• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1231
  • 781
  • Tagged with
  • 2012
  • 1976
  • 1945
  • 194
  • 171
  • 137
  • 126
  • 125
  • 121
  • 114
  • 107
  • 105
  • 101
  • 94
  • 89
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
401

Energieffektivisering av flerbostadshus : En historisk översikt av energikrav, energianvändning och byggteknisk utveckling / Energy efficiency of multi-family houses

Edström, Niklas, Eriksson, Viktor January 2017 (has links)
Rapportens syfte är att undersöka vad som har skett inom energieffektivisering avflerbostadshus. Resultatdelen är uppdelad i tre delar. Den första delen är undersökning av Boverkets byggregler om energikrav och annat som rör energieffektivisering. Allt från de första byggföreskrifterna som fanns i Sverige till dagens energikrav avhandlas. Boverket släpper med jämna mellanrum nya föreskrifter där energikraven skärps. I del två undersöks hur energianvändningen i Sveriges flerbostadshus de senaste åren ur ett antal olika perspektiv. Den tredje och sista resultat delen handlar om vilka nya tekniker och tekniska lösningar som utvecklats de senaste åren. Konstruktion, isolering, köldbryggor och fönster är de fyra områden som undersökts. Den totala energianvändning i flerbostadshus har sjunkit marginellt de senaste 15 åren, den genomsnittliga energianvändning har dock sjunkit något mer. Detta beror främst på ökad medvetenhet om vikten av energieffektivisering än stora tekniska framsteg inom området. Boverkets byggregler gällande energikrav har genom åren skärpts regelbundet, men dessa har sällan varit svåra att uppnå för nybyggnationer. / The purpose of the report is to investigate what has occurred in energy efficiency technology of multi-family residential. The result is divided into three parts. The first part is an examination of the Swedish National Board of Housing, Building andPlanning's building rules on energy requirements. Everything from the first building regulations in Sweden to today's energy requirements are being investigated. The National Board of Housing, Building and Planning is periodically releasing new regulations where the energy requirements are tightened. Part two examines how the energy use in Sweden's multi-family residential has developed in the recent years from a number of different perspectives. The third and last part of the result part is about the technologies and technical solutions that have been developed in recent years. Construction, insulation, thermal bridges and windows are the four areas investigated. Sweden´s total energy use in multi-family residentials has gone down marginally over the last 15 years, but the average energy consumption has fallen a bit further. This is primarily due to increased awareness of the importance of energy efficiency rather than major technical advances. The National Board of Housing, Building and Planning's building rules for energy requirements have been tightened regularlyover the years, but these have not been difficult to achieve for new constructions.
402

En grundläggande matematisk modell på soldriven hybridventilation : För ett kontorslandskap beläget i Stockholm / A basic mathematical model for solar powered hybrid ventilation : for an office landscape located in Stockholm

Karlsson, Robert, Lin, Jiacheng January 2017 (has links)
I Sverige står bostads- och servicesektorn för 40% av den totala slutliga energianvändningen. Byggnader har en lång livslängd och därför krävs det att renoveringar och nya byggnader användersmarta energisnåla system. Naturliga ventilationssystem i byggnader är energisnålare änmekaniska ventilationssystem och därmed att föredra. Dock är de beroende på väderförhållande. Med hybridventilation kombinerar man naturlig ventilation med mekanisk ventilation. Man kan med detta system byta mellan naturlig ventilation och mekanisk ventilation för att minimera energikonsumtion, därmed är det mindre beroende av väderförhållande jämfört med ett naturlig tventilationssystem. Syftet med detta projekt är att skapa ett fungerande hybridventilationssystemför en tänkt byggnad i Stockholm. För att kunna skapa modellen användes grundläggande teori inom strömningsmekanik som hydrostatik, Bernoullis ekvation och viskös kanalströmning som grund. Arbetsprocessen variterativ och bestod av att samla in de teoretiska kunskaperna via litteraturstudien. Sedan föra infysikaliska samband i programmet MATLAB och felsöka med hjälp av insamlad teori. Vid införandet av fysikaliska sambanden infördes massbalanser för respektive våning. Resultatet visar att under den betraktade vinterveckan är ventilationsflödena mer än tillräckliga för att uppfylla Svebys riktlinje. Under denna period är skorstenseffekten den dominerande drivkraften för ventilationen. Skorstenseffekten avtar som förväntat högre upp i byggnaden. Förvåning 1 och 2 är luftflöden nästan det dubbla av värdet på 1,3 l/(sm2) som Sveby rekommenderar. Detta kan medföra en ökad energiförbrukning för byggnadens uppvärmning. För våning 3 ligger luftflödet dock nära Svebys rekommenderade värde. Därmed finns det stor risk att under kall höst och vår är de naturliga krafterna inte tillräckliga för att driva ventilationen. Under den betraktade sommarveckans varmaste timme behövdes alla 6 installerade takfläktar för att förse det önskade mängden luftflöde. Den yta som solcellerna behöver beräknades utifrån denna timme till cirka 23 m2. Drivkraften från vind och skorstenseffekten är ungefär lika stora under denna period. Resultatet visar även att koldioxidkoncentrationen i byggnaden under kontorstiderna understiger Boverkets maxgräns på 1000 ppm med god marginal. Det finns många variabler som man bör ta i beaktning vid analys av ventilation och dennaförenklade modell har visat hur hybridventilation kan se ut i en kontorsbyggnad. Resultaten fördenna modell visar att det är möjligt att driva ventilationen för en kontorsbyggnad till stor del frånde naturliga drivkrafterna. / In Sweden, the housing and service sector accounts for 40% of total energy use. Buildings have long lifespans and therefore are energy efficient systems for new buildings and renovations required. Natural ventilation systems in buildings are more energy efficient than mechanical ventilation systems and is therefore preferred. However, they are dependent on the weather conditions. In hybrid ventilation system, natural ventilation is combined with mechanical ventilation. With this system, it is possible to shift between natural ventilation and mechanical ventilation to minimize the energy consumption. Hence, it is less dependent on weather conditions in comparison with a natural ventilation system. The aim of this study is to create a hybrid ventilation system for an imagined office building located in Stockholm. In order to create this model, basic theory in fluid mechanics such as hydrostatic, Bernoulli’sequation and viscous channel flow were used. The work process was iterative and consisted ofcollecting the theoretical knowledge through literature study. The later stages of the work process consisted of inserting the physical relationships into the computer program MATLAB andtroubleshooting with the aid of collected theory. Mass balances were introduced for each floor ofthe building when the physical relationships were inserted. The result shows that during the observed winter-week, the airflows are more than sufficient to meet Sveby’s guideline. During this period the stack-effect is the dominant driving force for theventilation. The stack-effect decreases as expected higher up in the building. For floors 1 and 2, airflows are almost double the value of 1.3 l/(sm2) as Sveby recommends. This can lead to increased energy consumption for the building’s heating system. For floor 3, however, the airflowis close to Sveby’s recommended value. Hence, there is a great risk that during a cold autumn and spring, the natural forces would not be sufficient to drive the operate the ventilation. During the hottest hour of the observed summer-week, all 6 installed ceiling fans were required to provide the desired amount of airflow. The area that the solar cells need is determined based onthis hour, and it is about 23 m2. The driving force from the wind and the stack-effect is about thesame during this period. The result also shows that the concentration of carbon dioxide in the building during office-hours is below the Boverket’s limit of 1000 ppm with a good margin. There are many variables that should be considered when analyzing the ventilation and thissimplified model has shown how hybrid ventilation can look like in an office-building. The result for this model shows that it is possible to operate the office-building’s ventilation with hybridventilation system, where the natural driving forces contribute a big part.
403

Sustainability Practices on University Campuses : Case Study of Zhejiang University and KTH Royal Institute of Technology / Hållbarhetsarbete på universitetscampus : Fallstudie av Zhejiang University och Kungliga Tekniska högskolan

Arvidsson, Ebba, Forsberg, Sofia, Ögren, Sofie January 2017 (has links)
This report provides an analysis of the energy consumption and a study of the sustainabilitywork regarding buildings at Zhejiang University, ZJU, and the Royal Institute of Technology,KTH. Three students from KTH performed a field study at ZJU in Hangzhou, China, in theyear of 2017. By interviewing actors at KTH and ZJU and studying the differences in conditions, policiesand regulations the results shows how the sustainability work regarding buildingsdifferentiates between the universities. The result of the study shows that both universitieshave national goals, policies and regulations they have to follow that give different incentivesto encourage sustainable development. KTH and Sweden also needs to consider laws andpolicies of the European Union, EU. KTH and Akademiska Hus, AH, have sustainabilitygoals of their own while ZJU only have provincial goals in addition to the national. If ZJUwants to be a leading university in the field of sustainable development, the authors suggestthat they make sustainability goals of their own. AH is the property owner at KTH campus and they decide what kind of energy sources to usein their buildings. They cooperate with KTH to establish the sustainability work while ZJUowns all their buildings, which makes them in charge of the sustainability work themselves.To evaluate properties in terms of sustainability, KTH uses Miljöbyggnad certification andZJU is using the Three Star System. The authors have concluded that the difference in prerequisites between the two countriesmakes it difficult for ZJU to use the same amount of renewable energy in their buildings asKTH. If ZJU would like to use only renewables they need to produce it themselves. ZJUmonitors 150 of their 500 buildings, while AH monitors all buildings at KTH. The authorsrecommend that ZJU put sensors in all their buildings to monitor the energy consumption inorder to get a fair image of the situation in terms of energy use.
404

Enhanced boiling heat transfer from a novel nanodendritic micro-porous copper structure

Furberg, Richard January 2006 (has links)
Following licentiate thesis is a summary of the advances made within the research project - Micro- and nano structured surfaces for enhanced boiling heat transfer – which is a collaboration effort between the Divi-sion of Applied Thermodynamics and Refrigeration and the Division of Materials Chemistry at the Royal Institute of Technology (KTH). The main objectives with this research project has been to: develop methods for producing highly efficient boiling surfaces with well defined micro- and nano-structured porous surfaces by the use of micro- and nano-manufacturing techniques. This objective has been achieved and the result is a novel micro-porous surface structure comprising dendritically ordered nano-particles of cop-per. The structure was fabricated by a high-current-density electrode-position process, in which the evolution of hydrogen bubbles serve as a dynamic masking template to the growth of the dendritic copper struc-ture. Important variables were identified that affect the production of the structure and its features, such as surface orientation during electrode-position, pressure and temperature of electrolyte, and a final heat treat-ment of the surface under reduced atmosphere, all of which have previ-ously not been reported on. Experimental tests have been conducted in a widely used refrigerant, R134a, where the micro-porous structure was shown to enhance the boiling performance of a copper surface over 15 times compared to a regular copper surface. The boiling characteristics of the structure were found to be dependent on controllable surface characteristics. The re-markably good boiling performance of the novel micro-porous en-hancement structure has been attributed to its high porosity ( ~94%), a dendritically formed and exceptionally large surface area, and to a high density of well suited vapor escape channels (>50 per mm2). A patent application, intended to protect the enhancement structure and its fabrication method, was submitted to the Swedish patent authorities (PRV) on March 1st, 2006. / QC 20101112
405

Solenergi i stadsmiljö : En fallstudie för implementering av solenergi på Lindes Backe, Årstastråket / Solar energy in urban environments: : A case study of the implementation of solar energy on Lindes Backe, Årstastråket

Passburg, Carl Victor, Joelsson, Magnus January 2018 (has links)
This report addresses the possible integration of solar technology in urban environments. The focus is primarily on the municipality of Stockholm and their set of goals regarding climate. Is solar power an energy source sufficiently mature to be a profitable alternative for a relatively cold and dark country like Sweden, or could perhaps the favorable political incentives make it so? Solar energy currently accounts for only 0,1% of the national electricity production, which means that the goal of solar power to account for 10% of Stockholms total energy mix by 2040 is a tough challenge. The purpose of the report is to investigate the profitability of the application of solar power on the roof of a residential area in Stockholm. This was done through a case study on JM’s newly build residential area, Lindes Backe , whose results gave the potential value from a practical, financial and socio-economic perspective. The case study was then related from a larger perspective to evaluate Stockholm’s set climate goals to assess whether the goals may be reasonable. This report has no customer or client, but is intended for the city of Stockholm and housing developer JM .The result of the case study showed that is was not economically profitable in any case or scenario where the residential area did not consume 100% of the self-produced electricity. Only one case showed to be profitable which was when the solar cells on the roof that leans in the southwest direction, which amounted the greatest solar radiation. The repayment period for this system was roughly 23 years, yielding a rate of return of 5.5%. Depending on the investor, this can be considered not profitable, for a privately owned construction company for example, or it might be acceptable for a developer which attaches a greater importance on the overall socio-economic profit. These investments gave a positive environmental impact, but the lack of economic profitability means that a widespread use of solar energy currently does not seem likely in the region of Stockholm - other than for smaller systems built for individual use. Further cost reduction and advances in the technology can change this is a longer perspective, but this report concludes that the climate goals will be difficult to achieve. / Den här rapporten behandlar möjligheten för integrering av solcellsteknik i urbana miljöer. Fokuset ligger främst på Stockholms kommun och deras uppsatta klimatmål. Är solcellstekniken tillräckligt mogen för att vara ett lönsamt alternativ för ett relativt kallt och mörkt land som Sverige eller kan de gynnsamma politiska stimulanserna annars göra den lönsam? Solenergi utgör i dagsläget endast 0,1% av den nationella elproduktionen vilket innebär att målet att solenergin ska stå för 10% av Stockholms totala energimix till 2040 är utmanande. Syftet med rapporten är att undersöka lönsamheten med en investering i solcellsteknik för användning på taket av ett större bostadsområde i Stockholm. Detta gjordes genom en fallstudie på bostadsutvecklaren JMs nybyggda bostadsområde Lindes backe vars resultat gav det potentiella värdet ur ett praktiskt, finansiellt och samhällsekonomiskt perspektiv. Fallstudien relaterades sedan i ett större perspektiv för att utvärdera Stockholms uppsatta klimatmål för att ge en fingervisning huruvida målen kan tänkas vara rimliga. Rapporten har ingen beställare men är ämnad för Stockholms stad och JM. Fallstudien visade att det inte var ekonomiskt lönsamt i alla fall och scenarion där bostadsområdet inte konsumerade 100% av den egenproducerade elen. Endast ett fall var något lönsamt vilket var en exklusiv placering av solceller på taken som lutar i sydvästlig riktning, vilket gav störst solinstrålning. Här var återbetalningstiden för systemet 23 år och gav ett resulterande avkastningskrav på 5.5%. Beroende på aktör kan detta anses lönsamt eller ej, för ett privatägt byggbolag är detta lågt, men kan vara acceptabelt av en aktör som lägger en stor vikt på den totala samhällsekonomiska vinsten. Dessa investeringar gav en positiv miljöeffekt men avsaknaden av ekonomisk lönsamhet gör att en utbredd användning av solenergi i dagsläget inte verkar troligt i stockholmsregionen- annat än för små aktörer och privatpersoner. En fortsatt kostnadsreducering och teknikutveckling kan förändra detta i ett längre perspektiv men rapportens slutsats att klimatmålen kan bli svåra att uppnå.
406

Solcellsladdare i Stockholm / Solar chargers for electric vehicles in Stockholm

Emilsson, Arvid, Johansson, Hugo January 2018 (has links)
Stockholm har ett uppsatt mål om att bli fritt från fossila bränslen till år 2040 samt producera 10 % av Stockholms energianvändning inom Stockholm. För att uppnå detta behöver främst transportsektorn ställas om då denna är starkt beroende av fossila bränslen. Ett alternativ som ofta diskuteras är möjligheten att använda elfordon med koldioxidneutral el istället för fossila drivmedel. Även om Sverige, relativt många andra länder, redan har en tämligen koldioxidneutral elförsörjning diskuteras alternativa energislag som exempelvis solenergi bland annat på grund av den pågående debatten om den svenska kärnkraftens framtid. I denna rapport undersöks ekonomiska och tekniska aspekter av ett förenklat fall där ett företag antas vilja investera i en elbilsladdare och valet står mellan å ena sidan en anläggning sammankopplad med en solcellsanläggning samt batteri och å andra sidan endast laddningsstationer.Ett solcellssystem baserat på en konstant solcellsarea undersöks för olika kommersiella solcellsmoduler, antal anslutna laddningsstationer och storlekar på batteriet i laddningsstationen för stationär lagring av energi. Mjukvaran PolySun används för att simulera produktionen och användningen av energi. En modul av tunnfilm, mono och polykristallin undersöks då dessa är de vanligaste kommersiella typerna.Ekonomiskt sett är det med den antagna förbrukningsprofilen alltid lönsamt att investera i solceller med och utan batteri i laddningsstationen även om det, med dagens prisläge, alltid är bättre att endast investera i endast solceller. Återbetalningstiden systemet varierade mellan 10 och 14 år utan batteri och 15 och 18 år med batteri och monokristallina moduler hade längst återbetalningstid i båda fallen. Modulen med bäst ekonomiska resultat var den polykristallina modulen och mest produktion hade den monokristallina modulen. Vid investering i solceller rekommenderas den polykristallina modulen.Rekommendationer på framtida arbete är bland annat att göra om studien med en mer utvecklad laddningsprofil samt en mer utvecklad ekonomisk analys. / Stockholm has set a goal to be fossil free by 2040 as well as producing 10 % of the energy used in Stockholm within Stockholm. As the transport sector in Stockholm is highly dependent on fossil fuels this need massive changes. An alternative that is commonly discussed is the possibility to use electric vehicles as a replacement for fossil driven vehicles. Even though Sweden has, relatively to many other countries, a carbon neutral electricity production alternative power sources such as solar power are frequently discussed for reasons such as the ongoing debate on the future of Swedish nuclear power. In this report economical and technical aspects of a simplified case, where a company is assumed to invest in charging points for electric vehicles and the choice is between choosing an integrated system containing, in addition to the charging points, solar panels and a battery. Different commercial photovoltaic modules, sizes of the battery and number of charging points are examined with a constant reference solar panel area with simulations in the software PolySun. One module of thin film, poly-and monocrystalline are used.This makes it hard to guarantee a high share of solar electricity when many charging points are in use. Economically it is, with the used chargin pattern, always profitable to invest in solar modules with and without batteries in the charging station even if, with the prices of today, it is always better to not invest in batteries. The payback time of the system varies between 10 and 14 years without a 10 kWh battery and between 15 and 18 with a battery of the same size. Monocrystalline panels had the longest payback time in both cases. The panel with best results economically was the polycrystalline module and that is the recommendation made.A recommendation on future work is, amongst other, to do a study with more advanced charging patterns as well as a more advanced economic analysis.
407

Placing VOC Sensors forAssessing Air Quality : A CFD Study of Indoor VOC Distribution

Högdahl, Sara January 2018 (has links)
The Swedish Obligatory Ventilation Control (OVK) was established to ensure that ventilation systemsare clean and work according to design. The control system of today is however not perfect, and thereare many aspects of OVK which could be approached differently for improved efficiency and occupanthealth. A current project in Stockholm is looking at the possibility to use sensors, continuouslymetering volatile organic compounds (VOC), temperature, and relative humidity, in place of the airflowmetering of the traditional OVK solution. One of the first issues encountered was sensor placement, asthe sensors must be discreetly installed on available surfaces while the collected air quality data mustrepresent the air in the occupied zone. A second challenge concerns how the sensor outputs should beinterpreted in terms of indoor air quality.The main purpose of this thesis is to suggest a model that can evaluate the suitability of differentplacements of sensors (such as the ceiling, walls, or lamp fixtures) from a VOC perspective. The idea isto evaluate what areas of the room best represent the average air quality of the occupied zone. This partof the study was approached by combining literature review and computational fluid dynamics (CFD)in two case studies; one office and one apartment. The intent behind the iterated method is to present ageneral CFD model that can be easily interpreted and adapted to accommodate new objects (e.g.building types or rooms). A secondary objective is to discuss how temperature and relative humiditycan be included in the spatial position evaluation. Thirdly, the thesis aims to develop a base for furtherdiscussion regarding a method for how the sensor outputs can be combined into a single indoorenvironment quality index. The two last parts were primarily based on literature review.The conclusions drawn in this study include a general CFD model that can be modified to evaluatedifferent spatial location of VOC sensors, and general guidelines regarding placement of VOC meters inoffices or apartments. Also provided in this report is a base for further discussion concerning indoor airquality estimations by combining the provided sensor-outputs, i.e. total VOC, temperature, and relativehumidity. / Den obligatoriska ventilationskontrollen (OVK) infördes i Sverige för att säkerställa attventilationssystem är rena och fungerar som de är designade att göra. Dagens system är dock inteperfekt och det finns många aspekter av OVK som skulle kunna göras annorlunda för att främjaeffektivitet och personers hälsa. Ett pågående projekt i Stockholm vill undersöka möjligheten attersätta eller komplettera den luftflödesmätning som ingår i dagens OVK med kontinuerlig mätning avflyktiga organiska gaser (VOC), temperatur och relativ luftfuktighet med hjälp av sensorer. En av deförsta utmaningarna för projektet är placeringen av sensorer eftersom att de måste vara diskretinstallerade på befintliga ytor, samtidigt som det som uppmäts bör vara representativt för hur luftenupplevs av personer i byggnaden. En annan utmaning för projektet är hur signalerna från sensorn skakombineras för att utvärdera luftkvalitén.Det huvudsakliga syftet med den här studien är att utveckla en modell som kan användas för attutvärdera lämpligheten av olika sensorplaceringar, till exempel tak, väggar och lamparmaturer, utifrånett VOC-perspektiv. Idén är att ge en uppfattning om vilka placeringar som bäst representerarmedelkvalitén på luften i vistelsezonen. Denna del av arbetet baserades på litteraturstudier ochnumeriska beräkningar med CFD (Computational Fluid Dynamics). Den föreslagna modellenapplicerades i två fallstudier, ett kontor och en lägenhet. Avsikten med modellen är att den enkelt skakunna tolkas och anpassas för olika rumstyper. Ett annat syfte med rapporten är att diskutera hurtemperatur och relativ luftfuktighet kan inkluderas i utvärderingen av sensorplacering. Slutligen är etttredje syfte med studien att påbörja en diskussion för hur de tre mätvärdena från sensorn kankombineras i ett gemensamt inomhusklimatindex. De två sistnämnda delarna baserades främst pålitteraturstudier.Slutsatserna inkluderar en generell CFD-modell och metod som kan modifieras för att utvärdera olikaplaceringar av sensorn, samt riktlinjer för var VOC-sensorer bör placeras i kontor eller lägenheterbaserat på två fallstudier. Också inkluderade i rapporten är en diskussionsbas för hur en utvärdering avluftkvalitet kan göras utifrån de tre värdena från sensorn (VOC, temperatur och relativ luftfuktighet).
408

Introducing of Small Scale Waste to Energy Incineration Plantfor Hotel; Heritance Ahungalla in Ahungalla, Sri Lanka

Siriwardhana, Siriwardhana Jathunge Dharshana Samantha January 2018 (has links)
The disposal of Solid Waste has become one of the major environmental issues in SriLanka. Solid waste is often cited as a key cause contributing to environmental degradation.Rapid industrialization and unplanned urbanization has made Asian cities a victim of unmanageablesolid waste. Most of Urban Cities of Sri Lanka, are facing the same problemand still no proper solution has been introduced by the governing parties other than opendumping, which is again generating a huge problem among people, who are living aroundthe area. Balaptiya, where is in down south of Sri Lanka, is one of the urban cities of SriLanka and their daily waste generation is around 5500 kg, which is collected by BalapitiyaLocal Authority and sent to the open dump site at Heenatiya. This city is very popular fortourism as it is in between very famous tourism cities of Bentota and Hikkaduwa. Therecan be seen so many hotels around the city. Among them, Hotel Heritance Ahungalla,which is one of the five star’s hotels in Sri Lanka, locates within Balapitiya Local Authority.Their waste generation is about 600 kg per day.This study is mainly focusing on introducing small scale solid waste incinerator for Municipalsolid waste collected within Balapitiya Local Authority and Hotel Heritance Ahungalle.Hotel Heritance Ahungalla locates down south of the country and is facilitating 152 standardrooms for their guests. The daily hot water requirement is 30 m3, which is currentlysupplying by an oil fired boiler, which monthly running cost is exceeding LKR 1.2 million,for the room usage as well as cloths drying purposes. The waste heat generated by the proposedincinerator is planned to be used to generate saturated steam, while keeping the oilfired boiler in standby condition. Ultimately, this will save the money spending for the fuelfor the oil fired boiler.In this study, the capacity of incineration plant was optimized to 335kg/hr, which is containingof about 837.5 kW of gross energy, by calculating of available solid waste amountfrom the hotel as well as local authority and adding percentage increment forecasting of future.Accordingly, the size of the furnace was calculated. Finally, burning of this solidwaste will help to produce 3.7 tons/hr of saturated steam, which will meet the hotel dailysteam requirement. / Avyttringen av fast avfall har blivit en av de stora miljöfrågorna i Sri Lanka. Fast avfall är oftanämnt som en viktig orsak som bidrar till miljöförstöring. Snabb industrialisering och oplaneradurbanisering har gjort de asiatiska städerna offer för oorganiserat fast avfall. De flesta städer i SriLanka står inför samma problem och fortfarande har ingen riktig lösning införts av de andraregeringspartierna än öppen dumpning, vilket återigen genererar ett stort problem bland människorsom bor runt området. Balaptiya, som ligger i söder om Sri Lanka, är en av städerna i Sri Lanka ochderas dagliga avfallsproduktion är cirka 5500 kg, som samlas in av Balapitiya Local Authority ochskickas till den öppna dumpningsplatsen i Heenatiya. Den här staden är väldigt populär förturismen eftersom den ligger mellan de mycket kända turismstäderna Bentota och Hikkaduwa. Detfinns många hotell runt staden. Bland dem ligger Hotel Heritance Ahungalla, som är ett av defemstjärniga hotellen i Sri Lanka, lokaliserat inom Balapitiya Local Authority. Derasavfallsgeneration är ca 600 kg per dag.Denna studie fokuserar huvudsakligen på att introducera en småskalig förbränningsanläggning förkommunalt fast avfall som har samlats inom Balapitiya Local Authority och Hotel HeritanceAhungalle. Hotel Heritance Ahungalla är lokaliserat söder om landsbygden och har 152 rum. Detdagliga varmvattenbehovet är 30 m3, som för närvarande levereras med hjälp av en oljeeldad panna,vars månadsrörelsekostnad överstiger 1,2 miljoner LKR, för rumsanvändning och torkduk.Avfallsvärmen som genereras av den föreslagna förbränningsanordningen är planerad att användasför att generera mättad ånga, samtidigt som den oljeeldade pannan hålls i standby-läge. I slutändankommer detta att spara pengar, bränsleförbrukningen i den oljeeldade pannan minskar.I denna studie optimerades förbränningsanläggningens kapacitet till 335 kg/h, vilket innehöll cirka837,5 kW bruttoenergi, genom att beräkna tillgänglig mängd avfall från hotellet och kommunen,och lägga till procentuell prognostisering av framtida avfallsmängd. Därefter beräknades storlekenpå ugnen. Förbränning av detta fasta avfall kommer att bidra till att producera 3,7 ton/timmemättad ånga, vilket kommer att uppfylla hotellets dagliga ångkrav.
409

Termisk komfort vid användning av lågsystemtemperatur och högtemperaturkyla / Thermal Comfort using Low Temperature Heating and High Temperature Cooling

Eliasson, Marcus, Tufvesson, Johan January 2018 (has links)
Energy use in buildings accounts for a large part of the world's energy demand and has an importantimpact on the future's sustainable energy system. Geo-energy and district heating and district coolingsystems have become an increasingly common method for heating and cooling buildings around theworld. In order to effectively heat or cool a building, it is crucial that the supply temperature and roomtemperature are close to each other in order to reduce energy losses and energy use. To achieve this, theroom units must be able to maintain thermal comfort in buildings when using these temperatures. In thisthesis, a literature study has been conducted to identify and compile which room units are used inbuildings. A model has been built in IDA ICE to simulate and evaluate thermal comfort when using theroom units found in the literature study. The purpose of this thesis is to provide an overall picture ofwhich hydronic room units are available for buildings and to evaluate the room units with regard tothermal comfort when using supply temperatures close to room temperature. The main results indicatethat room units with high proportion of radiation and capacity with scaling ability provide the bestthermal comfort. Furthermore, the results show that it is possible to maintain thermal comfort in amodern office building with most of the room units when using supply temperatures close to roomtemperature. Finally, the result shows that the need of cooling, in a modern office building located inStockholm, can be covered with all room units using high temperature cooling. / Energianvändningen i byggnader står för en stor del av världens energikonsumtion och har en viktiginverkan på framtidens hållbara energisystem. Geoenergi och fjärrvärme och fjärrkyla har blivit en allt mervanlig metod för att värma och kyla byggnader runt om i världen. För att effektivt kunna värma eller kylaen byggnad är det avgörande att framledningstemperaturen och rumstemperaturen ligger nära varandra föratt minska energiförlusterna och energianvändningen. För att uppnå detta krävs det att slutapparaternaklarar av att upprätthålla termisk komfort i byggnader vid användning av dessa temperaturer. I arbetet haren litteraturstudie utförts för att identifiera och sammanställa vilka slutapparater som används i byggnader.En modell har sedan byggts upp i IDA ICE för att simulera och utvärdera termisk komfort vidanvändning av de slutapparater som funnits i litteraturstudien. Arbetet har som mål att ge en övergripandebild av vilka hydroniska slutapparater som finns tillgängliga för byggnader samt att utvärderaslutapparaterna med avseende på termisk komfort vid användning av framledningstemperaturer som liggernära rumstemperaturen. De främsta resultaten indikerar att slutapparater med hög andel strålning ochkapacitet med möjlighet till uppskalning ger bäst termisk komfort. Fortsättningsvis visar resultaten att detär möjligt att upprätthålla termisk komfort i en modern kontorsbyggnad med de flesta slutapparater vidanvändning av framledningstemperaturer som ligger nära rumstemperaturen. Slutligen visar resultatet attkylbehovet, i en modern kontorsbyggnad placerad i Stockholm, går att täcka med samtliga slutapparatervid användning av högtemperaturkyla.
410

Performance Testing of a MobileThermal Energy Storage System

Maurel, Marion January 2017 (has links)
I Europa utgör industrisektorn 31% av den globala efterfrågan på energi och bland detta går 20 till 50% avden totala energiinmatningen förlorad när värme släpps ut i atmosfären. Samtidigt beskriver the”European Commission Energy Roadmap 2050” vilken viktig roll energilagring i processen för utfasningav fossila bränslen i det europeiska energisystemet har.I linje med dessa observationer testar och utvecklar energiavdelningen vid Kungliga Tekniska Högskolan(KTH) ett projekt med titeln Heat on Wheels. Grundprincipen för detta projekt är att samla spillvärme inomindustrin och frakta den till användare - t.ex. via ett fjärrvärmenät – med hjälpa av ett fasväxlingsmaterial(PCM) som en mellanprodukt för att lagra energi och sedan ta den från en punkt till en annan i en mobiltermisk energilagringsenhet (M-TES).Denna avhandling tar del i att testa utförandet av Erytritol som PCM-lagring och frigöra energi i enprototyp på KTH. Prototypen består av en tubvärmeväxlare nedsänkt i PCM. HTF:en antingen smälterPCM:t (endoterm process) eller fryser det (exoterm process). M-TES lagringskapacitet är ca 178 kWh/m3.Resultaten visar en 2,50 gånger längre laddningstid och en 1,62 gånger längre urladdningstid med etthalverat HTF-flöde. Att halvera HTF-flödet leder också till en 50% minskning av effekten i PCM överhela laddningsprocessen. Kraften mottagen av HTF:en under hela processen halveras då urladdnings-HTF-temperaturen ökar med 33%. Smält/frysprocessen av PCM är beroende av lokaliseringen ilagringsenheten. Icke desto mindre förefaller Erytritol av teknisk kvalitet kunna upprätthålla upprepadeuppvärmnings-och kylnings-cykler, utan märkbart försämrad lagring.Studien visade också att med den föreslagna utformningen skulle uppskalning M-TES med en 700%ökning i längd resultera i en total värmeöverföringskoefficient multiplicerad med 7, vilket därmedsäkerställer en ännu snabbare process laddning/urladdning.En rekommendation för framtida arbete är att undersöka hur man kan homogenisera smältning/frysningav PCM i värmeväxlaren, kanske genom att bättre sprida HTF-flödet mellan rören. Det skulle också varafördelaktigt att arbeta med att minska förlusterna i mellan laddningen och urladdningen för att behålla såmycket energi som möjligt. Ytterligare studier om effekterna av uppskalning av laboratorieprototypen kanockså utföras, med hänsyn till olika konstruktioner såsom en större rördiameter till exempel. / In Europe, the industry sector constitutes 31 % of the global energy demand and among this, 20 to 50 %of the total energy input is lost as heat released to the atmosphere. In the meantime, the EuropeanCommission Energy Roadmap 2050 recognizes the essential role of energy storage in the process ofdecarbonisation of the European energy system.In line with these observations, the Energy Department of the Royal Institute of Technology (KTH) istesting and developing a project entitled Heat on Wheels. The basic principle of this project is to collectsurplus heat of industry and to bring it to users – e.g. via a district heating network – using a phase changematerial (PCM) as an intermediate to store the energy and carry it from one point to another in a mobilethermal energy storage (M-TES) unit.This thesis takes part in testing the performances of Erythritol as a PCM storing and releasing energy in aprototype at KTH. The prototype consists of tube heat exchanger submerged in PCM. The HTF eithermelts the PCM (endothermic process) or freezes it (exothermic process). The M-TES storage density isaround 178 kWh/m3.The results show a 2.50 times longer charging time and a 1.62 times longer discharging time with a halvedHTF flow. Halving the HTF flow also leads to a 50 % decrease in power in the PCM over the wholecharge process. The power received by the HTF during the whole process is halved when increasing thedischarge HTF temperature by 33 %. The melting/freezing process of the PCM is dependent on thelocalization in the storage unit. Nevertheless, technical grade Erythritol seems to sustain repeatedwarming-cooling cycles, without noticeable storage degradation.The study also showed that with the proposed design, upscaling M-TES with a 700 % increase in lengthwould result in an overall heat transfer coefficient multiply on average by 7 ensuring thus an even fastercharge/discharge process.A recommendation for future work is to investigate how to homogenize the melting/freezing of the PCMin the heat exchanger, maybe by better spreading the HTF flow in between the pipes. It would also beadvantageous to work on reducing the losses in between the charge and the discharge in order to keep asmuch energy as possible. Further studies on the impact of upscaling the laboratory prototype can also beconducted, taking into account different designs such as a larger pipe diameter for instance.

Page generated in 0.0689 seconds