• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

“Caracterização de feixes eletrônicos monoenergéticos de baixas energias”

Neves, Rafael Felipe Coelho 22 July 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-06-28T14:15:00Z No. of bitstreams: 1 rafaelfelipecoelhoneves.pdf: 2969229 bytes, checksum: cff09b57af6263220760e29c729a1382 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T21:09:40Z (GMT) No. of bitstreams: 1 rafaelfelipecoelhoneves.pdf: 2969229 bytes, checksum: cff09b57af6263220760e29c729a1382 (MD5) / Made available in DSpace on 2017-08-07T21:09:40Z (GMT). No. of bitstreams: 1 rafaelfelipecoelhoneves.pdf: 2969229 bytes, checksum: cff09b57af6263220760e29c729a1382 (MD5) Previous issue date: 2011-07-22 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Em uma variedade de técnicas espectroscópicas de impacto de elétrons em amostras gasosas, é fundamental utilizar feixes de elétrons de baixas energias focalizados, colimados e monocromatizados. Sua intensidade deve ser tal que seja possível realizar a aquisição de dados em um tempo mínimo, apresentando boa estatística. O requisito da monocromatização é o que garante obter o máximo de informações espectroscópicas de dado espectro. É na região de baixas energias do elétron incidente que ocorrem importantes processos, tais como distorções na nuvem eletrônica do alvo, efeitos de polarização, efeitos de troca, captura eletrônica. Entretanto, é justamente nesta faixa de energia onde se observa maior dificuldade experimental de se trabalhar devido a alta sensibilidade do feixe eletrônico tanto incidente, como espalhado. Neste trabalho, desenvolvemos pela primeira vez no país um canhão de elétrons de baixas energias, produzindo feixes de elétrons monocromatizados. O canhão foi cuidadosamente caracterizado em termos da intensidade do feixe eletrônico incidente e sua monocromatização, atingindo-se valores de energia de 0,105 eV e intensidades de até 280 nA para feixes de 170 eV. / In a variety of spectroscopic techniques of electron impact on gaseous samples, it is essential to use electron beams of low energy focused, collimated and monochromatized. The electron beam intensity should be such that it is possible to perform data acquisition in minimal period time, with good statistics. The requirement of electron beam monochromatization ensures to get as much information of a spectrum. It is in the low-energy electron incident that important processes occur, such as distortions in the electron cloud of the target, polarization effects, exchange effects and electron capture. However, it is precisely in this energy range where the experiments are more difficult to run due to the high sensitivity of the incident and scattered electron beam. In this work, we developed first in this country an electron gun for low energies, producing monochromatized electron beams. The electron gun has been carefully characterized in terms of intensity of the incident electron beam and its capacity of monochromatization, reaching values of energy of 0.105 eV and beam intensities up to 280 nA of 170 eV.
2

Implantação de um analisador de baixas energias de elétrons com resolução angular em um espectrômetro de perda de energia de elétrons

Duque, Humberto Vargas 19 June 2012 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-10T14:00:21Z No. of bitstreams: 1 humbertovargasduque (1).pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor corrigir: Membro da banca: Filho, Jayr de Amorim on 2018-01-23T11:49:04Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-23T13:12:19Z No. of bitstreams: 1 humbertovargasduque (1).pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor verificar nome do arquivo, existe o número (1) humbertovargasduque (1).pdf on 2018-01-23T13:14:55Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-23T13:22:21Z No. of bitstreams: 1 humbertovargasduque.pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-01-24T13:40:22Z (GMT) No. of bitstreams: 1 humbertovargasduque.pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Made available in DSpace on 2018-01-24T13:40:22Z (GMT). No. of bitstreams: 1 humbertovargasduque.pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) Previous issue date: 2012-06-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho consiste no desenvolvimento, implantação e caracterização de um Analisador Cilíndrico Dispersivo 1270 em um Espectrômetro de Perda de Energia de Elétrons (EPEE) operando na região de energia de impacto de 10 a 200 eV, que está sendo desenvolvido no Laboratório de Espectroscopia Atômica e Molecular – LEAM da UFJF. Além do analisador, foram também desenvolvidos diversos trabalhos para otimização do circuito de controle do canhão de elétrons monocromatizado do EPEE, o que gerou ótima estabilidade, acarretando em um ganho considerável em intensidade do feixe produzido e melhoria no manuseio do mesmo. É descrito a implementação da variação angular da plataforma giratória que apóia o Analisador Cilíndrico Dispersivo 1270, bem como a medida desta variação, e também, do sistema de injeção do feixe gasoso através de uma cânula de molibidênio isolada eletricamente, com movimento verticalem relação ao disco onde estão instalados o canhão e analisador. Os testes de desempenho do Espectrômetro foram feitos a partir da análise da resolução de Energia ΔE do EPEE. Obtivemos ótimos resultados quanto a transmissão do feixe de elétrons monocromatizado através da região de colisão chegando até a região de detecção do espectrômetro. É descrito, também, uma avaliação das melhorias feitas no Circuito de Controle do Canhão de Elétrons Monocromatizado, obtendo excelentes resultados quanto a intensidade do feixe de elétrons na faixa de energia de 0,1-100 eV. / This work describes the development, implementation and characterization of a Cylindrical Dispersive Analyzer 1270 on a Electron Energy Loss Spectrometer (EELS) operating in the region of impact energy from 10 to 200eV, which is being developed at the Laboratory of Atomic Spectroscopy and Molecular – LEAM UFJF. In the analyzer, several studies have also been developed to optimize the control circuit of the monochromatized electron gun of the EELS, which generated great stability, resulting in a considerable gain in intensity of the beam produced and improved handling. We describe the implementation of the angular variation of the turntable that supports the Cylindrical Dispersive Analyzer 1270, and the measure of variation, and also injection system of the gas through a beam cannula molybdenum electrically isolated, with vertical movement relative to disk where the monochromatized electron gun and the energy analyzer of electrons are installed. Performance tests of the spectrometer were made from the analysis of the energy resolution ΔE of the EELS. We obtained excellent results about transmission of the electron beam across the monochromatization region collision reaching the detection region of the spectrometer. We describe also an assessment of the improvements made in the Control Circuit of the Monochromatized Electron Gun, obtaining excellent results for the intensity of the electron beam in the energy range 0.1-100 eV.

Page generated in 0.0718 seconds