Spelling suggestions: "subject:"conergy distribution systems"" "subject:"coenergy distribution systems""
1 |
Métodos para otimização dos ajustes dos reguladores de tensão e zonas de tap em sistemas de distribuição / Methods for optimization of the voltage regulators and tap zones in distribution systemsPereira, Paulo Ricardo da Silva 07 August 2009 (has links)
The new regulations in the electric sector utilities have have requested greater efficiency and quality both in terms of continuity and in conformity of the energy
supplied. Electrical equipments quality, efficiency and useful life depend directly of the power quality supplied. In addition to operation of equipments, supply of energy
within the limits must be appropriate for the economic development of regions attended. Considering these factors, to improve quality and ensure conformity of the
voltage levels over the distribution networks, the companies are investing in improvements in the system, equipment, voltage regulators and exchange of the
conductors and building of new feeders and / or substations. Nowadays due to availability of computational tools and algorithms that allow the estimation of state variables at each point of distribution feeders it is possible to evaluate and plan actions for improvement in the system with more correct. But the improvements planned for the primary network, aiming to reduce the voltage drop
and make the system more robust, reflecting the voltage levels in the secondary network and therefore require simultaneous actions to enable the benefits of the
study are obtained . In this context, this work objective is to develop a methodology that allows the definition of TAP's appropriate for each distribution transformer, grouping them in TAP zones, together with an algorithm that defines the settings of voltage regulators,
taking into consideration not only the primary desired voltage, but also its impact on distribution transformers. This methodology can be used on power utilities for power
assisting in the planning and operation of the system.
The work is divided into 7 chapters dealing respectively: review, steady state voltage levels and means of control applied in distribution networks, defining the TAP
zones of processors, defining the parameters of adjustment of voltage regulators, integrated assessment of the voltage regulators and TAP zones, the author's
contributions and considerations on the methodology presented. / As novas regulamentações do setor elétrico têm solicitado das
concessionárias uma maior eficiência e qualidade tanto em termos de continuidade como na conformidade da energia fornecida. A qualidade, eficiência e vida útil dos
aparelhos elétricos dependem diretamente da qualidade da energia fornecida. Além do funcionamento dos equipamentos, o fornecimento da energia dentro dos limites adequados é necessário para o desenvolvimento econômico das regiões atendidas. Diante desses fatores, a fim de melhorar a qualidade e garantir a conformidade dos níveis de tensão ao longo das redes de distribuição, as empresas distribuidoras
investem em melhorias no sistema, equipamentos reguladores de tensão, recondutoramento, construção de novos alimentadores e/ou subestações. Atualmente graças a disponibilidade de ferramentas computacionais e
algoritmos que permitem estimar as variáveis de estado em cada ponto dos alimentadores de distribuição torna-se possível avaliar e planejar ações de melhorias no sistema com maior assertividade. Porém as melhorias planejadas para a rede
primária, com o objetivo de reduzir a queda de tensão e tornar o sistema mais robusto, refletem nos níveis de tensão da rede secundária e por isso necessitam de ações simultâneas para possibilitar que os benefícios do estudo realizado sejam obtidos. Nesse contexto, o presente trabalho tem a proposta de desenvolver uma metodologia que permita a definição dos TAP s adequados para cada transformador
de distribuição, agrupando-os em zonas de TAP, juntamente com um algoritmo que defina os ajustes dos reguladores de tensão levando em consideração não somente a tensão primária desejada, mas também seu impacto nos transformadores de distribuição. Esta metodologia poderá ser aplicada nas empresas distribuidoras de energia elétrica auxiliando nas áreas de planejamento e operação do sistema.
O trabalho está divido em 7 capítulos tratando respectivamente de: revisão bibliográfica; níveis de tensão e meios de controle aplicados nas redes de distribuição; definição das zonas de TAP dos transformadores; definição dos
parâmetros de ajuste dos reguladores de tensão; avaliação integrada dos reguladores de tensão e zonas de TAP; contribuições e considerações do autor a respeito da metodologia apresentada.
|
2 |
Avaliação do impacto dos controladores de excitação na estabilidade transitória de geradores síncronos conectados em sistemas de distribuiçãoResener, Mariana January 2011 (has links)
A conexão de geradores em sistemas de distribuição, usualmente chamados de geradores distribuídos, traz novos aspectos técnicos que devem ser analisados pelas empresas distribuidoras, uma vez que os dispositivos de proteção e controle, bem como as técnicas de planejamento e otimização da operação destes sistemas consideram um sistema radial, ou seja, sem a presença de geradores. Em se tratando de geradores síncronos, sabe-se que os sistemas de excitação podem ser equipados com meios para o ajuste automático de tensão, potência reativa ou fator de potência, sendo que três diferentes modos de controle podem ser aplicados a geradores síncronos: regulação de tensão, regulação de potência reativa ou fator de potência e controle de potência reativa ou fator de potência. Ainda, sabe-se que não há um consenso entre as empresas distribuidoras de energia sobre qual o melhor modo de controle destas máquinas, e na maioria dos casos a estratégia de controle de excitação é definida através de um acordo operativo entre a empresa de distribuição de energia e o produtor independente ou autoprodutor que opera o gerador distribuído. Neste contexto, esta dissertação de mestrado tem como objetivo apresentar contribuições com relação à avaliação da estabilidade transitória de geradores síncronos conectados em sistemas de distribuição, avaliando o impacto que os diferentes modos de controle de excitação podem ocasionar, em diferentes condições de operação do sistema. Como parâmetro principal de análise tem-se o tempo crítico de eliminação de falta, obtido através de exaustivas simulações dinâmicas utilizando dados de um sistema real e considerando diferentes condições de operação do sistema, sendo estas: diferentes modos de controle da geração distribuída, modificação do ganho proporcional do controlador de fator de potência, diferentes pontos de operação da geração distribuída, diferentes cenários de carregamento do sistema e diferentes potências de geração. / The connection of generators in distribution systems, commonly called distributed generation, brings new technical issues that must be analyzed by the utilities, since protection and control devices, as well as techniques for system planning and operation optimizing consider radial systems, i.e. without the presence of generators. In the case of synchronous generators, it is known that the excitation systems can be equipped with means for automatic adjustment of voltage, reactive power or power factor, and three different control modes can be applied to synchronous generators: voltage regulation, reactive power or power factor regulation and reactive power or power factor control. It is also known that there is no consensus among the power distribution companies about which is the best control mode for use in these machines, and in most cases the excitation control strategy is defined by an operating agreement between the company and the energy producer that operates the distributed generator. In this context, this work aims to provide contributions about the transient stability of synchronous generators connected to distribution systems, evaluating the impacts that different control modes may result in different system operating conditions. The main analysis parameter is the critical clearing fault time, obtained through extensive simulations using real system data. The different system operating conditions considered in the simulations are: different control modes, variation of the power factor controller proportional gain, different operating points of the distributed generation, different system loadings and power generation.
|
3 |
Avaliação do impacto dos controladores de excitação na estabilidade transitória de geradores síncronos conectados em sistemas de distribuiçãoResener, Mariana January 2011 (has links)
A conexão de geradores em sistemas de distribuição, usualmente chamados de geradores distribuídos, traz novos aspectos técnicos que devem ser analisados pelas empresas distribuidoras, uma vez que os dispositivos de proteção e controle, bem como as técnicas de planejamento e otimização da operação destes sistemas consideram um sistema radial, ou seja, sem a presença de geradores. Em se tratando de geradores síncronos, sabe-se que os sistemas de excitação podem ser equipados com meios para o ajuste automático de tensão, potência reativa ou fator de potência, sendo que três diferentes modos de controle podem ser aplicados a geradores síncronos: regulação de tensão, regulação de potência reativa ou fator de potência e controle de potência reativa ou fator de potência. Ainda, sabe-se que não há um consenso entre as empresas distribuidoras de energia sobre qual o melhor modo de controle destas máquinas, e na maioria dos casos a estratégia de controle de excitação é definida através de um acordo operativo entre a empresa de distribuição de energia e o produtor independente ou autoprodutor que opera o gerador distribuído. Neste contexto, esta dissertação de mestrado tem como objetivo apresentar contribuições com relação à avaliação da estabilidade transitória de geradores síncronos conectados em sistemas de distribuição, avaliando o impacto que os diferentes modos de controle de excitação podem ocasionar, em diferentes condições de operação do sistema. Como parâmetro principal de análise tem-se o tempo crítico de eliminação de falta, obtido através de exaustivas simulações dinâmicas utilizando dados de um sistema real e considerando diferentes condições de operação do sistema, sendo estas: diferentes modos de controle da geração distribuída, modificação do ganho proporcional do controlador de fator de potência, diferentes pontos de operação da geração distribuída, diferentes cenários de carregamento do sistema e diferentes potências de geração. / The connection of generators in distribution systems, commonly called distributed generation, brings new technical issues that must be analyzed by the utilities, since protection and control devices, as well as techniques for system planning and operation optimizing consider radial systems, i.e. without the presence of generators. In the case of synchronous generators, it is known that the excitation systems can be equipped with means for automatic adjustment of voltage, reactive power or power factor, and three different control modes can be applied to synchronous generators: voltage regulation, reactive power or power factor regulation and reactive power or power factor control. It is also known that there is no consensus among the power distribution companies about which is the best control mode for use in these machines, and in most cases the excitation control strategy is defined by an operating agreement between the company and the energy producer that operates the distributed generator. In this context, this work aims to provide contributions about the transient stability of synchronous generators connected to distribution systems, evaluating the impacts that different control modes may result in different system operating conditions. The main analysis parameter is the critical clearing fault time, obtained through extensive simulations using real system data. The different system operating conditions considered in the simulations are: different control modes, variation of the power factor controller proportional gain, different operating points of the distributed generation, different system loadings and power generation.
|
4 |
Avaliação do impacto dos controladores de excitação na estabilidade transitória de geradores síncronos conectados em sistemas de distribuiçãoResener, Mariana January 2011 (has links)
A conexão de geradores em sistemas de distribuição, usualmente chamados de geradores distribuídos, traz novos aspectos técnicos que devem ser analisados pelas empresas distribuidoras, uma vez que os dispositivos de proteção e controle, bem como as técnicas de planejamento e otimização da operação destes sistemas consideram um sistema radial, ou seja, sem a presença de geradores. Em se tratando de geradores síncronos, sabe-se que os sistemas de excitação podem ser equipados com meios para o ajuste automático de tensão, potência reativa ou fator de potência, sendo que três diferentes modos de controle podem ser aplicados a geradores síncronos: regulação de tensão, regulação de potência reativa ou fator de potência e controle de potência reativa ou fator de potência. Ainda, sabe-se que não há um consenso entre as empresas distribuidoras de energia sobre qual o melhor modo de controle destas máquinas, e na maioria dos casos a estratégia de controle de excitação é definida através de um acordo operativo entre a empresa de distribuição de energia e o produtor independente ou autoprodutor que opera o gerador distribuído. Neste contexto, esta dissertação de mestrado tem como objetivo apresentar contribuições com relação à avaliação da estabilidade transitória de geradores síncronos conectados em sistemas de distribuição, avaliando o impacto que os diferentes modos de controle de excitação podem ocasionar, em diferentes condições de operação do sistema. Como parâmetro principal de análise tem-se o tempo crítico de eliminação de falta, obtido através de exaustivas simulações dinâmicas utilizando dados de um sistema real e considerando diferentes condições de operação do sistema, sendo estas: diferentes modos de controle da geração distribuída, modificação do ganho proporcional do controlador de fator de potência, diferentes pontos de operação da geração distribuída, diferentes cenários de carregamento do sistema e diferentes potências de geração. / The connection of generators in distribution systems, commonly called distributed generation, brings new technical issues that must be analyzed by the utilities, since protection and control devices, as well as techniques for system planning and operation optimizing consider radial systems, i.e. without the presence of generators. In the case of synchronous generators, it is known that the excitation systems can be equipped with means for automatic adjustment of voltage, reactive power or power factor, and three different control modes can be applied to synchronous generators: voltage regulation, reactive power or power factor regulation and reactive power or power factor control. It is also known that there is no consensus among the power distribution companies about which is the best control mode for use in these machines, and in most cases the excitation control strategy is defined by an operating agreement between the company and the energy producer that operates the distributed generator. In this context, this work aims to provide contributions about the transient stability of synchronous generators connected to distribution systems, evaluating the impacts that different control modes may result in different system operating conditions. The main analysis parameter is the critical clearing fault time, obtained through extensive simulations using real system data. The different system operating conditions considered in the simulations are: different control modes, variation of the power factor controller proportional gain, different operating points of the distributed generation, different system loadings and power generation.
|
Page generated in 0.5802 seconds