment process by ozone oxidation : application to gaseous effluents from superphosphate production plants

Vitola Pasetto, Leticia 18 July 2019 (has links)
Dans le procédé de production d’engrais à base de superphosphate, l’attaque de la roche phosphatée par l’acide sulfurique génère des sous-produits gazeux odorants. Bien que leurs émissions se situent dans les limites réglementaires, les usines d’engrais à base de superphosphate sont susceptibles de causer des nuisances olfactives pour les riverains. Cette thèse propose d’étudier la faisabilité d’un procédé de traitement des odeurs par l’ozonation en phase gazeuse homogène. Une première étape de priorisation des composés chimiques ayant le potentiel odorant le plus important a été réalisée. Ce classement a été effectué à partir d’un rapport technique fourni par notre partenaire industriel basé sur une campagne de mesure olfactométrique et de caractérisation chimique des gaz émis par la cheminée d’une usine de production des engrais superphosphate. À partir du calcul de la valeur d’activité odorante (OAV), deux familles de composés ont été ciblées : les composés soufrés – représentés par le sulfure d’hydrogène (H2S), le sulfure d’éthylméthyle (MES) et le disulfure de diméthyle (DMDS) – et les aldéhydes (représentés par le propanal et le butanal). Deux techniques analytiques (GC/FID et SIFT/MS) ont été mises en œuvre afin d’évaluer les performances d’élimination de ces composés, la difficulté d'analyser une matrice gazeuse contenant de l'ozone ayant été mise en évidence. Ainsi, une interférence de l'ozone sur l'analyse des aldéhydes par GC/FID a été identifiée. La technique SIFT/MS a, quant à elle, nécessité un développement important. L’ozonation d’effluents gazeux modèles a été réalisée en suivant l’élimination des composés cibles dans différentes conditions de fonctionnement (temps de résidence, température du réacteur, concentration en ozone et taux d’humidité) dans un domaine expérimental compatible avec les contraintes industrielles. Les composés soufrés ont présenté des taux d’élimination élevés, particulièrement dans le cas de H2S, dont les conversions ont atteint environ 80%. Les monosulfures (MES) et disulfures organiques (DMDS) se sont montrés moins réactifs à l’ozone, puisque les conversions sont restées assez faibles (de l’ordre de 30% pour un ratio O3/soufrés similaire). Dans la gamme de conditions opératoires utilisées, ni l'humidité, ni le temps de résidence dans le réacteur n’ont montré d'influence considérable. La concentration d'ozone s’avère être le paramètre du procédé le plus influant, ayant un effet positif sur les taux de conversion des trois composés soufrés étudiés. Parallèlement, pour le DMDS, une augmentation de la température du réacteur a aussi amélioré la conversion. De manière globale, les taux de conversion les plus importants ont été obtenus pour les ratio O3/soufrés et la température du réacteur les plus élevés. A l’inverse, même lorsque les conditions de réaction les plus favorables ont été appliquées (température et concentration d’ozone les plus élevées), les aldéhydes se sont montrés non réactifs vis-à-vis de l’ozone. Malgré les faibles conversions obtenues, l’utilisation du SIFT/MS a permis d’identifier les principaux sousproduits de la réaction ozone-composés soufrés en phase gazeuse comme étant le méthyléthylsulfoxyde (MESO), le méthyléthylsulfone (MESO2), le diméthyl thiosulfinate (DMSOS), les isomères de diméthyl thiosulfonate (DMSO2S), le diméthyldisulfoxyde (DM(SO)2) et également le dioxyde (SO2) et le trioxyde de soufre (SO3). Le procédé de traitement des odeurs par ozonation directe des gaz en sortie de cheminée industrielle apparaît donc difficilement envisageable en raison de la faible efficacité d’élimination des composés malodorants démontrée dans nos essais. En revanche, cette technique couplée avec une absorption chimique pourrait s’avérer intéressante pour éliminer les nuisances olfactives avec une bonne efficacité / In the superphosphate-based fertilizers production process, the attack of phosphate rock by sulfuric acid generates odorous gaseous by-products. Although their emissions are within regulatory limits, superphosphate fertilizer plants are likely to cause odor nuisance to residents. This thesis proposes to study the feasibility of a process of odor treatment by ozonation in homogeneous gas phase. A first step of prioritization of the chemical compounds with the most important odorous potential has been realized. This ranking was established from a technical report provided by our industrial partner based on a campaign of olfactometric measurement and chemical characterization of the gases emitted by the chimney of a superphosphate fertilizer production plant. From the calculation of the odor activity value (OAV), two families of compounds were targeted: sulfur compounds - represented by hydrogen sulphide (H2S), ethylmethyl sulphide (MES) and dimethyl disulfide (DMDS) - and aldehydes (represented by propanal and butanal). Two analytical techniques (GC/FID and SIFT/MS) were applied in order to evaluate the elimination performance of these compounds, the difficulty of analyzing a gaseous matrix containing ozone having been demonstrated. Thus, ozone interference on GC/FID analysis of aldehydes has been identified. The SIFT/MS technique, in turn, required significant development. The ozonation of model gaseous effluents was carried out following the elimination of the target compounds under different operating conditions (residence time, reactor temperature, ozone concentration and moisture) in an experimental field compatible with the industrial constraints. The sulfur compounds exhibited high removal rates, particularly in the case of H2S, whose conversions reached about 80%. Organic monosulfides (MES) and disulfides (DMDS) were less reactive to ozone, as conversions remained quite low (around 30% for the same level of O3/sulfur ratio). In the range of operating conditions used, neither the moisture nor the residence time in the reactor showed considerable influence. The ozone concentration is the most influential process parameter, having a positive effect on the conversion rates of the three sulfur compounds studied. Meanwhile, for DMDS, an increase in reactor temperature also improved the conversion. Overall, the highest conversion rates were obtained for the highest O3/sulfur ratios and reactor temperature. Conversely, even when the most favorable reaction conditions have been applied (highest temperature and ozone concentration), the aldehydes have been inert to ozone. Despite the low conversions obtained, the use of SIFT/MS has identified the main by-products of the ozone-sulfur compounds gas phase reaction as methylethylsulfoxide (MESO), methylethylsulfone (MESO2), dimethyl thiosulfinate (DMSOS), isomers of dimethyl thiosulfonate (DMSO2S), dimethyldisulfoxide (DM(SO)2) and also sulfur dioxide (SO2) and trioxide (SO3). The odors treatment process by direct ozonation of the gases at the outlet of industrial chimney thus appears difficult to envisage because of the low efficiency of malodorous compounds elimination demonstrated in our tests. On the other hand, this technique coupled with chemical absorption could be interesting to eliminate the olfactory nuisances with a good efficiency

Page generated in 0.1222 seconds