• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da tenacidade à fratura de soldas de alta resistência e baixa liga pelo método da integral-J. / Evaluation of high strength low alloy steel weld metal fracture toughness using the J-integral method.

Silva, Rosana Vilarim da 24 June 1998 (has links)
Foi avaliada a influência da microestrutura na tenacidade à fratura de dois grupos de aços de Alta Resistência e Baixa Liga (ARBL), soldados, com diferentes composições microestruturais. Os metais de solda designados por A1/A2 exibiram uma microestrutura composta por ferrita acicular circundada por ferrita de contorno de grão, com alguma formação de ferrita Widmanstätten e microfases, denominada de microestrutura do tipo clássica. Os metais de solda designados por B1/B2 exibiram um microestrutura composta por bainita, martensita de baixo teor de carbono e microfases, denominada de microestrutura do tipo de ripas. Estes dois tipos de microestruturas são normalmente encontradas nas soldas de alta resistência empregadas em estruturas e componentes de grande responsabilidade. A avaliação da tenacidade à fratura foi realizada pela utilização dos conceitos da integral-J e CTOD. A técnica empregada para a medida do crescimento da trinca, foi a da variação da flexibilidade elástica em corpos de prova SE[B] e C(T). Os valores da tenacidade à fratura dos dois grupos de soldas, para ambas geometrias de corpos de prova, foram determinados e comparados. As análises microestruturais, do metal de solda e das superfícies de fratura dos corpos de prova ensaiados, foram realizadas por meio de microscopia ótica e eletrônica de varredura, com o objetivo de se correlacionar os valores de tenacidade à fratura com a microestrutura dos metais de solda. Foi verificado que os metais de solda A1/A2 que possuem uma microestrutura clássica, apresentaram tenacidade superior aos metais de solda B1/B2, que possuem uma microestrutura do tipo de ripas. / The influence of the microstructure on the fracture toughness behaviour of two groups of multipass High Strength Low Alloy (HSLA) steel weld metals, presenting different microstructure composition, was evaluated. The weld metals A1/A2 exhibited a microstructure composed by acicular ferrite, allotriomorphic ferrite, Widmanstätten ferrite and microphases, and the weld metals B1/B2 presented a microstructure composed by bainite, low carbon martensite and microphases. The fracture toughness evaluation was carried out using J-integral and CTOD concepts and the elastic compliance technique in both SE[B] and CT testpieces. The fracture toughness values for both groups of welds and testpiece geometry were determined and compared. The weld metals microstructures and fracture surfaces analysis were performed using optical and scanning electronic microscope techniques, to correlate the determined fracture toughness values, with the local microstructure around the fatigue crack tip. It was verified that the weld metals A1/A2 exhibited fracture toughness values superior to the ones obtained from weld metals B1/B2.
2

Avaliação da tenacidade à fratura de soldas de alta resistência e baixa liga pelo método da integral-J. / Evaluation of high strength low alloy steel weld metal fracture toughness using the J-integral method.

Rosana Vilarim da Silva 24 June 1998 (has links)
Foi avaliada a influência da microestrutura na tenacidade à fratura de dois grupos de aços de Alta Resistência e Baixa Liga (ARBL), soldados, com diferentes composições microestruturais. Os metais de solda designados por A1/A2 exibiram uma microestrutura composta por ferrita acicular circundada por ferrita de contorno de grão, com alguma formação de ferrita Widmanstätten e microfases, denominada de microestrutura do tipo clássica. Os metais de solda designados por B1/B2 exibiram um microestrutura composta por bainita, martensita de baixo teor de carbono e microfases, denominada de microestrutura do tipo de ripas. Estes dois tipos de microestruturas são normalmente encontradas nas soldas de alta resistência empregadas em estruturas e componentes de grande responsabilidade. A avaliação da tenacidade à fratura foi realizada pela utilização dos conceitos da integral-J e CTOD. A técnica empregada para a medida do crescimento da trinca, foi a da variação da flexibilidade elástica em corpos de prova SE[B] e C(T). Os valores da tenacidade à fratura dos dois grupos de soldas, para ambas geometrias de corpos de prova, foram determinados e comparados. As análises microestruturais, do metal de solda e das superfícies de fratura dos corpos de prova ensaiados, foram realizadas por meio de microscopia ótica e eletrônica de varredura, com o objetivo de se correlacionar os valores de tenacidade à fratura com a microestrutura dos metais de solda. Foi verificado que os metais de solda A1/A2 que possuem uma microestrutura clássica, apresentaram tenacidade superior aos metais de solda B1/B2, que possuem uma microestrutura do tipo de ripas. / The influence of the microstructure on the fracture toughness behaviour of two groups of multipass High Strength Low Alloy (HSLA) steel weld metals, presenting different microstructure composition, was evaluated. The weld metals A1/A2 exhibited a microstructure composed by acicular ferrite, allotriomorphic ferrite, Widmanstätten ferrite and microphases, and the weld metals B1/B2 presented a microstructure composed by bainite, low carbon martensite and microphases. The fracture toughness evaluation was carried out using J-integral and CTOD concepts and the elastic compliance technique in both SE[B] and CT testpieces. The fracture toughness values for both groups of welds and testpiece geometry were determined and compared. The weld metals microstructures and fracture surfaces analysis were performed using optical and scanning electronic microscope techniques, to correlate the determined fracture toughness values, with the local microstructure around the fatigue crack tip. It was verified that the weld metals A1/A2 exhibited fracture toughness values superior to the ones obtained from weld metals B1/B2.
3

Avaliação da tenacidade à fratura de aço API 5L X70 utilizado na fabricação de dutos transportadores de gás e petróleo / Fracture toughness evaluation of an API 5L X70 steel used in pipeline for gas and petroleum transportation

Francisco, Julio Cesar de Souza 17 April 2009 (has links)
A avaliação da integridade estrutural de dutos pelo uso de corpos-de-prova laboratoriais depende da escolha de corpos-de-prova de geometrias que representem condições de restrições plásticas na frente da trinca, similares às encontradas nas condições operacionais dos dutos. O Núcleo de Ensaios de Materiais e Análise de Falhas, NEMAF do SMM, EESC-USP vem realizando pesquisas para o desenvolvimento de corpos-de-prova e metodologias experimentais que melhor represente esta situação. Entretanto, no caso de dutos existem situações onde a geometria e o tamanho do corpo-de-prova são limitados pelas dimensões do duto. Este trabalho apresenta o desenvolvimento e aplicação de espécimes SE(T) em aço API 5L X70, avaliando a influência da geometria e dimensões do corpo-de-prova na tenacidade à fratura do citado aço, sendo este utilizado na fabricação de dutos para transporte de gás e petróleo. Para isto, foram obtidas curvas de resistência à propagação dúctil de trincas, curvas J-R\'s, utilizando a metodologia do espécime único (single specimen) em conjunto com a técnica da variação da flexibilidade elástica (unloading elastic compliance), medida na boca da trinca (CMOD) que fornece ao mesmo tempo a área plástica abaixo da curva de carregamento versus deslocamento e o tamanho da trinca, segundo a norma de ensaios ASTM E1820-05. Foram ensaiados corpos-de-prova SE(T) com trincas rasa (a/W=0,2) e profunda (a/W=0,5) e razão W/B de 2,5 e 1,0, com a finalidade de garantir que o ensaio seja realizado em dominância de um estado plano de deformação como recomendado pela referida norma, para outros tipos de corpos-de-prova. Dos resultados observou-se que, independente do tamanho de trinca inicial adotado, não foram observadas diferenças significativas nas curvas J-R. Este fato pode ser comprovado nos casos de W/B = 2,5 e 1,0, sendo obtidas curvas J-R similares para cada caso, independente do valor de a/W. Entretanto, na grande maioria dos CDP\'s, foi obtida uma propagação dúctil de trinca anômala, ou seja, trincas que apresentam um tunelamento acentuado, decorrente de um elevado estado de tensão plana próximo das laterais, mesmo com o entalhe lateral de 20% da espessura. Os corpos-de-prova com W/B = 1,0 foram capazes de produzir curvas J-R, sem que as trincas apresentassem tunelamento e que os valores médios de trinca (ai e af) medidos conforme a norma (ASTM, 2005), são bastante próximos dos valores obtidos pelo método da variação de flexibilidade elástica. As razões para este fato são discutidas em detalhes. De um modo geral as delaminações, quando existente, não permitem uma correta medição do tamanho de trinca. Ainda, contrário à observação de outros pesquisadores, neste trabalho, foi observado que em vários casos as delaminações induziram fratura instável. / The evaluation of pipes´ structural integrity from laboratories specimens depends on choosing the right specimen geometry that is able to present the conditions of plastic constrain at the crack tip, similar to the one found in the pipes´ operational conditions. The NEMAF Group from SMM, EESC-USP has been performing studies in this area, trying to develop specimen´s geometry that is able to represent this situation, as well as the necessary experimental methodologies to evaluate the fracture toughness of pipes. However, in some cases, the pipe size is a limiting factor in determining the specimen size and geometry. In this work is presented the development and application of specimens SE(T), evaluating the influence of the geometry and dimensions of the specimens on the fracture toughness of API 5L X70 steel, regularly used in the pipes for gas and petroleum transportation. Therefore, the resistance curves to ductile crack propagation, J-R`s curves, using the single specimen methodology, together with the variation of the elastic compliance technique (multiple unloading), measure at the crack mouth (CMOD) that provides both the plastic area under the load x displacement curve and crack size, according to the ASTM E1820-05 standard. The SE(T) specimens with shallow (a/W=0.2) and deep (a/W=0.5) cracks and W/B ratio of 2.5 and 1.0 trying to reduce the amount of plastic deformation and a straight crack front, as well as a dominance of a plane strain state at the crack tip, as recommended by the ASTM E1820-05 standard for other specimens type. From the results it was observed that, independent of the initial a/W, no significant differences were observed in the J-R curves. This fact is verified in both cases, this is, W/B = 2.5 and 1.0. However, in the great majority of CDP\'s with W/B = 2.5, it was obtained an anomalous crack propagation during testing, in other words, they presented an accentuated tunneling due to a high plane tension state near the CDP´s lateral faces, even with the side groove of 20% thickness. The specimens with W/B = 1.0 were capable to produce J-R curves with straight crack fronts, this is, without tunneling, allowing the measurement of medium values of the crack (ai e af) according to the ASTM E1820-05 standard. The reasons for this fact are discussed in details in this work. In general, the split, when present, did not allow a correct crack size measurement. Still, contrary to the other researchers\' observation, in this work, it was observed that in several cases the splits were able to induced unstable fracture.
4

Desenvolvimento de metodologia experimental para aplicação de espécimes SE(T) para avaliação de integridade estrutural em dutos / Development of an experimental methodology for application of SE(T) specimens for pipeline structural integrity evaluation

Piovatto, Roberto Reato 01 June 2007 (has links)
Este trabalho apresenta o desenvolvimento e aplicação de espécimes SE(T) em aço API X60 para avaliação de integridade estrutural em dutos condutores de gás e petróleo, o qual consiste na implantação de três técnicas que forneçam as curvas de resistência à propagação dútil de trincas, curvas J-Rs. As metodologias utilizadas foram a da variação da flexibilidade elástica, da queda de potencial elétrico e da normalização linear da carga, nas quais duas análises são verificadas para obtenção da área plástica abaixo da curva de carregamento. A primeira, através da medida do deslocamento da linha de carga e a segunda, pelo deslocamento do extensômetro colocado na boca da trinca. Foram ensaiados corpos de prova SE(T) com trincas rasa (a/W = 0,2) e profunda (a/W = 0,5) e os resultados obtidos permitiram observar a iniciação da propagação por rasgamento dúctil e discutir os limites das metodologias aplicadas. Os resultados mostraram que é possível obter as curvas J-Rs medindo o deslocamento na boca da trinca, podendo-se converter os deslocamentos de CMOD em deslocamentos do LLD. Foi constatada também que a técnica de normalização linear da carga é a que possibilitou o menor tempo de preparação e execução do ensaio, por utilizar apenas a medição do CMOD e não necessitar da realização dos descarregamentos. A variação da flexibilidade elástica é uma técnica rápida e confiável e não sofre alterações devido às delaminações. Já a técnica de queda do potencial elétrico se mostrou a mais consistente para o caso de a/W = 0,5, porém no caso de trincas curtas, a plasticidade desenvolvida na frente da trinca influencia nas medições causando imprecisões. As curvas J-Rs são deslocadas para a esquerda quando o tamanho inicial de trinca é reduzido, isto é, ocorre um aumento na energia de iniciação da propagação, JIC. / This work presents the development and application of SE(T) type specimen for structural integrity evaluation of pipeline steels used for gas and oil transportation, and it consists of the implementation of different techniques to provide the crack growth resistance curves, J-R curves. The methodologies used for crack growth measurement were: the elastic compliance, the electrical potential drop and the linear normalization techniques. Two techniques to provide the plastic area, Apl under the load versus displacement curve were used to evaluate Jpl, one based on the load line displacement, LLD, and the other based on the crack mouth opening displacement, CMOD. SE(T) specimens with two different initial crack size, denominate as shallow crack (a0/W = 0.2) and deep crack (a0/W = 0.5). The obtained results allowed the determination of the ductile tearing initiation point and to discuss the limits of the methodologies applied. It was proved be possible to get J-R curves using only one extensometer to measure the CMOD, which provides both crack size and Apl. The linear normalization technique is the one that provided the lower preparation and testing time, since there is no need of multiples unloading for crack growth measurement. The elastic compliance is a very easy, fast and reliable technique, and it is not sensible to the effect of the occurrence of delaminations, as it was the linear normalization technique. The electrical potential drop technique proved to very consistent for a0/W = 0.5, however in the case of shallow cracks the developed plasticity at the crack tip affected the measurements. The J-R curves were displaced to the left as the initial crack size is reduced, this is, there is an increase in the energy for crack tearing initiation, JIC.
5

Avaliação da tenacidade à fratura de aço API 5L X70 utilizado na fabricação de dutos transportadores de gás e petróleo / Fracture toughness evaluation of an API 5L X70 steel used in pipeline for gas and petroleum transportation

Julio Cesar de Souza Francisco 17 April 2009 (has links)
A avaliação da integridade estrutural de dutos pelo uso de corpos-de-prova laboratoriais depende da escolha de corpos-de-prova de geometrias que representem condições de restrições plásticas na frente da trinca, similares às encontradas nas condições operacionais dos dutos. O Núcleo de Ensaios de Materiais e Análise de Falhas, NEMAF do SMM, EESC-USP vem realizando pesquisas para o desenvolvimento de corpos-de-prova e metodologias experimentais que melhor represente esta situação. Entretanto, no caso de dutos existem situações onde a geometria e o tamanho do corpo-de-prova são limitados pelas dimensões do duto. Este trabalho apresenta o desenvolvimento e aplicação de espécimes SE(T) em aço API 5L X70, avaliando a influência da geometria e dimensões do corpo-de-prova na tenacidade à fratura do citado aço, sendo este utilizado na fabricação de dutos para transporte de gás e petróleo. Para isto, foram obtidas curvas de resistência à propagação dúctil de trincas, curvas J-R\'s, utilizando a metodologia do espécime único (single specimen) em conjunto com a técnica da variação da flexibilidade elástica (unloading elastic compliance), medida na boca da trinca (CMOD) que fornece ao mesmo tempo a área plástica abaixo da curva de carregamento versus deslocamento e o tamanho da trinca, segundo a norma de ensaios ASTM E1820-05. Foram ensaiados corpos-de-prova SE(T) com trincas rasa (a/W=0,2) e profunda (a/W=0,5) e razão W/B de 2,5 e 1,0, com a finalidade de garantir que o ensaio seja realizado em dominância de um estado plano de deformação como recomendado pela referida norma, para outros tipos de corpos-de-prova. Dos resultados observou-se que, independente do tamanho de trinca inicial adotado, não foram observadas diferenças significativas nas curvas J-R. Este fato pode ser comprovado nos casos de W/B = 2,5 e 1,0, sendo obtidas curvas J-R similares para cada caso, independente do valor de a/W. Entretanto, na grande maioria dos CDP\'s, foi obtida uma propagação dúctil de trinca anômala, ou seja, trincas que apresentam um tunelamento acentuado, decorrente de um elevado estado de tensão plana próximo das laterais, mesmo com o entalhe lateral de 20% da espessura. Os corpos-de-prova com W/B = 1,0 foram capazes de produzir curvas J-R, sem que as trincas apresentassem tunelamento e que os valores médios de trinca (ai e af) medidos conforme a norma (ASTM, 2005), são bastante próximos dos valores obtidos pelo método da variação de flexibilidade elástica. As razões para este fato são discutidas em detalhes. De um modo geral as delaminações, quando existente, não permitem uma correta medição do tamanho de trinca. Ainda, contrário à observação de outros pesquisadores, neste trabalho, foi observado que em vários casos as delaminações induziram fratura instável. / The evaluation of pipes´ structural integrity from laboratories specimens depends on choosing the right specimen geometry that is able to present the conditions of plastic constrain at the crack tip, similar to the one found in the pipes´ operational conditions. The NEMAF Group from SMM, EESC-USP has been performing studies in this area, trying to develop specimen´s geometry that is able to represent this situation, as well as the necessary experimental methodologies to evaluate the fracture toughness of pipes. However, in some cases, the pipe size is a limiting factor in determining the specimen size and geometry. In this work is presented the development and application of specimens SE(T), evaluating the influence of the geometry and dimensions of the specimens on the fracture toughness of API 5L X70 steel, regularly used in the pipes for gas and petroleum transportation. Therefore, the resistance curves to ductile crack propagation, J-R`s curves, using the single specimen methodology, together with the variation of the elastic compliance technique (multiple unloading), measure at the crack mouth (CMOD) that provides both the plastic area under the load x displacement curve and crack size, according to the ASTM E1820-05 standard. The SE(T) specimens with shallow (a/W=0.2) and deep (a/W=0.5) cracks and W/B ratio of 2.5 and 1.0 trying to reduce the amount of plastic deformation and a straight crack front, as well as a dominance of a plane strain state at the crack tip, as recommended by the ASTM E1820-05 standard for other specimens type. From the results it was observed that, independent of the initial a/W, no significant differences were observed in the J-R curves. This fact is verified in both cases, this is, W/B = 2.5 and 1.0. However, in the great majority of CDP\'s with W/B = 2.5, it was obtained an anomalous crack propagation during testing, in other words, they presented an accentuated tunneling due to a high plane tension state near the CDP´s lateral faces, even with the side groove of 20% thickness. The specimens with W/B = 1.0 were capable to produce J-R curves with straight crack fronts, this is, without tunneling, allowing the measurement of medium values of the crack (ai e af) according to the ASTM E1820-05 standard. The reasons for this fact are discussed in details in this work. In general, the split, when present, did not allow a correct crack size measurement. Still, contrary to the other researchers\' observation, in this work, it was observed that in several cases the splits were able to induced unstable fracture.
6

Desenvolvimento de metodologia experimental para aplicação de espécimes SE(T) para avaliação de integridade estrutural em dutos / Development of an experimental methodology for application of SE(T) specimens for pipeline structural integrity evaluation

Roberto Reato Piovatto 01 June 2007 (has links)
Este trabalho apresenta o desenvolvimento e aplicação de espécimes SE(T) em aço API X60 para avaliação de integridade estrutural em dutos condutores de gás e petróleo, o qual consiste na implantação de três técnicas que forneçam as curvas de resistência à propagação dútil de trincas, curvas J-Rs. As metodologias utilizadas foram a da variação da flexibilidade elástica, da queda de potencial elétrico e da normalização linear da carga, nas quais duas análises são verificadas para obtenção da área plástica abaixo da curva de carregamento. A primeira, através da medida do deslocamento da linha de carga e a segunda, pelo deslocamento do extensômetro colocado na boca da trinca. Foram ensaiados corpos de prova SE(T) com trincas rasa (a/W = 0,2) e profunda (a/W = 0,5) e os resultados obtidos permitiram observar a iniciação da propagação por rasgamento dúctil e discutir os limites das metodologias aplicadas. Os resultados mostraram que é possível obter as curvas J-Rs medindo o deslocamento na boca da trinca, podendo-se converter os deslocamentos de CMOD em deslocamentos do LLD. Foi constatada também que a técnica de normalização linear da carga é a que possibilitou o menor tempo de preparação e execução do ensaio, por utilizar apenas a medição do CMOD e não necessitar da realização dos descarregamentos. A variação da flexibilidade elástica é uma técnica rápida e confiável e não sofre alterações devido às delaminações. Já a técnica de queda do potencial elétrico se mostrou a mais consistente para o caso de a/W = 0,5, porém no caso de trincas curtas, a plasticidade desenvolvida na frente da trinca influencia nas medições causando imprecisões. As curvas J-Rs são deslocadas para a esquerda quando o tamanho inicial de trinca é reduzido, isto é, ocorre um aumento na energia de iniciação da propagação, JIC. / This work presents the development and application of SE(T) type specimen for structural integrity evaluation of pipeline steels used for gas and oil transportation, and it consists of the implementation of different techniques to provide the crack growth resistance curves, J-R curves. The methodologies used for crack growth measurement were: the elastic compliance, the electrical potential drop and the linear normalization techniques. Two techniques to provide the plastic area, Apl under the load versus displacement curve were used to evaluate Jpl, one based on the load line displacement, LLD, and the other based on the crack mouth opening displacement, CMOD. SE(T) specimens with two different initial crack size, denominate as shallow crack (a0/W = 0.2) and deep crack (a0/W = 0.5). The obtained results allowed the determination of the ductile tearing initiation point and to discuss the limits of the methodologies applied. It was proved be possible to get J-R curves using only one extensometer to measure the CMOD, which provides both crack size and Apl. The linear normalization technique is the one that provided the lower preparation and testing time, since there is no need of multiples unloading for crack growth measurement. The elastic compliance is a very easy, fast and reliable technique, and it is not sensible to the effect of the occurrence of delaminations, as it was the linear normalization technique. The electrical potential drop technique proved to very consistent for a0/W = 0.5, however in the case of shallow cracks the developed plasticity at the crack tip affected the measurements. The J-R curves were displaced to the left as the initial crack size is reduced, this is, there is an increase in the energy for crack tearing initiation, JIC.
7

Lomová houževnatost kompozitu s Al-matricí a uhlíkovými vlákny / Fracture Toughness of Composite with Al-matrix and Carbon Fibres

Michalička, Jan January 2008 (has links)
Abstract The objective of this study was a values evaluation of fracture toughness of fiber-metal laminates (FML) compounded from carbon fibers in epoxy matrix and aluminium plates of lay-up 6/5. Samples with unidirectional and bidirectional orientation were tested experimentally. In the case of unidirectionally oriented samples an effect of moisture absorption to epoxy matrix on the values of fracture toughness was reviewed. A fracture toughness calculation was realized by COD method firstly. A bigger pop-ins in F – COD diagram as critical moments for "delta"c evaluation were considered; it was determined by 5% tangential line. It was found out, that results of this measurement weren’t in agreement with plane deformation condition and for this the results couldn’t be rated as fracture toughness "delta"Ic. A method of J integral for fracture toughness evaluation was used consequently. A test of elastic compliance changes before J integral calculation by all of samples was performed. Beginning of stable grow of crack was determined by this method. A critical forces Fc from beginnings were established, which were used for calculation of Jc. A functional dependence of elastic compliance on crack opening had specific waved shape before its linear (up to exponential) grow. It was observed in all cases. The critical forces Fc from the end of “wave” preceding the continual grow of compliance were determined. Equations stated in standards for J integral calculation were used, which are for metal materials normally used. Despite this was found out all of results of Jc were in good agreement with plane deformation condition and could be rated as fracture toughness JIc. In this study were found out these pieces of knowledge about fracture toughness of FML CARE: Unidirectional CARE had fracture toughness JIc about 76 kJ/m^2 and the same type but with bigger amount of absorbed moisture had JIc about 4 % higher. In this case negative moisture influences on CARE weren’t found. Bidirectional CARE had fracture toughness JIc about 31 kJ/m^2; it was about 65 % less then in the case of unidirectional CARE

Page generated in 0.0872 seconds