• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • Tagged with
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Metalografia, análise de oxigênio e nitrogênio e teste de dureza vickers dos materiais de fixação interna usados no esqueleto craniofacial / Metallography, oxygenand nitrogen composition and vickers hardness test of internal fixation materials used in the craniofacial skeleton

Mendes, Marcelo Breno Meneses, 1984- 21 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T14:42:14Z (GMT). No. of bitstreams: 1 Mendes_MarceloBrenoMeneses_M.pdf: 5487742 bytes, checksum: e1f89d1bc60060a4c330175efda763d9 (MD5) Previous issue date: 2012 / Resumo: Este trabalho tem o objetivo de analisar, através de metalografia, análise da composição de gases oxigênio e nitrogênio e por meio de teste de dureza Vickers, 4 marcas de material de fixação interna utilizadas na cirurgia buco-maxilo-facial (grupo I = Leibinger; grupo II = Tóride; grupo III = Engimplan; grupo IV = Medartis). Inicialmente, foram confeccionados três corpos de prova com segmento de placa de três elos e três corpos de prova com parafusos, para cada grupo. Realizou-se preparação e análise metalográfica, de acordo com as normas da ASTM E3-95. Em seguida, as amostras foram submetidas ao teste de dureza Vickers, obedecendo às normas da ASTM E92. Após, foi realizado análise da composição de gases oxigênio e nitrogênio, com um segmento de elo de placa e um parafuso, para cada grupo. Os dados foram submetidos à análise de variância e teste de Tukey para comparação dos resultados. Todas as etapas dos processos foram registradas e fotografadas. De acordo com os resultados encontrados, os parafusos apresentaram maior dureza, em comparação com as placas. Entre estas, as placas do grupo IV apresentaram os grãos de maiores dimensão. A análise da composição dos gases revelou que todos os grupos atendem às normas ASTM / Abstract: This study aims to analyze 04 brands of internal fixation material, used in oral and maxillofacial surgery (Leibinger = group I; Tóride = group II; Engimplan = group III; Medartis = group IV) by metallography, analyzing the composition of gaseous oxygen (O) and nitrogen (N), and Vickers hardness testing. Initially,three specimens with three rings of the plate and three specimens with screws were made for each group. The preparation of the specimens was performed to metallographic analysis, attending the ASTM E3-95 standards. And then the samples were submitted to Vickers hardness test, according to the ASTM E92 standards. Thereafter, the composition analysis of the contents of O and N in all groups was performed with a ring of the plate and a screw for each group. Data were submitted to ANOVA and Tukey's test for result comparison. All steps of the process were recorded and photographed. According to the results, the screws had higher hardness, compared to the plates. Including, the plates of group IV showed the largest grain size. The analysis of the gas composition showed that all groups followed ASTM standards / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
2

Following the mevalonate pathway to bone heal alley /

Skoglund, Björn, January 2007 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2007. / Härtill 4 uppsatser.
3

Following the mevalonate pathway to bone heal alley /

Skoglund, Björn, January 2007 (has links)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2007. / Härtill 4 uppsatser.
4

Avaliação sobre dados de falhas de ventiladores mecânicos pulmonares em hospitais regionais da Paraíba

Figueiredo, Renata Italiano da Nóbrega 14 October 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-24T12:57:22Z No. of bitstreams: 1 PDF - Renata Italiano da Nóbrega Figueiredo.pdf: 23326888 bytes, checksum: 8f0f75d92f77a45b57d5db9a220d98be (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2018-06-05T11:34:10Z (GMT) No. of bitstreams: 1 PDF - Renata Italiano da Nóbrega Figueiredo.pdf: 23326888 bytes, checksum: 8f0f75d92f77a45b57d5db9a220d98be (MD5) / Made available in DSpace on 2018-06-05T11:34:10Z (GMT). No. of bitstreams: 1 PDF - Renata Italiano da Nóbrega Figueiredo.pdf: 23326888 bytes, checksum: 8f0f75d92f77a45b57d5db9a220d98be (MD5) Previous issue date: 2016-10-14 / Os ventiladores mecânicos pulmonares (VMP), são dispositivos utilizados frequentemente em unidades de terapia intensiva (UTI), para pacientes clinicamente críticos. Qualquer falha neste dispositivo pode representar risco para segurança do paciente, podendo proporcionar danos temporários ou permanentes. Desse modo, objetivou-se avaliar os dados sobre as causas de falhas dos ventiladores mecânicos pulmonares em hospitais regionais da Paraíba. Tratou-se de uma pesquisa retrospectiva, transversal, documental e descritiva, com abordagem quantitativa. A pesquisa foi realizada em hospitais regionais no estado da Paraíba. A amostra foi do tipo não probabilística por acessibilidade, constituído por 422 fichas e o universo foi constituído por fichas de reparo e manutenção preventiva de ventiladores mecânicos pulmonares (VMP) preenchidas entre os anos de 2012 a 2016 dos hospitais em questão. Foram utilizados os seguintes instrumentos para avaliação: ficha de categorização dos dispositivos e argumentação estruturada. Os dados obtidos foram expressos, descritivamente, em média, desvio padrão da média e porcentagem. A análise estatística foi feita através do programa IBM-SPSS versão 20.0. Este trabalho foi submetido ao Comitê de Ética em Pesquisa da Universidade Estadual da Paraíba sob o número 54007116.9.0000.5187. Nos resultados desta pesquisa, foi identificado falhas nos VMP, onde problemas de bateria, software, célula de oxigênio, calibração, teclado, display e válvulas foram as mais frequentes. Após a análise de falhas, constatou-se que intercorrências mecânicas que interferem na Fração Inspirada de Oxigênio (FiO2) estão diretamente relacionadas ao não fornecimento de gás (n= 18), vazamentos (n= 18), falha na ciclagem (n= 30), pane eletrônica (n= 25), entre outros. Problemas administrativos como subnotificação e um mal armazenamento de dados também foram encontrados. O resultado desta pesquisa pode oferecer subsídios para um melhor gerenciamento de risco, no desenvolvimento de protocolos assistenciais, em uma articulação sistêmica entre possíveis sinais de alertas e respectivas necessidades de intervenções administrativas juntamente com a engenharia clínica. / Pulmonary mechanical ventilators (VMP) are devices often used in intensive care units (ICU) for clinically critical patients. Any failure in this device may present a risk to patient safety and can provide temporary or permanent damage. Thus, it aimed to evaluate the data on the causes of failure of pulmonary mechanical ventilators in regional hospitals of Paraiba. This was a retrospective study, cross, documentary and descriptive, with quantitative approach. The survey was conducted in regional hospitals in the state of Paraiba. The sample was non probabilistic accessibility, consisting of 422 records and the universe consisted of repair records and preventive maintenance of pulmonary mechanical ventilators (VMP) filled between the years 2012-2016 of the hospitals in question. Categorization form of devices and structured argument: the following instruments for evaluation were used. Data were expressed descriptively as mean, standard deviation from the mean and percentage. Statistical analysis was performed using the IBM-SPSS version 20.0 program. This study was submitted to the Ethics Committee of the Paraíba State University under number 54007116.9.0000.5187. The results of this research, was identified flaws in the VMP where battery problems, software, oxygen cell calibration, keyboard, display and valves were the most frequent. After the failure analysis, it was found that mechanical complications that interfere with the inspired oxygen fraction (FiO2) are directly related to non-supply of gas (n = 18), leaks (n = 18), failure to cycling (n = 30), electronic part (n = 25), among others. Administrative problems such as underreporting and a data storage poorly were also found. The result of this research may provide insight for better risk management, development of care protocols, in a systemic link between possible signs of alerts and their needs administrative interventions with clinical engineering.
5

Análise fractográfica e de resistência mecânica de duas marcas de placas de titânio em fraturas simuladas em corpo de hemimandíbulas de alumínio / Fractographic and mechanical analysis of two brands of titanium plates in simulated body fractures of aluminum hemimandibles

Moura, Andrezza Lauria de, 1982- 06 April 2013 (has links)
Orientadores: Marcelo Marotta Araújo, Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:56:38Z (GMT). No. of bitstreams: 1 Moura_AndrezzaLauriade_M.pdf: 4155630 bytes, checksum: 44572134d9e31084a7892cb0866a1d79 (MD5) Previous issue date: 2013 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fractográfica, duas marcas de material de fixação interna estável com dois métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de alumínio. O trabalho foi dividido em dois grupos: Grupo I com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação com duas placas de titânio de quatro furos do sistema 2,0mm, sendo uma placa na zona de compressão e outra zona de tensão, totalizando 20 placas de titânio; e grupo II, com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação de uma placa de titânio de quatro furos do sistema 2,0mm na zona neutra de corpo de mandíbula, totalizando 10 placas de titânio. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®, até a fratura do material. Após os testes, foram realizadas as análises fractográficas das superfícies de fratura dos materiais de fixação (grupos I e II) através de microscópio eletrônico de varredura FEI®, com o objetivo de analisar orientações, texturas e falhas dos materiais. Médias e desvio padrão das cargas e deslocamentos foram avaliados aplicando-se a Análise de Variância (ANOVA) two-way e teste de Tukey em nível de significância de 5%. Os resultados mostraram que o método de fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01), quando comparado ao grupo de apenas uma placa de titânio na zona neutra mandibular. Ainda, a marca Traumec® apresentou maior resistência mecânica (p<0,01) quando utilizada no método com duas placas de fixação e a marca Tóride® (p<0,01) apresentou maior resistência as carga quando utilizada no método com apenas uma placa de fixação. A fractografia informou que todas as fraturas ocorreram por sobrecarga dúctil e micromecanismo alveolar / Abstract: The purpose of the study was to comparatively evaluate, through linear load test and fractographic analysis, two brands of stabel internal fixation in two methods of fixation in simulated body fractures in aluminium hemimandibules. The study was divided into two groups: Group I with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the compression zone and another one in tension zone, totaling 20 miniplates; and group II, with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the neutral zone of the mandible, totaling 10 miniplates. Mechanical tests were performed via mechanical universal testing machine Instron¿ until complete failure of the material. After the tests, fractography analysis of fractured surfaces were done in all materials (groups I and II) by a FEI¿ scanning electron microscopy, with the objective of analyzing orientation and textures of materials failures. Means and standard deviations of load and displacement were evaluated by applying the analysis of variance (ANOVA) two-way and the Tukey test at a significance level of 5%. The results showed that the method of fixation with two titanium plates with four holes showed higher resistance loads (p<0,01), when compared to only one titanium plate in the neutral zone of the mandible. Furthermore, the brand Traumec¿ showed higher mechanical strength (p<0,01) when used in the method with two fixing plates and the brand Toride¿ (p<0,01) showed a higher resistance to loads when used in the method with only one miniplate. The fractography reported that all fractures occurred in ductile overload and alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica
6

Following the mevalonate pathway to bone heal alley

Skoglund, Björn January 2007 (has links)
The mevalonate pathway is an important biosynthetic pathway, found in all cells of virtually all known pro- as well as eukaryotic organisms. This thesis is an investigation into the use of two drugs, originally developed for different applications, but both affecting the mevalonate pathway, in to models of fracture repair. Using two different rodent models of fracture repair, a commonly used cholesterol lowering drug (statin) and two drugs used to treat osteoporosis (bisphosphonate) were applied both systemically as well as locally in order to enhance fracture repair. Papers I and II investigate the potential of simvastatin to improve the healing of femoral fractures in mice. Papers III and IV explore the use of two bisphosphonates to improve early fixation of stainless steel screws into rat bone. The statin simvastatin lead to an increased strength of the healing cellus. The application of bisphosphonates increased early screw fixation. It seems clear that both drugs have uses in orthopaedic applications. One interesting avenue of further research would be to combine the two classes of drugs and see if we can get the benefits while at the same time diminishing the drawbacks.

Page generated in 0.085 seconds