Spelling suggestions: "subject:"esgoto incluído"" "subject:"esgoto concluído""
1 |
Remoção de matéria orgânica, nitrogênio e fósforo em esgoto diluído com reatores em bateladas sequenciaisSANTOS NETO, Antonio Gustavo dos 01 August 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-12-05T14:40:13Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Dissertação ANTONIO GUSTAVO BIBLIOTECA - versão final.pdf: 1726777 bytes, checksum: 84cfc9b69cd2e68ee079cffc86278903 (MD5) / Made available in DSpace on 2017-12-05T14:40:13Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Dissertação ANTONIO GUSTAVO BIBLIOTECA - versão final.pdf: 1726777 bytes, checksum: 84cfc9b69cd2e68ee079cffc86278903 (MD5)
Previous issue date: 2016-08-01 / CAPES / Matéria orgânica e nutrientes são poluentes presentes nos esgotos sanitários que,
quando não tratados e lançados nos corpos receptores, causam problemas
ambientais como a depleção de oxigênio dissolvido, a perda da biodiversidade e
aceleração do processo de eutrofização. A remoção de nutrientes dos esgotos
apesar de ser uma questão resolvida nos países desenvolvidos ainda é um desafio
para o Brasil. No presente trabalho foram operados dois reatores biológicos em
escala piloto sob o regime de bateladas sequências (RBS). Na fase de reação, os
reatores eram submetidos a condições anaeróbias, aeróbias e anóxicas, onde, um
dos reatores na fase aeróbia, operava em regime de aeração contínua (RC) e o
outro sob regime de aeração intermitente (RI). O afluente utilizado no sistema era
proveniente do tratamento preliminar de uma estação de tratamento de esgotos e
apresentou características de esgoto diluído (304 mgDQO.L-1). A carga orgânica
média aplicada ao sistema foi de 63,8 g.DQO-1.d-1 e relação DQO:P de 108,5. O
principal ácido graxo volátil presente no afluente foi o ácido acético (numa
concentração média de 38,5 mg.L-1). A remoção de matéria orgânica (avaliada em
termos de DQO) e de fósforo, através da remoção biológica avançada de fósforo
(EBPR) foram satisfatórias para os dois sistemas com remoções acima de 80%,
chegando a concentrações abaixo de 10 mgDQO.L-1 e 0,1 mgP.L-1, já a remoção de
nitrogênio só se manteve estável no reator de aeração contínua, onde foi alcançada
uma remoção de 97% para nitrogênio amoniacal e de 63% para nitrogênio total. / Organic matter and nutrients are pollutants presented in domestic wastewater, when
not treated and released into receiving water bodies may cause environmental
problems such as depletion of dissolved oxygen, biodiversity loss and acceleration in
the eutrophication process. Despite the removal of nutrients be successfully made in
developed countries, it is still a challenge in Brazil. In this study, two biological
reactors in pilot scale were operated under regime of batch sequence. In the reaction
phase, the reactors were carried out in anaerobic, aerobic and anoxic conditions.
One of the reactors in aerobic phase was operated under continuous aeration mode
(RC) and the other under intermittent aeration system (RI). The influent used in this
study underwent preliminary treatment in a wastewater treatment plant and
presented diluted sewage characteristics (304 mgDQO.L-1). The average organic
load applied to the system was 63.8 gDQO-1d-1 and ratio COD / P 108.5. The main
volatile fatty acid present in the influent was acetic acid (an average concentration of
38.5 mg. L-1). The removal of organic matter (measured in terms of COD) and
phosphorus, trough of Enhanced Biological Phosphorus Removal (EBPR)
were satisfactory for both systems with over 80% removal,
reaching concentrations below 10 mgDQO.L-1-one and 0.1 mgP.L-1. In addition, the
nitrogen removal remained stable only under continuous aeration reactor in which
97% of ammonia nitrogen and 63% of total nitrogen.
|
2 |
Decantação acelerada: alternativa para o tratamento de vazão excedente de esgoto - estudo na ETE Martim de Sá (Caraguatatuba/SP). / Lamella sedimentation: alternative for treatment of overflow sewage - study in ETE Martim de Sá (Caraguatatuba/SP).Gomes, Fernanda Cavalcante 12 April 2010 (has links)
Este estudo foi motivado pela necessidade de se tratar o excesso de vazão afluente às estações de tratamento de esgoto, que ocorre em dias de chuvas intensas. A hipótese central deste estudo é a de que a adoção de processo físico-químico para o tratamento de esgoto excedente diluído, pode ser vantajosa em relação ao aumento da capacidade com a ampliação dos sistemas exclusivamente biológicos. A pesquisa foi desenvolvida na ETE Martim de Sá da SABESP, localizada em Caraguatatuba/SP, onde o esgoto é tratado por lodos ativados em bateladas sequenciais. Estudou-se a variação da vazão de esgoto afluente na época de chuvas, bem como o funcionamento das bateladas. Além disso, foi avaliado o emprego da coagulação, floculação e sedimentação em decantador laminar para tratar o excesso de vazão com aplicação de sulfato de alumínio, cloreto férrico e polímero catiônico em uma estação piloto, após a realização de ensaios em escala de bancada em aparelho de Jar Test. O monitoramento da vazão afluente mostrou que em dias de chuvas e com ocorrência de desvios, a vazão máxima foi 220 L/s, ou seja, até 6 vezes maior que a vazão média de tempo seco. Para esta situação, o processo físico-químico pode tornar-se uma alternativa promissora, devido à sua capacidade de trabalho sob altas vazões em instalações de menor porte. Nos ensaios para se avaliar o tratamento físico-químico utilizou-se esgoto bruto pertencente a duas faixas de DBO: 50 e 100 mg/L e taxa de aplicação superficial no decantador de 76,82 m³ / m² / dia. A melhor dosagem de produto químico utilizada para tratar o esgoto bruto da faixa de DBO igual a 50 mg/L foi 40mg/L de cloreto férrico mais 0,5mg/L de polímero catiônico resultando em efluentes com DBO média de 26mg/L. Para o esgoto bruto da faixa de DBO igual a 100 mg/L a melhor dosagem foi a de 60mg/L de cloreto férrico, com DBO média dos efluentes igual a 44mg/L. Para esta faixa de trabalho é recomendável prever a aplicação de polímero. Por esta pesquisa concluiu-se que é possível atender aos limites legais de qualidade do esgoto tratado com o emprego do tratamento físico-químico, além disso produziu elementos importantes para subsidiar a avaliação econômica para a implantação desta tecnologia em paralelo ao sistema de lodo ativado nas situações de sobrecarga hidráulica. No entanto, a análise do fluxograma do funcionamento da estação com o processo de lodos ativado em bateladas, indicou que é possível efetuar o tratamento da vazão de 220 L/s pelo processo biológico. Assim, é recomendável a implantação do tratamento físico-químico somente se, após a realização do teste em escala real do funcionamento das bateladas com a vazão de 220 L/s, o tratamento biológico não atender aos padrões estabelecidos. / This study was motivated by the need to treat high wastewater influent exceeding in sewage treatment plants, which occurs on days of heavy rain. The central hypothesis of this study is that the physical-chemical process to treat dilute sewage overflow, it can be advantageous with respect to increased capacity and expansion of biological systems. The research was conducted in ETE Martim de Sá (SABESP), located in Caraguatatuba / SP, where the sewage is treated by sequencing batch reactor. It was studied the variation of the flow of wastewater during the rainy season, and the operation of the batch. Furthermore, it was evaluated the use of coagulation, flocculation and sedimentation in plate settler with application of aluminium sulfate, ferric chloride and cationic polymer in a pilot plant, after the testing of bench scale apparatus in Jar Test. Monitoring the inflow showed that on days of rainfall and bypass, the maximum flow was 220 L/s, up to 6 times the dry weather average flow. For this situation, the physico-chemical process may become a promising alternative, due to its ability to work under high flow rates in smaller facilities. In tests to evaluate the physical-chemical treatment was used two kinds of raw sewage: 50 and 100 mg/L BOD, overflow rate used in the plated settling tank was 76.82 m³/m² / day. The best dosage of chemical used to treat the raw sewage BOD of 50 mg/L was 40 mg/L ferric chloride plus 0.5 mg/L of cationic polymer, resulting in average effluent with BOD of 26 mg/L. For the raw sewage of the range BOD of 100 mg/L, 60 mg/L ferric chloride was the best dosage with an average BOD of effluent equal to 44 mg/L. For this range of work is recommended to provide for the application of polymer. This research concluded that it is possible to comply with the legal standard of treated sewage with physical-chemical treatment, also produced evidence that can help in the economic evaluation for the implementation of this technology in parallel with the activated sludge system in hydraulic overload situations. However, analysis of the flow diagram of operation of the station with the sequencing batch reactor, indicated that it is possible to make the treatment of flow of 220 L/s by the biological process. Therefore, is recommend the implementation of physical-chemical treatment only if after the test-scale operation of the batches with the flow rate of 220 L/s, the biological treatment doesn\'t meet the established standards.
|
3 |
Decantação acelerada: alternativa para o tratamento de vazão excedente de esgoto - estudo na ETE Martim de Sá (Caraguatatuba/SP). / Lamella sedimentation: alternative for treatment of overflow sewage - study in ETE Martim de Sá (Caraguatatuba/SP).Fernanda Cavalcante Gomes 12 April 2010 (has links)
Este estudo foi motivado pela necessidade de se tratar o excesso de vazão afluente às estações de tratamento de esgoto, que ocorre em dias de chuvas intensas. A hipótese central deste estudo é a de que a adoção de processo físico-químico para o tratamento de esgoto excedente diluído, pode ser vantajosa em relação ao aumento da capacidade com a ampliação dos sistemas exclusivamente biológicos. A pesquisa foi desenvolvida na ETE Martim de Sá da SABESP, localizada em Caraguatatuba/SP, onde o esgoto é tratado por lodos ativados em bateladas sequenciais. Estudou-se a variação da vazão de esgoto afluente na época de chuvas, bem como o funcionamento das bateladas. Além disso, foi avaliado o emprego da coagulação, floculação e sedimentação em decantador laminar para tratar o excesso de vazão com aplicação de sulfato de alumínio, cloreto férrico e polímero catiônico em uma estação piloto, após a realização de ensaios em escala de bancada em aparelho de Jar Test. O monitoramento da vazão afluente mostrou que em dias de chuvas e com ocorrência de desvios, a vazão máxima foi 220 L/s, ou seja, até 6 vezes maior que a vazão média de tempo seco. Para esta situação, o processo físico-químico pode tornar-se uma alternativa promissora, devido à sua capacidade de trabalho sob altas vazões em instalações de menor porte. Nos ensaios para se avaliar o tratamento físico-químico utilizou-se esgoto bruto pertencente a duas faixas de DBO: 50 e 100 mg/L e taxa de aplicação superficial no decantador de 76,82 m³ / m² / dia. A melhor dosagem de produto químico utilizada para tratar o esgoto bruto da faixa de DBO igual a 50 mg/L foi 40mg/L de cloreto férrico mais 0,5mg/L de polímero catiônico resultando em efluentes com DBO média de 26mg/L. Para o esgoto bruto da faixa de DBO igual a 100 mg/L a melhor dosagem foi a de 60mg/L de cloreto férrico, com DBO média dos efluentes igual a 44mg/L. Para esta faixa de trabalho é recomendável prever a aplicação de polímero. Por esta pesquisa concluiu-se que é possível atender aos limites legais de qualidade do esgoto tratado com o emprego do tratamento físico-químico, além disso produziu elementos importantes para subsidiar a avaliação econômica para a implantação desta tecnologia em paralelo ao sistema de lodo ativado nas situações de sobrecarga hidráulica. No entanto, a análise do fluxograma do funcionamento da estação com o processo de lodos ativado em bateladas, indicou que é possível efetuar o tratamento da vazão de 220 L/s pelo processo biológico. Assim, é recomendável a implantação do tratamento físico-químico somente se, após a realização do teste em escala real do funcionamento das bateladas com a vazão de 220 L/s, o tratamento biológico não atender aos padrões estabelecidos. / This study was motivated by the need to treat high wastewater influent exceeding in sewage treatment plants, which occurs on days of heavy rain. The central hypothesis of this study is that the physical-chemical process to treat dilute sewage overflow, it can be advantageous with respect to increased capacity and expansion of biological systems. The research was conducted in ETE Martim de Sá (SABESP), located in Caraguatatuba / SP, where the sewage is treated by sequencing batch reactor. It was studied the variation of the flow of wastewater during the rainy season, and the operation of the batch. Furthermore, it was evaluated the use of coagulation, flocculation and sedimentation in plate settler with application of aluminium sulfate, ferric chloride and cationic polymer in a pilot plant, after the testing of bench scale apparatus in Jar Test. Monitoring the inflow showed that on days of rainfall and bypass, the maximum flow was 220 L/s, up to 6 times the dry weather average flow. For this situation, the physico-chemical process may become a promising alternative, due to its ability to work under high flow rates in smaller facilities. In tests to evaluate the physical-chemical treatment was used two kinds of raw sewage: 50 and 100 mg/L BOD, overflow rate used in the plated settling tank was 76.82 m³/m² / day. The best dosage of chemical used to treat the raw sewage BOD of 50 mg/L was 40 mg/L ferric chloride plus 0.5 mg/L of cationic polymer, resulting in average effluent with BOD of 26 mg/L. For the raw sewage of the range BOD of 100 mg/L, 60 mg/L ferric chloride was the best dosage with an average BOD of effluent equal to 44 mg/L. For this range of work is recommended to provide for the application of polymer. This research concluded that it is possible to comply with the legal standard of treated sewage with physical-chemical treatment, also produced evidence that can help in the economic evaluation for the implementation of this technology in parallel with the activated sludge system in hydraulic overload situations. However, analysis of the flow diagram of operation of the station with the sequencing batch reactor, indicated that it is possible to make the treatment of flow of 220 L/s by the biological process. Therefore, is recommend the implementation of physical-chemical treatment only if after the test-scale operation of the batches with the flow rate of 220 L/s, the biological treatment doesn\'t meet the established standards.
|
Page generated in 0.0469 seconds