• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

On the Fabrication of Microparticles Using Electrohydrodynamic Atomization Method

Kuang, Lim Liang, Wang, Chi-Hwa, Smith, Kenneth A. 01 1900 (has links)
A new approach for the control of the size of particles fabricated using the Electrohydrodynamic Atomization (EHDA) method is being developed. In short, the EHDA process produces solution droplets in a controlled manner, and as the solvent evaporates from the surface of the droplets, polymeric particles are formed. By varying the voltage applied, the size of the droplets can be changed, and consequently, the size of the particles can also be controlled. By using both a nozzle electrode and a ring electrode placed axisymmetrically and slightly above the nozzle electrode, we are able to produce a Single Taylor Cone Single Jet for a wide range of voltages, contrary to just using a single nozzle electrode where the range of permissible voltage for the creation of the Single Taylor Cone Single Jet is usually very small. Phase Doppler Particle Analyzer (PDPA) test results have shown that the droplet size increases with increasing voltage applied. This trend is predicted by the electrohydrodynamic theory of the Single Taylor Cone Single Jet based on a perfect dielectric fluid model. Particles fabricated using different voltages do not show much change in the particles size, and this may be attributed to the solvent evaporation process. Nevertheless, these preliminary results do show that this method has the potential of providing us with a way of fine controlling the particles size using relatively simple method with trends predictable by existing theories. / Singapore-MIT Alliance (SMA)
2

Electrospray for pulmonary drug delivery

Lajhar, Fathi January 2018 (has links)
Drug administration through the pulmonary route is an ancient technique that evolved from inhaling the smoke of certain leaves as a medicine. The optimum droplet diameter for the pulmonary system deposition has been identified to be in the range from 2 to 3.5 μm, with potential deposition rates of up to 80% of this size range. Currently, the most used aerosol generator methods are the pressurized metered dose inhalers. However, they generally exhibit low deposition efficiency with less than 20 % of the spray reaching the target area of the lungs as most of the drug deposited in the upper airways. This is for the most part due to the droplet size polydispersity that is inherent in these systems. The droplets of the biggest diameter will deposit in the upper airways, and then the deposited medicine will be swallowed and absorbed in the gastrointestinal tract. This can produce adverse medical side effects. Electrospray (ES) or electrohydrodynamic atomization (EHDA) is a promising atomization process due to its ability to produce a spray with monodisperse droplet size. The current study will investigate the feasibility of using electrospray in a pulmonary drug delivery system. Assessments, selection and characterization of suitable biocompatible solvents that can be used as a lung obstruction relief drug were carried out. Tests to identify the electrospray setup necessary to produce droplet sizes in the appropriate range for deposition in the lungs were carried out. The study found that both stable and pulsating cone jet modes can produce the required droplet size and the pulsating mode can produce at least four times higher flow than stable cone jet mode. A low-cost image analysis technique developed for this work gave satisfactory results that could be compared to droplet size scaling laws from the literature. However, it proved to be relatively time consuming and further automation of this technique would make it more suitable for large-scale studies. The image analysis results show a correlation between the cone length, cone angle and the applied voltage. The droplet scaling laws discrepancies such as the solution flow rate exponent and the constant that is used by some scaling laws may be attributed to the droplet evaporation time which is quite short for the water/ ethanol solutions. The emitter diameter and the conductivity effect on the I(Q) power law and the sensitivity of the onset voltage (Vonset) to the liquid flow rate (Q), were demonstrated for solutions of triethylene-glycol (TEG), and for an ethanol-water mixture solution.

Page generated in 0.1133 seconds