• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 614
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 617
  • 224
  • 211
  • 200
  • 147
  • 123
  • 109
  • 99
  • 79
  • 77
  • 73
  • 66
  • 61
  • 60
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Hipernatremia do doador como fator de risco para falência primária de enxerto após transplante cardíaco ortotópico / Hypernatremia of donor as a risk factor for primary graft failure after heart transplantation

Finger, Marco Aurelio 09 April 2013 (has links)
Introdução: O transplante cardíaco exerce um papel relevante no tratamento da insuficiência cardíaca grave. Dentro dos desfechos desfavoráveis a seus resultados, a falência primária do enxerto é reconhecida, como condição de gravidade e mortalidade elevada. Os fatores implicados no aparecimento da falência primária do enxerto ainda não são bem esclarecidos e sua relevância é pouco estudada. Objetivo: Observar se há associação entre hipernatremia do doador e de outras variáveis com o desenvolvimento da falência primária do enxerto (FPE). Métodos: Foram avaliados, retrospectivamente, 200 pacientes submetidos à cirurgia de Transplante Cardíaco Ortotópico (TxC) no Instituto Dante Pazzanese de Cardiologia (IDPC), no período entre 01/01/2001 e 31/12/2010, sendo cotado os níveis de sódio sérico no doador. Além disto, foram avaliados outros fatores relacionados ao doador, ao receptor e ao procedimento cirúrgico. Após a identificação de que o sódio sérico do doador estava elevado no grupo de receptores com FPE, um ponto de corte foi obtido pela curva ROC. O nível de significância dos testes foi de 5%. Um modelo de regressão logística múltipla foi ajustado para avaliar os efeitos de fatores e covariáveis presentes na FPE. Resultados: Entre os pacientes que desenvolveram falência primária do enxerto, a média do sódio sérico foi de 162,0 mEq/l contra 153,6 mEq/l dos que não apresentaram FPE. O valor de corte pela curva ROC foi de 159 mEq/l. Houve diferença significativa (p< 0,03) entre os dois grupos com aumento de ocorrência de falência primária do enxerto nos pacientes que receberam órgãos oriundos de doadores com sódio sérico >159mEq/l. A outra variável que apresentou valor significativo (p=0,04) foi o tabagismo do doador. Conclusão: Com base nesses achados, observou-se que existe associação entre a elevação do sódio sérico do doador com o desenvolvimento de falência primária do enxerto, após o transplante cardíaco. / Introduction: Cardiac transplantation has a role in the treatment of severe heart failure. Within the unfavorable outcomes to their results, the primary graft failure is recognized as a condition of severity and high mortality. The factors involved in the onset of primary graft failure are still unclear and their relevance is poorly studied. Objective: Observe if there is an association between donor hypernatremia and other variables with the development of primary graft failure (PGF). Methods: We retrospectively evaluated 200 patients who underwent surgery for orthotropic heart transplantation (HT) at the Instituto Dante Pazzanese de Cardiologia (IDPC) in the period between 01/01/2001 and 12/31/2010, and evaluated the serum sodium levels in the donor. Furthermore, we assessed other factors related to the donor, the recipient and the surgical procedure. After identification that the donor serum sodium was higher in the group of receivers with PGF, a cutoff point was obtained by ROC curve. The level of significance of the tests was 5%. A multiple logistic regression model was fitted to assess the effects of factors and covariates present in PGF. Results: Among patients who developed primary graft failure, the mean serum sodium was 162.0 mEq/l versus 153.6 mEq/l of which showed no PGF. The cutoff value for the ROC curve was 159 mEq/l. There was an important difference (p <0.03) between the two groups with increased incidence of primary graft failure in patients who received organs from donors with serum sodium> 159 mEq/l. The other variable that showed a significant value (p = 0.04) was smoking from the donor. Conclusion: Based on these findings, we observed that there is an association between elevated serum sodium from the donor with the development of primary graft failure after heart transplantation.
112

Enxerto corticoesponjoso homógeno processado quimicamente, esterilizado em óxido de etileno e embebido em medula óssea autógena. Estudo experimental em cães (Canis familiaris LINNAEUS, 1758) / Homogenous cortical-cancellous bone graft chemically processed, sterilized with ethylene oxide and soaked in autogenous bone marrow. An experimental study in dogs (Canis familiaris LINNAEUS, 1758).

Castania, Vitor Aparecido 04 May 2007 (has links)
Foi estudado experimentalmente o desempenho biológico de um tipo de enxerto ósseo homógeno, processado quimicamente, esterilizado em óxido de etileno e embebido em medula óssea autógena. De cães doadores adulto-jovens foram obtidos blocos cilíndricos de 1,0 x 1,0 cm da epífise distal do fêmur, com auxílio de uma trefina. Os ossos assim obtidos foram clareados, desengordurados, esterilizados em óxido de etileno e mantidos em estoque. Trinta cães adultos jovens foram usados como receptores do enxerto e foram alocados em dois grupos. No grupo I (experimental) os animais foram operados e, criado, transversalmente, com trefina de 1,0 cm de diâmetro externo, um espaço cilíndrico de 1,0 cm de diâmetro por 1,0 cm de altura na epífise distal do fêmur direito, onde foi encaixado o enxerto preparado e que foi previamente embebido em medula óssea do próprio animal retirada por punção óssea na crista ilíaca. Três semanas depois, o mesmo animal foi submetido ao mesmo procedimento cirúrgico no fêmur esquerdo. Os cães deste grupo foram sacrificados seis semanas após a primeira cirurgia. O grupo II constituiu o controle e foi formado por vinte cães adulto-jovens em que, primeiro, foi retirado um cilindro de osso da epífise distal do fêmur esquerdo e, em seguida, no mesmo tempo cirúrgico, foi criado o mesmo espaço no fêmur direito, com uma trefina de um centímetro de diâmetro interno e, então, encaixado o bloco de osso retirado do fêmur do outro lado do mesmo animal. Estes animais foram subdivididos em dois subgrupos de dez cães cada, em relação ao tempo de sacrifício. Em um subgrupo os cães foram sacrificados três semanas após, enquanto que, no outro subgrupo, foram sacrificados seis semanas após a cirurgia de implantação do enxerto. O processo de incorporação do enxerto foi avaliado pela histologia convencional e histologia de fluorescência óssea, pela injeção prévia de tetraciclina. A comparação foi entre os grupos I e II, nos períodos de três e seis semanas pós-implante. As áreas dos enxertos homógenos com 21 dias pós-implante, geralmente mostraram-se visíveis, na maioria das vezes, formadas por trabéculas finas irregulares, sem osteócitos, porém com áreas de neoformação óssea. Já os enxertos autógenos, a área do osso implantado era bem visível, com trabéculas de osso antigo, mais adelgaçadas, em menor número que o osso receptor, porém com intensa deposição de osso neoformado. Para os enxertos homógenos com 42 dias pós-implante, a área do enxerto estava bem definida e integrada ao osso adjacente, composta por trabéculas antigas com predomínio de osso neoformado sobre a superfície. Nos enxertos autógenos com 42 dias pós-implante, as trabéculas tinham orientação comum, com espaço intertrabecular preenchido por tecido conjuntivo denso, em algumas áreas, e por medula óssea madura em outras. O enxerto homógeno processado e esterilizado em óxido de etileno e embebido em medula óssea apresentou boa atividade biológica, embora, com integração mais lenta e menor desempenho em relação ao enxerto autógeno, o que o torna um bom substituto para este último. / In the present investigation the biological performance of the homogenous bone graft chemically processed, sterilized with ethylene oxide and soaked in autogenous bone marrow was investigated. Thirty dogs were assigned into two groups. In group I, ten young adult dogs received a cylindrical block of the above mentioned graft. Previously, the bone graft was immersed in autogenous bone marrow and then inserted in a cylindrical hole, with the same dimensions, created at the distal femoral epiphysis of the right femur. After three weeks the same animal was submitted to the same surgical procedure, but on the left femur. The animal was killed six weeks later. The group II was made up of twenty dogs that received an autogenous graft obtained from the left distal femur and implanted into the right distal femur (same shape, dimensions and technique). From this group, 10 dogs were killed three weeks later and 10 dogs were killed six weeks later. The graft incorporation was evaluated by light microscopy and fluorescence microscopy. Results showed that for 21 day implant in the homogenous group, there was osteogenesis at the periphery of the bone graft, but most of its trabeculae were still inviable. Conversely, for the autogenous grafts newly-formed bone was found on the trabecular surface, even in the inner parts of the implanted bone. At 42 days there was active osteogenesis in homogenous grafts with new bone deposition on the trabeculae but, in two cases, the graft was not incorporated (reabsorbed in one case and sequestred in the other one). The autogenous graft showed newly formed bone arranged in a well mature fashion with new bone marrow filling the intertrabecular gaps. It was concluded that the homogenous graft as prepared herein is a good alternative for autogenous grafts, although with a slower osteogenesis rate an less biological performance.
113

Estudo da viabilidade celular comparando os meios de conservação para enxerto ósseo de calota craniana: análise microscópica e imunoistoquímica em ratos

Tanaka, Fábio Yoshio [UNESP] 20 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-20Bitstream added on 2014-06-13T21:02:11Z : No. of bitstreams: 1 tanaka_fy_dr_araca.pdf: 1088210 bytes, checksum: 03e8b8b712b01bee40429585b8ec19b1 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo deste trabalho foi analisar a viabilidade celular comparando os meios de conservação para enxerto ósseo. A preservação de células viáveis em procedimentos de enxerto ósseo é de fundamental importância para que se tenha a osteogênese. Foram utilizados 43 ratos machos. Após a antissepsia do campo operatório foi realizada incisão linear na região mediana da calota craniana para obtenção do enxerto da região parietal direita e esquerda as quais foram removidas com auxílio de trefina de 5mm de diâmetro acoplada em micro-motor de baixa rotação, sob constante irrigação com solução de soro fisiológico 0,9% estéril. As peças do enxerto foram acondicionadas em tubos de ensaio estéreis os quais foram devidamente identificadas de acordo com o grupo e mantidas dentro deste tubo conforme cada condição do grupo. Como meio de conservação da viabilidade celular do enxerto foi utilizado o soro fisiológico a 0,9% (Grupo I) e a solução de Euro Collins® (Grupo II) e ainda para verificar se a temperatura tem influência direta na manutenção da viabilidade celular foi analisado o enxerto ósseo conservado em temperatura ambiente (Grupo III) e o enxerto ósseo sem nenhuma solução, porém mantido em gelo (GrupoIV). Para avaliar a viabilidade celular foi utilizada análise histológica e imunoistoquímica imediata e ainda em cada grupo analisou-se a viabilidade celular no período de 6 horas, 12 horas, 24 horas e 30 horas. Como resultado observou-se que a solução de Euro Collins® apresentou-se superior ao soro fisiológico no que se diz respeito à manutenção da viabilidade celular do enxerto ósseo onde se pode notar viabilidade celular até o período de 30 horas. / The aim of this study was to analyze cellular viability comparing storage media for skull vault bone graft. Preservation of viable cells in bone graft procedures is of paramount importance to obtain osteogenesis. Forty-three male used in this study. After antisepsis of the operative field, a linear incision was made on the middle region of the skull vault to obtain a bone graft from the right and left parietal areas. The grafts were removed with a 5-mm diameter trephine bur coupled to low-speed handpiece under continuous irrigation with sterile 0.9% saline. The graft pieces were placed in sterile 5-mL test tubes with caps, and were properly identified according to the group and maintained inside the test tubes as per each group conditions. The storage media evaluated for preservation of graft cellular viability were 0.9% saline (Group I) and Euro Collins® solution (Group II). In order to assess whether the temperature has a direct influence on the maintenance of cellular viability, the analysis was extended to bone grafts stored at room temperature (Group III) and bone grafts with no solution, but maintained in ice (Group IV). Cellular viability was evaluated by immediate histological and immunohistochemical analyses. For each group, cellular viability was analyzed at 6, 12, 24 and 30 hours after procedure. The results of this study showed that Euro Collins® solution yielded better performance than 0.9% saline as regards the maintenance of bone graft cellular viability (up to 30 hours).
114

Reparo ósseo após enxerto ósseo autógeno e implante de hidroxiapatita absorvível granulada sob influência de campo magnético estático : estudo experimental em calvária de ratos

Schwengber, Marcos Miguel Bechstedt January 2009 (has links)
Proposição: avaliar histológica e bioquimicamente o efeito de enxerto ósseo autógeno e implante de hidroxiapatita (HA) sintética (HAP 91®), sob influência de campo magnético estático, no reparo ósseo na calvária de ratos. Materiais e métodos: utilizaram-se defeitos críticos de 5 mm realizados na calvária de 60 ratos Wistar. Os animais foram submetidos a quatro diferentes intervenções: enxerto ósseo autógeno ou implante de HA, com e sem a presença de campo magnético estático, sepultado, com intensidade entre 40 e 70 G. Foi realizada análise histológica histométrica e descritiva dos defeitos ósseos em 15, 30 e 60 dias pós-operatórios. Realizou-se análise da atividade sistêmica da enzima fosfatase alcalina nos mesmos tempos operatórios. Para controle bioquímico utilizaram-se cinco animais (Naive). Resultados: o reparo ósseo foi mais acelerado no grupo de enxerto autógeno sob influência de campo magnetico do que no mesmo grupo sem influência magnética. O enxerto ósseo autógeno demonstrou reparo ósseo superior ao implante de HA. A atividade da enzima fosfatase alcalina teve sua maior expressividade em 30 dias pós-operatórios. Neste mesmo tempo operatório, os grupos com aplicação de campo magnético apresentaram atividade enzimática inferior aos grupos sem tal influência. Conclusões: o implante de HA demonstrou ser inferior ao enxerto ósseo autógeno no reparo ósseo. O campo magnético estático não causou influência sobre o reparo ósseo. A enzima fosfatase alcalina teve sua atividade diminuída em 30 dias pós-operatórios pela influência do campo magnético estático. / Purpose: to evaluate histologically and biochemically the effect of autogenous bone graft and synthetic hidroxiapatite (HA) implant (HAP 91®), under static magnetic field influence, on bone healing in rat calvaria. Materials e methods: 5-mm critical-size defects were created in each calvarium of 60 Wistar rats. They were submitted into four different interventions: autogenous bone graft or HA implant, with or without static magnetic field influence with intensity ranging from 40 to 70 G. Histometric and descriptive analysis of the bone defects were performed in 15, 30 and 60 days after surgery. At the same times, the systemic activity of alkalin phosphatase was measured. Five animals (Naive) were used as biochemical control. Results: bone healing was faster in the autogenous bone graft group under magnetic field stimulation than in the same group without the magnetic influence. The autogenous bone graft showed better results for bone healing than the HA implant. Alkalin phosphatase activity had its higher expression in 30 days after surgery. At this time the groups under magnetic stimulation had lower alkalin phosphatase activity than the groups without magnetic field influence. Conclusions: the HA implant showed worse bone healing than the autogenous bone graft. The static magnetic field did not cause any influence on bone healing. alkalin phosphatase had its activity lowered in 30 days after surgery in the groups under magnetic field influence.
115

Colágeno acelular e mucosa oral na substituição parcial da uretra: estudo comparativo em coelhos

Kawano, Paulo Roberto [UNESP] 27 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-27Bitstream added on 2014-06-13T20:26:08Z : No. of bitstreams: 1 kawano_pr_dr_botfm.pdf: 1275256 bytes, checksum: 842172d806ecc6bdc3b64de7b2144526 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A estenose uretral complexa, frequentemente, requer tecidos extragenitais para seu adequado tratamento. Estudos recentes têm sugerido, nestes casos, a utilização de um novo biomaterial à base de colágeno acelular derivado da submucosa intestinal suína (SIS). O objetivo deste estudo foi comparar os resultados da matriz de colágeno acelular (SIS) em uma ou quatro camadas à mucosa oral na substituição parcial da uretra em coelhos. Material e Métodos: Realizou-se um estudo prospectivo e randomizado utilizando-se 36 coelhos machos da raça North Folk divididos em 3 grupos. Os animais foram submetidos à ressecção padronizada da uretra ventral (segmento de 0,5 x 1 cm) que foi substituído por um enxerto tipo ilha de SIS com 1 camada no Grupo I (G1), SIS com 4 camadas no Grupo II (G2) e mucosa oral no Grupo III (G3). Nenhuma derivação urinária foi utilizada no pós-operatório. A uretrografia foi realizada no pré-operatório e antes do sacrifício. Os enxertos obtidos a partir da uretra regenerada foram avaliados 12 semanas após o implante por meio de exames histológicos de rotina. A retração do enxerto foi caracterizada objetivamente pelo cálculo matemático da área e pela análise computadorizada utilizando-se o software Scion Image®. A quantificação do colágeno foi obtida Resumo pela análise da coloração pelo Picrosirius red sob luz polarizada que permitiu a diferenciação das fibras de colágeno tipos I e III. Resultados: A uretrografia confirmou a manutenção de um calibre uretral adequado sem sinais de estenose. Fístulas uretrais foram diagnosticadas por meio de exame radiológico em 8,3% dos casos nos diferentes grupos (1 animal por grupo). A análise da área do enxerto pós-sacrifício pelos métodos matemático e computadorizado foi significativamente... / Several urethral conditions often require nongenital tissues for reconstruction. One collagen-based biomaterial that has recently emerged is small intestinal submucosa (SIS). The aim of our study was to compare the results between SIS and oral mucosa membrane in the partial substitution of the urethra in rabbits. Material and Methods: A prospective and randomized study was performed using 36 North Folk male rabbits divided into 3 equal groups. The animals were submitted to a ventral urethral defect (resection of 0,5 x 1 cm segment of the urethra) that was replaced by a patch graft of 1 layer SIS in group I (G1), 4 layers SIS in Group II (G2) and buccal mucosa in Group III (G3). No urethral catheter was left behind. Urethrography was performed pre-operatively and before sacrificing. The grafts of regenerated urethras were harvested at 12 weeks after implantation. The urethra was excised and evaluated by Hematoxylin and eosin stained sections. The patch retraction was objectively measured using mathematic calculation and Scion Image® computer analysis. The quantification of collagen was obtained by Picrosirius red analysis under polarized light. This technique allowed the differentiation of collagen fibers types I and III. Urethrograms confirmed the maintenance of a wide urethral caliber without any signs of strictures. Urethral fistulae was diagnosed by radiology in 8,3% of all groups (1 animal each group). Average graft shrinkage evaluated by computer analysis was significantly lower in G2 (p<0.05). The intensity of chronic inflammation, neovascularization, fibrosis and epithelium regeneration was similar among the three groups (p>0.05). The analysis of type III:I collagen index was higher in the animals of group II. Conclusions: The patch area analyzed by computer or mathematic method was smaller in group III (buccal mucosa) which showed a high percentage of retraction. Histological parameters were similar among the three groups.
116

Reparo ósseo após enxerto ósseo autógeno e implante de hidroxiapatita absorvível granulada sob influência de campo magnético estático : estudo experimental em calvária de ratos

Schwengber, Marcos Miguel Bechstedt January 2009 (has links)
Proposição: avaliar histológica e bioquimicamente o efeito de enxerto ósseo autógeno e implante de hidroxiapatita (HA) sintética (HAP 91®), sob influência de campo magnético estático, no reparo ósseo na calvária de ratos. Materiais e métodos: utilizaram-se defeitos críticos de 5 mm realizados na calvária de 60 ratos Wistar. Os animais foram submetidos a quatro diferentes intervenções: enxerto ósseo autógeno ou implante de HA, com e sem a presença de campo magnético estático, sepultado, com intensidade entre 40 e 70 G. Foi realizada análise histológica histométrica e descritiva dos defeitos ósseos em 15, 30 e 60 dias pós-operatórios. Realizou-se análise da atividade sistêmica da enzima fosfatase alcalina nos mesmos tempos operatórios. Para controle bioquímico utilizaram-se cinco animais (Naive). Resultados: o reparo ósseo foi mais acelerado no grupo de enxerto autógeno sob influência de campo magnetico do que no mesmo grupo sem influência magnética. O enxerto ósseo autógeno demonstrou reparo ósseo superior ao implante de HA. A atividade da enzima fosfatase alcalina teve sua maior expressividade em 30 dias pós-operatórios. Neste mesmo tempo operatório, os grupos com aplicação de campo magnético apresentaram atividade enzimática inferior aos grupos sem tal influência. Conclusões: o implante de HA demonstrou ser inferior ao enxerto ósseo autógeno no reparo ósseo. O campo magnético estático não causou influência sobre o reparo ósseo. A enzima fosfatase alcalina teve sua atividade diminuída em 30 dias pós-operatórios pela influência do campo magnético estático. / Purpose: to evaluate histologically and biochemically the effect of autogenous bone graft and synthetic hidroxiapatite (HA) implant (HAP 91®), under static magnetic field influence, on bone healing in rat calvaria. Materials e methods: 5-mm critical-size defects were created in each calvarium of 60 Wistar rats. They were submitted into four different interventions: autogenous bone graft or HA implant, with or without static magnetic field influence with intensity ranging from 40 to 70 G. Histometric and descriptive analysis of the bone defects were performed in 15, 30 and 60 days after surgery. At the same times, the systemic activity of alkalin phosphatase was measured. Five animals (Naive) were used as biochemical control. Results: bone healing was faster in the autogenous bone graft group under magnetic field stimulation than in the same group without the magnetic influence. The autogenous bone graft showed better results for bone healing than the HA implant. Alkalin phosphatase activity had its higher expression in 30 days after surgery. At this time the groups under magnetic stimulation had lower alkalin phosphatase activity than the groups without magnetic field influence. Conclusions: the HA implant showed worse bone healing than the autogenous bone graft. The static magnetic field did not cause any influence on bone healing. alkalin phosphatase had its activity lowered in 30 days after surgery in the groups under magnetic field influence.
117

Reparo ósseo após enxerto ósseo autógeno e implante de hidroxiapatita absorvível granulada sob influência de campo magnético estático : estudo experimental em calvária de ratos

Schwengber, Marcos Miguel Bechstedt January 2009 (has links)
Proposição: avaliar histológica e bioquimicamente o efeito de enxerto ósseo autógeno e implante de hidroxiapatita (HA) sintética (HAP 91®), sob influência de campo magnético estático, no reparo ósseo na calvária de ratos. Materiais e métodos: utilizaram-se defeitos críticos de 5 mm realizados na calvária de 60 ratos Wistar. Os animais foram submetidos a quatro diferentes intervenções: enxerto ósseo autógeno ou implante de HA, com e sem a presença de campo magnético estático, sepultado, com intensidade entre 40 e 70 G. Foi realizada análise histológica histométrica e descritiva dos defeitos ósseos em 15, 30 e 60 dias pós-operatórios. Realizou-se análise da atividade sistêmica da enzima fosfatase alcalina nos mesmos tempos operatórios. Para controle bioquímico utilizaram-se cinco animais (Naive). Resultados: o reparo ósseo foi mais acelerado no grupo de enxerto autógeno sob influência de campo magnetico do que no mesmo grupo sem influência magnética. O enxerto ósseo autógeno demonstrou reparo ósseo superior ao implante de HA. A atividade da enzima fosfatase alcalina teve sua maior expressividade em 30 dias pós-operatórios. Neste mesmo tempo operatório, os grupos com aplicação de campo magnético apresentaram atividade enzimática inferior aos grupos sem tal influência. Conclusões: o implante de HA demonstrou ser inferior ao enxerto ósseo autógeno no reparo ósseo. O campo magnético estático não causou influência sobre o reparo ósseo. A enzima fosfatase alcalina teve sua atividade diminuída em 30 dias pós-operatórios pela influência do campo magnético estático. / Purpose: to evaluate histologically and biochemically the effect of autogenous bone graft and synthetic hidroxiapatite (HA) implant (HAP 91®), under static magnetic field influence, on bone healing in rat calvaria. Materials e methods: 5-mm critical-size defects were created in each calvarium of 60 Wistar rats. They were submitted into four different interventions: autogenous bone graft or HA implant, with or without static magnetic field influence with intensity ranging from 40 to 70 G. Histometric and descriptive analysis of the bone defects were performed in 15, 30 and 60 days after surgery. At the same times, the systemic activity of alkalin phosphatase was measured. Five animals (Naive) were used as biochemical control. Results: bone healing was faster in the autogenous bone graft group under magnetic field stimulation than in the same group without the magnetic influence. The autogenous bone graft showed better results for bone healing than the HA implant. Alkalin phosphatase activity had its higher expression in 30 days after surgery. At this time the groups under magnetic stimulation had lower alkalin phosphatase activity than the groups without magnetic field influence. Conclusions: the HA implant showed worse bone healing than the autogenous bone graft. The static magnetic field did not cause any influence on bone healing. alkalin phosphatase had its activity lowered in 30 days after surgery in the groups under magnetic field influence.
118

Hipernatremia do doador como fator de risco para falência primária de enxerto após transplante cardíaco ortotópico / Hypernatremia of donor as a risk factor for primary graft failure after heart transplantation

Marco Aurelio Finger 09 April 2013 (has links)
Introdução: O transplante cardíaco exerce um papel relevante no tratamento da insuficiência cardíaca grave. Dentro dos desfechos desfavoráveis a seus resultados, a falência primária do enxerto é reconhecida, como condição de gravidade e mortalidade elevada. Os fatores implicados no aparecimento da falência primária do enxerto ainda não são bem esclarecidos e sua relevância é pouco estudada. Objetivo: Observar se há associação entre hipernatremia do doador e de outras variáveis com o desenvolvimento da falência primária do enxerto (FPE). Métodos: Foram avaliados, retrospectivamente, 200 pacientes submetidos à cirurgia de Transplante Cardíaco Ortotópico (TxC) no Instituto Dante Pazzanese de Cardiologia (IDPC), no período entre 01/01/2001 e 31/12/2010, sendo cotado os níveis de sódio sérico no doador. Além disto, foram avaliados outros fatores relacionados ao doador, ao receptor e ao procedimento cirúrgico. Após a identificação de que o sódio sérico do doador estava elevado no grupo de receptores com FPE, um ponto de corte foi obtido pela curva ROC. O nível de significância dos testes foi de 5%. Um modelo de regressão logística múltipla foi ajustado para avaliar os efeitos de fatores e covariáveis presentes na FPE. Resultados: Entre os pacientes que desenvolveram falência primária do enxerto, a média do sódio sérico foi de 162,0 mEq/l contra 153,6 mEq/l dos que não apresentaram FPE. O valor de corte pela curva ROC foi de 159 mEq/l. Houve diferença significativa (p< 0,03) entre os dois grupos com aumento de ocorrência de falência primária do enxerto nos pacientes que receberam órgãos oriundos de doadores com sódio sérico >159mEq/l. A outra variável que apresentou valor significativo (p=0,04) foi o tabagismo do doador. Conclusão: Com base nesses achados, observou-se que existe associação entre a elevação do sódio sérico do doador com o desenvolvimento de falência primária do enxerto, após o transplante cardíaco. / Introduction: Cardiac transplantation has a role in the treatment of severe heart failure. Within the unfavorable outcomes to their results, the primary graft failure is recognized as a condition of severity and high mortality. The factors involved in the onset of primary graft failure are still unclear and their relevance is poorly studied. Objective: Observe if there is an association between donor hypernatremia and other variables with the development of primary graft failure (PGF). Methods: We retrospectively evaluated 200 patients who underwent surgery for orthotropic heart transplantation (HT) at the Instituto Dante Pazzanese de Cardiologia (IDPC) in the period between 01/01/2001 and 12/31/2010, and evaluated the serum sodium levels in the donor. Furthermore, we assessed other factors related to the donor, the recipient and the surgical procedure. After identification that the donor serum sodium was higher in the group of receivers with PGF, a cutoff point was obtained by ROC curve. The level of significance of the tests was 5%. A multiple logistic regression model was fitted to assess the effects of factors and covariates present in PGF. Results: Among patients who developed primary graft failure, the mean serum sodium was 162.0 mEq/l versus 153.6 mEq/l of which showed no PGF. The cutoff value for the ROC curve was 159 mEq/l. There was an important difference (p <0.03) between the two groups with increased incidence of primary graft failure in patients who received organs from donors with serum sodium> 159 mEq/l. The other variable that showed a significant value (p = 0.04) was smoking from the donor. Conclusion: Based on these findings, we observed that there is an association between elevated serum sodium from the donor with the development of primary graft failure after heart transplantation.
119

Enxerto corticoesponjoso homógeno processado quimicamente, esterilizado em óxido de etileno e embebido em medula óssea autógena. Estudo experimental em cães (Canis familiaris LINNAEUS, 1758) / Homogenous cortical-cancellous bone graft chemically processed, sterilized with ethylene oxide and soaked in autogenous bone marrow. An experimental study in dogs (Canis familiaris LINNAEUS, 1758).

Vitor Aparecido Castania 04 May 2007 (has links)
Foi estudado experimentalmente o desempenho biológico de um tipo de enxerto ósseo homógeno, processado quimicamente, esterilizado em óxido de etileno e embebido em medula óssea autógena. De cães doadores adulto-jovens foram obtidos blocos cilíndricos de 1,0 x 1,0 cm da epífise distal do fêmur, com auxílio de uma trefina. Os ossos assim obtidos foram clareados, desengordurados, esterilizados em óxido de etileno e mantidos em estoque. Trinta cães adultos jovens foram usados como receptores do enxerto e foram alocados em dois grupos. No grupo I (experimental) os animais foram operados e, criado, transversalmente, com trefina de 1,0 cm de diâmetro externo, um espaço cilíndrico de 1,0 cm de diâmetro por 1,0 cm de altura na epífise distal do fêmur direito, onde foi encaixado o enxerto preparado e que foi previamente embebido em medula óssea do próprio animal retirada por punção óssea na crista ilíaca. Três semanas depois, o mesmo animal foi submetido ao mesmo procedimento cirúrgico no fêmur esquerdo. Os cães deste grupo foram sacrificados seis semanas após a primeira cirurgia. O grupo II constituiu o controle e foi formado por vinte cães adulto-jovens em que, primeiro, foi retirado um cilindro de osso da epífise distal do fêmur esquerdo e, em seguida, no mesmo tempo cirúrgico, foi criado o mesmo espaço no fêmur direito, com uma trefina de um centímetro de diâmetro interno e, então, encaixado o bloco de osso retirado do fêmur do outro lado do mesmo animal. Estes animais foram subdivididos em dois subgrupos de dez cães cada, em relação ao tempo de sacrifício. Em um subgrupo os cães foram sacrificados três semanas após, enquanto que, no outro subgrupo, foram sacrificados seis semanas após a cirurgia de implantação do enxerto. O processo de incorporação do enxerto foi avaliado pela histologia convencional e histologia de fluorescência óssea, pela injeção prévia de tetraciclina. A comparação foi entre os grupos I e II, nos períodos de três e seis semanas pós-implante. As áreas dos enxertos homógenos com 21 dias pós-implante, geralmente mostraram-se visíveis, na maioria das vezes, formadas por trabéculas finas irregulares, sem osteócitos, porém com áreas de neoformação óssea. Já os enxertos autógenos, a área do osso implantado era bem visível, com trabéculas de osso antigo, mais adelgaçadas, em menor número que o osso receptor, porém com intensa deposição de osso neoformado. Para os enxertos homógenos com 42 dias pós-implante, a área do enxerto estava bem definida e integrada ao osso adjacente, composta por trabéculas antigas com predomínio de osso neoformado sobre a superfície. Nos enxertos autógenos com 42 dias pós-implante, as trabéculas tinham orientação comum, com espaço intertrabecular preenchido por tecido conjuntivo denso, em algumas áreas, e por medula óssea madura em outras. O enxerto homógeno processado e esterilizado em óxido de etileno e embebido em medula óssea apresentou boa atividade biológica, embora, com integração mais lenta e menor desempenho em relação ao enxerto autógeno, o que o torna um bom substituto para este último. / In the present investigation the biological performance of the homogenous bone graft chemically processed, sterilized with ethylene oxide and soaked in autogenous bone marrow was investigated. Thirty dogs were assigned into two groups. In group I, ten young adult dogs received a cylindrical block of the above mentioned graft. Previously, the bone graft was immersed in autogenous bone marrow and then inserted in a cylindrical hole, with the same dimensions, created at the distal femoral epiphysis of the right femur. After three weeks the same animal was submitted to the same surgical procedure, but on the left femur. The animal was killed six weeks later. The group II was made up of twenty dogs that received an autogenous graft obtained from the left distal femur and implanted into the right distal femur (same shape, dimensions and technique). From this group, 10 dogs were killed three weeks later and 10 dogs were killed six weeks later. The graft incorporation was evaluated by light microscopy and fluorescence microscopy. Results showed that for 21 day implant in the homogenous group, there was osteogenesis at the periphery of the bone graft, but most of its trabeculae were still inviable. Conversely, for the autogenous grafts newly-formed bone was found on the trabecular surface, even in the inner parts of the implanted bone. At 42 days there was active osteogenesis in homogenous grafts with new bone deposition on the trabeculae but, in two cases, the graft was not incorporated (reabsorbed in one case and sequestred in the other one). The autogenous graft showed newly formed bone arranged in a well mature fashion with new bone marrow filling the intertrabecular gaps. It was concluded that the homogenous graft as prepared herein is a good alternative for autogenous grafts, although with a slower osteogenesis rate an less biological performance.
120

Estudo comparativo de duas técnicas de enxerto autógeno utilizando piezocirurgia para levantamento de seio maxilar / Comparative study of two autogenous graft techniques using piezosurgery for sinus lifting

Camargo Filho, Geraldo Prestes de 28 May 2010 (has links)
A técnica de levantamento de seio maxilar apresenta como uma possível complicação a perfuração da membrana sinusal. A utilização de dispositivos ultrassônicos apresenta-se como uma interessante ferramenta, particularmente segura e eficiente para realização das ostectomias de parede sinusal e divulsão de membrana sinusal. O presente trabalho teve por objetivo comparar duas técnicas que utilizam a cirurgia ultrassônica para realização de enxerto autógeno para levantamento de seio maxilar. Dez coelhos foram utilizados no estudo, sendo que um deles não foi submetido a procedimento cirúrgico. Os nove coelhos operados tiveram os seios maxilares preenchidos com enxertos autógenos coletados de díploe externa de calota craniana, nas formas particulado do lado direito e raspado do lado esquerdo, ambos com aparelho ultrassônico. Os dados de densidade óssea nos seios maxilares esquerdo e direito, obtidos por meio de tomografia computadorizada nos sentidos transversal e longitudinal, registrados 90 dias após a realização dos enxertos foram comparados estatisticamente. Cortes histológicos das áreas enxertadas foram realizados com finalidade descritiva. Não houve diferenças estatisticamente significantes entre as técnicas de enxerto que utilizaram osso raspado e particulado coletado por meio de dispositivo ultrassônico da calota craniana de coelhos. O aspecto histológico observado após 90 dias foi semelhante nos dois grupos, mostrando tecido ósseo maduro em meio a tecido conjuntivo frouxo. Os procedimentos transoperatórios nos levaram a concluir que o ultrassom piezoelétrico mostrou-se um instrumento seguro na abordagem cirúrgica do seio maxilar de coelhos, permitindo a manutenção da integridade da membrana sinusal durante as manobras cirúrgicas. / Maxillary sinus lifting is a technique which presents as a possible complication the sinus membrane perforation. The use of ultrasonic devices is presented as an interesting tool, particularly safe and efficient to perform ostectomies of sinus wall and dissection of sinus membrane. This study aimed to compare two techniques that used ultrasound surgery to perform autogenous graft for maxillary sinus lifting. Ten rabbits were used in the study, one of which did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were compared statistically. Histological sections of the grafted areas were performed with descriptive purposes. There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device of the skull of rabbits. Histological aspects after 90 days were similar in both groups, showing mature bone through a fibrous connective tissue. Operatory assessment procedures leads us to conclude that the piezoelectric ultrasound showed as a safe tool in the surgical approach of the maxillary sinus of rabbits, allowing the maintenance of sinus membrane integrity during surgical procedures.

Page generated in 0.0781 seconds