• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 10
  • 10
  • 10
  • 10
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uma metodologia para gestão da eficiência energética de centrais de cogeração a biomassa: aplicação ao bagaço de cana. / A methodology for energy efficiency management of biomass cogeneration plants: application to sugarcane bagasse.

Paro, André de Carvalho 09 August 2011 (has links)
Em função do crescimento populacional e econômico brasileiro, o sistema elétrico nacional está sempre em modificação a fim de atender às necessidades do país. Na última década, ganhou destaque o aumento da geração termoelétrica na matriz elétrica nacional, primeiro proveniente do gás natural, e mais recentemente de fontes renováveis, como a cogeração termoelétrica proveniente do bagaço de cana. Em virtude desta realidade, é importante que, frente ao volume significativo e crescente de centrais de cogeração no país, seja pensada uma forma de administrar esta parcela da geração de maneira a se aprimorar de forma constante o desempenho destes sistemas. No entanto, verifica-se que os programas de eficiência energética no Brasil e no mundo estão geralmente associados aos usos finais de energia elétrica e praticamente inexiste uma ação estruturada de gestão da eficiência nas transformações energéticas para geração de eletricidade ao longo de sua operação. Portanto, este trabalho tem como objetivo, propor uma metodologia de gestão continuada da eficiência energética de centrais de cogeração a biomassa que operam em ciclo Rankine no Brasil. A metodologia está baseada no ciclo de melhoria contínua da qualidade, conhecido como PDCA. São estabelecidas as etapas para implementação da metodologia: enquadramento, cálculo, medição, verificação e ação. O parâmetro escolhido para cálculo e medição na metodologia é o fator de utilização de energia (FUE). A implementação da metodologia permite passar por cada fase do ciclo PDCA: planejamento, execução, verificação e ação. O ciclo Rankine foi o escolhido para o desenvolvimento do modelo de aplicação por representar a totalidade das centrais de cogeração a biomassa no Brasil. É apresentado um estudo de caso no qual a metodologia foi aplicada a duas centrais de cogeração enquadradas em classes semelhantes. Os resultados demonstram a validade da metodologia para o propósito de implementar um sistema de gestão continuada da eficiência energética global em centrais de cogeração a biomassa. São por fim recomendadas as ações de melhoria decorrentes da aplicação do ciclo nas centrais, e recomendações de desenvolvimento futuro complementares a este trabalho. / Due to the Brazilian population and economic growth, the national grid is in continuous change in order to meet the country needs. During the last decade, the highlights are the thermoelectric generation expansion, first by natural gas plants growth and recently by alternative renewable cogeneration sugarcane bagasse plants. Due to this situation, face to the significant growing number of biomass cogeneration plants in Brazil, it is important to think a way to manage this electric generation portion in order to have a continuous improvement of its performance. However, it is noticed that the energy efficiency policies either in Brazil or worldwide are usually connected to end uses of electricity and actually there is not any structured action towards the energy efficiency management for electricity generation along operation. Thus, this work proposes a methodology for energy efficiency management in Rankine cycle operated biomass cogeneration plants in Brazil. The methodology is based on the so called PDCA continual improvement cycle. The steps for implementation of the methodology: classification, calculation, measurement, verification and action, are established. The energy utilization factor (EUF) was chosen for calculation and measurement in the methodology. The implementation of it permits to pass through each phase of PDCA cycle: plan, do, check and act. The Rankine cycle was chosen for the application model development because it represents 100% of biomass cogeneration commercial plants operating in Brazil. A application of the methodology for two cogeneration plants with the same class is presented in the study case. The results show the validity of the application of the proposed methodology for establishment of an overall energy efficiency management system in biomass cogeneration plants. Improvement actions are recommended as results from the application of the cycle. Further development recommendations for this work are also presented.
2

Aquecimento solar de água: metodologia de avaliação da incerteza na medição do desempenho térmico de coletores solares planos utilizando simulador artificial de radiação solar. / Solar water heating: methodology for uncertainty evaluation of solar thermal collectors performance using a solar simulator.

Sowmy, Daniel Setrak 30 August 2013 (has links)
Este trabalho apresenta uma metodologia de avaliação da incerteza associada à medição do desempenho térmico de coletores solares térmicos, utilizados em aquecedores de água residenciais. A determinação desta grandeza tem influência direta na estimativa da fração solar obtida pelo sistema, e consequentemente no tempo de retorno sobre o investimento do mesmo. Coletores solares planos, construídos a partir de perfis de alumínio, com absorvedores metálicos, pintura preta não seletiva, tubulação interna de cobre, cobertura de vidro simples e isolante térmico na parte traseira, foram ensaiados individualmente em laboratório para determinação do seu desempenho. O procedimento adotado foi o indoor, onde os ensaios são realizados sob um simulador artificial de radiação solar, e envolveu a configuração da câmara de testes, estabilização das variáveis ambientais, ensaios das amostras, cálculo do desempenho térmico e estimativa da sua incerteza associada. Esta última levou em consideração as contribuições da instrumentação empregada, da estabilidade temporal das condições de contorno para realização das medições e do método estatístico utilizado na determinação da curva de desempenho térmico do coletor. Ao final do estudo foram ponderados os limites aceitos pelo programa de etiquetagem brasileiro de coletores em comparação com os resultados obtidos. / This work presents a methodology for assessing the thermal performance uncertainty of solar collectors used in residential water heaters. The uncertainty has a direct influence on the solar fraction prediction and consequently on its payback time. Flat solar collectors, built in aluminum frames, metallic absorber with non-selective black paint, copper pipes, single glass cover and thermal insulation on the back, were tested individually at the laboratory to measure their performance. The test procedure was the indoor, performed on an artificial solar simulator, and included the test chamber set-up, environmental variables control, sample testing, thermal performance calculating and its uncertainty estimate. The latter considered the instrumentation, temporal stability of variables and the statistical method used on the collectors thermal performance curve fitting. The study also compared the results obtained with the performance limits accepted by the Brazilian collector labeling program.
3

Eficiência energética e capacidade: estratégias de alocação de recursos em redes sem fio de múltiplo acesso. / Energy efficiency and capacity: resource allocation strategies in wireless multiple acess networks.

Lucas Dias Hiera Sampaio 13 May 2015 (has links)
Neste trabalho são investigados problemas de alocação de espetro e potência em redes sem fio de múltiplo acesso e propostas sete soluções distintas para diferentes cenários e topologias que serão enumeradas a seguir. Primeiramente o problema de maximização da eficiência energética em redes cooperativas do tipo multiportadora com múltiplo acesso por divisão de código de sequência direta é abordado e as seguintes soluções são apresentadas: duas abordagens na perspectiva de teoria de jogos, uma utilizando algoritmo de water-filling (1) e outra utilizando o algoritmo distribuído de controle de potência baseado no equilíbrio de Verhulst (2), uma terceira solução também inspirado no último algoritmo citado e na média dos coeficientes de canal das subportadoras do sistema (3); uma abordagem heurística utilizando o algoritmo dos vaga-lumes (4) e outra utilizando a otimização por enxame de partículas (5). Em segundo lugar, foram investigados problemas de otimização em sistemas de múltiplo acesso por divisão ortogonal de frequência com provisão de qualidade de serviço estatística. Nesta segunda topologia dois problemas distintos foram analisados: o primeiro problema de maximização da capacidade efetiva do sistema foi solucionado utilizando o método de decomposição dual de Lagrange (6), o segundo problema cujo objetivo é a maximização da eficiência energética efetiva foi investigado e um solução baseada na combinação do método de Dinkelba e da decomposição dual de Lagrange foi proposta (7). Simulações computacionais foram conduzidas tendo em vista averiguar o desempenho das abordagens propostas e, quando possível, tais resultados numéricos foram comparados àqueles obtidos a partir de algoritmos alternativos existentes na literatura. / This work investigates the spectrum and power allocation problems in wireless multiple access networks and seven dfferent solutions to different scenarios and topologies, which are enumerated as follows. Three distinct solutions are presented to the energy effiency maximization problem in multicarrier direct sequence code division multiple acess cooperative: two game theoretic approaches, one using the iterative water-filling algorithm (1) and another one using the distributed power control algorithm based on Verhulst equilibrium concept (2), and a third solution also based on the last algorithm but considering the average channel power gain (3); an heuristic approach using the firefly algorithm (4) and the particle swarm optimization algorithm (5). In orthogonal frequency division multiple acess networks, optimization problems considering a statistical quality of service metric were analyzed: the first one is the effective capacity maximization which was solved through Lagrange dual decomposition method (6). The second one, in which the objective is to maximize the effective energy effiency was addressed and solution based on the Dinkelba method and further application of Lagrange dual decomposition was developed (7). Simulations were conducted to verify the proposed approaches performance and, whenever possible, the numerical results were compared to previous solution proposed in the literature.
4

Contribuição da inércia térmica na eficiência energética de edifícios de escritórios na cidade de São Paulo. / Effect of the thermal inertia on the energy performance of office buildings in the city of São Paulo.

Brito, Adriana Camargo de 02 October 2015 (has links)
Diante das crises energéticas mundiais é oportuna a retomada de técnicas passivas de climatização de ambientes, como aquelas que consideram a inércia térmica das edificações. No Brasil é reconhecida a sua importância na melhoria do desempenho térmico de habitações, como indicado na norma NBR 15575 que, no método simplificado de avaliação do desempenho térmico, estabelece valores limites para a transmitância térmica e para a capacidade térmica de paredes, de modo a contemplar a influência da inércia térmica. Entretanto, não se dispõe de informações que permitam extrapolar esses critérios para edifícios de escritórios, que têm diferentes dinâmicas de uso e volumetria. Tendo como principal objetivo apresentar recomendações e critérios para o projeto de edifícios de escritórios na cidade de São Paulo, onde a inércia térmica dos ambientes pode contribuir para a redução ou a eliminação do uso de sistemas de ar condicionado, foi desenvolvido o presente trabalho. Para tal foram efetuadas simulações computacionais da resposta térmica de escritórios, analisados com variações nos seguintes parâmetros: área de piso; proporção de área na fachada em relação ao seu volume; nível de ocupação; taxa de ventilação; cor da fachada; sombreamento de aberturas; tipo de parede e temperatura de referência para o conforto térmico dos usuários. De modo geral, os resultados demonstraram que: ambientes ocupados, com paredes de maior capacidade térmica, menor área de piso e maior área na fachada em relação ao volume do ambiente, têm melhor desempenho térmico, especialmente com o uso de cores claras nas fachadas e dispositivos de sombreamento em aberturas. Tais características têm contribuição mais significativa na redução da demanda por climatização de ambientes somente se for adotada uma temperatura de referência do ar interior acima dos valores tipicamente usados nessas edificações. As recomendações e critérios apresentados para o projeto de escritórios consideram o uso de ambientes com ventilação, utilizando-se sistemas de climatização somente em menos de 15% das horas de um ano típico da cidade de São Paulo. / The global energy crises provide a further reason to use passive techniques, such as the thermal inertia, for cooling buildings. In Brazil, the importance of thermal inertia for the improvement of the thermal performance of dwellings is recognized and has been incorporated into the standard NBR 15575. For the assessment of the thermal performance, this standard establishes limit values for the thermal transmittance and the thermal capacity of walls, taking into account the influence of thermal inertia. However, there is no equivalent information available for offices, which can have very different characteristics. This thesis develops recommendations and criteria for the design of office buildings in the city of São Paulo, where the thermal inertia contributes to a reduction of energy consumption for cooling. Parametric simulations of typical offices were performed, varying the following parameters: floor area; façade-surface-area/volume ratio; internal gains (people, equipment etc.); ventilation rate; facade color and shading. The results showed that offices with walls made of components with higher thermal capacity, smaller floor area and larger façade-surface-area/volume ratio have better thermal performance. Light colors of the façade, shading devices and increased ventilation rate provided further improvement in the thermal performance of the offices. These characteristics may have significant contribution in reducing the energy demand for cooling depending on the value of the inside air temperature adopted. The recommendations and criteria presented for design of offices consider the use of air conditioning in less than 15% of the hours in a typical year in the city of São Paulo.
5

Eficiência energética e capacidade: estratégias de alocação de recursos em redes sem fio de múltiplo acesso. / Energy efficiency and capacity: resource allocation strategies in wireless multiple acess networks.

Sampaio, Lucas Dias Hiera 13 May 2015 (has links)
Neste trabalho são investigados problemas de alocação de espetro e potência em redes sem fio de múltiplo acesso e propostas sete soluções distintas para diferentes cenários e topologias que serão enumeradas a seguir. Primeiramente o problema de maximização da eficiência energética em redes cooperativas do tipo multiportadora com múltiplo acesso por divisão de código de sequência direta é abordado e as seguintes soluções são apresentadas: duas abordagens na perspectiva de teoria de jogos, uma utilizando algoritmo de water-filling (1) e outra utilizando o algoritmo distribuído de controle de potência baseado no equilíbrio de Verhulst (2), uma terceira solução também inspirado no último algoritmo citado e na média dos coeficientes de canal das subportadoras do sistema (3); uma abordagem heurística utilizando o algoritmo dos vaga-lumes (4) e outra utilizando a otimização por enxame de partículas (5). Em segundo lugar, foram investigados problemas de otimização em sistemas de múltiplo acesso por divisão ortogonal de frequência com provisão de qualidade de serviço estatística. Nesta segunda topologia dois problemas distintos foram analisados: o primeiro problema de maximização da capacidade efetiva do sistema foi solucionado utilizando o método de decomposição dual de Lagrange (6), o segundo problema cujo objetivo é a maximização da eficiência energética efetiva foi investigado e um solução baseada na combinação do método de Dinkelba e da decomposição dual de Lagrange foi proposta (7). Simulações computacionais foram conduzidas tendo em vista averiguar o desempenho das abordagens propostas e, quando possível, tais resultados numéricos foram comparados àqueles obtidos a partir de algoritmos alternativos existentes na literatura. / This work investigates the spectrum and power allocation problems in wireless multiple access networks and seven dfferent solutions to different scenarios and topologies, which are enumerated as follows. Three distinct solutions are presented to the energy effiency maximization problem in multicarrier direct sequence code division multiple acess cooperative: two game theoretic approaches, one using the iterative water-filling algorithm (1) and another one using the distributed power control algorithm based on Verhulst equilibrium concept (2), and a third solution also based on the last algorithm but considering the average channel power gain (3); an heuristic approach using the firefly algorithm (4) and the particle swarm optimization algorithm (5). In orthogonal frequency division multiple acess networks, optimization problems considering a statistical quality of service metric were analyzed: the first one is the effective capacity maximization which was solved through Lagrange dual decomposition method (6). The second one, in which the objective is to maximize the effective energy effiency was addressed and solution based on the Dinkelba method and further application of Lagrange dual decomposition was developed (7). Simulations were conducted to verify the proposed approaches performance and, whenever possible, the numerical results were compared to previous solution proposed in the literature.
6

Uma metodologia para gestão da eficiência energética de centrais de cogeração a biomassa: aplicação ao bagaço de cana. / A methodology for energy efficiency management of biomass cogeneration plants: application to sugarcane bagasse.

André de Carvalho Paro 09 August 2011 (has links)
Em função do crescimento populacional e econômico brasileiro, o sistema elétrico nacional está sempre em modificação a fim de atender às necessidades do país. Na última década, ganhou destaque o aumento da geração termoelétrica na matriz elétrica nacional, primeiro proveniente do gás natural, e mais recentemente de fontes renováveis, como a cogeração termoelétrica proveniente do bagaço de cana. Em virtude desta realidade, é importante que, frente ao volume significativo e crescente de centrais de cogeração no país, seja pensada uma forma de administrar esta parcela da geração de maneira a se aprimorar de forma constante o desempenho destes sistemas. No entanto, verifica-se que os programas de eficiência energética no Brasil e no mundo estão geralmente associados aos usos finais de energia elétrica e praticamente inexiste uma ação estruturada de gestão da eficiência nas transformações energéticas para geração de eletricidade ao longo de sua operação. Portanto, este trabalho tem como objetivo, propor uma metodologia de gestão continuada da eficiência energética de centrais de cogeração a biomassa que operam em ciclo Rankine no Brasil. A metodologia está baseada no ciclo de melhoria contínua da qualidade, conhecido como PDCA. São estabelecidas as etapas para implementação da metodologia: enquadramento, cálculo, medição, verificação e ação. O parâmetro escolhido para cálculo e medição na metodologia é o fator de utilização de energia (FUE). A implementação da metodologia permite passar por cada fase do ciclo PDCA: planejamento, execução, verificação e ação. O ciclo Rankine foi o escolhido para o desenvolvimento do modelo de aplicação por representar a totalidade das centrais de cogeração a biomassa no Brasil. É apresentado um estudo de caso no qual a metodologia foi aplicada a duas centrais de cogeração enquadradas em classes semelhantes. Os resultados demonstram a validade da metodologia para o propósito de implementar um sistema de gestão continuada da eficiência energética global em centrais de cogeração a biomassa. São por fim recomendadas as ações de melhoria decorrentes da aplicação do ciclo nas centrais, e recomendações de desenvolvimento futuro complementares a este trabalho. / Due to the Brazilian population and economic growth, the national grid is in continuous change in order to meet the country needs. During the last decade, the highlights are the thermoelectric generation expansion, first by natural gas plants growth and recently by alternative renewable cogeneration sugarcane bagasse plants. Due to this situation, face to the significant growing number of biomass cogeneration plants in Brazil, it is important to think a way to manage this electric generation portion in order to have a continuous improvement of its performance. However, it is noticed that the energy efficiency policies either in Brazil or worldwide are usually connected to end uses of electricity and actually there is not any structured action towards the energy efficiency management for electricity generation along operation. Thus, this work proposes a methodology for energy efficiency management in Rankine cycle operated biomass cogeneration plants in Brazil. The methodology is based on the so called PDCA continual improvement cycle. The steps for implementation of the methodology: classification, calculation, measurement, verification and action, are established. The energy utilization factor (EUF) was chosen for calculation and measurement in the methodology. The implementation of it permits to pass through each phase of PDCA cycle: plan, do, check and act. The Rankine cycle was chosen for the application model development because it represents 100% of biomass cogeneration commercial plants operating in Brazil. A application of the methodology for two cogeneration plants with the same class is presented in the study case. The results show the validity of the application of the proposed methodology for establishment of an overall energy efficiency management system in biomass cogeneration plants. Improvement actions are recommended as results from the application of the cycle. Further development recommendations for this work are also presented.
7

Aquecimento solar de água: metodologia de avaliação da incerteza na medição do desempenho térmico de coletores solares planos utilizando simulador artificial de radiação solar. / Solar water heating: methodology for uncertainty evaluation of solar thermal collectors performance using a solar simulator.

Daniel Setrak Sowmy 30 August 2013 (has links)
Este trabalho apresenta uma metodologia de avaliação da incerteza associada à medição do desempenho térmico de coletores solares térmicos, utilizados em aquecedores de água residenciais. A determinação desta grandeza tem influência direta na estimativa da fração solar obtida pelo sistema, e consequentemente no tempo de retorno sobre o investimento do mesmo. Coletores solares planos, construídos a partir de perfis de alumínio, com absorvedores metálicos, pintura preta não seletiva, tubulação interna de cobre, cobertura de vidro simples e isolante térmico na parte traseira, foram ensaiados individualmente em laboratório para determinação do seu desempenho. O procedimento adotado foi o indoor, onde os ensaios são realizados sob um simulador artificial de radiação solar, e envolveu a configuração da câmara de testes, estabilização das variáveis ambientais, ensaios das amostras, cálculo do desempenho térmico e estimativa da sua incerteza associada. Esta última levou em consideração as contribuições da instrumentação empregada, da estabilidade temporal das condições de contorno para realização das medições e do método estatístico utilizado na determinação da curva de desempenho térmico do coletor. Ao final do estudo foram ponderados os limites aceitos pelo programa de etiquetagem brasileiro de coletores em comparação com os resultados obtidos. / This work presents a methodology for assessing the thermal performance uncertainty of solar collectors used in residential water heaters. The uncertainty has a direct influence on the solar fraction prediction and consequently on its payback time. Flat solar collectors, built in aluminum frames, metallic absorber with non-selective black paint, copper pipes, single glass cover and thermal insulation on the back, were tested individually at the laboratory to measure their performance. The test procedure was the indoor, performed on an artificial solar simulator, and included the test chamber set-up, environmental variables control, sample testing, thermal performance calculating and its uncertainty estimate. The latter considered the instrumentation, temporal stability of variables and the statistical method used on the collectors thermal performance curve fitting. The study also compared the results obtained with the performance limits accepted by the Brazilian collector labeling program.
8

Contribuição da inércia térmica na eficiência energética de edifícios de escritórios na cidade de São Paulo. / Effect of the thermal inertia on the energy performance of office buildings in the city of São Paulo.

Adriana Camargo de Brito 02 October 2015 (has links)
Diante das crises energéticas mundiais é oportuna a retomada de técnicas passivas de climatização de ambientes, como aquelas que consideram a inércia térmica das edificações. No Brasil é reconhecida a sua importância na melhoria do desempenho térmico de habitações, como indicado na norma NBR 15575 que, no método simplificado de avaliação do desempenho térmico, estabelece valores limites para a transmitância térmica e para a capacidade térmica de paredes, de modo a contemplar a influência da inércia térmica. Entretanto, não se dispõe de informações que permitam extrapolar esses critérios para edifícios de escritórios, que têm diferentes dinâmicas de uso e volumetria. Tendo como principal objetivo apresentar recomendações e critérios para o projeto de edifícios de escritórios na cidade de São Paulo, onde a inércia térmica dos ambientes pode contribuir para a redução ou a eliminação do uso de sistemas de ar condicionado, foi desenvolvido o presente trabalho. Para tal foram efetuadas simulações computacionais da resposta térmica de escritórios, analisados com variações nos seguintes parâmetros: área de piso; proporção de área na fachada em relação ao seu volume; nível de ocupação; taxa de ventilação; cor da fachada; sombreamento de aberturas; tipo de parede e temperatura de referência para o conforto térmico dos usuários. De modo geral, os resultados demonstraram que: ambientes ocupados, com paredes de maior capacidade térmica, menor área de piso e maior área na fachada em relação ao volume do ambiente, têm melhor desempenho térmico, especialmente com o uso de cores claras nas fachadas e dispositivos de sombreamento em aberturas. Tais características têm contribuição mais significativa na redução da demanda por climatização de ambientes somente se for adotada uma temperatura de referência do ar interior acima dos valores tipicamente usados nessas edificações. As recomendações e critérios apresentados para o projeto de escritórios consideram o uso de ambientes com ventilação, utilizando-se sistemas de climatização somente em menos de 15% das horas de um ano típico da cidade de São Paulo. / The global energy crises provide a further reason to use passive techniques, such as the thermal inertia, for cooling buildings. In Brazil, the importance of thermal inertia for the improvement of the thermal performance of dwellings is recognized and has been incorporated into the standard NBR 15575. For the assessment of the thermal performance, this standard establishes limit values for the thermal transmittance and the thermal capacity of walls, taking into account the influence of thermal inertia. However, there is no equivalent information available for offices, which can have very different characteristics. This thesis develops recommendations and criteria for the design of office buildings in the city of São Paulo, where the thermal inertia contributes to a reduction of energy consumption for cooling. Parametric simulations of typical offices were performed, varying the following parameters: floor area; façade-surface-area/volume ratio; internal gains (people, equipment etc.); ventilation rate; facade color and shading. The results showed that offices with walls made of components with higher thermal capacity, smaller floor area and larger façade-surface-area/volume ratio have better thermal performance. Light colors of the façade, shading devices and increased ventilation rate provided further improvement in the thermal performance of the offices. These characteristics may have significant contribution in reducing the energy demand for cooling depending on the value of the inside air temperature adopted. The recommendations and criteria presented for design of offices consider the use of air conditioning in less than 15% of the hours in a typical year in the city of São Paulo.
9

Desempenho energético e caracterização dos sistemas de aquecimento de água de piscinas. / Energetic performance and characterization of swimming pool heating systems.

Maluf, Claudio Azer 16 June 2010 (has links)
O objetivo deste trabalho é investigar o desempenho energético de dois diferentes tipos de sistemas de aquecimento de piscinas: á gás natural e por bomba de calor elétrica. Foi realizada instrumentação em duas piscinas localizadas em uma mesma academia, cada uma delas dotada de um dos tipos de sistema de aquecimento. Além destas duas piscinas, que são objeto de investigação desta pesquisa, outras quatro piscinas, localizadas cada uma em um local distinto na cidade de São Paulo, também receberam instrumentação e a coleta de dados está sendo executada através de sistemas de aquisição de dados, para posterior análise e novos trabalhos de pesquisa. Como resultados da análise das duas piscinas, obteve-se um coeficiente de desempenho - COP, médio para o sistema de aquecimento por bomba de calor igual a 4. Para o sistema a gás natural, os resultados para a eficiência global do sistema indicaram 76%, ao passo que o rendimento apenas dos aquecedores foi de 82%. As análises dos dados permitiram comprovar a influência da temperatura ambiente sobre o COP da bomba de calor. Quanto menor a temperatura do ar, menor o COP. A Temperatura do ar também mostrou forte influência sobre o consumo de energia. / The aim of this research is to investigate the energetic performance of two distinct kinds of swimming pool heating systems: gas-fired and electric heat pump. A practical instrumentation research was prepared in these two indoor swimming pools, placed in the same location. Besides these, other four swimming pool, placed each in a different ambient in the city of São Paulo also received the instrumentation so that it will be possible to run future researches, once the data is already being collected by the data loggers installed. As a result of the data analysis, it was found that the average coefficient of performance of the heat pumps studied is 4. For the natural gas fired system, the global efficiency factor was found to be 76%. The efficiency of the heaters isolated was found to be 82%. This research showed that the COP of heat pump systems has strong correlation with the air temperature. The lower the air temperature, the lower the COP. Temperature also has strong influence on the consumption of energy.
10

Desempenho energético e caracterização dos sistemas de aquecimento de água de piscinas. / Energetic performance and characterization of swimming pool heating systems.

Claudio Azer Maluf 16 June 2010 (has links)
O objetivo deste trabalho é investigar o desempenho energético de dois diferentes tipos de sistemas de aquecimento de piscinas: á gás natural e por bomba de calor elétrica. Foi realizada instrumentação em duas piscinas localizadas em uma mesma academia, cada uma delas dotada de um dos tipos de sistema de aquecimento. Além destas duas piscinas, que são objeto de investigação desta pesquisa, outras quatro piscinas, localizadas cada uma em um local distinto na cidade de São Paulo, também receberam instrumentação e a coleta de dados está sendo executada através de sistemas de aquisição de dados, para posterior análise e novos trabalhos de pesquisa. Como resultados da análise das duas piscinas, obteve-se um coeficiente de desempenho - COP, médio para o sistema de aquecimento por bomba de calor igual a 4. Para o sistema a gás natural, os resultados para a eficiência global do sistema indicaram 76%, ao passo que o rendimento apenas dos aquecedores foi de 82%. As análises dos dados permitiram comprovar a influência da temperatura ambiente sobre o COP da bomba de calor. Quanto menor a temperatura do ar, menor o COP. A Temperatura do ar também mostrou forte influência sobre o consumo de energia. / The aim of this research is to investigate the energetic performance of two distinct kinds of swimming pool heating systems: gas-fired and electric heat pump. A practical instrumentation research was prepared in these two indoor swimming pools, placed in the same location. Besides these, other four swimming pool, placed each in a different ambient in the city of São Paulo also received the instrumentation so that it will be possible to run future researches, once the data is already being collected by the data loggers installed. As a result of the data analysis, it was found that the average coefficient of performance of the heat pumps studied is 4. For the natural gas fired system, the global efficiency factor was found to be 76%. The efficiency of the heaters isolated was found to be 82%. This research showed that the COP of heat pump systems has strong correlation with the air temperature. The lower the air temperature, the lower the COP. Temperature also has strong influence on the consumption of energy.

Page generated in 0.0872 seconds