• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Wechselstromuntersuchung an Rohmilch mit dem Ziel der Zellzahlbestimmung / Alternating current investigation in raw milk with the aim of cell count determination

Hassan, Anwar 01 January 2005 (has links) (PDF)
Udder illnesses can have an essential influence on quantity and quality of the milk. A diagnosis is possible with the help of the deviation of milk contents, especially over the change of the somatic cells. The cell count consequently makes an important health and quality criterion of the milk. In order to determine the cell count and other contents directly after the vormilk, the relation between the count of the milk cells and the impedimetric quanities of the milk was examined systematically in a new measure cell with alternating current. The measurements were executed isotherm with different temperatures over a wide frequency area (10 Hz -13 MHz) and the results were compared with the cell counts obtained with standard procedures (Fossomatic). Relations between the measured complex electric quantities and the content of the milk like lactose and cell count were produced with help of statistical methods. No direct relation is found between the impedimetric qualities (complex condauctance, conductance or capacity) of milk and the number of cells found in it. Cause of that is the inhomogeneity of the cells, that varies considerably regarding their size and mass. The lactose concentration correlates good with impedimetric quantities (amplitude, phase shift, capacity and conductance) of milk. Particularly with the condactance of the milk a statistically secured relation is found over the entire frequency area (10 Hz - 13 MHz). The lactose concentration correlates on the other hand well with the cell count and makes a statistically secured prognosis of this quantity with high precision possible. Future it is possible to determine the cell count with the help of the complex conductivity, for what simple conductivity measuring instruments are suitable. / Eutererkrankungen können einen wesentlichen Einfluss auf Menge und Qualität der Milch haben. Eine Diagnose ist an Hand der Abweichung von Milchinhaltstoffen, insbesondere über die Veränderung der somatischen Zellen möglich. Die Zellzahl stellt somit ein wichtiges Gesundheits- und Qualitätskriterium der Milch. Um die Zellzahl und andere Inhaltsstoffe direkt nach dem ersten Gemelk zu bestimmen, wurde der Zusammenhang zwischen der Zahl der Milchzellen und den impedimetrischen Eigenschaften der Milch in neuartigen Messzelle mit Wechselstrom systematisch untersucht. Die Messungen wurden isotherm bei verschiedenen Temperaturen über einen weiten Frequenzbereich von 10 Hz - 13 MHz durchgeführt und die Ergebnisse mit denen nach Standardverfahren (Fossomatic) erhaltenen Zahlen verglichen. Mit Hilfe statistischer Methoden wurden Relationen zwischen den erhaltenen komplexen elektrischen Größen und den Inhaltstoffen der Milch wie Laktose und Zellzahl hergestellt. Es konnte kein direkter Zusammenhang zwischen den impedimetrischen Eigenschaften (komplexer Leitwert, Wirkleitwert oder Kapazität) der Milch und der Zahl darin befindlicher Zellen gefunden werden. Ursache dafür ist die Inhomogenität der Zellen, die hinsichtlich ihrer Größe und Masse beträchtlich variieren. Dagegen lässt sich die Laktosekonzentration gut mit den impedimetrischen Eigenschaften (Amplitude, Phasenverschiebung, Kapazität und Wirkleitwert) der Milch korrelieren. Besonders mit dem Wirkleitwert der Milch ist ein statistisch abgesicherter Zusammenhang über den gesamten Frequenzbereich (10 Hz bis 13 MHz) zu finden. Die Laktosekonzentration wiederum korreliert gut mit der Zellzahl und ermöglicht mit hoher Genauigkeit eine statistisch gesicherte Voraussage dieser Größe. Damit ist es möglich, zukünftig die Zellzahl über den Laktosegehalt anhand der komplexen Leitfähigkeit zu bestimmen, wozu einfache Leitfähigkeitsmessgeräte geeignet sind.
2

Wechselstromuntersuchung an Rohmilch mit dem Ziel der Zellzahlbestimmung

Hassan, Anwar 26 November 2004 (has links)
Udder illnesses can have an essential influence on quantity and quality of the milk. A diagnosis is possible with the help of the deviation of milk contents, especially over the change of the somatic cells. The cell count consequently makes an important health and quality criterion of the milk. In order to determine the cell count and other contents directly after the vormilk, the relation between the count of the milk cells and the impedimetric quanities of the milk was examined systematically in a new measure cell with alternating current. The measurements were executed isotherm with different temperatures over a wide frequency area (10 Hz -13 MHz) and the results were compared with the cell counts obtained with standard procedures (Fossomatic). Relations between the measured complex electric quantities and the content of the milk like lactose and cell count were produced with help of statistical methods. No direct relation is found between the impedimetric qualities (complex condauctance, conductance or capacity) of milk and the number of cells found in it. Cause of that is the inhomogeneity of the cells, that varies considerably regarding their size and mass. The lactose concentration correlates good with impedimetric quantities (amplitude, phase shift, capacity and conductance) of milk. Particularly with the condactance of the milk a statistically secured relation is found over the entire frequency area (10 Hz - 13 MHz). The lactose concentration correlates on the other hand well with the cell count and makes a statistically secured prognosis of this quantity with high precision possible. Future it is possible to determine the cell count with the help of the complex conductivity, for what simple conductivity measuring instruments are suitable. / Eutererkrankungen können einen wesentlichen Einfluss auf Menge und Qualität der Milch haben. Eine Diagnose ist an Hand der Abweichung von Milchinhaltstoffen, insbesondere über die Veränderung der somatischen Zellen möglich. Die Zellzahl stellt somit ein wichtiges Gesundheits- und Qualitätskriterium der Milch. Um die Zellzahl und andere Inhaltsstoffe direkt nach dem ersten Gemelk zu bestimmen, wurde der Zusammenhang zwischen der Zahl der Milchzellen und den impedimetrischen Eigenschaften der Milch in neuartigen Messzelle mit Wechselstrom systematisch untersucht. Die Messungen wurden isotherm bei verschiedenen Temperaturen über einen weiten Frequenzbereich von 10 Hz - 13 MHz durchgeführt und die Ergebnisse mit denen nach Standardverfahren (Fossomatic) erhaltenen Zahlen verglichen. Mit Hilfe statistischer Methoden wurden Relationen zwischen den erhaltenen komplexen elektrischen Größen und den Inhaltstoffen der Milch wie Laktose und Zellzahl hergestellt. Es konnte kein direkter Zusammenhang zwischen den impedimetrischen Eigenschaften (komplexer Leitwert, Wirkleitwert oder Kapazität) der Milch und der Zahl darin befindlicher Zellen gefunden werden. Ursache dafür ist die Inhomogenität der Zellen, die hinsichtlich ihrer Größe und Masse beträchtlich variieren. Dagegen lässt sich die Laktosekonzentration gut mit den impedimetrischen Eigenschaften (Amplitude, Phasenverschiebung, Kapazität und Wirkleitwert) der Milch korrelieren. Besonders mit dem Wirkleitwert der Milch ist ein statistisch abgesicherter Zusammenhang über den gesamten Frequenzbereich (10 Hz bis 13 MHz) zu finden. Die Laktosekonzentration wiederum korreliert gut mit der Zellzahl und ermöglicht mit hoher Genauigkeit eine statistisch gesicherte Voraussage dieser Größe. Damit ist es möglich, zukünftig die Zellzahl über den Laktosegehalt anhand der komplexen Leitfähigkeit zu bestimmen, wozu einfache Leitfähigkeitsmessgeräte geeignet sind.

Page generated in 0.0562 seconds