Spelling suggestions: "subject:"ensaio doo como"" "subject:"ensaio ddo como""
1 |
Avaliação da Água do Rio Itapemirim/ Es: Aspectos Abióticos e Toxicogenéticos.GALTER, I. N. 29 June 2016 (has links)
Made available in DSpace on 2018-08-01T22:57:30Z (GMT). No. of bitstreams: 1
tese_9992_Dissertação Final Iasmini Nicoli Galter.pdf: 1550954 bytes, checksum: a6d8e258196e8da8c6c1302b52a2875d (MD5)
Previous issue date: 2016-06-29 / O rio Itapemirim é considerado um dos mais importantes recursos hídricos do Espírito Santo. Tento em vista a importância ecológica e socioeconômica deste recurso hídrico a preocupação com a qualidade da água é crucial, fazendo-se necessário a avaliação da água por abordagens que integrem os aspectos abióticos aos ensaios toxicogenéticos. Este trabalho teve como objetivo avaliar a qualidade da água do rio Itapemirim/ES, por meio de análise dos aspectos abióticos e toxicogenéticos, utilizando como organismo teste A. cepa, O. niloticus e cultura de célula de mamífero. Para tal, foram definidas 4 estações amostrais ao longo do percurso do rio Itapemirim/ES, nas quais foram realizadas amostragens de água em períodos de alta precipitação e estiagem. A partir das amostras foram avaliados a condutividade (μS/cm), temperatura da água (ºC), oxigênio dissolvido (mg/L) e pH, bem como quantificado a concentração de metais. Para o teste do A. cepa foram realizados o teste de crescimento radicular e análise citogenética. O ensaio com espécimes de O. niloticus envolveram teste do micronúcleo e ensaio do cometa. Já os bioensaios com células CHO-K1 foram os testes do MTT e ensaio do cometa. A maioria das variáveis abióticas avaliadas demostraram que as águas das duas campanhas, estão de acordo com a Resolução CONAMA nº 357/2005, assim como a maioria dos metais. Todavia, os índices de Al e Cu na água estavam acima do permito pela legislação. Pelos resultados obtidos, pode-se observar que os compostos presentes nas águas destes rios apresentam potencial fitotóxico, genotóxico e mutagênico para os dois organismos-teste in vivo e para o teste in vitro. Os resultados mais expressivos foram os obtidos da estação RI 03, provavelmente isto está relacionado ao fato dessa estação estar nas proximidades da região urbana do município de Cachoeiro de Itapemirim/ES. Notou-se também, que as duas campanhas realizadas apresentaram efeito negativo sobre os bioensaios realizados. Os dados encontrados neste estudo indicam que a qualidade da água do rio Itapemirim/ES encontra-se comprometida e alertam para os riscos que os despejos de efluentes domésticos e industriais apresentam sobre os corpos hídricos, principalmente pela complexa constituição química que apresentaram.
|
2 |
Análise e modelagem do comportamento colapsível de um solo arenoso / Analysis and modeling of the collapse behavior of a sandy soilDavies, Guilherme Izidório 31 July 2000 (has links)
Muitas são as pesquisas que avaliam as variáveis intervenientes no colapso dos solos: contudo, pouco tem sido publicado a respeito da influência da trajetória de ciclos de umedecimento e secagem, no comportamento colapsível do solo, e do colapso em condições de carregamento triaxial. O presente trabalho tem como objetivo estudar o colapso de um solo arenoso, típico da região centro-oeste do Estado de São Paulo, frente a tais variáveis através de ensaios edométricos convencionais, edométricos com controle de sucção e triaxiais. Dos ensaios edométricos convencionais caracterizou-se o colapso sob vários níveis de tensão, determinando assim a sobrecarga de inundação que causa máximo colapso. Nos ensaios de compressão triaxial, cada amostra foi inundada sob um determinado estado de tensão, caracterizado pela relação ▟/□. Nestes ensaios foi observado que as deformações volumétricas são dependentes da tensão confinante e da relação ▟/□, e que as deformações axiais por colapso são menores que as medidas nos ensaios edométricos convencionais. Nos ensaios edométricos com sucção controlada verificou-se que o valor inicial da sucção apresenta influência no valor do colapso total. Quanto aos ciclos de umedecimento e secagem, o solo sofreu colapso insignificante quando a sucção foi reduzida a um mesmo valor pela segunda vez. Os resultados experimentais dos ensaios edométricos com sucção controlada foram então modelados de acordo com o modelo de ALONSO et. al, (1990), e as adaptações a esse modelo propostas por FUTAI (1997) e MACHADO (1998), verificando-se a capacidade de cada formulação em representar matematicamente o comportamento colapsível do solo estudado. / There are many researches that evaluate and discuss the factors which interfere in the collapse of soils. However, not many have been published regarding the influence of the cycles of wetting in the collapsible behavior of the soil, and neither have collapse strains under triaxial load. The present work deals with the collapse behavior of a sandy soil, typical from the center-west of the State of São Paulo, considering the aforesaid aspects and using conventional oedometer, suction controlled oedometer and triaxial compression tests. In conventional oedometer tests, the influence of overburden stress on the induced wetting on collapse strains was characterized. Collapse strains were also measured in triaxial compression tests, varying the ratio of principal stress (▟/□) when the samples are inundated. It was observed that collapse volumetric strains are dependent on confining stress and on ▟/□, and that, axial and radial strains are related to the ratio of ▟/□. The axial collapse strains observed in triaxial compression tests were shown to be lower than the ones measured in conventional oedometer tests. In controlled suction tests, the amount of collapse strains under gradual suction reduction was studied including the influence of suction reversals. It was noted that the initial suction influences the amount of collapse strains, and that, in the cycles of wetting and drying, the strains after the second cycle tended to be negligible. Experimental results from suction controlled oedometer tests were modeled through the model by ALONSO et. al. (1990) and by the adaptations to this model proposed by FUTAI (1997) and MACHADO (1998).
|
3 |
Análise e modelagem do comportamento colapsível de um solo arenoso / Analysis and modeling of the collapse behavior of a sandy soilGuilherme Izidório Davies 31 July 2000 (has links)
Muitas são as pesquisas que avaliam as variáveis intervenientes no colapso dos solos: contudo, pouco tem sido publicado a respeito da influência da trajetória de ciclos de umedecimento e secagem, no comportamento colapsível do solo, e do colapso em condições de carregamento triaxial. O presente trabalho tem como objetivo estudar o colapso de um solo arenoso, típico da região centro-oeste do Estado de São Paulo, frente a tais variáveis através de ensaios edométricos convencionais, edométricos com controle de sucção e triaxiais. Dos ensaios edométricos convencionais caracterizou-se o colapso sob vários níveis de tensão, determinando assim a sobrecarga de inundação que causa máximo colapso. Nos ensaios de compressão triaxial, cada amostra foi inundada sob um determinado estado de tensão, caracterizado pela relação ▟/□. Nestes ensaios foi observado que as deformações volumétricas são dependentes da tensão confinante e da relação ▟/□, e que as deformações axiais por colapso são menores que as medidas nos ensaios edométricos convencionais. Nos ensaios edométricos com sucção controlada verificou-se que o valor inicial da sucção apresenta influência no valor do colapso total. Quanto aos ciclos de umedecimento e secagem, o solo sofreu colapso insignificante quando a sucção foi reduzida a um mesmo valor pela segunda vez. Os resultados experimentais dos ensaios edométricos com sucção controlada foram então modelados de acordo com o modelo de ALONSO et. al, (1990), e as adaptações a esse modelo propostas por FUTAI (1997) e MACHADO (1998), verificando-se a capacidade de cada formulação em representar matematicamente o comportamento colapsível do solo estudado. / There are many researches that evaluate and discuss the factors which interfere in the collapse of soils. However, not many have been published regarding the influence of the cycles of wetting in the collapsible behavior of the soil, and neither have collapse strains under triaxial load. The present work deals with the collapse behavior of a sandy soil, typical from the center-west of the State of São Paulo, considering the aforesaid aspects and using conventional oedometer, suction controlled oedometer and triaxial compression tests. In conventional oedometer tests, the influence of overburden stress on the induced wetting on collapse strains was characterized. Collapse strains were also measured in triaxial compression tests, varying the ratio of principal stress (▟/□) when the samples are inundated. It was observed that collapse volumetric strains are dependent on confining stress and on ▟/□, and that, axial and radial strains are related to the ratio of ▟/□. The axial collapse strains observed in triaxial compression tests were shown to be lower than the ones measured in conventional oedometer tests. In controlled suction tests, the amount of collapse strains under gradual suction reduction was studied including the influence of suction reversals. It was noted that the initial suction influences the amount of collapse strains, and that, in the cycles of wetting and drying, the strains after the second cycle tended to be negligible. Experimental results from suction controlled oedometer tests were modeled through the model by ALONSO et. al. (1990) and by the adaptations to this model proposed by FUTAI (1997) and MACHADO (1998).
|
Page generated in 0.0737 seconds