• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 12
  • 12
  • 10
  • 10
  • 8
  • 8
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

SILVA, ERIC A.B. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:24Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
2

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

SILVA, ERIC A.B. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:24Z (GMT). No. of bitstreams: 0 / As câmaras de extrapolação são câmaras de ionização com volume variável e são utilizadas principalmente como detectores de radiação beta. Neste trabalho foram caracterizadas duas câmaras de extrapolação, uma comercial da marca PTW, e uma outra desenvolvida no Laboratório de Calibração do IPEN, para aplicação como sistemas de referência em feixes de mamografia, radiodiagnóstico convencional e radioterapia. Os resultados obtidos nos testes de caracterização da resposta das câmaras de extrapolação: corrente de fuga, estabilidade de curto e médio prazos, determinação das correntes de saturação e das eficiências de coleção de íons, dependência angular e energética, mostram que estas câmaras de extrapolação podem ser utilizadas em dosimetria de feixes de radiação X de energias baixas. Os fatores de transmissão no tecido e os fatores de calibração foram também determinados para todas as qualidades de radiação citadas. Finalmente, foi estabelecido um procedimento de calibração de detectores de radiação em feixes padronizados de radiação X, utilizando as câmaras de extrapolação. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
3

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

Silva, Eric Alexandre Brito da 31 March 2011 (has links)
As câmaras de extrapolação são câmaras de ionização com volume variável e são utilizadas principalmente como detectores de radiação beta. Neste trabalho foram caracterizadas duas câmaras de extrapolação, uma comercial da marca PTW, e uma outra desenvolvida no Laboratório de Calibração do IPEN, para aplicação como sistemas de referência em feixes de mamografia, radiodiagnóstico convencional e radioterapia. Os resultados obtidos nos testes de caracterização da resposta das câmaras de extrapolação: corrente de fuga, estabilidade de curto e médio prazos, determinação das correntes de saturação e das eficiências de coleção de íons, dependência angular e energética, mostram que estas câmaras de extrapolação podem ser utilizadas em dosimetria de feixes de radiação X de energias baixas. Os fatores de transmissão no tecido e os fatores de calibração foram também determinados para todas as qualidades de radiação citadas. Finalmente, foi estabelecido um procedimento de calibração de detectores de radiação em feixes padronizados de radiação X, utilizando as câmaras de extrapolação. / The extrapolation chambers are ionization chambers with variable volume, and they are mainly utilized as beta radiation detectors. In this work two extrapolation chambers were characterized, a commercial PTW extrapolation chamber and another extrapolation chamber developed at the Calibration Laboratory of IPEN, for application as reference systems in mammography, conventional diagnostic radiology and radiotherapy beams. The results obtained from the characterization tests of the chamber response: leakage current, short- and medium terms stability, determination of the saturation currents and the ion collection efficiencies, angular and energy dependence, show that these extrapolation chambers may be utilized for low-energy X radiation beam dosimetry. The transmission factors in tissue and the calibration factors were also determined for all cited radiation qualities. Finally, a procedure was established for calibration of radiation detectors in standard X radiation beams, using the extrapolation chambers.
4

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

Eric Alexandre Brito da Silva 31 March 2011 (has links)
As câmaras de extrapolação são câmaras de ionização com volume variável e são utilizadas principalmente como detectores de radiação beta. Neste trabalho foram caracterizadas duas câmaras de extrapolação, uma comercial da marca PTW, e uma outra desenvolvida no Laboratório de Calibração do IPEN, para aplicação como sistemas de referência em feixes de mamografia, radiodiagnóstico convencional e radioterapia. Os resultados obtidos nos testes de caracterização da resposta das câmaras de extrapolação: corrente de fuga, estabilidade de curto e médio prazos, determinação das correntes de saturação e das eficiências de coleção de íons, dependência angular e energética, mostram que estas câmaras de extrapolação podem ser utilizadas em dosimetria de feixes de radiação X de energias baixas. Os fatores de transmissão no tecido e os fatores de calibração foram também determinados para todas as qualidades de radiação citadas. Finalmente, foi estabelecido um procedimento de calibração de detectores de radiação em feixes padronizados de radiação X, utilizando as câmaras de extrapolação. / The extrapolation chambers are ionization chambers with variable volume, and they are mainly utilized as beta radiation detectors. In this work two extrapolation chambers were characterized, a commercial PTW extrapolation chamber and another extrapolation chamber developed at the Calibration Laboratory of IPEN, for application as reference systems in mammography, conventional diagnostic radiology and radiotherapy beams. The results obtained from the characterization tests of the chamber response: leakage current, short- and medium terms stability, determination of the saturation currents and the ion collection efficiencies, angular and energy dependence, show that these extrapolation chambers may be utilized for low-energy X radiation beam dosimetry. The transmission factors in tissue and the calibration factors were also determined for all cited radiation qualities. Finally, a procedure was established for calibration of radiation detectors in standard X radiation beams, using the extrapolation chambers.
5

Desenvolvimento de uma camara de extrapolacao como instrumento de referencia para dosimetria de radiacao beta

DIAS, SIMONE K. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:46Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:07Z (GMT). No. of bitstreams: 1 02805.pdf: 10911213 bytes, checksum: e5c497dd97a5ca4b85e4eb20a6347cd2 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
6

Desenvolvimento de um sistema de referencia e de uma metodologia para calibracao de aplicadores oftalmicos utilizados em braquiterapia

OLIVEIRA, MERCIA L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:14Z (GMT). No. of bitstreams: 1 10308.pdf: 5951521 bytes, checksum: c3f464af4f9a5b567dacd34287e1566f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP / FAPESP:01/00231-5
7

Estudo comparativo entre metodos de calibracao de aplicadores clinicos de radiacao beta / Comparative study among calibration methods of clinical applicators of beta radiation

ANTONIO, PATRICIA de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
8

Desenvolvimento de uma camara de extrapolacao como instrumento de referencia para dosimetria de radiacao beta

DIAS, SIMONE K. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:46Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:07Z (GMT). No. of bitstreams: 1 02805.pdf: 10911213 bytes, checksum: e5c497dd97a5ca4b85e4eb20a6347cd2 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
9

Desenvolvimento de um sistema de referencia e de uma metodologia para calibracao de aplicadores oftalmicos utilizados em braquiterapia

OLIVEIRA, MERCIA L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:14Z (GMT). No. of bitstreams: 1 10308.pdf: 5951521 bytes, checksum: c3f464af4f9a5b567dacd34287e1566f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP / FAPESP:01/00231-5
10

Estudo comparativo entre metodos de calibracao de aplicadores clinicos de radiacao beta / Comparative study among calibration methods of clinical applicators of beta radiation

ANTONIO, PATRICIA de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 0 / Os aplicadores clínicos de 90Sr+90Y são instrumentos utilizados em procedimentos de braquiterapia e devem ser calibrados periodicamente, de acordo com normas e recomendações internacionais. Neste trabalho, foram estudados quatro métodos de calibração de aplicadores dermatológicos e oftálmicos, comparando-se os resultados com os fornecidos pelos certificados de calibração dos fabricantes dos aplicadores. Os métodos envolveram o aplicador clínico padrão do Laboratório de Calibração de Instrumentos (LCI), calibrado pelo laboratório padrão primário americano do National Institute of Standards and Technology, como referência; um aplicador da Amersham, também pertencente ao LCI, como referência; uma mini-câmara de extrapolação desenvolvida no IPEN como padrão absoluto; e dosimetria termoluminescente. A mini-câmara de extrapolação e uma câmara de extrapolação comercial PTW foram estudadas com relação ao seu desempenho por meio de testes de controle de qualidade, como corrente de fuga, repetitividade e reprodutibilidade. A distribuição de dose em profundidade na água, estudo de grande importância na dosimetria de aplicadores clínicos, foi determinada utilizando-se a mini-câmara de extrapolação e dosímetros termoluminescentes. Os resultados obtidos foram considerados satisfatórios para os dois casos, quando comparados com os dados fornecidos pela norma IAEA (2002). Além disso, foi desenvolvido um sistema postal dosimétrico para a calibração de aplicadores clínicos por meio da técnica da termoluminescência, para ser enviado para clínicas e hospitais, sem a necessidade do transporte das fontes ao LCI do IPEN para calibração. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1492 seconds