• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Simulation-based approaches in financial econometrics /

Sjölander, Pär, January 2007 (has links)
Diss. (sammanfattning) Jönköping : Internationella handelshögskolan, 2007.
2

Estimating CO2 reductions from renewable energy sources : The impact of power system nonlinearities / Uppskattning av förnybara energikällors inverkan på koldioxidutsläppen från elsystemet : en undersökning av icke-linjära faktorer

Berglund, Kristoffer January 2022 (has links)
Replacing conventional generation with renewable generation in power systems is essential for reducing CO2 emissions. It is important to know how effective renewables are in reducing CO2 emissions. Since CO2 reduction cannot be measured directly, different methods have been used to estimate reduction of CO2 emissions. The two most common methods are econometric models and dispatch models. Econometric models apply regression analysis using historical data for CO2 emissions, power production, and electricity demand to estimate CO2 reduction. On the other hand, dispatch models are detailed optimization simulations of power systems where the objective is to calculate the cost-optimal dispatch of the power plants. The dispatch model finds the optimal dispatch for a base case and counterfactual case. In the counterfactual case, the renewable generation in the system is modified. From the difference in CO2 emissions between the two cases, an estimation of CO2 reduction can be made. Recent studies have shown that dispatch models and econometric models can give different estimations of CO2 reduction. However, these studies did not include several factors that can increase CO2 emissions, such as; transmission constraints, security requirements, and non-linear factors. Examples of non-linear factors are; minimum dispatched energy of generating units, start up emissions, minimum up- and downtime for generating units, and energy generated during start-up and shut-down. This thesis examines if there is an agreement between econometric models and dispatch models for estimating CO2 reduction and if the agreement changes when more non-linear factors are considered. To examine these questions a systematic comparison has been done. Two econometric models are constructed, a linear econometric model and a polynomial linear econometric model. The polynomial linear econometric model is constructed to take into account non-linear factors. Eight dispatch models are constructed with increasing modelling complexity. Four model versions do not include any non-linear factors and four include non-linear factors. The results showed that the agreement between econometric and dispatch models is fairly good, except for versions that contain transmission constraints. The simulation is executed in a fictional test system that is not dimensioned for wind power generation at the given buses. Therefore is possible that transmission constraints impacts the reduction of CO2 too heavily. Furthermore, the results show that the non-linear factors contribute to CO2 emission and consequently lower the estimation of CO2 reduction. However, no conclusion can be made if the agreement between econometric and dispatch models divert when more non-linear factors are considered. / Världens utsläpp av CO2 måste minska för att inte jorden ska drabbas av drastiska klimatförändringar som temperaturhöjningar. Idag står elproduktionen för ungefär en fjärdedel av världens utsläpp av CO2. Därmed måste dagens elproduktion och elkraftsystem minska sina utsläpp av CO2 . Ett viktigt verktyg för att kraftsystem ska minska sina utsläpp av CO2 är expansion av förnybar elproduktion. Dock så går det inte att mäta direkt hur mycket CO2-utsläppen minskar vid expansion av förnybar elproduktion. Därför har flera olika estimeringsmetoder utvecklats för att uppskatta CO2-reduktion. De två vanligaste metoderna är ekonometriska modeller och produktionssimuleringsmodeller. Ekonometriska modeller använder sig av regressionsanalys med historiska tidsserier som; CO2 -utsläpp, kraftproduktion och elförbrukning för att uppskata CO2 -minskningen. Produktionssimuleringsmodeller är detaljerade optimeringssimuleringar där avsikten är att beräkna den kostoptimala användningen av kraftverk i ett system. Tidigare studier har visat att ekonometriska modeller och produktionssimuleringsmodeller kan ge olika uppskattningar av CO2 -reduktion. Dock har produktionssimuleringsmodellerna i studierna inte tagit hänsyn till flera faktorer som kan påverka CO2-utsläppen, som t.ex. överföringsbegränsningar, säkerhetsbegräsningar och icke-linjära faktorer. Exempel på icke-linjära faktorer är minimal produktion av energi för varje kraftverk, CO2 -utsläpp vi uppstart, minimal upp- och nertid och produktion vid uppstart och nedstänging för varje generator. Den här uppsatsen undersöker om de två metoderna ekonometriska modeller och produktionssimuleringsmodeller liknade uppskattningar av CO2 -reduktion och hur överrenstämmelsen mellan modellerna påverkas när man beaktar icke-linjära faktorer. För att försöka besvara dessa frågor har en systematisk jämförelse utförts. Två ekonometriska modeller har konstruerats, en linjär och en polynom-linjär ekonometrisk modell. Den polynom-linjära ekonometriska modellen tar i beaktning icke-linjära faktorer. Åtta produktionssimuleringsmodeller har konstruerats och de åtta olika modellerna har formulerats i en ökande ordning av noggrannhet. Fyra av modellerna tar inte hänsyn till några icke-linjära faktorer och fyra av modellerrna tar hänsyn till icke-linjära faktorer.

Page generated in 0.0611 seconds