• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dimensionamento do volume útil de reservação de água considerando o consumo de energia elétrica no horário de ponta do setor elétrico / Dimension of useful volume of water reservoir considering the consumption of electricity in the time of attachment of the electrical sector

MOREIRA, Francisca Nara da Conceição 07 February 2018 (has links)
Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-05-15T17:47:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DimensionamentoVolumeUtil.pdf: 4176647 bytes, checksum: 3237cca508009d83a5fd01555078157d (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-05-15T17:49:04Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DimensionamentoVolumeUtil.pdf: 4176647 bytes, checksum: 3237cca508009d83a5fd01555078157d (MD5) / Made available in DSpace on 2018-05-15T17:49:04Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DimensionamentoVolumeUtil.pdf: 4176647 bytes, checksum: 3237cca508009d83a5fd01555078157d (MD5) Previous issue date: 2018-02-07 / Determinação do volume útil de reservação para eficiência hidroenergética em sistemas de abastecimento de água. A pesquisa foi realizada no sistema de bombeamento e reservação de água do Setor Guanabara, Ananindeua, Belém, Pará. Para isto, o trabalho foi dividido em três etapas, a saber, na primeira foram verificadas as condições de projeto e operacionais do Setor Guanabara para avaliação do desempenho hidroenergético. Na segunda Etapa foram determinados três (3) volumes teórico úteis de reservação, considerando diferentes métodos. Na terceira Etapa, considerando quatro (4) diferentes volume úteis, de projeto e três (3) teóricos, foram realizadas simulações hidroenergética para verificar o volume útil mais eficiente em termos hidroenergéticos. Para tanto, foi considerado a mesma curva de consumo e vazão média de bombeamento, porém, diferentes volumes úteis nas simulações. Na pesquisa foi verificado que o volume útil do reservatório elevado do Setor Guanabara não permite a redução do bombeamento de água no posto horário de ponta, o que, naturalmente, influencia no valor da despesa de energia elétrica e que o reservatório elevado estava sendo utilizado como “caixa de passagem”. Assim, foram estudadas três alternativas para modificar a atual situação operacional da unidade de reservação do Setor Guanabara, visando a redução do consumo e despesa de energia elétrica. No dimensionamento dos volumes úteis pelos 3 métodos estudados, foram obtidos 808,96 m³ com o Método da CETESB (1987), 936,77 m³ com os procedimentos recomendados na NBR 12.217 (1994) e 1.411,10 m³ quando foi utilizada o método proposto por Gomes (2012). Nas simulações realizadas no Epanet 2.0 resultou despesa de energia elétrica em R$ 25.789,54/mês para o volume útil do reservatório elevado projetado. De R$ 26.363,87/mês para o volume útil do reservatório elevado CETESB (1987). De R$ 26.191,71/mês para o volume útil do reservatório elevado NBR 12.217 (1994). E para o Método proposto por Gomes (2012) resultou em despesa mensal de R$ 14.698,95/mês. Contudo, a utilização do volume útil do reservatório dimensionado pelo Método de Gomes foi cerca de 66,39% superior ao da NBR 12.217 (1994), cerca de 64,56% superior ao de projeto e 57,33% superior ao CETESB (1987). Desse modo, o maior valor do volume impactará no valor a ser investido para a implantação do reservatório elevado. Por essa razão, na pesquisa foi estudada a economia com despesa de energia elétrica ao longo de 10 anos. Assim, considerando o Método de Gomes (2012) estimou-se economia de R$ 1.379.131,30 (78,19%) em relação ao Método da NBR 12.217 (1994) e de R$ 1.399.789,40 (79,36%) em relação ao Método da CETESB (1987). / Determination of the useful volume of reservation for hydroenergetic efficiency in water supply systems. The research was carried out in the Guanabara, Ananindeua, Belém, Pará Pumping and Water Reservation System. For this, the Guanabara Sector's design and operational conditions were verified for hydroenergetic performance evaluation. In the second step three (3) useful theoretical reservation volumes were determined, considering different methods. In the third stage, considering four (4) different useful project volumes and three (3) theoretical, hydroenergetic simulations were performed to verify the most efficient useful volume in hydroenergetic terms. For that, the same consumption curve and mean pumping rate were considered, but different useful volumes in the simulations. In the research it was verified that the useful volume of the high reservoir of the Guanabara Sector does not allow the reduction of water pumping at peak hours, which, naturally, influences the value of electric energy expenditure and that the high reservoir was being used as " junction box". Thus, three alternatives were studied to modify the current operating situation of the Guanabara Sector Reservation Unit, aiming at reducing electricity consumption and expenditure. In the sizing of the useful volumes by the 3 methods studied, 808.96 m³ were obtained with the CETESB Method (1987), 936.77 m³ with the procedures recommended in NBR 12.217 (1994) and 1.411,10 m³ when the proposed method was used by Gomes (2012). In the simulations carried out in Epanet 2.0 resulted in an electric energy expense of R$ 25.789,54/month for the useful volume of the projected high reservoir. From R$ 26.363,87/month for the useful volume of the high reservoir CETESB (1987). From R$ 26.191,71/month to the useful volume of the high reservoir NBR 12.217 (1994). And for the method proposed by Gomes (2012) resulted in monthly expenses of R$ 14.698,95/month. However, the utilization of the useful volume of the reservoir as measured by the Gomes Method was about 66,39% higher than that of NBR 12.217 (1994), about 64,56% higher than that of the project and 57,33% higher than CETESB (1987). In this way, the higher value of the volume will impact the value to be invested for the implantation of the raised reservoir. For this reason, in the research was studied the economy with expenditure of electric energy over 10 years. Accordingly, considering the Gomes Method (2012), savings of R $ 1.379.131,30 (78,19%) were estimated in relation to NBR 12.217 (1994) and R $ 1.399.789,40 (79,36%) in relation to the CETESB Method (1987).
2

Avaliação do desempenho hidroenergético do sistema de abastecimento de água Utinga – Bolonha – Setor Guanabara / Evaluation of the hydroenergy performance of the Utinga water supply system - Bolonha - Guanabara sector

DUARTE, Cinthya Karen Assunção do Rosário 29 May 2018 (has links)
Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-09-03T18:03:53Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoDesempenhoHidroenergetico.pdf: 2326573 bytes, checksum: 833b4db1f77c5150786565be917c7d2f (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-09-03T18:04:21Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoDesempenhoHidroenergetico.pdf: 2326573 bytes, checksum: 833b4db1f77c5150786565be917c7d2f (MD5) / Made available in DSpace on 2018-09-03T18:04:21Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoDesempenhoHidroenergetico.pdf: 2326573 bytes, checksum: 833b4db1f77c5150786565be917c7d2f (MD5) Previous issue date: 2018-05-29 / Água e energia são dois dos recursos mais importantes associados à sustentabilidade de municípios, regiões e países. Dentro desse contexto este trabalho tem como objetivo analisar a eficiência hidroenergética em sistemas de abastecimento de água. A pesquisa foi realizada em três etapas, tendo como área de estudo o setor Guanabara do SAA Utinga – Bolonha, localizado no município de Ananindeua/PA. Inicialmente foram obtidos dados operacionais e comerciais em documentos técnicos e realizadas visitas de campo. Em seguida, os dados levantados foram sistematizados e detalhados por unidade e grupo de unidades. Na última etapa foi empregada a matriz SWOT para analisar as forças, fraquezas, oportunidades e ameaças para a eficiência hidroenergética no setor Guanabara. Nos resultados foi verificado que grande parte do volume de água bombeado é perdido em vazamentos e/ou ligações clandestinas ou encaminhado para outras áreas. Também foi constatado o grande consumo de energia elétrica nos CMBs nos horários de ponta de tarifação, o que eleva as despesas e reduz a eficiência hidroenergética no setor Guanabara. Com a análise SWOT foi possível observar que, mesmo no atual cenário desfavorável, o SAA Utinga – Bolonha – Setor Guanabara pode alcançar índice de sustentabilidade hidroenergética adequado, desde que implementadas ações nos ambientes interno e aproveitadas as oportunidades no ambiente externo. Na pesquisa foi observado que o detalhamento dos dados é importante, bem como que a matriz SWOT pode ser utilizada para a análise da eficiência hidroenergética de sistemas de abastecimento de água. / Analyze the Hydroenergetic Efficiency in Water Supply Systems. The research was carried out in three stages, having as study area the Guanabara sector of SAA Utinga - Bologna, located in the municipality of Ananindeua / PA. Initially, operational and commercial data were obtained in technical documents and field visits were carried out. Then, the data collected were systematized and detailed by unit and group of units, as recommended by Pereira and Condurú (2014). In the last step, the SWOT matrix was used to analyze the strengths, weaknesses, opportunities and threats to hydroenergy efficiency in the Guanabara sector. In the results it was verified that much of the volume of pumped water is lost in leaks and / or clandestine connections or routed to other areas. It was also verified the great consumption of electric energy in the CMBs in the peak times of charging, which raises expenses and reduces the hydroenergetic efficiency in the Guanabara sector. With the SWOT analysis, it was possible to observe that, even in the current unfavorable scenario, the SAA Utinga - Bologna - Sector Guanabara can reach adequate hydroenergetic sustainability index, provided that actions are implemented in the internal environments and the opportunities in the external environment are taken advantage of. In the research it was observed that the detail of the data is important, as well as that the SWOT matrix can be used for the analysis of the hydroenergetic efficiency of water supply systems.
3

Otimização hidroenergética da operação de sistemas de distribuição de água

Sousa, Anselmo Claudino de 29 August 2013 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-11-12T17:15:36Z No. of bitstreams: 2 Dissertação - Anselmo Claudino de Sousa - 2013.pdf: 4168276 bytes, checksum: 160f3cce0baa970d16c2d97f90fe53ed (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2014-11-12T17:15:55Z (GMT) No. of bitstreams: 2 Dissertação - Anselmo Claudino de Sousa - 2013.pdf: 4168276 bytes, checksum: 160f3cce0baa970d16c2d97f90fe53ed (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-11-12T17:15:55Z (GMT). No. of bitstreams: 2 Dissertação - Anselmo Claudino de Sousa - 2013.pdf: 4168276 bytes, checksum: 160f3cce0baa970d16c2d97f90fe53ed (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-08-29 / The world population has becoming an urban society. The concentration of people in cities contributes to increase the demand on public services, especially on the water supply systems. Thus it is imperative that these systems are able to meet this growing supply of drinking water with lower operating costs. Requiring the supply companies, as well as expansion of these systems, the proper operation and efficient. In this work, a model for multi-objective optimization of the operation of the water distribution system was developed in order to achieve efficiency hydropower. Three objectives were considered: (i) reduction of real losses, (ii) reduction of the cost of electricity, and (iii) maximizing system reliability. The optimization model was designed for the construction of an interface between a hydraulic simulator and algorithms NSGAII and SPEA. The model system was applied to a hypothetical water distribution and it was proved to be suitable to generate an optimal set of operating rules. The use of multi-objective optimization model is recommend to promote the efficiency of hydropower water distribution systems existing in both macro and micro distribution. / A população mundial vem se consolidando como uma sociedade urbana. A concentração de pessoas nas cidades contribui para aumentar a demanda sobre os serviços públicos, principalmente sobre os sistemas de abastecimento de água. Dessa maneira é imprescindível que esses sistemas sejam capazes de atender a essa oferta crescente por água potável com menor custo operacional. Requerendo das companhias de abastecimento, além da expansão dos sistemas, a sua operação adequada e eficiente. Neste trabalho é desenvolvido um modelo multiobjetivo para otimização da operação de sistema de distribuição de água, visando alcançar a eficiência hidroenergética considerando três objetivos: (i) redução das perdas reais; (ii) redução do custo de energia elétrica; e (iii) maximização da confiabilidade do sistema. O modelo de otimização foi concebido pela construção de uma interface entre um simulador hidráulico e os algoritmos NSGAII e SPEA. O modelo foi aplicado a um sistema de distribuição de água hipotético, e demonstrou ser adequado para gerar um conjunto de regras operacionais ótimas. Recomenda-se o uso do modelo de otimização multiobjetivo para promover a eficiência hidroenergética de sistemas de distribuição de água existentes, tanto na macro quanto na micro distribuição.

Page generated in 0.0741 seconds