• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Molecular analysis of ocular adnexal lymphomas in the search for potential biomarkers

Ma, Huan, 马欢 January 2011 (has links)
published_or_final_version / Anatomy / Doctoral / Doctor of Philosophy
2

Methods of Accurate 106Ru and 125I Eye Plaque Dosimetry Using Radiochromic Film in a Solid Water “Eye” Phantom and a Small Silicon Diode in a Water Tank

Trichter, Samuel January 2019 (has links)
Purpose: The use of 106Ru eye plaques for the treatment of intraocular malignancies has produced inconsistent clinical outcomes and has even resulted in treatment failures. I hypothesized that inconsistent clinical results were attributable to high uncertainties in 106Ru eye plaque dosimetry. Furthermore, I hypothesized that more accurate methods for assessing radiation dose from eye plaques would lead to more reliable treatment planning and therefore better overall clinical outcomes. Methods: A Solid Water “eye” phantom with several novel features was developed for radiochromic film eye plaque dosimetry. Films perpendicular to the central axis of the eye plaques were sandwiched between inserts in the phantom. Small holes in the inserts enabled the film to be marked with respect to the eye plaques, assuring exact geometrical co-registration. In cooperation with the manufacturer, special thin radiochromic films were developed and utilized to permit dosimetric measurements almost at the eye plaque surface. Precise film punches were developed for the purpose of cutting films with diameters as small as 8.5 mm and making cutouts in films without damaging the cut edges. Findings from a secondary dosimetry system, utilizing a small silicon diode in a water tank, were compared to film data. In addition to testing the new dosimetry methods with 106Ru eye plaques, which utilize high energy (MeV) β emissions, this approach was also applied to 125I containing eye plaques, which due to their inherently lower energy (keV) γ emission spectrum, raised additional dosimetric complications. In the latter case dosimetry, films and the diode were calibrated for absolute dosimetry using calibrated 125I seeds in Solid Water and water, respectively, applying the TG-43 formalism. A novel calibration method of radiochromic film for low-energy photon dosimetry was introduced. Monte Carlo simulations were used to convert the results measured in Solid Water to liquid water, and to compare measured and simulated dosimetric results. Results: Dosimetric characterization of both 106Ru eye plaques and a novel concept 125I eye plaque are described. Furthermore, dosimetry of a 20 mm 125I Collaborative Ocular Melanoma Study (COMS) eye plaque validated the presumed substantial dose reduction resulting from its gold alloy backing and seed carrier insert predicted by Monte Carlo simulations. Dose distributions measured with radiochromic film were in good agreement with diode measurements and Monte Carlo simulations. Replicate film results were reproducible from 0.9% to 5.5%. As little as 4% non-uniformities in planar dose rates were easily detected using 106Ru eye plaques. The novel 125I eye plaques had uniform dose distributions. Dosimetric characterization of the 20 mm COMS plaque demonstrated that the plaque’s dose rate was 15% lower than that predicted by homogenous TG-43 calculations. Lastly, Monte Carlo simulations indicated dose conversion factors between water and film in Solid Water compared to water and Solid Water alone differed by as much as 16.8%. Change in the calcium content of Solid Water from 2.3% to 1.7% resulted in a 3.3% calculated difference in dose to film and in an 8.7% difference in dose to Solid Water. Conclusions: Precise and reproducible 106Ru and 125I eye plaque dosimetry was achieved utilizing radiochromic film in a water equivalent phantom and a small semiconductor diode in water. Co-registration of eye plaques and films permitted not only precise treatment planning calculations along the central axis of the plaque, but also made it possible to account for dosimetric non-uniformities using 2D or 3D methodologies. A calibrated 125I seed enabled calibration of the film and the diode for absolute dosimetry of 125I containing eye plaques. Dose measurements on the inner surface of the plaques provided precise assessment of the scleral dose, its homogeneity, and of the active area of the plaques for coverage determination. Monte Carlo simulations facilitated conversion of doses measured in various media to liquid water.
3

Doseplanning ocular tumors with 125I-seeds

Bengtsson, Emil January 2006 (has links)
<p>Since 1986 patients with ocular malignant melanoma have been treated with Ru-106 plaques at S:t Erik Eye Hospital. In 1998 I-125 radioactive seed plaques was presented as an alternative to Ru-106 when treating tumors with an apical height greater than 7 mm. Until June 2005 the doseplanning of these plaques was based on a depth-dose curve made in the dose planning system Cadplan supplied by Varian Medical Systems. In the recent years the capabilities of computerized 3D dose planning system has increased greatly. The number of types of seeds on the market has also increased.</p><p>In order to implement the modern 3D dose planning system Brachy Vision 7.3.10 in planning the I-125 plaques, a review of the dose planning process have been done.</p><p>The ultra sound equipment used by the ophthalmologist to determine the apical height of the tumor has been investigated in terms of accuracy. A phantom has been developed for this task.</p><p>As new seeds entered the market a comparision have been made comparing the Amersham 6711 seed with the Bebig I25.S06 seed. A method for measuring the activity of the single seeds has also been developed.</p><p>The dose planning system Brachy Vision 7.3.10 have been compared to the old dose planning method, and an implementation of the plaques into Brachy Vision have been made.</p><p>The ultra sound equipment was accurate in the regions of interest. It was also discovered that the Bebig I25.S06 seed gave slightly higher dose compared to the Amersham 6711 with the same activity. The difference between the seeds is however small. The results indicate that the old dose planning method gave a slight underdosage.</p>
4

Doseplanning ocular tumors with 125I-seeds

Bengtsson, Emil January 2006 (has links)
Since 1986 patients with ocular malignant melanoma have been treated with Ru-106 plaques at S:t Erik Eye Hospital. In 1998 I-125 radioactive seed plaques was presented as an alternative to Ru-106 when treating tumors with an apical height greater than 7 mm. Until June 2005 the doseplanning of these plaques was based on a depth-dose curve made in the dose planning system Cadplan supplied by Varian Medical Systems. In the recent years the capabilities of computerized 3D dose planning system has increased greatly. The number of types of seeds on the market has also increased. In order to implement the modern 3D dose planning system Brachy Vision 7.3.10 in planning the I-125 plaques, a review of the dose planning process have been done. The ultra sound equipment used by the ophthalmologist to determine the apical height of the tumor has been investigated in terms of accuracy. A phantom has been developed for this task. As new seeds entered the market a comparision have been made comparing the Amersham 6711 seed with the Bebig I25.S06 seed. A method for measuring the activity of the single seeds has also been developed. The dose planning system Brachy Vision 7.3.10 have been compared to the old dose planning method, and an implementation of the plaques into Brachy Vision have been made. The ultra sound equipment was accurate in the regions of interest. It was also discovered that the Bebig I25.S06 seed gave slightly higher dose compared to the Amersham 6711 with the same activity. The difference between the seeds is however small. The results indicate that the old dose planning method gave a slight underdosage.

Page generated in 0.0293 seconds