• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 23
  • 23
  • 23
  • 23
  • 21
  • 12
  • 10
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Determinação de alfahidroxiácidos por eletroforese capilar e cromatografia líquida de alta eficiência em produtos cosméticos / Determination of alpha hydroxy acids by capillary electrophoresis and high performance liquid chromatography in cosmetic products

Elizângela Abreu Dutra 28 April 2005 (has links)
Nos últimos anos vários produtos cosméticos contendo alfahidroxiácidos (AHAs) têm sido desenvolvidos e estão disponíveis no comércio, causando uma grande revolução em relação ao tratamento da pele fotoenvelhecida. Com o aumento da produção desses produtos, torna-se necessário o desenvolvimento e validação de novas metodologias analíticas para determinar os AHAs contidos em preparações cosméticas, tanto para o controle da qualidade do produto como para a segurança do consumidor. Nesta pesquisa os AHAs tartárico, glicólico, lático e mandélico foram analisados simultaneamente por eletroforese capilar (CE) e cromatografia líquida de alta eficiência (CLAE). Os métodos foram validados avaliando-se os parâmetros de linearidade, limite de quantificação, precisão e exatidão. A separação e determinação quantitativa por CE dos ácidos glicólico, tartárico e lático foram realizadas empregando-se um capilar de sílica fundida com comprimento total de 57 cm e 50 cm de comprimento até o detector, 75 &#181;m d.i.; eletrólito constituído de hidrogenoftalato de potássio 10 mmol.L-1, CTAB 0,5 mmol.L-1, pH 4,1; tensão aplicada de -20 kV com detecção UV indireta a 254 nm; temperatura de 35°C. A separação e determinação quantitativa dos ácidos glicólico, tartárico e lático por CLAE foram realizadas empregando-se coluna Sinergy Hydro RP-18 Phenomenex&#174;, fase móvel constituída de solução fosfato de amônio 15 mmol.L-1, tetrabutilamônio 3 mmol.L-1, pH 2,0, vazão 0,7 mL/min e detecção no UV 220 nm. Para determinação do ácido mandélico por CLAE, foi empregada coluna RP-18 Lichrospher&#174; Merck, fase móvel constituída de solução de fosfato de amônio 15 mmol.L-1 / acetonitrila (80/20, v/v) , pH 2,5, vazão 1,0 mL/min. Os métodos propostos apresentaram boa linearidade com coeficiente de correlação (r) > 0,9999, boa especificidade, repetibilidade aceitável com desvio padrão relativo (RSD) < 1% para determinação nas amostras comerciais e exatidão com percentual de recuperação entre 99 e 101%. Os métodos propostos podem ser aplicados para determinação e quantificação de AHAs contidos em produtos cosméticos em curto espaço de tempo. / In recent years many new cosmetic products containing alpha-hydroxy acids (AHAs) have been developed and are commercially available, causing a great revolution to the treatment of the photoaging. With the increase of the production of these products, there is a need of development and validation of analytical methods for quantitative determination of AHAs, both for quality control purposes and to avoid excessive concentrations that could cause consumers undesirable side-effects. In this research, AHAs like tartaric, glycolic, lactic and mandelic acids were analyzed simultaneously using capillary electrophoresis (CE) and high performance liquid chromatography (HPLC). The methods were validated evaluating the parameters of linearity, limit of quantitation, precision and accuracy. The separation and determination for tartaric, glycolic and lactic acids using CE involved an uncoated silica capillary with 75 &#181;m i.d. and total length of 57 cm, 50 cm to the detector, with a solution containing 10 mmol.L-1 potassium phthalate as the background electrolyte and 0.5 mmol.L-1 cetyltrimethylammonium bromide as the electroosmotic flow modifier, pH 4.1, the applied voltage was -20 kV with indirect detection at 254 nm, the operating temperature was 35°C. The separation and determination for tartaric, glycolic and lactic acids using HPLC involved an Sinergy Hydro RP-18 Phenomenex&#174; column, a mobile phase constituted of 15 mmol.L-1 ammonium dihydrogen phosphate and 3 mmol.L-1 tetrabutylammmonium bromide, pH 2.0, a flow-rate of 0.7 mL.min-1 and UV detection at 220 nm. For the determination of the mandelic acid using HPLC involved an LiChrospher&#174; 100 RP-18 Merck column, a mobile phase constituted of 15 mmol.L-1 ammonium dihydrogen phosphate / acetonitrila (80/20, v/v) pH 2.5, a flow-rate of 1.0 mL.min-1 and UV detection at 220 nm. The proposed methods presented good linearity with correlation coefficients more than 0.9999, good specificity, acceptable repeatability, with relative standard deviation (RSD) were less than 1% for commercial samples determination, and recoveries were between 99% and 101 %. The proposed methods can be readily applied to commercially available cosmetic product for quantitative analysis with speed.
22

Avaliação da potência do hormônio da paratireóide humano recombinante por bioensaio, métodos cromatográficos e eletroforético / Recombinant human parathyroid hormone potency evaluation by bioassay, chromatographic and electrophoretic methods

Maldaner, Fernanda Pavani Stamm 24 May 2017 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul - FAPERGS / The human parathyroid hormone (hPTH) is a polypeptide secreted by the parathyroid glands that is essential for the maintenance of the calcium ion homeostasis in the blood. The recombinant DNA technology has enabled the expression of hPTH gene in Escherichia coli, and thus the large-scale production of recombinant human parathyroid hormone (rhPTH 1-34), teriparatide, which contain the active amino-terminal fragment of the full length hPTH. The rhPTH is clinically used to treat osteoporosis at high risk of fractures in postmenopausal women, men with osteoporosis primary or hypogonadal and adults with glucocorticoid-induced osteoporosis (GIO). Cappilary zone electrophoresis (CZE) method was developed and validated for the assessment of rhPTH in biopharmaceutical formulations. The analysis for CZE method was performed on a fused-silica capillary (effective length, 40 cm; 50 μm i.d.), using electrolyte solution consisted of 50 mM dihydrogen phosphate solution at pH 3.0. The capillary was maintained at 25º C, the applied voltage was 20 kV. Injections were performed using a pressure mode at 50 mbar for 45 s, with detection by photodiode array detector set at 200 nm. Separation was obtained with a migration time of 5.3 min, and was linear over the concentration range of 0.25-250 μg mL-1 (r2 = 0.9992). The limits of detection and quantitation were 0.12 and 0.40 μg/mL, respectively. Specificity and stability-indicating capability were established in degradation studies, which also showed that there was no interference of the excipients. The accuracy was 100.28% with bias lower than 0.85%. Moreover, the in vitro cytotoxicity test of acidic, photolytic and thermal degradated forms showed significant differences (p<0.05) compared to intact molecule. The cell proliferation and alkaline phosphatase activity bioassays in UMR-106 cells were developed and applied to assess the biological activity of rhPTH in biopharmaceutical formulations The results of content/potency were correlated to those of the validated reversed-phase liquid chromatography (RP-LC), size-exclusion liquid chromatography (SE-LC) and CZE methods, showing significant correlation (p> 0.05) Thus, the application of the validated physico-chemical methods together with in vitro bioassays, was suggested to improve quality control of rhPTH biotechnology-derived product and to support studies of biosimilars. / O hormônio da paratireóide humano (hPTH) é um polipeptídeo produzido e secretado pelas glândulas paratireóides, e é fundamental para a manutenção da homeostase dos íons cálcio no sangue. A tecnologia do DNA recombinante possibilitou a expressão do gene do hPTH em Escherichia coli, e a produção em grande escala do hormônio da paratireóide humano recombinante (rhPTH 1-34), também denominado Teriparatida, o qual apresenta a sequência de aminoácidos responsável pela porção biologicamente ativa do paratôrmonio natural. O rhPTH é clinicamente indicado para o tratamento da osteoporose de alto risco de fraturas em mulheres pós-menopausa, de homens com osteoporose primária ou hipogonadal, e da osteoporose associada à terapia sistêmica com glicocorticóides. Neste trabalho foi desenvolvido e validado método por eletroforese capilar de zona (ECZ) para a avaliação de rhPTH em produtos biofarmacêuticos. No método por ECZ, utilizou-se capilar de sílica fundida (40 cm de comprimento efetivo x 50 μm d.i.) e solução eletrolítica composta de fosfato de sódio dihidrogenado 50 mM, pH 3,0. O capilar foi mantido a temperatura de 25ºC, e a tensão aplicada foi de 20 kV. O tempo de injeção foi de 45 s, com pressão de 50 mBar, e detecção por arranjo de diodos (DAD), em 200 nm. A separação eletroforética foi obtida com tempo de migração de 5,3 min, sendo linear na faixa de concentração de 0,25-250 μg/mL (r2 = 0,9992). Os limites de detecção e quantificação foram de 0,12 e 0,40 μg/mL, respectivamente. A especificidade foi avaliada através de análises com os excipientes da formulação biofarmacêutica e estudos de degradação, demonstrando a seletividade do método. A exatidão foi 100,28% com bias inferior a 0,85%. Além disso, realizou-se o teste de citotoxicidade in vitro das formas degradadas, apresentando, para as amostras submetidas às condições ácida, fotolítica e térmica, diferença significativa (p< 0,05) em relação à molécula íntegra. Os bioensaios de proliferação celular e da atividade da fosfatase alcalina em células UMR-106 foram desenvolvidos e aplicados para avaliação da atividade biológica de rhPTH em formulações biofarmacêuticas. Os resultados de teor/potência foram correlacionados com os métodos já validados por cromatografia líquida em fase reversa (CL-FR), cromatografia líquida por exclusão molecular (CL-EM) e ECZ, apresentando correlação significativa (p> 0,05). Assim, sugere-se que o métodos físico-químicos validados sejam aplicados paralelamente aos bioensaios in vitro para aprimorar o controle da qualidade do produto biotecnológico de rhPTH, e para avaliação da biossimilaridade de rhPTH.
23

VALIDAÇÃO DE MÉTODO POR ELETROFORESE CAPILAR PARA AVALIAÇÃO DE FILGRASTIMA. ESTUDOS DE CORRELAÇÃO ENTRE MÉTODOS FÍSICO-QUÍMICOS E BIOLÓGICO. / VALIDATION OF CAPILLARY ELECTROPHORESIS METHOD FOR THE EVALUATION OF FILGRASTIM. CORRELATION STUDY BETWEEN PHYSICO-CHEMICAL AND BIOLOGICAL METHODS.

D'avila, Felipe Bianchini 24 September 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The granulocyte-colony stimulating factor (G-CSF) is a hematopoietic cytokine that stimulates and regulates the proliferation and differentiation of neutrophils precursors cells of the bone marrow. The recombinant hormone (rhG-CSF) non-glycosylated, filgrastim, is used to treat the neutropenia induced by chemotherapy and bone marrow transplantation. The hydrophobic protein is a 175 aminoacids chain which contains an extra methionine at its N-terminus, and molecular weight of 18.8 kDa. In the present study, a capillary zone electrophoresis (CZE) method was developed and validated for the analysis of filgrastim in pharmaceuticals. The analyses were performed on a fused-silica capillary (75 μm i.d.; effective length, 72 cm) and background electrolyte consisted of 50 mM sodium tetraborate solution at pH 9.0. The capillary temperature was maintained at 15 °C and the applied voltage was 15 kV. The injection was performed using the hydrodynamic mode at 50 mbar for 6 s, with detection at 195 nm using a PDA detector. The electrophoretic separation was obtained with migration time of 21.8 and 15.8 minutes for the filgrastim and leuprorrelin acetate (internal standard), respectively, and with run time of 30 minutes. The procedure was validated by the parameters of specificity, linearity, precision, accuracy, robustness, limit of quantitation and limit of detection. The method was linear in the concentration range of 1 200 μg/mL (r2 = 0.9978) and the limit of quantitation (LOQ) was 1 μg/mL, with acceptable validation parameters. The method was applied for the analysis of pharmaceutical formulations, and the results were correlated to the reversed-phase HPLC method (RP-HPLC), size-exclusion HPLC method (SE-HPLC) and in vitro bioassay method. Therefore, the procedures represent valid alternatives which can improve the quality control, assuring the safety and therapeutic efficacy of the biological product. / O fator estimulador da colônia de granulócitos humanos é uma citocina hematopoiética que estimula e regula a proliferação e diferenciação de células precursoras de neutrófilos da medula óssea. O hormônio recombinante (rhG-CSF) sob a forma não-glicosilada, filgrastima, é usado para o tratamento de neutropenia induzida por quimioterapia e transplante de medula óssea. A proteína hidrofóbica é constituída por uma cadeia de 175 aminoácidos com uma metionina N-terminal, e massa molecular de 18,8 kDa. No presente estudo, foi desenvolvido e validado método por eletroforese capilar de zona (CZE) para determinação de filgrastima em formulações farmacêuticas. As análises foram realizadas em capilar de sílica fundida (comprimento efetivo de 72 cm e diâmetro interno de 75 μm) e solução eletrolítica composta de tetraborato de sódio 50 mM, pH 9,0. O capilar foi mantido a temperatura de 15 °C, e a tensão aplicada foi de 15 kV. O tempo de injeção foi de 6 s, com pressão de 50 mbar, e detecção por arranjo de diodos (DAD) a 195 nm. A separação eletroforética foi obtida com tempo de migração de 21,8 e 15,8 minutos para filgrastima e acetato de leuprorrelina (padrão interno), respectivamente, e tempo total de corrida de 30 minutos. O procedimento foi validado, avaliando-se os parâmetros de especificidade, linearidade, precisão, exatidão, robustez, limite de quantificação e limite de detecção. Demonstrou-se linearidade na faixa de concentração de 1 200 μg/mL (r2 = 0,9978) e limite de quantificação (LQ) de 1 μg/mL, com os demais parâmetros de validação aceitáveis. O método foi aplicado para análise de formulações farmacêuticas, e os resultados foram correlacionados com os obtidos por cromatografia líquida em fase reversa (CL-FR) e por exclusão molecular (CLEM), e pelo bioensaio in vitro. Deste modo, os procedimentos pesquisados contribuem para o estabelecimento de alternativas que aprimoram o controle da qualidade, garantindo a segurança e eficácia terapêutica do produto biológico.

Page generated in 0.0776 seconds