• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 29
  • 29
  • 6
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Nuclear lifetime measurement of the 344-KeV level of 152Gd

King, John J. 03 June 2011 (has links)
A delayed-coincidence timing spectrometer system was used to experimentally measure the lifetime of the 344-keV level of 152 64Gd by means of the self comparison technique. A major objective of the study was to determine the effectiveness of a NaI(Tl)-plastic detector assembly for energy spectrum reconstruction when measuring the lifetime of a level in a complex nuclear decay scheme. The experimentally measured mean life was 38 ± 5 psec. This result does not agree with two previously reported values of 76 psec. It was concluded that gamma-ray energy misidentification was primarily responsible for the disagreement. Correction factors would have to be applied to the experimental data is such a system is to be effective in a nuclear decay scheme study which involves many gamma rays.Ball State UniversityMuncie, IN 47306
12

Algorithms for numerical modeling and inversion of multi-phase fluid flow and electromagnetic measurements

Alpak, Faruk Omer 28 August 2008 (has links)
Not available / text
13

Electromagnetic properties of high specific surface minerals

Klein, Katherine 08 1900 (has links)
No description available.
14

The influence of printed circuit board design on TEM cell measurements

Kasturi, Vijay, January 2007 (has links) (PDF)
Thesis (M.S.)--University of Missouri--Rolla, 2007. / Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed March 24, 2008) Includes bibliographical references (p. 105-106).
15

Quantifying the effects of transmitter-receiver geometry variations on the capabilities of airborne electromagnetic survey systems to detect targets of high conductance /

Hefford, Shane W. January 1900 (has links)
Thesis (M.Sc.) - Carleton University, 2006. / Includes bibliographical references (p. 128-134). Also available in electronic format on the Internet.
16

Investigating cost-effective EMC methods

Wiid, P. Gideon 12 1900 (has links)
Thesis (MScEng (Electrical and Electronic Engineering))--University of Stellenbosch, 2005. / Due to the expensive nature of high frequency measurements in the EMC (Electromagnetic Compatability) field, more affordable methods of measurement instrumentation and environments are investigated. Different calibration methods for an Automatic Network Analyser (ANA) are evaluated against each other to determine the most cost-effective method of calibration. The mathematics for all the calibration methods are used in MATLAB programs which perform the error-calculation and correction which is usually done by the ANA software. These programs can be used to develop a simplified homebuilt ANA at reduced cost. The MATLAB program calibrations are compared to actual ANA calibrations to determine accuracy. Different measurement environments are considered as well to decide on a best compromise between cost and accuracy. To achieve this a reverberation chamber was built in which measurements were done and compared to measurements done on an Open Area Test Site. The Device Under Test was a standard radiator constructed specifically for such measurements. The development of both the radiator and the reverberation chamber are discussed and all the measurement results are considered in this thesis.
17

Characterizing magnetic noise of AUV for use in towed magnetometer study of internal waves

Unknown Date (has links)
As part of a project to study internal waves, FAU plans to utilize an AUV to tow a magnetometer to study electromagnetic signatures from internal waves. This research is focused on the electromagnetic noise issues related to using an AUV to tow the magnetic sensor package. There are active sources of electromagnetic noise caused by an AUV that are present in addition to those induced by the Earth's magnetic field and permanent magnets. To characterize the magnetic noise associated with the AUV magnetometer tow system, the various active source elements were identified, the orientation sensitivity of the sensors being used was determined, and the magnetic anomaly of a similar AUV which may be eventually be used in a magnetic sensing arrangement was measured. The results are used to show the proposed sensing arrangement will likely not achieve the necessary sensitivity to measure subtle internal wave signals. / by Dylan Tilley. / Vita. / Thesis (M.S.C.S.)--Florida Atlantic University, 2012. / Includes bibliography. / Electronic reproduction. Boca Raton, Fla., 2012. Mode of access: World Wide Web.
18

Simulating the dynamic interaction of an AUV and towed magnetometer

Unknown Date (has links)
A magnetometer with a sensitivity of 0.01nT will be towed through the thermocline by a 2.87 meter long, 0.533 meter diameter autonomous underwater vehicle (AUV) to measure the magnetic fluctuations generated by oceanic internal waves. At this point, no research has been found that suggests towed magnetometer measurements have been done using an AUV. Simulations of the AUV, tow cable, and towfish are performed to provide an understanding of the effects of changing different input parameters, such as towing speed (0.5-2m/s), cable length (5-15m), vehicle trajectory (circle and vertical zig zag maneuvers), and current (0.25-1.25m/s). The AUV-cabletowfish system and equations of motion needed for the simulations are described herein. Results show that a 5m tow cable provides better towfish maneuvering than the longer cable lengths. High towfish pitch angle is decreased by decreasing the distance between CG and CB. Surface currents speed of 0.25m/s change the AUV and towfish circle maneuver to a spiral trajectory, while 1.25m/s current speed cause a zig zag trajectory. / by Lea Gabrielle Miller. / Thesis (M.S.C.S.)--Florida Atlantic University, 2011. / Includes bibliography. / Electronic reproduction. Boca Raton, Fla., 2011. Mode of access: World Wide Web.
19

Investigation of an electromagnetic underwater communications system

White, Douglas Wescott January 1975 (has links)
Thesis. 1975. B.S.--Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science. / Bibliography: leaf 36. / by Douglas W. White. / B.S.
20

Pore-scale petrophysical models for the simulation and combined interpretation of nuclear magnetic resonance and wide-band electromagnetic measurements of saturated rocks

Toumelin, Emmanuel 28 August 2008 (has links)
Not available / text

Page generated in 0.1484 seconds