1

Elnätsautomation i Luleå stadsnät / Electrical grid automation in the center of Luleå city

Parfa Svonni, Sara January 2017 (has links)
Studien är utförd på Luleå Energi Elnät AB (LEEAB) och handlar om elnätsautomation i ett markkabelnät i Luleås stadskärna. Examensarbetet, 15 högskolepoäng, är den avslutande delen i utbildningen Högskoleingenjör inom Elkraftteknik via Luleå tekniska universitet. Elnätsautomation är ett brett begrepp som kan handla om fjärrstyrda lastfrånskiljare/effektbrytare till helautomatiserade elnät. För de flesta elnätsföretagen är det varken ekonomiskt hållbart eller nödvändigt att ha ett helautomatiserat elnät. Det går endast att spekulera om att det kommer ställas högre krav på elnätet men om kraven höjs är det en fördel om elnätet är grundat för elnätsautomation. Eftersom elnätet byggs för fyrtio år framöver kan stora kostnader undvikas genom att ha en grundprincip för vad som ska finnas med vid om-/nybyggnation av nätstationer. Elnätsautomationens syfte är att förkorta avbrottstiderna. SAIDI/SAIFI har undersökts. SAIDI är ett systemindex för genomsnittliga avbrott i elnätet, indikerat i minuter per år per kund. SAIFI är ett systemindex för det genomsnittliga antalet avbrott i elnätet, indikerat i antalet avbrott per år per kund. Slutsatsen efter studien är att SAIDI kan förbättras med hjälp av enklare elnätsautomation men också av en helautomatiserad lösning. SAIFI kan förbättras vid helautomatiserade lösningar, om det leder till att avbrottstiden underskrider tre minuter. Eftersom det som tar längst tid vid ett avbrott i markkabelnät är att hitta felstället, blir feldetekteringen den viktigaste aspekten inom elnätsautomation. Lösningsförslag från Protrol och Netcontrol har presenterats och jämförts. Protrols lösning är billig, kommer som ett färdigt paket med styrning, detektering och eventuellt logik för helautomation, den är också enkel att implementera i befintliga stationer. Netcontrols lösning är dyrare. Den har styrning, feldetektering, elkvalitetsmätning och skyddsfunktioner där det går att beställa de funktionerna som behövs.    För bäst resultat är det en fördel att prova lösningarna, förslagsvis en lösning på varsin slinga. En rekommendation är att implementera lösningen vid om-/nybyggnation av nätstationer för att underlätta installation och få ner kostnaderna. För att lägga grunden för elnätsautomation är rekommendationen att förbereda för optisk fiber, genom att gräva ner optorör om möjlighet finns, och installera motordon till lastfrånskiljare/effektbrytare. / The study is performed at Luleå Energi Elnät AB (LEEAB) and concerns electrical grid automation (distribution automation) in a cable network in the center of the city of Luleå in northern Sweden. The thesis is the final part of the bachelor’s degree in Electric Power Engineering at Luleå University of Technology. Electrical grid automation is a broad concept that can range from remote-controlled load-switches/circuit breakers up to fully automated power grids. For most power companies, it is not economically viable or necessary to have fully automated power grids. If the demands for the power grid increase, it is an advantage to have a foundation for electrical grid automation. The power grid is planned to last for forty years. Big savings can be made by having a basic principle how to build new or reconstruct distribution substations (MV/LV). The purpose of electrical grid automation is to shorten power interruptions. The internationally standardized indices SAIDI and SAIFI have been used in this study. SAIDI is the average duration of the interruptions, expressed in minutes per year and customer. SAIFI is the average number of interruptions, expressed in number of interruptions per year and customer. The conclusion from the study is that SAIDI is improved by electrical grid automation and a fully automated solution. SAIFI could be improved by a fully automated solution, if it causes the interruption time to decrease to less than three minutes. In case of a power interruption in an underground cable grid, locating the fault is what takes the longest. Therefore, locating the fault is the most important task in electrical grid automation. Two different solutions, from Protrol and Netcontrol, have been presented and compared in the study. The solution from Protrol is inexpensive, comes as a complete package of control, detection and possible logic for full automation; it is also easy to implement in existing distribution substations. The solution from Netcontrol is more expensive. The functions for the Netcontrol solution are control, fault detection, power quality measurements and protection functions, where one can order the desired features. For the best results, it is an advantage to try the different solutions, preferably one solution on each network loop. A recommendation for making the installation easier and to save some money is to implement the solution if the distribution substation is about to be replaced or renovated. To prepare for implementation of electrical grid automation a recommendation is to dig pipes for optical fiber and installing mechanism to the load-switches/circuit breakers.
2

Elnätsautomation i distibutionsnätet : Feldetektering och fjärrstyrning som metoder att förbättre leveranssäkerheten i elnätet / Automation in the distribution grid : Fault detection and remote control as methods to improve reliability in the power distribution grid

Bylund, Kristoffer January 2018 (has links)
Att öka leveranskvaliteten i sina elnät är något som varje nätbolag strävar mot. En metod att göra detta kan vara att utrusta nätstationer i mellanspänningsnätet med feldetektering och fjärrstyrning för snabbare felsökning och sektionering vid fel. I denna studie har dessa möjligheter utretts och även de potentiella vinsterna i kortare avbrottstider mätt i indikatorn SAIDI. Studien har resulterat i ett förslag för fortsatt investering i feldetektering och fjärrstyrning i Umeå Energis elnät. Den metod som använts är att beräkna SAIDI för det värsta felscenariot för varje matande linje som tittats på, både med och utan elnätsautomation. Det förslag som tagits fram har utgått ifrån de enskilda matningarna förutsättningar vad gäller kundantal, antal nätstationer och nättopologi och har sedan jämförts med två standardalternativ, med detektering i samtliga nätstationer samt detektering i mitten av linjen. Resultatet visar att det förslag som lämnats till Umeå Energi har potential att sänka det summerade SAIDI-värdet vid värsta felscenario från 37 minuter till 10 minuter i de matningar som undersökts. Detta till en kostnad av mindre än två miljoner kronor, eller en kostnad per potentiellt minskad SAIDI-minut på ca. 70 000 kr. Studien har tittat på 16 matande linjer med totalt ca. 17 000 kunder.