Comparação de métodos de tratamento de amostras de biodiesel para determinação de Sódio usando espectrometria de absorção atômica com chama / Comparison of treatment methods for biodiesel samples for determination of Sodium using flame atomic absorption spectrometryLeonardo, Ana Cristina de Almeida 22 July 2016 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-06-02T19:35:12Z
No. of bitstreams: 1
AnaLeonardo.pdf: 617676 bytes, checksum: b538fd3ffdb436a8e246ec2a0e138840 (MD5) / Made available in DSpace on 2017-06-02T19:35:12Z (GMT). No. of bitstreams: 1
AnaLeonardo.pdf: 617676 bytes, checksum: b538fd3ffdb436a8e246ec2a0e138840 (MD5)
Previous issue date: 2016-07-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPQ) / Most analytical methods require a sample preparation to make it compatible with the technique and the equipment used. This paper proposes a comparison between alkaline solubilization using TMAH 25% and acid extraction with heating using HNO3 0.1 mol L -1 as preparation of biodiesel samples in order to determine sodium. The analytical technique used in this study was Flame Atomic Absorption Spectrometry - FAAS. The biodiesel samples used were synthesized from three commercially available oils: babassu oil, corn and soybeans. The interlaboratory biodiesel sample used to compare the proposed method with the official NBR 15556:2008, was provided by Laboratory of Analysis and Research in Analytical Chemistry of Petroleum and Biofuels - LAPQAP/UFMA. The final solution after solubilization with 25% TMAH in methanol was incompatible with FAAS technique. The high viscosity of the sample influenced directly in the aspiration causing significant variations in the readings and making it impossible to continue the analysis. Acid extraction HNO3 0.1mol.L -1 yielded better results, in addition, the physical conditions of the final solution were consistent with FAAS. The LOD and LOQ values were respectively 0.02 and 0.07 mg.Kg-1 for sodium. The obtained recoveries were between 102 and 110% at three different levels of fortification. In comparison with the dilution of biodiesel in xylene established by official standards, quantified concentrations showed values very close. The simplicity, accuracy, precision, less toxicity and low cost of the acidic extraction method suggest that this may be a good alternative for treating biodiesel sample to determine sodium. / A maioria dos métodos analíticos precisa de um preparo da amostra para torná-la compatível com a técnica e o equipamento utilizado. Este trabalho propõe uma comparação entre a solubilização alcalina usando TMAH 25% e a extração ácida com aquecimento usando HNO3 0,1 mol.L-1 como preparo das amostras de biodiesel visando a determinação de sódio. A técnica analítica utilizada no presente trabalho foi Espectrometria de Absorção Atômica com Chama FAAS. As amostras de biodiesel utilizadas foram sintetizadas a partir de três óleos vegetais disponíveis no comércio: babaçu, milho e soja. O Biodiesel interlaboratorial usado na comparação do método proposto com a norma oficial NBR 15556:2008, foi cedido pelo Laboratório de Análise e Pesquisa em Química Analítica de Petróleo e Biocombustíveis - LAPQAP/UFMA. A solução final após a solubilização com TMAH 25% em metanol foi incompatível com FAAS. A alta viscosidade da amostra influenciou diretamente na aspiração causando variações significativas nas leituras impossibilitando a continuidade das análises. A extração ácida com HNO3 0,1mol.L-1 proporcionou melhores resultados, além disso, as condições físicas da solução final foram consistentes com FAAS. Os valores de LD e LQ foram respectivamente: 0,02 e 0,07 mg.Kg-1 para sódio. A recuperação obtida foi entre 102 e 110 % em três níveis diferentes de fortificação. Na comparação com a diluição do biodiesel em xileno estabelecido pelas normas oficiais, as concentrações quantificadas apresentaram valores bem próximos. A simplicidade, exatidão, precisão, menor toxicidade e baixo custo do método de extração ácida, sugerem que esta pode ser uma boa alternativa de tratamento de amostra de biodiesel para determinação de sódio.
|
2 |
Desenvolvimento de metodologia alternativa para a determinação de elementos em nível de traços em amostras de carvão pela técnica de ICP-OESFerrarini, Suzana Frighetto January 2007 (has links)
Neste trabalho foi investigado o desenvolvimento de uma metodologia analítica alternativa para a determinação de As, Co, Cu, Mn, Ni, Pb, Zn e V em materiais de referência certificados de carvão pela técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES), utilizando a extração ácida assistida por ultra-som. Os elementos Cd e Se, presentes em baixas concentrações, foram quantificados pela técnica de espectrometria de massa com plasma indutivamente acoplado (ICP-MS). As amostras moídas (<45 μm) foram extraídas em ácido nítrico (HNO3) concentrado e após um tempo de repouso o volume foi completado com água desionizada ( HNO3 30% v/v). As suspensões foram homogeneizadas por uma sonda ultra-sônica e o volume completado para uma concentração final de HNO3 15% v/v. Após, as mesmas foram centrifugadas a 3000 rpm por 30 min e os elementos determinados no sobrenadante. Foram otimizados parâmetros instrumentais do ICP OES, a potência e tempo de sonicação da sonda ultra-sônica e o tempo de extração em HNO3. Foram investigados diferentes granulometrias e o efeito do aquecimento na extração dos elementos. Os melhores resultados foram obtidos quando as suspensões com tamanho de partículas <45 μm foram aquecidas por 2 horas em banho de vapor a 80 ºC, deixadas em repouso por 24 horas e homogeneizadas a 70 W por 60 s.Desta forma, os valores de concentração obtidos para Pb, Zn e Co em todos os materiais de referência certificados analisados, Mn no SARM 20 e 1635, Ni e Cu no SARM 18, SARM 19, SARM 20 e 1635, V no 1635, As no SARM 19, SARM 20 e 1632a, Cd no 1635, Se no SARM 19, SARM 20 e 1635, ficaram dentro dos intervalos de concentração dos valores certificados. A metodologia proposta, mostrou-se eficiente para a extração de elementos traço em materiais de referência certificados de carvão utilizando calibração externa e, possibilitou a extração quantitativa da maioria dos analitos investigados. Os limites de detecção (LOD) do método em μg g-1, para 0,2 g de amostra em 30 mL, foram de 1,0; 0,0005; 0,1; 0,1; 0,01; 0,2; 1,1; 0,01; 0,3 e 0,2 para As, Cd, Co, Cu, Mn, Ni, Pb, Se, V e Zn, respectivamente. Os desvios padrão relativos (RSDs) ficaram na faixa de 0,4 a 9,2%. Para elementos como Cu, Mn, Ni e V, cujos valores ficaram abaixo dos valores certificados em alguns materiais, utilizou-se a decomposição ácida em forno microondas e bloco digestor empregando uma mistura de HNO3 + HF + H2O2 e HNO3 + HCl + HF, respectivamente. Neste caso os melhores resultados foram obtidos quando foi utilizado oforno microondas. A metodologia proposta neste trabalho foi aplicada para a quantificação dos elementos em amostras reais de carvão e em material de referência certificado de sedimento marinho e de rio. De forma geral, a extração ácida assistida por ultra-som mostrou-se adequada para a determinação dos elementos de interesse nestas amostras, com algumas restrições quanto à exatidão, no caso dos materiais de referência certificados de sedimento. / In this work the development of an alternative analytical methodology for As, Co, Cu, Mn, Ni, Pb, Zn and V determination in coal certified reference materials by inductively coupled plasma optical emission spectrometry (ICP OES) technique, using ultrasound assisted acid extraction was investigated. The elements Cd and Se which are present at lower concentrations were quantified by inductively coupled plasma mass spectrometry (ICP-MS) technique. The ground samples (<45 μm) were extracted in concentrated HNO3, letting to stand and after the volume was completed with deionized water (30% v/v HNO3). The suspensions were homogenized by an ultrasonic probe and the volume was completed to a final concentration of 15% v/v HNO3. Afterwards, the samples were centrifuged at 3000 rpm for 30 minutes and the elements determined in the supernatant. Instrumental parameters of ICP OES have been optimized and also the power and time of sonication of the ultrasonic probe and the extraction time in HNO3. Different particle sizes and the effect of heating in the extraction of the elements were investigated. The best results were obtained when the slurries with particle size <45 μm were heated in a water bath for 2 hours at 80 ºC, left to stand for 24 hours and homogenized by the ultrasonic probe at 70 W for 60 seconds. In this way, the concentrations values obtained for Pb, Zn and Co in all analyzed certified reference materials, Mn in SARM 20 and 1635, Ni and Cu in SARM 18, SARM 19, SARM 20 and 1635, V in 1635, As in SARM 19, SARM 20 and 1632a, Cd in 1635, Se in SARM 19, SARM 20 and 1635 were within the concentration ranges of the certified values. The proposed methodology was efficient for trace elements extraction from coal samples using external calibration allowing the quantitative extraction of the majority of the elements investigated. The limit of detection (LOD) of the method in μg g-1, for a sample mass of 0.2 g in 30 mL, were of 1.0; 0.0005; 0.1; 0.1; 0.01; 0.2; 1.1; 0.01; 0.3 and 0.2 for As, Cd, Co, Cu, Mn, Ni, Pb, Se, V and Zn, respectively. The relative standard deviations (RSDs) were between 0.4 to 9.2%. For the elements Cu, Mn, Ni and V which values found were below the certified ones in some materials, the acid decomposition in microwave oven and in closed vessels heated in a block, was employed using a mixture of HNO3 + HF + H2O2 and HNO3 + HCl + HF, respectively. In this case, the best results were obtained when the microwave oven was used.The methodology proposed in this work was applied for the quantification of the elements in real coal samples and in certified reference material of marine and river sediments. In general, the ultrasound assisted acid extraction was adequate for the determination of the elements of interest in these samples but with some restrictions related to accuracy in the case of sediment certified reference materials.
|
3 |
Desenvolvimento de metodologia alternativa para a determinação de elementos em nível de traços em amostras de carvão pela técnica de ICP-OESFerrarini, Suzana Frighetto January 2007 (has links)
Neste trabalho foi investigado o desenvolvimento de uma metodologia analítica alternativa para a determinação de As, Co, Cu, Mn, Ni, Pb, Zn e V em materiais de referência certificados de carvão pela técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES), utilizando a extração ácida assistida por ultra-som. Os elementos Cd e Se, presentes em baixas concentrações, foram quantificados pela técnica de espectrometria de massa com plasma indutivamente acoplado (ICP-MS). As amostras moídas (<45 μm) foram extraídas em ácido nítrico (HNO3) concentrado e após um tempo de repouso o volume foi completado com água desionizada ( HNO3 30% v/v). As suspensões foram homogeneizadas por uma sonda ultra-sônica e o volume completado para uma concentração final de HNO3 15% v/v. Após, as mesmas foram centrifugadas a 3000 rpm por 30 min e os elementos determinados no sobrenadante. Foram otimizados parâmetros instrumentais do ICP OES, a potência e tempo de sonicação da sonda ultra-sônica e o tempo de extração em HNO3. Foram investigados diferentes granulometrias e o efeito do aquecimento na extração dos elementos. Os melhores resultados foram obtidos quando as suspensões com tamanho de partículas <45 μm foram aquecidas por 2 horas em banho de vapor a 80 ºC, deixadas em repouso por 24 horas e homogeneizadas a 70 W por 60 s.Desta forma, os valores de concentração obtidos para Pb, Zn e Co em todos os materiais de referência certificados analisados, Mn no SARM 20 e 1635, Ni e Cu no SARM 18, SARM 19, SARM 20 e 1635, V no 1635, As no SARM 19, SARM 20 e 1632a, Cd no 1635, Se no SARM 19, SARM 20 e 1635, ficaram dentro dos intervalos de concentração dos valores certificados. A metodologia proposta, mostrou-se eficiente para a extração de elementos traço em materiais de referência certificados de carvão utilizando calibração externa e, possibilitou a extração quantitativa da maioria dos analitos investigados. Os limites de detecção (LOD) do método em μg g-1, para 0,2 g de amostra em 30 mL, foram de 1,0; 0,0005; 0,1; 0,1; 0,01; 0,2; 1,1; 0,01; 0,3 e 0,2 para As, Cd, Co, Cu, Mn, Ni, Pb, Se, V e Zn, respectivamente. Os desvios padrão relativos (RSDs) ficaram na faixa de 0,4 a 9,2%. Para elementos como Cu, Mn, Ni e V, cujos valores ficaram abaixo dos valores certificados em alguns materiais, utilizou-se a decomposição ácida em forno microondas e bloco digestor empregando uma mistura de HNO3 + HF + H2O2 e HNO3 + HCl + HF, respectivamente. Neste caso os melhores resultados foram obtidos quando foi utilizado oforno microondas. A metodologia proposta neste trabalho foi aplicada para a quantificação dos elementos em amostras reais de carvão e em material de referência certificado de sedimento marinho e de rio. De forma geral, a extração ácida assistida por ultra-som mostrou-se adequada para a determinação dos elementos de interesse nestas amostras, com algumas restrições quanto à exatidão, no caso dos materiais de referência certificados de sedimento. / In this work the development of an alternative analytical methodology for As, Co, Cu, Mn, Ni, Pb, Zn and V determination in coal certified reference materials by inductively coupled plasma optical emission spectrometry (ICP OES) technique, using ultrasound assisted acid extraction was investigated. The elements Cd and Se which are present at lower concentrations were quantified by inductively coupled plasma mass spectrometry (ICP-MS) technique. The ground samples (<45 μm) were extracted in concentrated HNO3, letting to stand and after the volume was completed with deionized water (30% v/v HNO3). The suspensions were homogenized by an ultrasonic probe and the volume was completed to a final concentration of 15% v/v HNO3. Afterwards, the samples were centrifuged at 3000 rpm for 30 minutes and the elements determined in the supernatant. Instrumental parameters of ICP OES have been optimized and also the power and time of sonication of the ultrasonic probe and the extraction time in HNO3. Different particle sizes and the effect of heating in the extraction of the elements were investigated. The best results were obtained when the slurries with particle size <45 μm were heated in a water bath for 2 hours at 80 ºC, left to stand for 24 hours and homogenized by the ultrasonic probe at 70 W for 60 seconds. In this way, the concentrations values obtained for Pb, Zn and Co in all analyzed certified reference materials, Mn in SARM 20 and 1635, Ni and Cu in SARM 18, SARM 19, SARM 20 and 1635, V in 1635, As in SARM 19, SARM 20 and 1632a, Cd in 1635, Se in SARM 19, SARM 20 and 1635 were within the concentration ranges of the certified values. The proposed methodology was efficient for trace elements extraction from coal samples using external calibration allowing the quantitative extraction of the majority of the elements investigated. The limit of detection (LOD) of the method in μg g-1, for a sample mass of 0.2 g in 30 mL, were of 1.0; 0.0005; 0.1; 0.1; 0.01; 0.2; 1.1; 0.01; 0.3 and 0.2 for As, Cd, Co, Cu, Mn, Ni, Pb, Se, V and Zn, respectively. The relative standard deviations (RSDs) were between 0.4 to 9.2%. For the elements Cu, Mn, Ni and V which values found were below the certified ones in some materials, the acid decomposition in microwave oven and in closed vessels heated in a block, was employed using a mixture of HNO3 + HF + H2O2 and HNO3 + HCl + HF, respectively. In this case, the best results were obtained when the microwave oven was used.The methodology proposed in this work was applied for the quantification of the elements in real coal samples and in certified reference material of marine and river sediments. In general, the ultrasound assisted acid extraction was adequate for the determination of the elements of interest in these samples but with some restrictions related to accuracy in the case of sediment certified reference materials.
|
4 |
Desenvolvimento de metodologia alternativa para a determinação de elementos em nível de traços em amostras de carvão pela técnica de ICP-OESFerrarini, Suzana Frighetto January 2007 (has links)
Neste trabalho foi investigado o desenvolvimento de uma metodologia analítica alternativa para a determinação de As, Co, Cu, Mn, Ni, Pb, Zn e V em materiais de referência certificados de carvão pela técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES), utilizando a extração ácida assistida por ultra-som. Os elementos Cd e Se, presentes em baixas concentrações, foram quantificados pela técnica de espectrometria de massa com plasma indutivamente acoplado (ICP-MS). As amostras moídas (<45 μm) foram extraídas em ácido nítrico (HNO3) concentrado e após um tempo de repouso o volume foi completado com água desionizada ( HNO3 30% v/v). As suspensões foram homogeneizadas por uma sonda ultra-sônica e o volume completado para uma concentração final de HNO3 15% v/v. Após, as mesmas foram centrifugadas a 3000 rpm por 30 min e os elementos determinados no sobrenadante. Foram otimizados parâmetros instrumentais do ICP OES, a potência e tempo de sonicação da sonda ultra-sônica e o tempo de extração em HNO3. Foram investigados diferentes granulometrias e o efeito do aquecimento na extração dos elementos. Os melhores resultados foram obtidos quando as suspensões com tamanho de partículas <45 μm foram aquecidas por 2 horas em banho de vapor a 80 ºC, deixadas em repouso por 24 horas e homogeneizadas a 70 W por 60 s.Desta forma, os valores de concentração obtidos para Pb, Zn e Co em todos os materiais de referência certificados analisados, Mn no SARM 20 e 1635, Ni e Cu no SARM 18, SARM 19, SARM 20 e 1635, V no 1635, As no SARM 19, SARM 20 e 1632a, Cd no 1635, Se no SARM 19, SARM 20 e 1635, ficaram dentro dos intervalos de concentração dos valores certificados. A metodologia proposta, mostrou-se eficiente para a extração de elementos traço em materiais de referência certificados de carvão utilizando calibração externa e, possibilitou a extração quantitativa da maioria dos analitos investigados. Os limites de detecção (LOD) do método em μg g-1, para 0,2 g de amostra em 30 mL, foram de 1,0; 0,0005; 0,1; 0,1; 0,01; 0,2; 1,1; 0,01; 0,3 e 0,2 para As, Cd, Co, Cu, Mn, Ni, Pb, Se, V e Zn, respectivamente. Os desvios padrão relativos (RSDs) ficaram na faixa de 0,4 a 9,2%. Para elementos como Cu, Mn, Ni e V, cujos valores ficaram abaixo dos valores certificados em alguns materiais, utilizou-se a decomposição ácida em forno microondas e bloco digestor empregando uma mistura de HNO3 + HF + H2O2 e HNO3 + HCl + HF, respectivamente. Neste caso os melhores resultados foram obtidos quando foi utilizado oforno microondas. A metodologia proposta neste trabalho foi aplicada para a quantificação dos elementos em amostras reais de carvão e em material de referência certificado de sedimento marinho e de rio. De forma geral, a extração ácida assistida por ultra-som mostrou-se adequada para a determinação dos elementos de interesse nestas amostras, com algumas restrições quanto à exatidão, no caso dos materiais de referência certificados de sedimento. / In this work the development of an alternative analytical methodology for As, Co, Cu, Mn, Ni, Pb, Zn and V determination in coal certified reference materials by inductively coupled plasma optical emission spectrometry (ICP OES) technique, using ultrasound assisted acid extraction was investigated. The elements Cd and Se which are present at lower concentrations were quantified by inductively coupled plasma mass spectrometry (ICP-MS) technique. The ground samples (<45 μm) were extracted in concentrated HNO3, letting to stand and after the volume was completed with deionized water (30% v/v HNO3). The suspensions were homogenized by an ultrasonic probe and the volume was completed to a final concentration of 15% v/v HNO3. Afterwards, the samples were centrifuged at 3000 rpm for 30 minutes and the elements determined in the supernatant. Instrumental parameters of ICP OES have been optimized and also the power and time of sonication of the ultrasonic probe and the extraction time in HNO3. Different particle sizes and the effect of heating in the extraction of the elements were investigated. The best results were obtained when the slurries with particle size <45 μm were heated in a water bath for 2 hours at 80 ºC, left to stand for 24 hours and homogenized by the ultrasonic probe at 70 W for 60 seconds. In this way, the concentrations values obtained for Pb, Zn and Co in all analyzed certified reference materials, Mn in SARM 20 and 1635, Ni and Cu in SARM 18, SARM 19, SARM 20 and 1635, V in 1635, As in SARM 19, SARM 20 and 1632a, Cd in 1635, Se in SARM 19, SARM 20 and 1635 were within the concentration ranges of the certified values. The proposed methodology was efficient for trace elements extraction from coal samples using external calibration allowing the quantitative extraction of the majority of the elements investigated. The limit of detection (LOD) of the method in μg g-1, for a sample mass of 0.2 g in 30 mL, were of 1.0; 0.0005; 0.1; 0.1; 0.01; 0.2; 1.1; 0.01; 0.3 and 0.2 for As, Cd, Co, Cu, Mn, Ni, Pb, Se, V and Zn, respectively. The relative standard deviations (RSDs) were between 0.4 to 9.2%. For the elements Cu, Mn, Ni and V which values found were below the certified ones in some materials, the acid decomposition in microwave oven and in closed vessels heated in a block, was employed using a mixture of HNO3 + HF + H2O2 and HNO3 + HCl + HF, respectively. In this case, the best results were obtained when the microwave oven was used.The methodology proposed in this work was applied for the quantification of the elements in real coal samples and in certified reference material of marine and river sediments. In general, the ultrasound assisted acid extraction was adequate for the determination of the elements of interest in these samples but with some restrictions related to accuracy in the case of sediment certified reference materials.
|
5 |
Efeito das condições de extração sobre rendimento e características da pectina obtida de diferentes frações de goiaba CV Pedro Sato / Effect of extraction conditions on yields and characteristics of the pectin obtained from different fractions of guava CV Pedro SatoMUNHOZ, Claudia Leite 07 March 2008 (has links)
Made available in DSpace on 2014-07-29T15:22:57Z (GMT). No. of bitstreams: 1
Claudia munhoz.pdf: 644332 bytes, checksum: 80da90f86ec8e67bdffb9cd0bf254ba6 (MD5)
Previous issue date: 2008-03-07 / The objectives of this study were to characterize the raw material in nature, the flours of fractions of guava cv Pedro Sato and to optimize the factors that influence the yields of pectin extraction of flour of the guava pulp and pulp with peel. As characterize pectins obtained in optimal points on the degree of esterification, comparing them with the commercial pectin. Fruits were used for pectin.extraction. The fruits were divided in peel, pulp, pulp with peel and flesh, dry in stove with circulation of air. Samples in nature and drought were characterized physically and chemically. The central rotation composed design with four axial points and three replicates in the central point was used to optimize the extraction of pectin of flour of the guava pulp and pulp with peel. The extraction was performed in 4 g of flour to
200 mL of solution of citric acid at different concentrations and at different times of extraction, at temperature of 97 ° C. The esterification degree of extracted pectins was
compared to commercial pectin one. The highest yields in the extractions of pectin of flour of the guava pulp and pulp with peel were obtained with citric acid solution at 5 g (100 g)-1 and the extraction time of 60 min. Pectins showed up with low esterification, with 38.94% for the pulp and 40.99% for pulp with peel of guava. However, pectins showed the concentration of galacturonic acid next to the commercial standard of 65% and they can be applied in foods
with low soluble solids (diet or light food) / Os objetivos deste trabalho foram caracterizar a matéria-prima in natura, as farinhas das frações de goiaba cv Pedro Sato e otimizar os fatores que influenciam nos rendimentos de
extração de pectina das farinhas de polpa e de polpa com casca de goiaba. Assim como caracterizar as pectinas obtidas nos pontos ótimos quanto ao grau de esterificação, comparando-as com a pectina comercial. Os frutos foram separados em casca, polpa, polpa com casca e miolo, secos em estufa com circulação de ar. Amostras in natura e secas foram caracterizadas física e quimicamente. O planejamento composto central rotacional com quatro pontos axiais e três repetições no ponto central foi utilizado para otimizar a extração de pectina das farinhas de polpa e de polpa com casca de goiaba. A extração foi realizada em 4 g de farinha para 200 mL de solução de ácido cítrico em diferentes concentrações e em diferentes tempos de extração, a temperatura de 97 ºC. As pectinas extraídas foram comparadas com pectina comercial quanto ao grau de esterificação. Os maiores rendimentos nas extrações de pectina das farinhas da polpa e da polpa com casca de goiaba foram obtidos com solução de ácido cítrico a 5 g (100 g)-1 e tempo de extração de 60 min. As pectinas apresentaram-se de baixa esterificação, com 38,94% para a polpa e 40,99% para a polpa com casca de goiaba. No entanto, as pectinas apresentaram concentração de ácido galacturônico
próximo ao padrão comercial que é de 65%, podendo ser aplicadas em alimentos com baixo teor de sólidos solúveis (alimentos diet ou light)
|
6 |
Determinação de elementos maiores e traço em tecidos de moluscos bivalves por espectrometria de emissão óptica com plasma indutivamente acopladoSantil, Darlan da Silva January 2010 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-08-30T17:05:18Z
No. of bitstreams: 1
Dissertação - Darlan S Santil.pdf: 1852568 bytes, checksum: 56dd8cda0c9cfac1cef7ea49ee2facfb (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-02T15:26:24Z (GMT) No. of bitstreams: 1
Dissertação - Darlan S Santil.pdf: 1852568 bytes, checksum: 56dd8cda0c9cfac1cef7ea49ee2facfb (MD5) / Made available in DSpace on 2016-09-02T15:26:24Z (GMT). No. of bitstreams: 1
Dissertação - Darlan S Santil.pdf: 1852568 bytes, checksum: 56dd8cda0c9cfac1cef7ea49ee2facfb (MD5) / CAPES / O presente estudo propõe a determinação de elementos maiores e traço em invertebrados marinhos por
Espectrometria de Emissão Óptica com Plasma Indutivamente Acoplado (ICP OES) após um
procedimento assistido por radiação ultrassom e centrífuga, empregando ácidos diluídos. Um
planejamento Doehlert de três fatores foi aplicado para otimizar a extração dos elementos nas amostras
de bivalves (Mytella guyanensis, Anomalocardia brasiliana e Crassostrea rhizophorae). Os fatores
foram: concentração da mistura ácida (HCl + HNO3 + H3CCOOH; 1-3 mol L-1), tempo de centrifugação
(10-40 min.), e velocidade de rotação (6000-10000 rpm). A eficiência de extração expressa em
percentual foi escolhida como resposta analítica no processo de otimização. Além disso, todos os
experimentos foram realizados analisando o material de referência certificado NIST 1566b (tecido de
ostra). O percentual de recuperação obtida nas amostras de material de referência certificado pela
martiz Doehlert variou de 45-95, 8-52, 35-71, 67-102, 38-78, 61-92, 58-100, 39-85 e 51-91%,
respectivamente, para Ca, Cd, Cu, K, Mg, Mn, Na, Sr, e Zn. Todavia, ponto de máximo não foi obtido.
Portanto, a resposta múltipla foi escolhida para obtenção dos valores máximos de extração dos metais.
As seguintes condições experimentais da resposta múltipla foram selecionadas: 20 min de tempo de
extração, 9000 rpm de velocidade de rotação e 1,0 mol L-1 da mistura ácida. A fim de avaliar o efeito do
ultrassom na extração dos elementos, uma porção de tecido de ostra certificado foi sonicada por 15 min
em um banho de ultrassom à temperatura ambiente e a solução foi centrifugada nas condições
otimizadas. Os resultados mostraram que o uso da sonicação antes da centrifugação promoveu um
aumento na porcentagem de recuperação dos elementos estudados. A repetitividade do procedimento
auxiliado por centrífuga e ultrassom foi avaliada pela determinação de elementos maiores e traço em 10
replicatas do material certificado. Os desvios padrões relativos (RSD) para o procedimento proposto
variam entre 1,8 a 4,7. A exatidão do método foi confirmada pela análise de tecido de ostra certificado
(NIST 1566b) e por comparação de método analítico de referência com procedimento de digestão ácida
para o tratamento das amostras (microondas com cavidade). Os resultaldos da análise da exatidão de
alguns elementos estudados mostraram que não havia diferenças significativas (p<0,05) entre o método
proposto e o método de referência. Concomitantemente ao desenvolvimento do método analítico, as
concentrações dos elementos menores e maiores em amostras dos bivalves coletados ao longo da Baía
de Todos os Santos, Bahia, Brasil foram determinadas por ICP OES após o procedimento de digestão
ácida em bombas Parr. Os resultados da determinação revelaram que as concentrações de As, Cu e Zn
nos bivalves estavam acima dos limites máximos estabelecidos pela ANVISA e por agências
especializadas em saúde internacionais. Esses valores de concentração sugerem que deve ser feita
uma análise de risco a / The present study proposes the determination of major and trace elements in marine invertebrates by
Inductively Coupled Plasma Optical Emission Spectroscopy (ICP OES) after a procedure assisted by
ultrasound radiation and centrifugal, employing diluted acids. A three factor Doehlert design was applied
to optimize the extraction of elements in bivalves (Mytella guyanensis, Anomalocardia brasiliana and
Crassostrea rhizophorae). The factors were: concentration of acid mixture (HCl + HNO3 + H3CCOOH;
1-3 mol L-1), centrifugation time (10-40 min.), and rotation velocity (6000-10000 rpm). The extraction
efficiency, expressed as a percentage, was chosen as the analytical response in the optimization
process. In addition, all experiments were performed by analyzing the certified reference material NIST
1566b (oyster tissue). The percentage of recovery obtained in the samples of certified reference material
by Doehlert varied from 45-95, 8-52, 35-71, 67-102, 38-78, 61-92, 58-100, 39-85 and 51-91%,
respectively, for Ca, Cd, Cu, K, Mg, Mn, Na, Sr, and Zn. However, maximum point wasn’t obtained. So,
the multiple response was chosen to obtain the maximum extraction of the metals. The following
experimental conditions of multiple response were selected: 20 min of extraction time, 9000 rpm of the
speed centrifuge and 1.0 mol L-1 of the acid mixture. In order to evaluate the ultrasound effect on the
extraction of trace elements a portion of the certified oyster tissue sample was sonicated for 15min in an
ultrasonic bath at ambient temperature, and then the solution was centrifuged at the optimized
conditions. Results showed that the use of the sonication prior to the centrifugation promoted an increase
in the percentage of recovery for most studied elements. The repeatability of the centrifugation and ultra-
sound assisted procedure was evaluated by the determination of trace and major elements in 10
replicates of the oyster tissue certified material. The relative standard deviations (RSD) for the
centrifugation and ultrasound assisted procedure varied between 1.8 and 4.7%. The accuracy of the
method was confirmed by analysis of the certified oyster tissue (NIST 1566b) and by reference analytical
method comparison with acid digestion procedure for the sample treatment (microwave cavity). The
results of the analysis of the accuracy of some elements studied showed that there were no significant
differences (p <0.05) between the proposed method and the reference method. Concurrent with the
development of the acid extraction procedure, the major and trace concentrations of elements in mussel,
oyster and clams samples collected from along coastal the zones of Todos os Santos Bay were
determined by ICP OES after Parr acid digestion bombs. The results of determination showed that
concentrations of As, Cu and Zn in the bivalves were above the limits established by ANVISA and
international agencies specializing in health. These concentration values suggest that must be a health
risk analysis mainly in the communities that collect the shellfish as a subsistence activity.
|
7 |
Influência da granulometria do bagaço de cana-de-açúcar na solubilização de hemicelulose e produção de açúcares fermentáveis / Influence of the granulometry of sugarcane bagasse on the solubilization of hemicellulose and the production of fermentable sugarsAlves, Rosângela Cristina 27 July 2018 (has links)
Submitted by Rosângela Cristina Alves (rosangela.alves@etec.sp.gov.br) on 2018-09-26T02:51:48Z
No. of bitstreams: 1
Dissertacao-FINAL Rosangela C. Alves - repositorio.pdf: 1876874 bytes, checksum: 2f37062ec0152ad7c5ccde681207d93b (MD5) / Approved for entry into archive by Ana Paula Santulo Custódio de Medeiros null (asantulo@rc.unesp.br) on 2018-09-26T11:31:00Z (GMT) No. of bitstreams: 1
alves_rc_me_rcla.pdf: 1836538 bytes, checksum: 3798050a36146a32df2e62013e4e7c2a (MD5) / Made available in DSpace on 2018-09-26T11:31:00Z (GMT). No. of bitstreams: 1
alves_rc_me_rcla.pdf: 1836538 bytes, checksum: 3798050a36146a32df2e62013e4e7c2a (MD5)
Previous issue date: 2018-07-27 / A grande capacidade da agricultura sucroalcooleira, aliada às suas dimensões continentais, faz do Brasil o maior produtor de cana-de-açúcar do mundo. O bagaço desta matéria-prima é um material lignocelulósico, remanescente da moagem dos seus colmos, é composto principalmente por celulose, hemicelulose e lignina, numa estrutura vegetal organizada que deve ser desestruturada mediante pré-tratamentos para disponibilizar a fração polissacarídica (celulose e hemicelulose). Objetivou-se com a presente pesquisa determinar a influência da granulometria do bagaço de cana-de-açúcar na extração/solubilização de hemicelulose na forma de polissacarídeo (macromolécula) e monossacarídeo (xilose). A extração da hemicelulose macromolecular foi realizada em condições otimizadas para bagaço de cana-de-açúcar, 6 % H2O2 m/v a 25 °C durante 4 h, utilizando bagaço selecionado em peneiras de 16, 30, 40, 50 mesh e base (material que passou pela peneira de 50 mesh). Para extração de hemicelulose na forma monomérica foi utilizado um pré-tratamento com ácido sulfúrico diluído 20 % (m/m), sendo que as amostras foram autoclavadas a 121 ºC por 1 h; a xilose no filtrado foi quantificado por HPLC. Foi realizada também a condutividade, determinação do teor de cinzas totais, solubilidade da hemicelulose. Os resíduos sólidos dos pré-tratamentos foram submetidos a hidrólise enzimática (12 FPU/g – Cellic Ctec) para determinação do rendimento em glicose. O bagaço in natura apresentou conteúdo de glucana de 42,25 %, arabinana de 2,62 %, xilana de 25,39 %, ácido acético de 3,38 % e lignina de 13,83 %. A xilana solubilizada em meio alcalino apresentou variação de 36,18 % (bagaço retido na peneira de 16 mesh) a 71,43 % (bagaço retido na base, inferior a 50 mesh), quanto menor o tamanho da partícula, maior a quantidade de xilana solubilizada. Houve uma tendência nos valores obtidos de glucana, conforme diminuiu o tamanho de partícula, aumentou o teor desse polissacarídeo no bagaço pré-tratado em meio ácido. Os valores variaram de 44,28 % (bagaço retido em peneira de 16 mesh) a 66,70 % (bagaço retido na peneira de 50 mesh). Para os materiais pré-tratados em meio alcalino retidos em peneiras de 40, 50 mesh e base ficaram acima do valor encontrado para o bagaço in natura. Considerando como uma característica importante da hemicelulose, todas as amostras apresentaram solubilidade acima de 96 %. A hidrólise enzimática do material pré-tratado em meio alcalino resultou em maior rendimento em glicose (65,37 % de glicose) para todas as frações/granulometrias estudadas, em comparação com meio ácido (32,12 % de glicose), mostrando tendência em aumento com diminuição da granulometria. Os resultados evidenciaram que a granulometria do bagaço de cana-de-açúcar tem influência na extração/solubilização de hemicelulose na forma de polissacarídeo (polimérica) e monossacarídeo (xilose). Conclui-se que, um melhor aproveitamento em conjunto da hemicelulose e celulose ocorreu com as condições experimentais de estudo do pré-tratamento alcalino. / The great capacity of sugar-alcohol agriculture, combined with its continental dimensions, makes Brazil the largest producer of sugar cane in the world. The bagasse of this raw material is a lignocellulosic material, reminiscent of the milling of its stems, is composed mainly of cellulose, hemicellulose and lignin, in an organized vegetable structure that must be destructured by means of pre-treatments to provide the polysaccharide fraction (cellulose and hemicellulose). The objective of this research was to determine the influence of sugarcane bagasse granulometry on the extraction/solubilization of hemicellulose in the form of polysaccharide (macromolecule) and monosaccharide (xylose). Macromolecular hemicellulose extraction was performed under optimized conditions for sugarcane bagasse, 6 % H2O2 m / v at 25 °C for 4 h, using bagasse selected in 16, 30, 40, 50 mesh sieves and base (material which passed through the 50 mesh screen). For the extraction of hemicellulose in the monomeric form, a pretreatment with sulfuric acid diluted 20 % (m/m) was used, and the samples were autoclaved at 121 ºC for 1 h; the xylose in the filtrate was quantified by HPLC. Conductivity, determination of total ash content and solubility of hemicellulose were also performed. The solid residues of the pre-treatments were submitted to enzymatic hydrolysis (12 FPU/g - Cellic Ctec) to determine the glucose yield. The bagasse in natura had glucan content of 42.25 %, arabinana of 2.62 %, xylan of 25.39 %, acetic acid of 3.38 % and lignin of 13.83 %. The solubilized xylan in alkaline medium showed a variation of 36.18 % (bagasse retained in the 16 mesh sieve) at 71.43 % (bagasse retained at the base, less than 50 mesh), the smaller the particle size, the greater the amount of solubilized xylan. There was a tendency in the values obtained of glucana, as the particle size decreased, the content of this polysaccharide increased in the acid treated bagasse. The values varied from 44.28 % (bagasse retained in 16 mesh sieve) to 66.70 % (bagasse retained in the 50 mesh sieve). For materials pretreated in alkaline medium retained in 40, 50 mesh and base sieves were above the value found for the in natura bagasse. Considering as an important characteristic of hemicellulose, all samples had solubility above 96 %. The enzymatic hydrolysis of the pretreated material in alkaline medium resulted in a higher glucose yield (65.37 % of glucose) for all fractions/granulometry studied, compared to acid medium (32.12 % glucose), showing a trend in increase with decreasing granulometry. The results showed that the sugarcane bagasse granulometry influences the extraction/solubilization of hemicellulose in the form of polysaccharide (polymeric) and monosaccharide (xylose). It was concluded that a better use of hemicellulose and cellulose occurred with experimental conditions of the alkaline pretreatment.
|
Page generated in 0.0674 seconds