• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de um Monitor Portátil para detecção de Radiação Gama e Raios-X

Silva Neto, Paulo Jacinto da 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:14:32Z (GMT). No. of bitstreams: 2 arquivo2682_1.pdf: 7594410 bytes, checksum: 532ac39285ea302f98c5ad7c37c64db9 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Existem vários recursos para evitar que os indivíduos recebam doses equivalentes de radiação, excessivas ou desnecessárias e a proteção radiológica avalia se esses recursos são realmente eficientes, através da monitoração de área. A monitoração de área é utilizada para dar uma indicação dos níveis de radiação existentes em determinados locais. Utilizando-se deste método, pode-se estimar a dose recebida pelo pessoal que ocupa uma área específica, por um determinado tempo. O objetivo desse trabalho foi a construção de um monitor portátil, constituído de uma câmara de ionização em material equivalente ao tecido (CITE), com um volume de 600cc e de sua eletrônica associada que permite medir radiação gama e raios-X. Os resultados mostram uma resposta linear do monitor para diferentes taxas de dose. O teste de estabilidade da sua resposta também mostrou uma boa reprodutibilidade de ±1%. Uma pequena dependência energética para energias entre 16 - 200keV dentro da norma IEC 60846, 2001. Para a faixa de energia 200 - 1250keV, a dependência está acima dos valores estipulados pela IEC 60846, para esta faixa de energia é necessário a utilização de filtros para melhorar a dependência energética
2

Medidas do primeiro coeficiente de Townsend de ionização em misturas gasosas utilizadas em microdosimetria / Measurements of the first Townsend ionization coefficient in gaseous mixtures employed in microdosimetry

Petri, Anna Raquel 17 April 2017 (has links)
Microdosímetros gasosos geralmente empregam uma mistura gasosa equivalente ao tecido humano mole (Tissue-equivalent Gas TEG), composta de um hidrocarboneto, dióxido de carbono e nitrogênio, de forma que o poder de freamento na mistura e no tecido sejam semelhantes. Entretanto, independentemente do hidrocarboneto adotado, dados tanto teóricos como experimentais do primeiro coeficiente de Townsend de ionização (α) nestas misturas são raros, ainda que a primeira TEG, cujo metano é o gás majoritário, tenha sido proposta em 1956 por Rossi e Failla e continue sendo amplamente utilizada. Neste trabalho, dados do parâmetro α em TEGs baseadas no metano (CH4 64,4%, CO2 32,4% e N2 3,2%) e nos isômeros do butano (C4H10 51,4%, CO2 42,3% e N2 6,3%) são apresentados pela primeira vez em geometria planar para a faixa de campo elétrico normalizado pela densidade do gás (E/N) entre 100 290 Td (1 Td = 10-21 V.m2). O método de medidas adotado baseia-se na técnica de Townsend pulsada, onde o primeiro coeficiente de Townsend pode ser determinando comparando a corrente elétrica no regime de avalanche e a corrente de ionização primária gerada pela incidência de um feixe de laser de nitrogênio em um eletrodo metálico (catodo) de uma câmara de geometria planar, sendo o anodo um eletrodo de alta resistividade (ρ=2×1010Ω.m). O aparato experimental, até então operado apenas em pressão atmosférica, foi modificado para também trabalhar em baixa pressão (120 hPa), de modo a aumentar a faixa de E/N investigada. A validação do método e das alterações do sistema de detecção foi realizada utilizando os três gases componentes das TEGs cujos parâmetros de transporte são amplamente estudados: o nitrogênio, o dióxido de carbono e o metano. Observou-se que o parâmetro na TEG com metano assemelha-se com os valores determinados para o metano puro. Na TEG baseada no isobutano, ele é compatível com o primeiro coeficiente de Townsend do dióxido de carbono para campos acima de 170 Td. Já o parâmetro na mistura com n-butano é intermediário entre os valores obtidos para o dióxido de carbono e o nitrogênio. Os resultados experimentais, disponíveis em forma tabular, foram comparados com os simulados utilizando o programa Magboltz 2, evidenciando boa concordância dentro da incerteza experimental. / Gaseous microdosimeters usually employ a Tissue-equivalent Gas (TEG), made of a hydrocarbon, carbon dioxide and nitrogen, in order to make similar the stopping power in this mixture and in the human soft tissue. Notwithstanding, regardless the chosen hydrocarbon, both theoretical and experimental data on the first Townsend ionization coefficient (α) in this mixtures are rare, even though the first TEG, which methane is the most abundant gas, was proposed in 1956 by Rossi and Failla and it has been widely employed since then. In this work, data on the parameter α in TEGs based on methane (CH4 64.4%, CO2 32.4%, and N2 3.2%) and butanes isomers (C4H10 51.4%, CO2 42.3% e N2 6.3%) are presented for the first time in planar geometry in the gas density-normalized electric field (E/N) range between 100 290 Td (1 Td = 10-21 V.m2). The adopted method is based on the Pulsed Townsend Technique, where the first Townsend coefficient can be determined by comparing the electric current in the avalanche mode and the primary ionization current, produced by an nitrogen laser beam incidence in a metallic electrode (cathode) of a parallel plate chamber, which the anode is a resistive electrode (ρ=2×1010Ω.m). The experimental setup, previously operated only at atmospheric pressure, was adapted to work also at low pressure (120 hPa), in order to increase the investigated E/N range. The validation of both method and detection system modifications was made by employing three TEGs components, nitrogen, carbon dioxide and methane, whose transport parameters are extensively studied. The parameter in the methane-based TEG follows the behavior observed in pure methane. In the isobutane-based TEG, it is compatible with the first Townsend coefficient in carbon dioxide for E/N above 170 Td. The parameter in the n-butane-based TEG lies between the obtained values of in carbon dioxide and nitrogen. The experimental results, included in tabular form, agree with those from Magboltz 2 simulations within the experimental uncertainties.
3

Medidas do primeiro coeficiente de Townsend de ionização em misturas gasosas utilizadas em microdosimetria / Measurements of the first Townsend ionization coefficient in gaseous mixtures employed in microdosimetry

Anna Raquel Petri 17 April 2017 (has links)
Microdosímetros gasosos geralmente empregam uma mistura gasosa equivalente ao tecido humano mole (Tissue-equivalent Gas TEG), composta de um hidrocarboneto, dióxido de carbono e nitrogênio, de forma que o poder de freamento na mistura e no tecido sejam semelhantes. Entretanto, independentemente do hidrocarboneto adotado, dados tanto teóricos como experimentais do primeiro coeficiente de Townsend de ionização (α) nestas misturas são raros, ainda que a primeira TEG, cujo metano é o gás majoritário, tenha sido proposta em 1956 por Rossi e Failla e continue sendo amplamente utilizada. Neste trabalho, dados do parâmetro α em TEGs baseadas no metano (CH4 64,4%, CO2 32,4% e N2 3,2%) e nos isômeros do butano (C4H10 51,4%, CO2 42,3% e N2 6,3%) são apresentados pela primeira vez em geometria planar para a faixa de campo elétrico normalizado pela densidade do gás (E/N) entre 100 290 Td (1 Td = 10-21 V.m2). O método de medidas adotado baseia-se na técnica de Townsend pulsada, onde o primeiro coeficiente de Townsend pode ser determinando comparando a corrente elétrica no regime de avalanche e a corrente de ionização primária gerada pela incidência de um feixe de laser de nitrogênio em um eletrodo metálico (catodo) de uma câmara de geometria planar, sendo o anodo um eletrodo de alta resistividade (ρ=2×1010Ω.m). O aparato experimental, até então operado apenas em pressão atmosférica, foi modificado para também trabalhar em baixa pressão (120 hPa), de modo a aumentar a faixa de E/N investigada. A validação do método e das alterações do sistema de detecção foi realizada utilizando os três gases componentes das TEGs cujos parâmetros de transporte são amplamente estudados: o nitrogênio, o dióxido de carbono e o metano. Observou-se que o parâmetro na TEG com metano assemelha-se com os valores determinados para o metano puro. Na TEG baseada no isobutano, ele é compatível com o primeiro coeficiente de Townsend do dióxido de carbono para campos acima de 170 Td. Já o parâmetro na mistura com n-butano é intermediário entre os valores obtidos para o dióxido de carbono e o nitrogênio. Os resultados experimentais, disponíveis em forma tabular, foram comparados com os simulados utilizando o programa Magboltz 2, evidenciando boa concordância dentro da incerteza experimental. / Gaseous microdosimeters usually employ a Tissue-equivalent Gas (TEG), made of a hydrocarbon, carbon dioxide and nitrogen, in order to make similar the stopping power in this mixture and in the human soft tissue. Notwithstanding, regardless the chosen hydrocarbon, both theoretical and experimental data on the first Townsend ionization coefficient (α) in this mixtures are rare, even though the first TEG, which methane is the most abundant gas, was proposed in 1956 by Rossi and Failla and it has been widely employed since then. In this work, data on the parameter α in TEGs based on methane (CH4 64.4%, CO2 32.4%, and N2 3.2%) and butanes isomers (C4H10 51.4%, CO2 42.3% e N2 6.3%) are presented for the first time in planar geometry in the gas density-normalized electric field (E/N) range between 100 290 Td (1 Td = 10-21 V.m2). The adopted method is based on the Pulsed Townsend Technique, where the first Townsend coefficient can be determined by comparing the electric current in the avalanche mode and the primary ionization current, produced by an nitrogen laser beam incidence in a metallic electrode (cathode) of a parallel plate chamber, which the anode is a resistive electrode (ρ=2×1010Ω.m). The experimental setup, previously operated only at atmospheric pressure, was adapted to work also at low pressure (120 hPa), in order to increase the investigated E/N range. The validation of both method and detection system modifications was made by employing three TEGs components, nitrogen, carbon dioxide and methane, whose transport parameters are extensively studied. The parameter in the methane-based TEG follows the behavior observed in pure methane. In the isobutane-based TEG, it is compatible with the first Townsend coefficient in carbon dioxide for E/N above 170 Td. The parameter in the n-butane-based TEG lies between the obtained values of in carbon dioxide and nitrogen. The experimental results, included in tabular form, agree with those from Magboltz 2 simulations within the experimental uncertainties.

Page generated in 0.1226 seconds