• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportamento de misturas solo-cimento-fibra sob compressão confinada com medição de tensão lateral

Santos, Ana Paula Silva dos January 2004 (has links)
Nesta dissertação desenvolve-se um equipamento de compressão confinada com medição de tensão lateral e avalia-se o comportamento, sobre a trajetória de tensões Ko, de um solo e de misturas de solo-fibra e solo-cimento, considerando a influência da adição de fibras de diferentes comprimentos e de cimento em variadas quantidades ao solo estudado bem como o efeito da tensão de cura e índice de vazios de cura na trajetória de tensões Ko, na tensão lateral, nas deformações verticais e nos valores de Ko. O solo utilizado no estudo é uma areia fina de granulometria uniforme extraída de uma jazida localizada no município de Osório – RS. O trabalho de pesquisa realizado com esses solos tem seu enfoque dividido em duas partes principais: (1) projeto, construção, validação e calibração do equipamento; (2) ensaios de compressão confinada com medição de tensão lateral em amostras de solocimento- fibra com dois comprimentos de fibras (6mm e 12 mm), três teores de cimento (1%, 3% e 7%) e em três diferentes condições de cura (cura sob tensão vertical de 0 kPa, cura sob tensão vertical de 0 kPa com índice de vazios modificado pela aplicação anterior à cura de uma tensão vertical de 500 kPa e cura sob tensão vertical de 500 kPa). Os níveis de tensões aplicados neste trabalho chegam a 3000 kPa. Os resultados mostram que o equipamento de compressão confinada com medição de tensões laterais funciona satisfatoriamente, apresentando dados coerentes e confiáveis A inclusão de fibras, bem como o aumento do comprimento das mesmas, diminui os valores de tensão lateral e de Ko em relação ao material sem reforço. A presença de cimento reduz a tensão lateral e gera uma tensão lateral residual, a qual aumenta com o teor de cimento. Da mesma forma, um acréscimo na rigidez ocorre com o aumento da quantidade de cimento. O efeito da cimentação diminui os valores de Ko e os tornam não mais constantes no carregamento. A alteração das condições de cura não causa mudanças significativas no que diz respeito às tensões, mas a rigidez inicial é aumentada com a mudança do índice de vazios e da tensão de cura dos materiais cimentados, sendo o acréscimo maior para a segunda.
2

Desenvolvimento de equipamento para ensaios simple shear

Perazzolo, Lilian January 2008 (has links)
Esta tese de doutorado apresenta o desenvolvimento de um equipamento de ensaios de laboratório do tipo simple shear, montado no Laboratório de Geotecnologia da Universidade Federal do Rio Grande do Sul (LAGEO/UFRGS). Neste trabalho é apresentada a revisão bibliográfica que embasou o projeto do equipamento simple shear. O projeto completo deste equipamento é apresentado no Anexo I. No texto são comentadas as características especiais deste equipamento e a aplicabilidade do ensaio simple shear, além dos procedimentos utilizados nos ensaios simple shear. Dois solos arenosos foram selecionados para ensaio neste equipamento; são feitas considerações sobre parâmetros de resistência ao cisalhamento e de deformabilidade de solos arenosos, e é apresentada uma caracterização destes materiais. Em seguida são apresentados os resultados dos ensaios simple shear realizados nos dois solos, denominados de Areia Clara e Areia Escura. Foram realizados nestes solos ensaios simple shear drenados em corpos de prova secos e inundados. Os resultados dos ensaios simple shear foram discutidos e comparados com resultados de ensaios de cisalhamento direto e triaxial, previamente realizados nos mesmos solos. A comparação entre os parâmetros de resistência ao cisalhamento obtidos com resultados destes ensaios mostrou valores similares entre os ensaios de cisalhamento direto e simple shear, entretanto, a comparação com os ensaios triaxiais apresentou maiores diferenças. / This doctoral thesis presents the development of a simple shear laboratory testing equipment. This equipment was built in the Geotechnology Laboratory of Federal University of Rio Grande do Sul (LAGEO/UFRGS). This work presents a literature review about simple shear equipments, which was the basis for the design. The full design of this equipment is shown in Annex I. The special features of this device are commented in the text, together with the applicability of the test and testing procedures. Some considerations about shear strength and the deformability parameters of sandy soils have been made. Two sandy soils, named Light Sand and Dark Sand, are then described. Results of simple shear tests performed with both sandy soils are shown and compared with results of other tests, such as triaxial and direct shear tests, performed with the same soils. With regard to shear strength, the results of simple shear tests in comparison with the results of direct shear tests are similar. However, the same comparison with de triaxial results showed larger disparity.
3

Desenvolvimento de equipamento para ensaios simple shear

Perazzolo, Lilian January 2008 (has links)
Esta tese de doutorado apresenta o desenvolvimento de um equipamento de ensaios de laboratório do tipo simple shear, montado no Laboratório de Geotecnologia da Universidade Federal do Rio Grande do Sul (LAGEO/UFRGS). Neste trabalho é apresentada a revisão bibliográfica que embasou o projeto do equipamento simple shear. O projeto completo deste equipamento é apresentado no Anexo I. No texto são comentadas as características especiais deste equipamento e a aplicabilidade do ensaio simple shear, além dos procedimentos utilizados nos ensaios simple shear. Dois solos arenosos foram selecionados para ensaio neste equipamento; são feitas considerações sobre parâmetros de resistência ao cisalhamento e de deformabilidade de solos arenosos, e é apresentada uma caracterização destes materiais. Em seguida são apresentados os resultados dos ensaios simple shear realizados nos dois solos, denominados de Areia Clara e Areia Escura. Foram realizados nestes solos ensaios simple shear drenados em corpos de prova secos e inundados. Os resultados dos ensaios simple shear foram discutidos e comparados com resultados de ensaios de cisalhamento direto e triaxial, previamente realizados nos mesmos solos. A comparação entre os parâmetros de resistência ao cisalhamento obtidos com resultados destes ensaios mostrou valores similares entre os ensaios de cisalhamento direto e simple shear, entretanto, a comparação com os ensaios triaxiais apresentou maiores diferenças. / This doctoral thesis presents the development of a simple shear laboratory testing equipment. This equipment was built in the Geotechnology Laboratory of Federal University of Rio Grande do Sul (LAGEO/UFRGS). This work presents a literature review about simple shear equipments, which was the basis for the design. The full design of this equipment is shown in Annex I. The special features of this device are commented in the text, together with the applicability of the test and testing procedures. Some considerations about shear strength and the deformability parameters of sandy soils have been made. Two sandy soils, named Light Sand and Dark Sand, are then described. Results of simple shear tests performed with both sandy soils are shown and compared with results of other tests, such as triaxial and direct shear tests, performed with the same soils. With regard to shear strength, the results of simple shear tests in comparison with the results of direct shear tests are similar. However, the same comparison with de triaxial results showed larger disparity.
4

Comportamento de misturas solo-cimento-fibra sob compressão confinada com medição de tensão lateral

Santos, Ana Paula Silva dos January 2004 (has links)
Nesta dissertação desenvolve-se um equipamento de compressão confinada com medição de tensão lateral e avalia-se o comportamento, sobre a trajetória de tensões Ko, de um solo e de misturas de solo-fibra e solo-cimento, considerando a influência da adição de fibras de diferentes comprimentos e de cimento em variadas quantidades ao solo estudado bem como o efeito da tensão de cura e índice de vazios de cura na trajetória de tensões Ko, na tensão lateral, nas deformações verticais e nos valores de Ko. O solo utilizado no estudo é uma areia fina de granulometria uniforme extraída de uma jazida localizada no município de Osório – RS. O trabalho de pesquisa realizado com esses solos tem seu enfoque dividido em duas partes principais: (1) projeto, construção, validação e calibração do equipamento; (2) ensaios de compressão confinada com medição de tensão lateral em amostras de solocimento- fibra com dois comprimentos de fibras (6mm e 12 mm), três teores de cimento (1%, 3% e 7%) e em três diferentes condições de cura (cura sob tensão vertical de 0 kPa, cura sob tensão vertical de 0 kPa com índice de vazios modificado pela aplicação anterior à cura de uma tensão vertical de 500 kPa e cura sob tensão vertical de 500 kPa). Os níveis de tensões aplicados neste trabalho chegam a 3000 kPa. Os resultados mostram que o equipamento de compressão confinada com medição de tensões laterais funciona satisfatoriamente, apresentando dados coerentes e confiáveis A inclusão de fibras, bem como o aumento do comprimento das mesmas, diminui os valores de tensão lateral e de Ko em relação ao material sem reforço. A presença de cimento reduz a tensão lateral e gera uma tensão lateral residual, a qual aumenta com o teor de cimento. Da mesma forma, um acréscimo na rigidez ocorre com o aumento da quantidade de cimento. O efeito da cimentação diminui os valores de Ko e os tornam não mais constantes no carregamento. A alteração das condições de cura não causa mudanças significativas no que diz respeito às tensões, mas a rigidez inicial é aumentada com a mudança do índice de vazios e da tensão de cura dos materiais cimentados, sendo o acréscimo maior para a segunda.
5

Desenvolvimento de equipamento para ensaios simple shear

Perazzolo, Lilian January 2008 (has links)
Esta tese de doutorado apresenta o desenvolvimento de um equipamento de ensaios de laboratório do tipo simple shear, montado no Laboratório de Geotecnologia da Universidade Federal do Rio Grande do Sul (LAGEO/UFRGS). Neste trabalho é apresentada a revisão bibliográfica que embasou o projeto do equipamento simple shear. O projeto completo deste equipamento é apresentado no Anexo I. No texto são comentadas as características especiais deste equipamento e a aplicabilidade do ensaio simple shear, além dos procedimentos utilizados nos ensaios simple shear. Dois solos arenosos foram selecionados para ensaio neste equipamento; são feitas considerações sobre parâmetros de resistência ao cisalhamento e de deformabilidade de solos arenosos, e é apresentada uma caracterização destes materiais. Em seguida são apresentados os resultados dos ensaios simple shear realizados nos dois solos, denominados de Areia Clara e Areia Escura. Foram realizados nestes solos ensaios simple shear drenados em corpos de prova secos e inundados. Os resultados dos ensaios simple shear foram discutidos e comparados com resultados de ensaios de cisalhamento direto e triaxial, previamente realizados nos mesmos solos. A comparação entre os parâmetros de resistência ao cisalhamento obtidos com resultados destes ensaios mostrou valores similares entre os ensaios de cisalhamento direto e simple shear, entretanto, a comparação com os ensaios triaxiais apresentou maiores diferenças. / This doctoral thesis presents the development of a simple shear laboratory testing equipment. This equipment was built in the Geotechnology Laboratory of Federal University of Rio Grande do Sul (LAGEO/UFRGS). This work presents a literature review about simple shear equipments, which was the basis for the design. The full design of this equipment is shown in Annex I. The special features of this device are commented in the text, together with the applicability of the test and testing procedures. Some considerations about shear strength and the deformability parameters of sandy soils have been made. Two sandy soils, named Light Sand and Dark Sand, are then described. Results of simple shear tests performed with both sandy soils are shown and compared with results of other tests, such as triaxial and direct shear tests, performed with the same soils. With regard to shear strength, the results of simple shear tests in comparison with the results of direct shear tests are similar. However, the same comparison with de triaxial results showed larger disparity.
6

Comportamento de misturas solo-cimento-fibra sob compressão confinada com medição de tensão lateral

Santos, Ana Paula Silva dos January 2004 (has links)
Nesta dissertação desenvolve-se um equipamento de compressão confinada com medição de tensão lateral e avalia-se o comportamento, sobre a trajetória de tensões Ko, de um solo e de misturas de solo-fibra e solo-cimento, considerando a influência da adição de fibras de diferentes comprimentos e de cimento em variadas quantidades ao solo estudado bem como o efeito da tensão de cura e índice de vazios de cura na trajetória de tensões Ko, na tensão lateral, nas deformações verticais e nos valores de Ko. O solo utilizado no estudo é uma areia fina de granulometria uniforme extraída de uma jazida localizada no município de Osório – RS. O trabalho de pesquisa realizado com esses solos tem seu enfoque dividido em duas partes principais: (1) projeto, construção, validação e calibração do equipamento; (2) ensaios de compressão confinada com medição de tensão lateral em amostras de solocimento- fibra com dois comprimentos de fibras (6mm e 12 mm), três teores de cimento (1%, 3% e 7%) e em três diferentes condições de cura (cura sob tensão vertical de 0 kPa, cura sob tensão vertical de 0 kPa com índice de vazios modificado pela aplicação anterior à cura de uma tensão vertical de 500 kPa e cura sob tensão vertical de 500 kPa). Os níveis de tensões aplicados neste trabalho chegam a 3000 kPa. Os resultados mostram que o equipamento de compressão confinada com medição de tensões laterais funciona satisfatoriamente, apresentando dados coerentes e confiáveis A inclusão de fibras, bem como o aumento do comprimento das mesmas, diminui os valores de tensão lateral e de Ko em relação ao material sem reforço. A presença de cimento reduz a tensão lateral e gera uma tensão lateral residual, a qual aumenta com o teor de cimento. Da mesma forma, um acréscimo na rigidez ocorre com o aumento da quantidade de cimento. O efeito da cimentação diminui os valores de Ko e os tornam não mais constantes no carregamento. A alteração das condições de cura não causa mudanças significativas no que diz respeito às tensões, mas a rigidez inicial é aumentada com a mudança do índice de vazios e da tensão de cura dos materiais cimentados, sendo o acréscimo maior para a segunda.
7

Equipamento compacto para o tratamento de águas subterrâneas contaminadas por BTEX e TPH

Caetano, Marcelo Oliveira January 2014 (has links)
O objetivo desta tese foi o desenvolvimento de um equipamento compacto para o tratamento de águas subterrâneas contaminadas por BTEX e TPH em postos de combustíveis. Esta questão ambiental é uma preocupação mundial devido ao nível de contaminação e a quantidade de vazamentos existentes, toxicidade dos poluentes e a necessidade de uso de aquíferos para consumo humano. O equipamento é composto por unidades que contemplam as seguintes etapas: (a) sucção e volatilização de compostos orgânicos voláteis; (b) injeção de ar (“air sparging”) para remoção de substâncias orgânicas voláteis; e (c) filtro de adsorção com recheio composto por mistura de 50% de carvão ativado e 50% de cinza de casca de arroz para a remoção de TPH. A parte experimental envolveu a caracterização de águas subterrâneas contaminadas e estudos em escala piloto e real. Os resultados obtidos demostraram que o equipamento de remediação desenvolvido é altamente eficiente para o tratamento de águas subterrâneas contaminadas. Com um tempo de detenção de 8 horas, obtiveram-se decréscimos superiores a 96% de BTEX e TPH. Nesta situação, a água contaminada tratada alcança valores que atendem aos critérios de lançamento estabelecidos pelas legislação nacional vigente. / This study describes the development of a compact device to treat groundwater contaminated with BTEX and TPH in gas stations. This environmental issue raises concerns worldwide, due to the level of contamination, the high occurrence of leaks, the toxicity of contaminants, and the importance of aquifers for human consumption. The equipment was formed by: a) a suction and treatment stage using vacuum and aeration with injectors (to replace the suction system based on a conventional vacuum pump and the air stripping and/or air sparging system); b) small-scale surface aerators (to replace the air stripping and/or air sparging system); c) an adsorption filter using a mixture of activated carbon (50%) and rice husk ash (50%) (to replace the activated carbon system). The experiment was conducted in four stages: a) characterization of groundwaters; b) presentation of the adsorbents used in the filter; c) pilot test (under controlled conditions to measure the efficiency to remove BTEX and TPH); and d) the full-scale tests (observation and confirmation of equipment efficiency). The results show that the remediation equipment developed is highly efficient to treat contaminated groundwater. An 8-h retention time afforded to reduce BTEX and TPH levels by over 96%. In this scenario, the treated water parameters meet the current legal requirements for discharge.
8

Equipamento compacto para o tratamento de águas subterrâneas contaminadas por BTEX e TPH

Caetano, Marcelo Oliveira January 2014 (has links)
O objetivo desta tese foi o desenvolvimento de um equipamento compacto para o tratamento de águas subterrâneas contaminadas por BTEX e TPH em postos de combustíveis. Esta questão ambiental é uma preocupação mundial devido ao nível de contaminação e a quantidade de vazamentos existentes, toxicidade dos poluentes e a necessidade de uso de aquíferos para consumo humano. O equipamento é composto por unidades que contemplam as seguintes etapas: (a) sucção e volatilização de compostos orgânicos voláteis; (b) injeção de ar (“air sparging”) para remoção de substâncias orgânicas voláteis; e (c) filtro de adsorção com recheio composto por mistura de 50% de carvão ativado e 50% de cinza de casca de arroz para a remoção de TPH. A parte experimental envolveu a caracterização de águas subterrâneas contaminadas e estudos em escala piloto e real. Os resultados obtidos demostraram que o equipamento de remediação desenvolvido é altamente eficiente para o tratamento de águas subterrâneas contaminadas. Com um tempo de detenção de 8 horas, obtiveram-se decréscimos superiores a 96% de BTEX e TPH. Nesta situação, a água contaminada tratada alcança valores que atendem aos critérios de lançamento estabelecidos pelas legislação nacional vigente. / This study describes the development of a compact device to treat groundwater contaminated with BTEX and TPH in gas stations. This environmental issue raises concerns worldwide, due to the level of contamination, the high occurrence of leaks, the toxicity of contaminants, and the importance of aquifers for human consumption. The equipment was formed by: a) a suction and treatment stage using vacuum and aeration with injectors (to replace the suction system based on a conventional vacuum pump and the air stripping and/or air sparging system); b) small-scale surface aerators (to replace the air stripping and/or air sparging system); c) an adsorption filter using a mixture of activated carbon (50%) and rice husk ash (50%) (to replace the activated carbon system). The experiment was conducted in four stages: a) characterization of groundwaters; b) presentation of the adsorbents used in the filter; c) pilot test (under controlled conditions to measure the efficiency to remove BTEX and TPH); and d) the full-scale tests (observation and confirmation of equipment efficiency). The results show that the remediation equipment developed is highly efficient to treat contaminated groundwater. An 8-h retention time afforded to reduce BTEX and TPH levels by over 96%. In this scenario, the treated water parameters meet the current legal requirements for discharge.
9

Equipamento compacto para o tratamento de águas subterrâneas contaminadas por BTEX e TPH

Caetano, Marcelo Oliveira January 2014 (has links)
O objetivo desta tese foi o desenvolvimento de um equipamento compacto para o tratamento de águas subterrâneas contaminadas por BTEX e TPH em postos de combustíveis. Esta questão ambiental é uma preocupação mundial devido ao nível de contaminação e a quantidade de vazamentos existentes, toxicidade dos poluentes e a necessidade de uso de aquíferos para consumo humano. O equipamento é composto por unidades que contemplam as seguintes etapas: (a) sucção e volatilização de compostos orgânicos voláteis; (b) injeção de ar (“air sparging”) para remoção de substâncias orgânicas voláteis; e (c) filtro de adsorção com recheio composto por mistura de 50% de carvão ativado e 50% de cinza de casca de arroz para a remoção de TPH. A parte experimental envolveu a caracterização de águas subterrâneas contaminadas e estudos em escala piloto e real. Os resultados obtidos demostraram que o equipamento de remediação desenvolvido é altamente eficiente para o tratamento de águas subterrâneas contaminadas. Com um tempo de detenção de 8 horas, obtiveram-se decréscimos superiores a 96% de BTEX e TPH. Nesta situação, a água contaminada tratada alcança valores que atendem aos critérios de lançamento estabelecidos pelas legislação nacional vigente. / This study describes the development of a compact device to treat groundwater contaminated with BTEX and TPH in gas stations. This environmental issue raises concerns worldwide, due to the level of contamination, the high occurrence of leaks, the toxicity of contaminants, and the importance of aquifers for human consumption. The equipment was formed by: a) a suction and treatment stage using vacuum and aeration with injectors (to replace the suction system based on a conventional vacuum pump and the air stripping and/or air sparging system); b) small-scale surface aerators (to replace the air stripping and/or air sparging system); c) an adsorption filter using a mixture of activated carbon (50%) and rice husk ash (50%) (to replace the activated carbon system). The experiment was conducted in four stages: a) characterization of groundwaters; b) presentation of the adsorbents used in the filter; c) pilot test (under controlled conditions to measure the efficiency to remove BTEX and TPH); and d) the full-scale tests (observation and confirmation of equipment efficiency). The results show that the remediation equipment developed is highly efficient to treat contaminated groundwater. An 8-h retention time afforded to reduce BTEX and TPH levels by over 96%. In this scenario, the treated water parameters meet the current legal requirements for discharge.

Page generated in 0.1115 seconds