• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fabricação de microeletrodos para aplicações em microscopia eletroquímica de varredura / Fabrication of microelectrodes for applications in scanning electrochemical microscopy

Castro, Pollyana Souza 19 August 2011 (has links)
No presente trabalho, microeletrodos de platina foram fabricados e empregados juntamente com a técnica de Microscopia Eletroquímica de Varredura (Scanning Electrochemical Microscopy - SECM) para a obtenção de informações a respeito da erosão ácida do esmalte dentário. Em uma etapa inicial do projeto, um procedimento de fabricação de microeletrodos utilizando o equipamento Micropipette Puller foi desenvolvido. A selagem e o polimento da área ativa dos dispositivos foram consideradas etapas críticas do processo de construção. Uma bomba a vácuo foi empregada durante a fabricação dos dispositivos, o que aumentou a eficiência da selagem do vidro sobre a microfibra. Os parâmetros do equipamento necessários à fabricação dos dispositivos foram otimizados e desta forma obteve-se uma metodologia reprodutível e eficiente. Assim, microeletrodos de diversos materiais e dimensões foram construídos e avaliados quanto à utilização em SECM. Uma metodologia alternativa para a redução no tamanho da ponta de prova foi proposta. Um polimento cuidadoso na ponta de prova foi feito e através de comparações entre Curvas de Aproximação teóricas e experimentais, chegou-se a microeletrodos com RG (razão raio do vidro e raio do microeletrodo) próximos de 15. Em uma segunda etapa do projeto, a erosão ácida do esmalte dentário foi investigada utilizando SECM. Empregando um microeletrodo de platina, foram obtidas imagens SECM que revelaram haver um intenso consumo de íons hidrogênio na interface esmalte dentário-solução ácida. Isso ocorre devido à reação de desmineralização da camada protetora do dente, sendo comprovado que este processo é relativamente rápido. Imagens SECM também mostraram diferenças topográficas do esmalte dentário e, desta forma, após um intenso processo de desmineralização ácida, a SECM foi utilizada para estimar a espessura da camada de esmalte erodida. Com o auxílio das Curvas de Aproximação concluiu-se que, após 48 horas de exposição, a camada de esmalte erodida foi de 18 µm e após 96 horas a espessura da camada erodida aumentou para 25 µm. Microscopia de Força Atômica também foi utilizada para visualização das mudanças morfológicas após o esmalte permanecer em contato com diferentes bebidas de elevada acidez. Desta forma, pode-se concluir que em longo prazo o esmalte dentário pode ser removido devido ao contato com substâncias ácidas, expondo a dentina ao ambiente bucal e gerando problemas de hipersensibilidade dentária. / In this study, platinum microelectrodes were fabricated with a Micropipette Puller and used in Scanning Electrochemical Microscopy (SECM) to obtain information on the acid erosion of tooth enamel. The sealing and polishing of the active area of the fabricated devices are considered critical steps in the construction process, hence a vacuum pump was used to enhance the efficiency of the seal of the glass microfiber. The parameters of the equipment were optimized allowing a reproducible and efficient method to be developed. Thus, microelectrodes of various materials and dimensions were constructed and evaluated for use in SECM. An alternative method for reducing the size of the probe was also proposed. A careful polishing of the probe was done and by comparing theoretical and experimental approach curves, microelectrodes with RG values near to 15 were obtained. The acid erosion of dental enamel was investigated using SECM and a platinum microelectrode as a probe to H+ ions. The obtained images revealed a significant and relatively fast consumption of H+ ions at the interface enamel-acid solution, as a consequence of the demineralization reaction of the protective layer. SECM images also showed topographical differences with respect to the tooth enamel and after an exhaustive process of acid demineralization, the thickness of the layer of eroded enamel was estimated. By using approach curves it was concluded that the thickness of the eroded enamel layer was around 18 µm after 48 hours of exposure, this value being enhanced to 25 µm after 96 hours. Atomic Force Microscopy was also used to confirm the morphological changes after exposing the enamel to different beverages with high acidity. Accordingly, one can conclude that the acid erosion of enamel exposes the dentin to the oral environment and creates problems associated with dental hypersensitivity.
2

Fabricação de microeletrodos para aplicações em microscopia eletroquímica de varredura / Fabrication of microelectrodes for applications in scanning electrochemical microscopy

Pollyana Souza Castro 19 August 2011 (has links)
No presente trabalho, microeletrodos de platina foram fabricados e empregados juntamente com a técnica de Microscopia Eletroquímica de Varredura (Scanning Electrochemical Microscopy - SECM) para a obtenção de informações a respeito da erosão ácida do esmalte dentário. Em uma etapa inicial do projeto, um procedimento de fabricação de microeletrodos utilizando o equipamento Micropipette Puller foi desenvolvido. A selagem e o polimento da área ativa dos dispositivos foram consideradas etapas críticas do processo de construção. Uma bomba a vácuo foi empregada durante a fabricação dos dispositivos, o que aumentou a eficiência da selagem do vidro sobre a microfibra. Os parâmetros do equipamento necessários à fabricação dos dispositivos foram otimizados e desta forma obteve-se uma metodologia reprodutível e eficiente. Assim, microeletrodos de diversos materiais e dimensões foram construídos e avaliados quanto à utilização em SECM. Uma metodologia alternativa para a redução no tamanho da ponta de prova foi proposta. Um polimento cuidadoso na ponta de prova foi feito e através de comparações entre Curvas de Aproximação teóricas e experimentais, chegou-se a microeletrodos com RG (razão raio do vidro e raio do microeletrodo) próximos de 15. Em uma segunda etapa do projeto, a erosão ácida do esmalte dentário foi investigada utilizando SECM. Empregando um microeletrodo de platina, foram obtidas imagens SECM que revelaram haver um intenso consumo de íons hidrogênio na interface esmalte dentário-solução ácida. Isso ocorre devido à reação de desmineralização da camada protetora do dente, sendo comprovado que este processo é relativamente rápido. Imagens SECM também mostraram diferenças topográficas do esmalte dentário e, desta forma, após um intenso processo de desmineralização ácida, a SECM foi utilizada para estimar a espessura da camada de esmalte erodida. Com o auxílio das Curvas de Aproximação concluiu-se que, após 48 horas de exposição, a camada de esmalte erodida foi de 18 µm e após 96 horas a espessura da camada erodida aumentou para 25 µm. Microscopia de Força Atômica também foi utilizada para visualização das mudanças morfológicas após o esmalte permanecer em contato com diferentes bebidas de elevada acidez. Desta forma, pode-se concluir que em longo prazo o esmalte dentário pode ser removido devido ao contato com substâncias ácidas, expondo a dentina ao ambiente bucal e gerando problemas de hipersensibilidade dentária. / In this study, platinum microelectrodes were fabricated with a Micropipette Puller and used in Scanning Electrochemical Microscopy (SECM) to obtain information on the acid erosion of tooth enamel. The sealing and polishing of the active area of the fabricated devices are considered critical steps in the construction process, hence a vacuum pump was used to enhance the efficiency of the seal of the glass microfiber. The parameters of the equipment were optimized allowing a reproducible and efficient method to be developed. Thus, microelectrodes of various materials and dimensions were constructed and evaluated for use in SECM. An alternative method for reducing the size of the probe was also proposed. A careful polishing of the probe was done and by comparing theoretical and experimental approach curves, microelectrodes with RG values near to 15 were obtained. The acid erosion of dental enamel was investigated using SECM and a platinum microelectrode as a probe to H+ ions. The obtained images revealed a significant and relatively fast consumption of H+ ions at the interface enamel-acid solution, as a consequence of the demineralization reaction of the protective layer. SECM images also showed topographical differences with respect to the tooth enamel and after an exhaustive process of acid demineralization, the thickness of the layer of eroded enamel was estimated. By using approach curves it was concluded that the thickness of the eroded enamel layer was around 18 µm after 48 hours of exposure, this value being enhanced to 25 µm after 96 hours. Atomic Force Microscopy was also used to confirm the morphological changes after exposing the enamel to different beverages with high acidity. Accordingly, one can conclude that the acid erosion of enamel exposes the dentin to the oral environment and creates problems associated with dental hypersensitivity.
3

Resistência de união de restaurações diretas em resina composta em dentina humana previamente submetida à erosão ácida / Microtensile bond strength of composite resin direct restorations on dentin previously submitted to acid erosion

Rigolizzo, Daniela dos Santos 11 September 2013 (has links)
A lesão não cariosa causada pela dissolução da estrutura dentária sem o envolvimento bacteriano é denominada lesão de erosão dental. Existe ainda a falta de consenso quanto ao tratamento dessas lesões, além de pouco conhecimento quanto ao comportamento delas frente aos procedimentos adesivos. Dentre os mais realizados, tratamentos através de restaurações adesivas têm sido os de melhor resultado. Este trabalho teve como objetivo avaliar a resistência de união (TBS) de restaurações de resina composta realizadas sobre um substrato de dentina erodida simulada, utilizando dois sistemas adesivos diferentes. 40 terceiros molares humanos não irrompidos tiveram o esmalte do terço oclusal completamente removidos, deixando a dentina exposta. Após ter sua superfície dentinária regularizada com lixa de carbeto de silício granulação #600, cada dente foi dividido ao meio, criando assim, 40 amostras pareadas, sendo uma das metades a amostra controle e a outra, experimental. Esta passou por um protocolo de criação de lesão de erosão simulada. Sobre o substrato dentinário de todas as amostras, foram confeccionadas restaurações em resina composta Z350 (3M ESPE). Previamente às restaurações, 20 amostras controle e suas respectivas experimentais foram condicionadas utilizando ácido forfórico 37% e sistema adesivo Adper Single Bond 2 (3M ESPE) (amostras CSB e ESB). As outras 20 amostras receberam o sistema adesivo auto-condicionante Clearfill SE (Kuraray) (amostras CCFe ECF). As amostras produziram palitos de aproximadamente 1,0 mm2 que foram submetidos ao teste de microtração com velocidade média de 0,5 mm/min até a fratura. Resultados estatísticos mostraram haver diferença significativa entre os grupos (usando ANOVA 1 variância, F=4,643). As amostras experimentais tratadas previamente com o adesivo Clearfill SE (ECF) mostraram valores de resistência de união significativamente maios altos quando comparadas com os valores dos outros grupos (m=42.16 ±20.509 Mpa) (p=0,0082). / Non carious lesions caused by dentals structure dissolution without involving bacterial acids are called dental erosion. There is still limited information regarding which treatments should be considered, as well as to how the eroded dentin behaves in adhesive procedures. This study aims to evaluate the effect of different adhesive systems on micro-tensile bond strength (TBS) on eroded dentin and its paired sound substrate sample. 40 non irrupted third human molars had the oclusal enamel removed with a low-speed diamond saw and their exposed superficial dentin surfaces were submitted to polishing with wet # 600-grit silicon carbide sandpaper to remove remaining enamel and plane the surface. Each molar was divided into two equal halves originating 40 paired samples- one control and one experimental. All experimental samples underwent a pH cycling protocol to create a simulated dental erosion lesion. A composite resin Z350 (3M ESPE) restoration was built on each samples surface. Previous to restoration, control group and their respective experimental halves were divided into 2 sub-groups. 20 control + experimental samples were treated with 37% phosphoric acid and Adper Single Bond 2 (3M ESPE) (CSB and ESB); The other 20 control+ experimental samples were treated with Clearfill SE (Kuraray) (CSE and ESE). All 40 restored teeth were cut yielding stick-shapped samples with a cross-sectional area of approximately 1.0 mm2 and were submitted to a micro-tensile force running at a crosshead speed of 0.5 mm/min until fracture. Statistic results showed significant difference among the groups (using the ANOVA test F= 4,643). The eroded dentin samples submitted to surface treatment with Clearfill SE (ECF) prior to restoration showed significantly higher bond strength results when compared to all the other groups (m=42.16 ±20.509 Mpa) (p=0,0082).
4

Resistência de união de restaurações diretas em resina composta em dentina humana previamente submetida à erosão ácida / Microtensile bond strength of composite resin direct restorations on dentin previously submitted to acid erosion

Daniela dos Santos Rigolizzo 11 September 2013 (has links)
A lesão não cariosa causada pela dissolução da estrutura dentária sem o envolvimento bacteriano é denominada lesão de erosão dental. Existe ainda a falta de consenso quanto ao tratamento dessas lesões, além de pouco conhecimento quanto ao comportamento delas frente aos procedimentos adesivos. Dentre os mais realizados, tratamentos através de restaurações adesivas têm sido os de melhor resultado. Este trabalho teve como objetivo avaliar a resistência de união (TBS) de restaurações de resina composta realizadas sobre um substrato de dentina erodida simulada, utilizando dois sistemas adesivos diferentes. 40 terceiros molares humanos não irrompidos tiveram o esmalte do terço oclusal completamente removidos, deixando a dentina exposta. Após ter sua superfície dentinária regularizada com lixa de carbeto de silício granulação #600, cada dente foi dividido ao meio, criando assim, 40 amostras pareadas, sendo uma das metades a amostra controle e a outra, experimental. Esta passou por um protocolo de criação de lesão de erosão simulada. Sobre o substrato dentinário de todas as amostras, foram confeccionadas restaurações em resina composta Z350 (3M ESPE). Previamente às restaurações, 20 amostras controle e suas respectivas experimentais foram condicionadas utilizando ácido forfórico 37% e sistema adesivo Adper Single Bond 2 (3M ESPE) (amostras CSB e ESB). As outras 20 amostras receberam o sistema adesivo auto-condicionante Clearfill SE (Kuraray) (amostras CCFe ECF). As amostras produziram palitos de aproximadamente 1,0 mm2 que foram submetidos ao teste de microtração com velocidade média de 0,5 mm/min até a fratura. Resultados estatísticos mostraram haver diferença significativa entre os grupos (usando ANOVA 1 variância, F=4,643). As amostras experimentais tratadas previamente com o adesivo Clearfill SE (ECF) mostraram valores de resistência de união significativamente maios altos quando comparadas com os valores dos outros grupos (m=42.16 ±20.509 Mpa) (p=0,0082). / Non carious lesions caused by dentals structure dissolution without involving bacterial acids are called dental erosion. There is still limited information regarding which treatments should be considered, as well as to how the eroded dentin behaves in adhesive procedures. This study aims to evaluate the effect of different adhesive systems on micro-tensile bond strength (TBS) on eroded dentin and its paired sound substrate sample. 40 non irrupted third human molars had the oclusal enamel removed with a low-speed diamond saw and their exposed superficial dentin surfaces were submitted to polishing with wet # 600-grit silicon carbide sandpaper to remove remaining enamel and plane the surface. Each molar was divided into two equal halves originating 40 paired samples- one control and one experimental. All experimental samples underwent a pH cycling protocol to create a simulated dental erosion lesion. A composite resin Z350 (3M ESPE) restoration was built on each samples surface. Previous to restoration, control group and their respective experimental halves were divided into 2 sub-groups. 20 control + experimental samples were treated with 37% phosphoric acid and Adper Single Bond 2 (3M ESPE) (CSB and ESB); The other 20 control+ experimental samples were treated with Clearfill SE (Kuraray) (CSE and ESE). All 40 restored teeth were cut yielding stick-shapped samples with a cross-sectional area of approximately 1.0 mm2 and were submitted to a micro-tensile force running at a crosshead speed of 0.5 mm/min until fracture. Statistic results showed significant difference among the groups (using the ANOVA test F= 4,643). The eroded dentin samples submitted to surface treatment with Clearfill SE (ECF) prior to restoration showed significantly higher bond strength results when compared to all the other groups (m=42.16 ±20.509 Mpa) (p=0,0082).

Page generated in 0.0344 seconds