• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1857
  • 54
  • 20
  • 14
  • 14
  • 14
  • 10
  • 8
  • 6
  • 2
  • 2
  • 2
  • Tagged with
  • 1936
  • 1936
  • 555
  • 538
  • 459
  • 429
  • 402
  • 334
  • 256
  • 210
  • 188
  • 188
  • 176
  • 172
  • 170
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Desenvolvimento de um laboratório virtual para capacitação tecnológica a distância em proteção de sistemas elétricos / Development of a virtual laboratory for distance training in protection of electrical systems

Silva, Carlos Henrique de Castro January 2011 (has links)
SILVA, C. H. C. Desenvolvimento de um laboratório virtual para capacitação tecnológica a distância em proteção de sistemas elétricos. 2011. 89 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2014-01-02T13:44:37Z No. of bitstreams: 1 2011_dis_chcsilva.pdf: 3252671 bytes, checksum: 1e0a922bd4f757b2cc84b884b484021c (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2014-01-07T18:28:07Z (GMT) No. of bitstreams: 1 2011_dis_chcsilva.pdf: 3252671 bytes, checksum: 1e0a922bd4f757b2cc84b884b484021c (MD5) / Made available in DSpace on 2014-01-07T18:28:07Z (GMT). No. of bitstreams: 1 2011_dis_chcsilva.pdf: 3252671 bytes, checksum: 1e0a922bd4f757b2cc84b884b484021c (MD5) Previous issue date: 2011 / As the demand for electrical energy increases and requirements from regulatory agencies for improved reliability, security and efficiency on the operation of electric power systems, the need for professionals ever more qualified on planning and operation power systems also increases. However, with the need for continued technical update and as a result of rationalization policies of costs and provision of personnel for training, the distance learning techniques have evolved and reached different areas of knowledge. This work presents a Simulator for Presence and Distance Learning about Operation and Protection of Electric Systems (STOP). The STOP Simulator is developed in Java, which enables it to be used in the following systems: Unix, Linux, Windows, MacOS. The STOP can be applied in class as well as distance training and is directed to the training of engineering students, technicians and professionals specialized on electric power systems. The STOP is integrated to a Learning Virtual Environment (AVA), the Moodle. The integration enhances the teaching-learning process making it more effective by using a tool able to simulate real life situations. Simulators in virtual environments are an alternative to reducing costs in companies and educational institutions. The STOP is a software tool featuring one-line diagrams with the main components of the protection system, short-circuits simulation and reconfiguration of the system by setting relays for coordination of the system protection and redefinition of parameters. / Com o aumento na demanda de energia elétrica e a exigência de maior confiabilidade, segurança e eficiência na operação de sistemas elétricos de potência por parte dos órgãos reguladores, aumentou a necessidade por profissionais cada vez mais qualificados em planejamento e operação dos sistemas de potência. No entanto, com a necessidade de atualização técnica continuada e em decorrência da política de racionalização de custos e de disponibilização de pessoal, as técnicas de ensino a distância têm evoluído e alcançado abrangência nas mais diferentes áreas do conhecimento. Este trabalho apresenta um Simulador para Treinamento Presencial e a Distância em Operação e Proteção de Sistemas Elétricos (STOP). O simulador STOP é desenvolvido em Java, podendo ser utilizado em ambientes: Unix, Linux, Windows, MacOS. O STOP pode ser aplicado em treinamento presencial e a distância e está voltado à capacitação de estudantes de engenharia, técnicos e profissionais da área de sistemas elétricos de potência. O STOP está integrado a um Ambiente Virtual de Aprendizagem (AVA), o Moodle. A integração enriquece o ensino-aprendizado tornando-o mais efetivo com o uso de uma ferramenta capaz de simular situações reais. Os simuladores em ambientes virtuais são alternativas para a redução de custos em empresas e instituições de ensino. O simulador STOP é um software composto de diagramas unifilares, com a representação dos principais componentes do sistema de proteção, tornando possível ao usuário simular faltas e reconfigurar o sistema elétrico, por meio de ajustes de relés para coordenação da proteção e redefinição de parâmetros.
192

Uma metodologia formal para o planejamento e controle de missões de aeronaves não-tripuladas

Seibel, Conrado Werner January 2000 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2000. / Made available in DSpace on 2015-02-04T20:42:21Z (GMT). No. of bitstreams: 1 325582.pdf: 56374487 bytes, checksum: 6d01840589f0d3f1d6705f60fa19a323 (MD5) Previous issue date: 2000 / Este trabalho descreve uma metodologia formal que objetiva garantir que aeronaves não­ tripuladas, quando operando de forma autônoma, apresentem um comportamento con­dizente com os objetivos da missão durante toda a duração da missão e, se impedidas de exibir tal comportamento, minimizam as conseqüências desta falha. Na fase de planeja­mento da missão, autômatos híbridos lineares são usados para modelar a aeronave utilizada e os recursos necessários à execução de uma missão (condições internas), o ambiente no qual a missão será realizada (condições externas) e um plano de vôo condizente com os objetivos da missão. O modelo resultante é utilizado para a construção de um plano de vôo contendo uma estratégia primária para a consecução dos objetivos da missão e com­portamentos alternativos para todas as situações passíveis ele serem encontradas durante a realização da missão. Durante a execução da missão, urn controlador de vôo reativo a bordo da aeronave é utilizado para selecionar um comportamento adequado com base no progresso da missão, no ambiente no qual a aeronave está operando e no estado interno da mesma.<br> / Abstract : This work describes a formal methodology for mission planning and control for unmanned aerial vehides. Aircraft executing fiight plans developed with our rnethodology are guar­anted to comply with thc mission objectives at all times. If, for any rcason, the flight plan fails, it will fail in a controlled way. During rnission planning, we use linear hybrid automata to modcl thc choscn aircra.ft, thc rcsourccs nccclccl to pcrform a mission anel thc environrnent in which the aircraft will operate. We use the terrns "internal conditions" for the first two anel "external conditions" for the last one. We also model the flight plan itself with hybrid automata. The resulting model is used to construct complete fiight plans. A complete flight plan contains a primary fiight plan, aimed at achieving the mission objec­tives, anel a set of altemative fiight plans for all the possible situations that the aircraft couid encounter during the execution of the rnission. During rnission execution, a reactive, on-board flight controller is used to seiect the most appropriate behavior based on mission progress, external events frorn the enviromnent where the aircraft is operat.ing and the aircraft's internai status.
193

Conversor CC-CC tipo T ZVS PWM

Bandeira Junior, Delvanei Gomes January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:33:38Z (GMT). No. of bitstreams: 1 328199.pdf: 4702209 bytes, checksum: 62903d21034e4a8f1e3f3dc9e00b4d66 (MD5) Previous issue date: 2014 / Este trabalho apresenta o estudo de um conversor CC-CC isolado com comutação suave, saída em corrente, para aplicações envolvendo altas potências, com nome T-Type Zero Voltage Switching Pulse Width Modulated dc-dc converter(TT-ZVS-PWM). O conversor a ser estudado possui quatro interruptores. Dois deles são submetidos à tensão de entrada, já os outros dois são submetidos à metade da tensão de entrada. Todos os interruptores comutam sob tensão nula. O conversor proposto possui as seguintes semelhanças com os conversores Full Bridge Zero Voltage Switching(FB-ZVS-PWM) e Three Level Zero Voltage Switching(TL-ZVS-PWM): (a) Operação simétrica (b) Modulação por largura de pulso com frequência constante (c) comutação sob tensão nula e (d) tensão de saída do conversor com três níveis, a ser aplicada nos terminais do primário do transformador. O trabalho é dividido em análise teórica, análise do modelo de pequenos sinais do conversor e roteiro para projeto do conversor. Um protótipo com 3 kW, 400 V de entrada, 60V de saída e frequência de comutação de 50 kHz comprova a análise desenvolvida. A eficiência obtida no protótipo foi de 93% para carga nominal e de 95,2% para 1,2 kW.<br> / Abstract : This work presents the analysis of the T-Type Zero Voltage Switching Pulse Width Modulated isolated DC-DC converter (TT-ZVS-PWM Converter). The topology is composed of four switches. Two of them are subjected to the input voltage level and the other two to half the input voltage. All primary side switches commutate under zero-voltage. The proposed converter has the following in common with the Full Bridge Zero-Voltage Switching (FB-ZVS-PWM) and the Three-Level Zero-Voltage Switching (TL-ZVS-PWM) converters: (a) symmetrical operation of the isolation transformer, (b) modulation by pulse-width with constant frequency, (c) zero voltage switching, and (d) three-level voltage applied to the primary winding of the transformer. Theoreticalanalysis, small signal model, design example and experimental results for a 3 kW, 400 VDC input, 60 VDC output, and 50 kHz switching frequency laboratory prototype, are included. Measured efficiency was 93% at full load and a peak efficiency of 95.2% occured at 1.2 kW.
194

Conversores CC-CC com elevada taxa de conversão estática

Sá, Franciéli Lima de January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2014. / Made available in DSpace on 2015-03-18T21:08:45Z (GMT). No. of bitstreams: 1 332879.pdf: 16286741 bytes, checksum: 2005f17c524c7bac9188e821186170ee (MD5) Previous issue date: 2014 / Nesse trabalho é introduzida uma nova família de Conversores CC-CC com elevada taxa de conversão estática. Tais conversores tem origem a partir dos Conversores CC-CC básicos convencionais (Buck, Boost, Buck-Boost, Zeta, Cúk e Sepic), no qual inserindo a célula básica de comutação proposta no trabalho, é possível tornar esses conversores convencionais em conversores com elevada taxa de conversão estática, gerando os Conversores Propostos. A célula de comutação responsável por gerar a família de Conversores Propostos possui apenas semicondutores passivos, o que é uma vantagem para essas topologias. Além disso, a família de Conversores Propostos possui a vantagem de ser simétrica, isso possibilita a reflexão dos componentes superiores, gerando os componentes inferiores das novas estruturas. Essa reflexão é uma característica importante nas topologias propostas, pois reduz os esforços de tensão em seus interruptores. Seguindo a nomenclatura básica, os conversores propostos são chamados de: Duplo Buck Quadrático, Duplo Boost Quadrático, Duplo Buck-Boost Quadrático, Duplo Zeta Quadrático, Duplo Cúk Quadrático e Duplo Sepic Quadrático. Dos sete Conversores Propostos no trabalho, somente um não é originado pela célula básica de comutação. Este Conversor é chamado de Duplo Buck Quadrático Básico, e foi importante para consolidar os estudos dos Conversores CC-CC com elevada taxa de conversão estática. Algumas análises como etapas de operação em condução contínua, ganho estático e característica externa são apresentadas para todos os conversores propostos. Para provar as análises teóricas, os resultados experimentais em malha aberta são apresentados para o Conversor Duplo Buck Quadrático Básico, e em malha aberta, malha fechada e malha fechada com desequilíbrio de carga para o Conversor Duplo Boost Quadrático.<br>
195

Investigação de metodologias de validação de modelos de simulação da dinâmica de sistemas elétricos utilizando sincrofasores

Silva, Paulo André Sehn da January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2014. / Made available in DSpace on 2015-04-29T21:08:38Z (GMT). No. of bitstreams: 1 333105.pdf: 3459954 bytes, checksum: f674912cfaf25f34b994218a7c01279b (MD5) Previous issue date: 2014 / Nesta dissertação apresentam-se os resultados da investigação de metodologias para a validação de modelos de simulação da dinâmica de sistemas elétricos de potência utilizando dados fasoriais sincronizados. Com a finalidade de quantificar as diferenças entre registros do sistema e a resposta de simulações, bem como localizar áreas com modelos imprecisos, são propostas quatro estratégias de análise. Na primeira, as discrepâncias são analisadas no domínio do tempo, propondo indicadores quantitativos para o diagnóstico e a localização de modelos imprecisos no sistema. De maneira semelhante, o segundo método quantifica as diferenças entre simulação e registro no domínio da frequência, aplicando a Transformada Discreta de Fourier em ambos os sinais. No terceiro método, são verificadas as discrepâncias em modos de oscilação, sendo considerados a frequência de oscilação, a taxa de amortecimento e os fatores de participação. O quarto método baseia-se na sensibilidade de trajetórias, em que o efeito da mudança de parâmetros é identificado nas medidas do sistema. Para validar as metodologias propostas, experimentos computacionais foram realizados empregando dados de um sistema de pequeno porte e do SIN ? Sistema Interligado Nacional. Os resultados demonstraram a efetividade das metodologias propostas, tanto na quantificação de discrepâncias, quanto na identificação de áreas do sistema com imprecisão nos modelos de simulação.<br> / Abstract : In this dissertation the results for several methodologies for system wide model validation using synchronized phasor data are presented. Four methods for diagnosing the existence of errors in simulation models are proposed. These strategies are meant to quantify discrepancies between the simulation results and the system records and identify the source of errors in simulation models. In the first approach, discrepancies are measured in the time domain to identify areas with models misrepresented. In the second method, the differences between simulation and measurements are determined in the frequency domain by applying the Discrete Fourier Transform in both signals. In the third method, discrepancies in the oscillation modes are attributed to errors in the system components models listed in the participation factors associated with that mode. The fourth method is based on the sensitivity trajectory, where the effect of changing parameters is identified in the measurements of system. Results obtained by simulation confirm the applicability of the proposed methods for the identification of areas containing models errors.
196

Modelo binível de despacho ótimo de potência ativa e reativa baseado nas condições necessárias de Fritz-John normalizadas

Kocholik, Aline January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2015. / Made available in DSpace on 2015-09-08T04:07:53Z (GMT). No. of bitstreams: 1 334111.pdf: 781878 bytes, checksum: 4bbafb5ff12690e346a15a023173a67d (MD5) Previous issue date: 2015 / Neste trabalho é apresentado um modelo de despacho ótimo de potência ativa e reativa baseado na minimização do somatório dos desvios quadráticos da potência ativa fornecida pelos geradores, quando estes provêm reativos para o sistema, em relação à potência ativa gerada por estes mesmos geradores quando não precisam gerar reativos. Os desvios quadráticos são ponderados pelos preços marginais das barras, os quais dependem das ofertas dos geradores, e pela capacidade dos geradores. O modelo foi expresso como um problema do Fluxo de Potência Ótimo não-linear de dois níveis. Os objetivos deste trabalho são adaptar o modelo proposto por SENNA (2009) ao caso brasileiro, analisar os resultados obtidos através deste modelo e buscar uma forma alternativa de resolver o problema de otimização de dois níveis. Como técnica de solução, o problema do nível inferior foi modelado como um conjunto de restrições do problema de nível superior. Assim o problema binível tornou-se um problema de otimização de um único nível, que foi resolvido através do método primal-dual de pontos interiores utilizando as condições necessárias de Fritz-John (FJ) normalizadas. Foram feitas simulações para exemplos de 2 e 5 barras e para os sistemas de 30 e 118 barras do IEEE e os resultados numéricos obtidos mostram que a metodologia apresenta bom desempenho.<br> / Abstract : This work presents an optimal active and reactive power dispatch model based on the minimization of the sum of the square deviations of the active power provided by generators, when supplying reactive power, with respect to the active power generation when reactive power generation is not needed. The square deviations are weighted by the bus marginal prices, which depend on the offers made by the generators, and by the generator capacities. The model is expressed as a bilevel nonlinear optimal power flow problem. This bilevel problem is transformed into a single level problem by substituting the optimality conditions of the lower level problem into the upper level one. A normalized set of Fritz-John conditions is used to represent the optimal solutions of the single level problem, and the primal-dual interior point method is employed to obtain its solutions. Simulations were carried out with 2-bus and 5-bus examples, and also with the IEEE 30 and 118-bus test systems, indicating the good performance of the method.
197

Sistema fotovoltaico aplicado à irrigação de uma unidade agrícola de produção familiar / Photovoltaic powered irrigation system applied to familiary agriculture

Chilundo, Rosa Jacob 18 December 2014 (has links)
CHILUNDO, R. J. Sistema fotovoltaico aplicado à irrigação de uma unidade agrícola de produção familiar. 2014. 97 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-02-19T13:57:17Z No. of bitstreams: 1 2014_dis_rjchilundo.pdf: 4293522 bytes, checksum: a3bb57930423d2f15fcd5b5aded1941d (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-02-20T11:41:13Z (GMT) No. of bitstreams: 1 2014_dis_rjchilundo.pdf: 4293522 bytes, checksum: a3bb57930423d2f15fcd5b5aded1941d (MD5) / Made available in DSpace on 2015-02-20T11:41:13Z (GMT). No. of bitstreams: 1 2014_dis_rjchilundo.pdf: 4293522 bytes, checksum: a3bb57930423d2f15fcd5b5aded1941d (MD5) Previous issue date: 2014-12-18 / This thesis aims to analyze the technical and financial feasibility of a stand-alone photovoltaic system for irrigation applied to familiar unit production. The agricultural unit was installed in the Center for Teaching and Research in Urban Agriculture (NEPAU), which operates in partnership with the Alternative Energy Laboratory (LEA), located at the PICI campus of the Federal University of Ceará. The unit occupies a floor area of 43 m2, with a reservoir of water that simulates a pond, lake or well with capacity of 3534 liters, a pump motor of 12 VDC and a photovoltaic module of 135 Wp. The irrigation system is composed of 12 micro-sprinklers with 7 psi working pressure, with a range of 1.2 m radius and output of 0.6 l/min. The production plant consumed 31,592 liters of water and demanded 5.2 kWh of electrical energy throughout 44 days of production of coriander. A soil moisture sensor was used to control soil moisture allowing save 3608 liters of water and 0.6 kWh of electricity in the production of 23 kg of coriander. The costs for the photovoltaic pumping system was R$ 1,694.00. The efficiencies of photovoltaic module, pump and global set were 8.4%, 42% and 3.5%, respectively. The return on capital invested time is 10 years without regard to any allowance and 8.4 years for a 20% allowance on capital invested in the acquisition of equipment. / A presente dissertação tem como objetivo principal analisar a viabilidade técnica e financeira de um sistema fotovoltaico autônomo para bombeamento de água aplicado na irrigação de uma unidade de produção agrícola familiar. A unidade agrícola pesquisada está instalada no Núcleo de Ensino e Pesquisa em Agricultura Urbana (NEPAU), que atua em parceria com o Laboratório de Energias Alternativas (LEA), situados no Campus do PICI da Universidade Federal do Ceará. A unidade ocupa uma área útil de 43 m2, com um reservatório de água que simula um açude, lago ou poço com capacidade de 3.534 litros, um motor bomba de 12 VDC e um módulo fotovoltaico de 135 Wp. O sistema de irrigação é constituído por 12 micro-aspersores com pressão de trabalho de 7 psi, com raio de alcance de 1,2 m e vazão de 0,6 l/min. A unidade de produção consumiu 31.592 litros de água e demandou 5,2 kWh de energia elétrica ao longo de 44 dias de produção do coentro. Um sensor de umidade do solo foi utilizado para controlar a umidade do solo o que permitiu economizar 3.608 litros de água e 0,6 kWh de energia elétrica na produção de 23 kg de coentro. O custo de implantação do sistema fotovoltaico de bombeamento desenvolvido foi de R$ 1.694,00. As eficiências do módulo fotovoltaico, conjunto motobomba e global foram de 8,4%, 42% e 3,5%, respetivamente. O tempo de retorno do capital investido é de 10 anos sem considerar nenhum subsídio e de 8,4 anos para um subsídio de 20% sobre o capital investido na aquisição dos equipamentos.
198

Inversor de cinco níveis baseado na célula de comutação de múltiplos estados tipo T / Inverter five levels based on switching cell multi-state type T

Cacau, Ronny Glauber de Almeida 30 January 2014 (has links)
CACAU, R. G. A. Inversor de cinco níveis baseado na célula de comutação de múltiplos estados tipo T. 2014. 152 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-07-06T17:06:56Z No. of bitstreams: 1 2014_dis_rgacacau.pdf: 11821957 bytes, checksum: b7306b5e519472f4856a9aca099a33a0 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-07-22T16:18:48Z (GMT) No. of bitstreams: 1 2014_dis_rgacacau.pdf: 11821957 bytes, checksum: b7306b5e519472f4856a9aca099a33a0 (MD5) / Made available in DSpace on 2015-07-22T16:18:48Z (GMT). No. of bitstreams: 1 2014_dis_rgacacau.pdf: 11821957 bytes, checksum: b7306b5e519472f4856a9aca099a33a0 (MD5) Previous issue date: 2014-01-30 / This work presents the study, design and implementation of a multilevel converter based on T - type multi - state switching cell (5L - MSSC - T 2 ) for applications in low voltages and high currents. The proposed topology aims to extend the application of the multi - state switching cell (MSSC) to the structure of the three - level T - type converter, providing five levels in the output voltage before the filter and, consequently, a reduction of the harmonic content and higher output vol tage quality. Another feature of this topology is the uniform distribution of the total output current between the semiconductors of the converter, providing lower conduction losses and high efficiency. Furthermore , it is possible to reduce the weight and volume of magnetics, since the operating frequency of reactive elements is twice the switching frequency of the switches. A theoretical study with qualitative and quantitative analysis of the proposed inverter and the design methodology was performed . The control strategy implemented aims to control the output voltage and the DC bus voltages. The employed modulation technique is the conventional sinusoidal pulse width modulation (SPWM) . The validation of the topology is verified through simulation and exper imental results of a developed prototype for an output power of 5 kW / Este trabalho apresenta o estudo, projeto e implementação de um inversor multinível monofásico baseado na célula de comutação de múltiplos estados tipo T (5L-CCME-T2) para aplicações em baixa tensão e elevadas correntes. A topologia proposta visa estender a aplicação da célula de comutação de múltiplos estados (CCME) para a estrutura do conversor de três níveis tipo T, proporcionando cinco níveis na tensão de saída antes do filtro e, consequentemente, uma redução do conteúdo harmônico e maior qualidade da tensão de saída. Outra característica desta topologia é a distribuição uniforme da corrente total de saída entre os semicondutores do conversor, proporcionando menores perdas por condução e elevado rendimento. Além disso, é possível reduzir o peso e volume dos magnéticos, uma vez que a frequência de operação dos elementos reativos é o dobro da frequência de comutação dos interruptores. Um estudo teórico com análise qualitativa e quantitativa do inversor proposto e metodologia de projeto foi realizado. A estratégia de controle implementada tem como objetivo o controle da tensão de saída e das tensões do barramento CC. A técnica de modulação empregada é a convencional modulação por largura de pulso senoidal (SPWM). A validação da topologia é realizada através dos resultados de simulação e experimentais de um protótipo desenvolvido para uma potência de saída de 5 kW
199

Aplicação de ferramentas de inteligência computacional para previsão da velocidade do vento / Wind speed forecast using computacional intelligence tools

Bezerra, Erick Costa 01 1900 (has links)
BEZERRA, E. C. Aplicação de ferramentas de inteligência computacional para previsão da velocidade do vento. 2012. 127 f. Dissertação (Mestrado em em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-03-22T18:53:25Z No. of bitstreams: 1 2012_dis_ecbezerra.pdf: 23608008 bytes, checksum: 44e699b9603806222ce35ede1e2cc22d (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-03-22T18:53:59Z (GMT) No. of bitstreams: 1 2012_dis_ecbezerra.pdf: 23608008 bytes, checksum: 44e699b9603806222ce35ede1e2cc22d (MD5) / Made available in DSpace on 2012-03-22T18:53:59Z (GMT). No. of bitstreams: 1 2012_dis_ecbezerra.pdf: 23608008 bytes, checksum: 44e699b9603806222ce35ede1e2cc22d (MD5) Previous issue date: 2012-01 / Many countries have devoted a lot of attention in the use of renewable energy sources to ensure the growing of energy demand and sustainable development. Projections by the Global Wind Energy Council (GWEC) indicate that by 2015 the worldwide capacity of installed wind power will reach 449 GW, almost the double in 2010. The wind generation is characterized by the variability in production and the restricted control. The wind power forecast is essential for a reliable, safety and economic operation of power system. This paper presents and analyse the predicted wind velocity of Artificial Neural Networks (FTDNN, Elman, Jordan, NARX) to the forecasts horizons of 1h, 6h, 12h and 24h. Other Computacional Intelligence tools (PSO & GA) are used to improve the ANN performance. It was used as reference the results obtained through the Persistence model. It was used a time series with 45,658 measurement of wind speed, which 80% were selected for the training phase and 20% for validation purposes. As criteria for evaluate the performance of ANN were considered the error methods: MAE, RMSE and MAPE. The results shows that all the ANN ha similar results for 1h forecasts and better than the results from Persistence model. The use of PSO as a training tool results in better forecasts than the ones from backpropagation training. / Muitos países têm devotado elevada atenção ao uso de fontes renováveis para atender a demanda crescente de energia e assegurar um desenvolvimento sustentável. As projeções pelo Global Wind Energy Council (GWEC) indicam que até 2015 a capacidade mundial de potência eolielétrica instalada deverá chegar a 449 GW, o dobro existente em 2010. A geração eolielétrica tem como característica a variabilidade da produção e o controle restrito da geração, sendo a previsão da geração eólica uma necessidade para a operação confiável, segura e econômica dos sistemas de potência. Este trabalho apresenta e analisa o resultado da previsão da velocidade do vento utilizando Redes Neurais Artificiais (FTDNN, Elman, Jordan, e modelo Neural NARX) nos horizontes futuros de 1h, 6h, 12h e 24h. Outras ferramentas de Inteligência Computacional (PSO e GA) são também utilizadas para buscar melhorar o desempenho das RNAs na previsão. A análise comparativa das previsões obtidas teve como referência o modelo de Persistência. Os dados de velocidade do vento considerados provêm de uma série histórica com 45.658 amostras de medição, em que 80% foram selecionadas para a fase de treinamento e 20% para a validação. Como critério de avaliação do desempenho das Redes Neurais foram consideradas três medidas baseadas no erro da previsão (MAE, RMSE e MAPE). Para os dados utilizados, os modelos neurais testados se mostraram semelhantes (horizonte de 1h) e superiores (demais horizontes) ao modelo de Persistência, a depender do horizontes de previsão. Observou-se uma significativa melhoria das previsões dos modelos neurais ao adotar PSO como algoritmo de treinamento.
200

Estruturas de PLL (Phase-Locked Loop) monofásica e trifásica com alta rejeição a sub e inter-harmônicas / PLL (Phase-Locked Loop) structures for single phase and three phase systems with a high rejection capacity to sub and interharmonic

Araújo, Renato Guerreiro 18 November 2015 (has links)
ARAÚJO, R. G. Estruturas de PLL (Phase-Locked Loop) monofásica e trifásica com alta rejeição a sub e inter-harmônicas. 137 f. 2015. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-02-15T13:33:43Z No. of bitstreams: 1 2015_dis_rgaraujo.pdf: 4472806 bytes, checksum: e5fc0c7e779855fe380073eb2f4579f6 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-03-15T19:12:54Z (GMT) No. of bitstreams: 1 2015_dis_rgaraujo.pdf: 4472806 bytes, checksum: e5fc0c7e779855fe380073eb2f4579f6 (MD5) / Made available in DSpace on 2016-03-15T19:12:54Z (GMT). No. of bitstreams: 1 2015_dis_rgaraujo.pdf: 4472806 bytes, checksum: e5fc0c7e779855fe380073eb2f4579f6 (MD5) Previous issue date: 2015-11-18 / In applications related to power converters, such as inverters, rectifiers and the use of active filters, the synchronization method represent a very important element in the performance of the control strategy of this equipment. The estimated values of the synchronism angle, frequency and amplitude determined by the synchronization algorithms present, facing strongly distorted signals with the presence of sub and interharmonics, high errors. This study presents two algorithms: one applied on single-phase electrical systems and one applied on three-phase electrical systems, with high immunity to interharmonics and subharmonics. First are presented the main synchronization systems that are used in the electrical power systems. In addition, will be presented the main causes and consequences of the presence of subharmonics and interharmnics in the system, as well as the mathematical modeling of the two algorithms with high rejection to these disturbances. Will be presented the simulation and the experimental results of the proposed algorithms and the comparison between these synchronization methods with particular methods present in the literature. As a result of the study, it can be seen that the proposed structures present a higher response time, but the error of the estimated signal with respect the fundamental component of the input signal is lower when compared to structures such as EPLL and structures based on SOGI. It was observed that the proposed synchronization methods are enabled to estimate the synchronism angle, the frequency and the fundamental component of the input signal adequately and can be used in control strategies of power converters. / Em aplicações relacionadas à Eletrônica de Potência, como inversores, retificadores e a utilização de filtros ativos, o método de sincronização representa um elemento chave no desempenho da estratégia de controle destes equipamentos. Os valores do ângulo de sincronismo, frequência e amplitude estimados com determinados algoritmos de sincronização apresentam, diante de sinais fortemente distorcidos com a presença de sub e inter-harmônicos, erros elevados. Neste trabalho são apresentados dois algoritmos: um aplicado a sistemas elétricos monofásicos e outro aplicado a sistemas elétricos trifásicos, com elevada imunidade a inter-harmônicos e sub-harmônicos. Primeiramente são apresentados os principais sistemas de sincronização utilizados em sistemas elétricos de potência. Além disso, são apresentadas as principais causas e consequências da presença de sub-harmônicos e inter-harmônicos no sistema, bem como a modelagem matemática dos dois algoritmos com elevada rejeição a estes distúrbios. São apresentados os resultados de simulação e experimentais dos algoritmos propostos e a comparação entre estes métodos de sincronização com determinados métodos presentes na literatura. Como resultado do estudo, pode-se observar que as estruturas de sincronização propostas apresentam um tempo de resposta mais elevado, porém o erro do sinal estimado em relação a componente fundamental do sinal de entrada é inferior quando comparado a estruturas como o EPLL e estruturas baseadas no SOGI. Com isso, tem-se que as mesmas estão habilitadas para estimar o ângulo de sincronismo, a frequência e a componente fundamental do sinal de entrada adequadamente e podem serem utilizadas eficientemente em estratégias de controle de conversores de potência.

Page generated in 0.0905 seconds