• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 3
  • 1
  • Tagged with
  • 12
  • 12
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Recuperação de cobre de rejeitos de galvanoplastia utilizando resinas de troca iônica / Recovery of copper of sludges of electroplating using ion exchange resins

Adriana Azedias Andrade Evaristo 14 February 2012 (has links)
Neste estudo, a sorção e recuperação de íons metálicos de resíduos sólidos industriais provenientes de uma indústria de galvanoplastia situada no Rio de Janeiro (Brasil) foram investigadas através da utilização de duas resinas comerciais de troca iônica: Lewatit VPOC 1800 (fortemente ácida, tipo gel) e Lewatit VPOC 1960 (fortemente básica, tipo gel), produzidas pela Lanxess-Bayer Chemicals. As características físico-quimicas das resinas e do lodo galvânico foram determinadas. Os estudos de sorção das resinas foram conduzidos em batelada e em coluna. Baseado nesses estudos, os parâmetros de sorção e das curvas de ruptura foram determinados. Os estudos de equilíbrio e cinética de sorção também foram realizados. O resíduo de galvanoplastia era composto pelos metais: Cu2+, Fe3+, Al3+, Ni2+ e Cr3+. A capacidade de sorção qe das resinas Lewatit VPOC 1800 variou entre 0,1-1,9 mg g-1 para Cu2+, 0,01-0,6 mg g-1 para Fe3+ e 0,2-0,4 mg g-1 para Al3+. Enquanto que para a resina Lewatit VPOC 1960, os valores de qe variou entre 0,01-0,4 mg g-1 para Cu2+ e 0,01 0,2 mg g-1 para Fe3+ dependendo da concentração do metal e do tempo de contato. A capacidade de sorção para a resina Lewatit VPOC 1960 foi restrita para íons Cu2+ e Fe3+ os quais formam complexos aniônicos com íons Cl-. O modelo de Freundlich foi o mais adequado para descrever o equilíbrio de troca iônica de ambas as resinas. Já em relação ao mecanismo de sorção, o modelo pseudo-segunda ordem tipo 1 foi o mais aplicável. O ponto de ruptura das resinas Lewatit VPOC 1800 e Lewatit VPOC 1960 em relação aos íons Cu2+ocorreu quando passou através da coluna, 1860 cm3 e 2220 cm3 de solução de resíduo sólido respectivamente (20 g de resina, 100 mg L-1 de íons Cu2+, vazão de 60 cm3 min-1). Os íons metálicos Cu2+, Fe3+, Al3+, foram dessorvidos em alta proporção da resina Lewatit VPOC 1800 passando pela coluna solução aquosa de H2SO4 2,4 mol L-1. Já os metais Cu2+ e Fe3+ foram eluídos da resina Lewatit VPOC 1960 com solução aquosa de HCl 2,0 mol L-1. A recuperação seletiva de Cu2+ não foi alcançada porque Cu2+ e Fe3+ precipitam na mesma faixa de pH / In the present study, the sorption and recovery of metal ions from industrial solid residues proceeding from galvanoplasty industry (Rio de Janeiro, Brazil) was investigated by using two commercial ion exchange resins Lewatit VPOC 1800 (strong acid, gel type) and Lewatit VPOC 1960 (strong basic, gel type) produced by Lanxess - Bayer Chemicals. The physical-chemical characteristics of the resins and galvanic sludge were determined. The studies of sorption of the resins were conduced under batch and column conditions. Based on these studies the sorption parameters and the breakthrough curves for both resins were determined. Studies of equilibrium and kinetic of the sorption were also performed. The electroplating residue were composed of the metals Cu2+, Fe3+, Al3+, Ni2+ and Cr3+. The sorption capacity qe of the resin Lewatit VPOC1800 varied between 0.1-1.9 mg g-1 to Cu2+, 0.01-0.6 mg g-1 to Fe3+ and 0.2-0.4 mg g-1 to Al3+. While for the resin Lewatit VPOC1960 the values of qe varied between 0.01-0.4 mg g-1 to Cu2+ and 0.01-0.2 mg g-1 to Fe3+ depending of the metal concentration and contact time. The sorption capacity for Lewatit VPOC1960 was restricted to ions Cu2+ and Fe3+ that to form anionic complexes with chloride. The Freudlich model was more adequate to describe the ion exchange equilibrium for both resins and the sorption mechanism was compliant to the kinetic model of pseudo second order type 1. The breakpoint to Cu2+ occurred after passing 1860 cm3 and 2220 cm3 of residue solution through the resins Lewatit VPOC1800 and Lewatit VPOC1960, respectively (20 g of the resin, 100 ppm of Cu2+, flow rate of 60 cm3 min-1). The metals Cu2+, Fe3+ and Al3+ were desorbed on high proportion of the Lewatit VPOC1800 through passing a aqueous solution H2SO4 2.4 mol L-1. Already the metals Cu2+ and Fe3+ were eluted to Lewatit VPOC1960 with HCl aqueous solution 2.0 mol L-1. The selective recuperation of the Cu2+ was not reach because the Cu2+ and Fe3+ precipitated on similar pH
12

Estudo da eficiência do processo de coagulação/floculação e do processo combinado de coagulação/floculação/adsorção para tratamento de águas residuárias de galvanoplastia utilizando Moringa oleífera / Study on the efficiency of the process of coagulation/flocculation and the combined process of coagulation/flocculation/adsorption for treatment of electroplating wastewater using Moringa oleifera

Alves, Alvaro Cesar Dias 24 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:07:59Z (GMT). No. of bitstreams: 1 Alvaro Cesar Dias Alves.pdf: 1860253 bytes, checksum: fce25e3199fa4e1f2d24f3500c996153 (MD5) Previous issue date: 2012-02-24 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This study aimed to evaluate the efficiency of the process of coagulation/ flocculation and coagulation/flocculation/adsorption combined process for treatment of liquid effluent from the electroplanting industry. Were used the moringa seed as a natural coagulant agent and moringa bark and string bean as adsorbents. Were evaluated the parameters COD, color, pH, turbidity and the concentration of metal ions Cr, Zn, Cu and Ni. In the stage of coagulation/ flocculation were used several concentrations of moringa in salt solution of NaCl 1 M and 0.1M. In the stage of the combined adsorbents were used moringa bark and string beans to determine which of the adsorbent had a better removal efficiency of metals. Tests were also conducted with different ranges of mass for the best adsorbent and variation of pH of the studied effluent. Tests of coagulation/flocculation showed good removal efficiency for the parameters COD, Color, Turbidity and the metals Cr, Zn, Cu and Ni using MO seed in salt solution 1M, these values being 90.49%, 78.34%, 95.13%, 25.29%, 84.30%, 51.11% and 24.74% respectively. In the tests of coagulation/flocculation/adsorption the maximum removal efficiencies were 91.41% for COD, 90.77% for color, 95.31% for Turbidity, 58.36% for Cr, 98.36% for Zn, 97,58% for Cu and 99.11% for Ni. The research showed that after the combined process the electroplanting effluent did not present the necessary characteristics for the released in to water bodies due to the high remaining concentration of Cr (1907.4 mg/L), Color (860 PtCo/L) and COD (330 mg/L). The research for the treatment process demonstrated great effectiveness for most parameters analyzed, however, its necessary to study complementary technologies for this type of treatment effluent in order to achieve an effluent within the release standards into the water bodies. / Este trabalho teve como objetivo avaliar a eficiência do processo de coagulação/floculação e do processo combinado de coagulação/floculação/adsorção para tratamento de efluente liquido da indústria galvânica. Foi utilizada a semente de moringa como coagulante natural e a casca e a vagem de moringa como adsorventes. Foram avaliados os parâmetros DQO, Cor, pH, Turbidez e a concentração dos íons metálicos Cr, Zn, Cu e Ni. Na etapa de coagulação/floculação foram utilizadas várias concentrações de moringa em solução salina de NaCl 1M e 0,1M. Na etapa do processo combinado foram utilizados os adsorventes casca e vagem de moringa para determinação do adsorvente com melhor eficiência de remoção dos metais. Também foram realizados ensaios com variação de massa do melhor adsorvente e variação do pH do efluente estudado. Os ensaios de coagulação/floculação mostraram boa eficiência de remoção dos parâmetros DQO, Cor, Turbidez e dos metais Cr, Zn, Cu e Ni utilizando semente de MO em solução salina 1M, sendo esses valores 90,49%, 78,34%, 95,13%, 25,29%, 84,30%, 51,11% e 24,74%, respectivamente. Nos ensaios de coagulação/floculação/adsorção as eficiências máximas de remoção foram 91,41% para DQO, 90,77% para Cor, 95,31% para Turbidez, 58,36% para Cr, 98,36% para Zn, 97,58% para Cu e 99,11% para Ni. Verificou-se que após o processo combinado o efluente galvânico não apresentou as características necessárias para lançamento em corpos hídricos em função da alta concentração remanescente de Cr (1907,4 mg/L), Cor (860 PtCo/L) e DQO (330 mg/L). Verificou-se que os processos de tratamento estudados demonstraram eficiência para a maioria dos parâmetros analisados, entretanto, fazem-se necessários estudar tecnologias complementares para o tratamento deste tipo de efluente com intuito de obter um efluente dentro dos padrões de lançamentos em corpos receptores.

Page generated in 0.1018 seconds