• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 43
  • 24
  • 19
  • 8
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 229
  • 229
  • 229
  • 74
  • 59
  • 54
  • 44
  • 42
  • 39
  • 37
  • 33
  • 33
  • 32
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

A voltage-only method for estimating the location of transmission faults

Vatani, Mehrdad 28 August 2008 (has links)
Not available
22

Evaluation of market-based investment in electricity transmission infrastructure

Parail, Vladimir January 2012 (has links)
No description available.
23

The computor and the analyst : computing and power, 1880s-1960s

Tympas, Aristotelis 12 1900 (has links)
No description available.
24

Mathematical modelling of balanced and unbalanced HVDC power transmission links

Fitton, Colin Robert January 1988 (has links)
In high voltage direct current power transmission, the need to filter the non-sinusoidal current wave forms drawn by the converters from the ac supply has long been acknowledged. Assessment of the harmonic content of these waveforms to the best accuracy possible is a desirable objective to aid filter design. The conventional analytical technique necessitates making simplifying assumptions and produces only approximate results. Such practical considerations as system unbalance cannot be taken into account. The objective of the research was to perform in-depth analyses of hvdc transmission links, by developing a mathematical model which, in addition to perfectly balanced conditions, allows for the following practical operational abnormalities: (i) Unbalanced 3-phase ac supply voltages (ii) Unbalanced converter transformer impedances (iii) Asymmetrical thyristor valve triggering, whilst not making the usual assumptions of infinite dc side inductance and zero ac system impedance. In other words to develop a completely comprehensive mathematical model. The initial approach was to develop the tensor analysis of a six-pulse Graetz bridge supplied first by a star-star, and then by a star-delta connected transformer. A twelve-pulse converter system was then investigated by modelling the series connection of these two arrangements. The technique of diakoptlcs was introduced and combined with the previous tensor analysis to model a complete dc link with a twelve pulse converter at each end of a transmission line. The diakoptic approach enables the full circuit to be torn, for the purpose of the analysis, into the two twelve pulse converters and the dc line. Summary The final stage of the development of the model involved the inclusion of a more sophisticated representation of the ac system impedance and the addition of tuned or damped filters at the ac busbars. To verify the program, computed results from the mathematical model are compared with corresponding experimental results obtained from a laboratory-scale model of a typical hvdc link configuration. Comparisons are also made with conventionally based calculations involving the assumptions included in the computer-based results, in order to investigate the relative accuracy of the computed solution.
25

Improved dynamic stability using FACTS devices with phasor measurement feedback /

Smith, Mark Allen. January 1994 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1994. / Vita. Abstract. Includes bibliographical references (leaves 82-83). Also available via the Internet.
26

A decentralized congestion management approach for the multilateral energy transaction via optimal resource allocation

Liu, Kai, January 2007 (has links)
Thesis (M. Phil.)--University of Hong Kong, 2007. / Title proper from title frame. Also available in printed format.
27

Transmission expansion planning to alleviate congestion in deregulated power markets

Sozer, Sevin, Park, Chan S. January 2006 (has links) (PDF)
Dissertation (Ph.D.)--Auburn University, 2006. / Abstract. Vita. Includes bibliographic references (p.120-125).
28

A self coordinating parallel multi-PI control scheme for an HVDC transmission system to accommodate a weak AC system

Meah, Kala. January 2007 (has links)
Thesis (Ph.D.)--University of Wyoming, 2007. / Title from PDF title page (viewed on June 22, 2009). Includes bibliographical references (p. 120-127).
29

Power system transmission enhancement through storage /

Zhang, Xiaodong, January 1992 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1992. / Vita. Abstract. Includes bibliographical references (leaves 47-49). Also available via the Internet.
30

Modeling and control of the unified power flow controller (UPFC)

Hasanovic, Azra. January 2000 (has links)
Thesis (M.S.)--West Virginia University, 2000. / Title from document title page. Document formatted into pages; contains viii, 78 p. : ill. Includes abstract. Includes bibliographical references (p. 61-63).

Page generated in 0.1138 seconds