1 |
Development of Ambient Mass Spectrometry for The Detection of Drug and Small Biological CompoundLiu, Jia-jiun 11 July 2007 (has links)
none
|
2 |
Fused-Droplet Electrospray Ionization Mass Spectrometry Combined with Pyrolysis for Polarity and Organic Composition of Soil, Tobacco,and Humic AcidLi, Kuang-Feng 09 August 2004 (has links)
none
|
3 |
noneHong, Sheng-Peng 27 June 2002 (has links)
none
|
4 |
Fused-Droplet Electrospray Ionization Mass Spectrometry Combined with Pyrolysis for Polymers AnalysisChen, Ming-Fong 17 July 2002 (has links)
none
|
5 |
Eliminating Interference of Organic salt and Surfactant in Protein Analysis by Fused-Droplet Electrospray Ionization Mass SpectrometryShieh, Yi-Fan 22 June 2003 (has links)
none
|
6 |
Development of Temperature-Controlled Fused-Droplet Electrospray Ionization MassSpectrometry and Its Application in the Analysis of BiomolecularTsao, Chia-Chi 23 June 2003 (has links)
none
|
7 |
Millisecond H/D Exchange Combined with Electrospray Ionization Mass Spectrometry to Study Protein¡¦s StructureLin, Hsuan-Chung 03 August 2004 (has links)
none
|
8 |
Fabrication of Integrated Nebulizer Nozzle Plate Utlizing Micro-molding for FD- ESI Mass SpectrometryChang, Chien-chung 01 July 2005 (has links)
This study presents a novel concept to integrated nebulizer nozzle plate for FD-ESI (Fused-droplet Electrospary Ionization Mass Spectrometry) using modified LIGA process. This fabrication technique can reduce the production cost of current nozzle plate. It comprises of multi-exposure and single develop (MESD) process, the extra-hard Ni-Co (Nickel-Cobalt) electroforming and thin-wall plastic microinjection molding. The template of nozzle plate is patterned using dry film and MESD process. Later, the template is transferred into metal Ni-Co mold by electroplating. In this study, the technique of extra-hard Ni-Co alloy electroplating process with Hardness of Vickers over (HV) 550 is developed. Then with the stiffness of Ni-Co mold, it can withstand high injection speed. Thin-wall microinjection molding process with short cycle time to fabricate nozzle plate can be finished. Liquid crystal polymer (LCP) is used for thin-wall microinjection molding process. In order to make efficiently atomization, we used ANSYS to optimize PZT actuator. Besides, the work of nebulizer with FD-ESI was demonstrated in this study. a novel design of nozzle plate.
|
9 |
Millisecond H/D Exchange Combined with Electrospray Ionization Mass Spectrometry to Study Three Dimensional Structure of ProteinHuang, Ming-Wei 23 June 2003 (has links)
none
|
Page generated in 0.0175 seconds