Spelling suggestions: "subject:"electrophysics"" "subject:"eletrophysics""
21 |
Electrical and Optical Charactristics of InP Nanowire PhotodetectorsMALEKRAH, MEHDI January 2010 (has links)
<p>In this project Fourier Transform Infrared Spectroscopy is used to investigate a new kind of photodiode that is based on nanowires. The photo current and I-V curves for different temperatures, different applied biases, in darkness and illumination condition have been studied. The experiment was conducted in the temperature range from 78 K (-195ºC) to 300 K (27ºC). These photo diodes are designed to work on NIR wavelengths. The results show some excellent properties, such as high break down voltage, and that is an important advantage for photo detectors, low and constant reverse saturation current (Is). The results show some defects, most of them come from fabrication. The design of the sample is also discussed.</p>
|
22 |
CONTRIBUTION TO QUANTITATIVE MICROWAVE IMAGING TECHNIQUES FOR BIOMEDICAL APPLICATIONSHenriksson, Tommy January 2009 (has links)
This dissertation presents a contribution to quantitative microwave imaging for breast tumor detection. The study made in the frame of a joint supervision Ph.D. thesis between University Paris-SUD 11 (France) and Mälardalen University (Sweden), has been conducted through two experimental microwave imaging setups, the existing 2.45 GHz planar camera (France) and the multi-frequency flexible robotic system, (Sweden), under development. In this context a 2D scalar flexible numerical tool based on a Newton-Kantorovich (NK) scheme, has been developed. Quantitative microwave imaging is a three dimensional vectorial nonlinear inverse scattering problem, where the complex permittivity of an object is reconstructed from the measured scattered field, produced by the object. The NK scheme is used in order to deal with the nonlinearity and the ill-posed nature of this problem. A TM polarization and a two dimensional medium configuration have been considered in order to avoid its vectorial aspect. The solution is found iteratively by minimizing the square norm of the error with respect to the scattered field data. Consequently, the convergence of such iterative process requires, at least two conditions. First, an efficient calibration of the experimental system has to be associated to the minimization of model errors. Second, the mean square difference of the scattered field introduced by the presence of the tumor has to be large enough, according to the sensitivity of the imaging system. The existing planar camera associated to a flexible 2D scalar NK code, are considered as an experimental platform for quantitative breast imaging. A preliminary numerical study shows that the multi-view planar system is quite efficient for realistic breast tumor phantoms, according to its characteristics (frequency, planar geometry and water as a coupling medium), as long as realistic noisy data are considered. Furthermore, a multi-incidence planar system, more appropriate in term of antenna-array arrangement, is proposed and its concept is numerically validated. On the other hand, an experimental work which includes a new fluid-mixture for the realization of a narrow band cylindrical breast phantom, a deep investigation in the calibration process and model error minimization, is presented. This conducts to the first quantitative reconstruction of a realistic breast phantom by using multi-view data from the planar camera. Next, both the qualitative and quantitative reconstruction of 3D inclusions into the cylindrical breast phantom, by using data from all the retina, are shown and discussed. Finally, the extended work towards the flexible robotic system is presented. / A dissertation prepared through an international convention for a joint supervision thesis with Université Paris-SUD 11, France / Microwaves in biomedicine
|
23 |
Electrical and Optical Charactristics of InP Nanowire PhotodetectorsMALEKRAH, MEHDI January 2010 (has links)
In this project Fourier Transform Infrared Spectroscopy is used to investigate a new kind of photodiode that is based on nanowires. The photo current and I-V curves for different temperatures, different applied biases, in darkness and illumination condition have been studied. The experiment was conducted in the temperature range from 78 K (-195ºC) to 300 K (27ºC). These photo diodes are designed to work on NIR wavelengths. The results show some excellent properties, such as high break down voltage, and that is an important advantage for photo detectors, low and constant reverse saturation current (Is). The results show some defects, most of them come from fabrication. The design of the sample is also discussed.
|
24 |
Electrical and Optical Characteristics of InP Nanowires based p-i-n PhotodetectorsAhmed, Rizwan, Abbas, Shahid January 2010 (has links)
Photodetectors are a kind of semiconductor devices that convert incoming light to an electrical signal. Photodetectors are classified based on their different structure, fabrication technology, applications and different sensitivity. Infrared photodetectors are widely used in many applications such as night vision, thermal cameras, remote temperature sensing, and medical diagnosis etc. All detectors have material inside that is sensitive to incoming light. It will absorb the photons and, if the incoming photons have enough energy, electrons will be excited to higher energy levels and if these electrons are free to move, under the effect of an external electric field, a photocurrent is generated. In this project Fourier Transform Infrared (FT-IR) Spectroscopy is used to investigate a new kind of photodiodes that are based on self-assembled semiconductor nanowires (NWs) which are grown directly on the substrate without any epi-layer. The spectrally resolved photocurrent (at different applied biases) and IV curves (in darkness and illumination) for different temperatures have been studied respectively. Polarization effects (at low and high Temperatures) have been investigated. The experiments are conducted for different samples with high concentration of NWs as well as with lower concentration of NWs in the temperature range from 78 K (-195ºC) to 300 (27ºC). These photodiodes are designed to work in near infrared (NIR) spectral range. The results show that the NW photodetectors indeed are promising devices with fairly high break down voltage, change of photocurrent spectra with polarized light, low and constant reverse saturation current (Is). The impact of different polarized light on photocurrent spectra has been investigated and an attempt has been made to clarify the observed double peak of InP photocurrent spectrum. Our investigations also include a comparison to a conventional planar InP p-i-n photodetector.
|
25 |
Development of PDI plates for Industrial ApplicationsSiddiqui, Muhammad Saad, Iqbal, Tahseen January 2010 (has links)
The aim of this Master’s Degree thesis project is to design and develop point diffraction interferometer plates. In this project the PDI plates are re-designed, changing the design which was used in previous projects in Halmstad University. The transparency of PDI plates can be controlled by coating them with NiCr film. Firstly, four plates with coating of different thickness of NiCr were developed. The relationship between transmittance and the thickness of NiCr was established by testing these plates for transmittance and reflectance with the help of a laser and an optical power meter. The absorption coefficient of clear substrates and reflection of light is also taken into account to achieve the correct results. The parameters like the diameter of semi-transparent area around the pinholes and the size of pinholes is chosen after fully understanding its application. The lay-out and description of design is also included in the report.
|
Page generated in 0.0532 seconds