• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Properties and durability of slag based cement concrete in the Mediterranean environment

Muntasser, Tarek Ziad January 2002 (has links)
No description available.
2

Evaluating Alternative Technologies And Monitoring Methods For Water Quality In A Field Setting; Research On Effects On Phosphorous And Solids Removal From Cheese Factory Wash Water And Stormwater Runoff Treatment

Allen, Dana J. 01 January 2017 (has links)
Lake Champlain is a major economic driver for Vermont's tourism economy, as well as a primary source of drinking water for many of the state's residents but nutrient pollution represents a potential threat to ecosystem health and economic well-being. From December 2011 to December 2012 a field trial of an EAF steel slag filter was assessed for its feasibility in treating wastewater originating from Swan Valley Cheese (SVC), in Swanton, VT. The study focuses on a period of the filter's operation from May 4 to October 10, 2012. The plant generates approximately 20,000 gallons per day of high P concentration wash water which is treated in an open aerated lagoon. The filter treated effluent from this lagoon. The major goals of this research were to conduct a field trial of an EAF steel slag filter to evaluate its effect on total P (TP), dissolved reactive P (DRP), and total suspended solids (TSS). Research was also conducted on pH reduction for filter effluent. Results indicate that the filter removed 95.83% of TP, 96.65% of DRP, and 52.25% of TSS. Average pH effluent was measured at 10.12 ±1.55. Additionally, a field study was conducted on sampling two unlined bioretention systems treating urban stormwater runoff. Methods used are presented and methodological considerations for future studies are presented to guide researchers in more effective and efficient methods for obtaining influent and effluent samples from bioretention systems that are not necessarily designed for sampling.

Page generated in 0.176 seconds