• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude dosimétrique et modélisation des composantes de la dose à distance pour les faisceaux d'électrons en radiothérapie externe / dosimetric study and modeling of electron beams components from electron beams used in external radiotherapy

Mohamad alabdoaburas, Mohamad 30 March 2017 (has links)
Les améliorations dans les procédures cliniques de radiothérapie ont conduit à des taux de survie élevés. En conséquence, les effets secondaires possibles de la dose délivrée aux tissus sains sont devenus une préoccupation croissante pour les radiothérapeutes. L’estimation de la dose aux tissus sains, y compris à distance du volume-cible présente un intérêt clinique croissant pour évaluer le risque aux structures sensibles situées hors du champ d’irradiation. Nos travaux antérieurs se sont focalisés sur l’évaluation la dose à distance des faisceaux de photons. La dose à distance due aux faisceaux d’électrons n’a jamais été prise en compte, ce qui peut conduire à des sous-estimations des doses à distance lorsque le traitement est fait entièrement ou partiellement par les électrons. C’est la raison pour laquelle, une étude approfondie de la dose à distance des faisceaux d’électrons est devenue indispensable. Dans le présent travail de thèse, nous avons dans un premier temps réalisé une étude expérimentale décrivant la dose à distance des faisceaux d’électrons de haute énergie produits par différents accélérateurs linéaires, équipés de différents types d’applicateurs. Nous avons analysé l’influence de différents paramètres du faisceau sur la dose à distance dont l’énergie du faisceau, la taille et le type de l’applicateur, la distance à l’axe du faisceau ainsi que la profondeur dans l’eau. Nous avons séparé la dose à distance en deux composantes principales : la dose due aux photons de bremsstrahlung et la dose due aux électrons diffusés. Ensuite, nous avons développé un modèle pour le calcul de la composante de la dose due aux photons de bremsstrahlung en tout point dans le patient, et un modèle pour le calcul de la dose due aux électrons diffusés en dehors du champ d’irradiation. Enfin, nous avons évalué l’application de nos modèles de calcul de dose à distance dans une situation clinique réelles afin de démontrer l’intérêt clinique de notre modélisation, l’objectif étant de mettre un point à terme, un outil logiciel innovant répondant à la fois aux besoins de l’optimisation de la radiothérapie moderne et à ceux de l’épidémiologie de la dose comme facteur de risque d’effets iatrogènes. / The large improvements in the radiotherapy (RT) procedures have led to high survival rates. So the possible side late effects of the radiotherapy due to the doses deposited into the normal tissues have become a growing concern for the radio-oncologists. The assessment of the dose outside the radiation field presents an important clinical benefit for estimating the risk at sensible structures situated partially or entirely outside the radiation field, especially in pediatric, pregnant patients or the patients having cardiac implantable devices. More understanding of side effects of RT will require not only improved control of the high doses delivered to the target volumes, but also better knowledge of the unintended but unavoidable lower doses delivered out of the target. In this context, most studies on out-of-field dose estimation focus on photon beams. Nevertheless, electron beams are still an important component of RT, for treating superficial tumors (at depths < 5 cm). The out-of-field dose from electron beams has never been taken account, which causes an under estimation of this dose when the radiotherapy is done only or partly by the electrons. For this reason, a detailed investigation of the out-of-field dose from electron beams is essential for better estimation of the out-of-field dose regardless the radiotherapy type. In this thesis, we have experimentally evaluated the out-of-field doses in high-energy electron beams for three linear accelerators equipped with different electron applicator types used in daily practice. The dependence of this dose on different parameters, such as the applicator size, the electron beam energy, the depth, and the off-axis distance have been investigated. The scattered electrons component and the bremsstrahlung photons component have been separated by a semi-experimental method. We have developed a multi-source model based on existing multi-scattering models for calculating the bremsstrahlung dose distribution at any point in the patient inside and outside the radiation field. We have also analytically calculated the scattered electrons dose distribution outside the radiation field. These two models permit to calculate the total out-of-field dose from electron beams anywhere in the patient. Finally, we have evaluated the application of our models of dose calculation in a real clinical situation in order to validate our software, the aim being to set up an innovative software tool, meeting both the needs of radiotherapy and epidemiology of the dose as a risk factor for iatrogenic effects
2

Evaluation de la dose déposée par des faisceaux d'électrons en radiothérapie dans des fantômes voxelisés en utilisant la plateforme de simulation Monte Carlo GATE fondée sur GEANT4 dans un environnement de grille / Evaluation of the dose deposited by electron beams in radiotherapy in voxelized phantoms using the Monte Carlo GATE simulation platform based on GEANT4 in a grid environment

Perrot, Yann 08 December 2011 (has links)
La planification de traitement en radiothérapie nécessite un calcul précis de la dose délivrée au patient. La méthode la plus fiable pour y parvenir est la simulation du transport des particules par technique Monte Carlo. Cette thèse constitue la première étude concernant la validation de la plateforme de simulation Monte Carlo GATE (GEANT4 Application for Tomographic Emission), basée sur les librairies de GEANT4 (GEometry ANd Tracking), pour le calcul de la dose absorbée déposée par des faisceaux d’électrons. L’objectif de cette thèse est de montrer que GATE/GEANT4 est capable d’atteindre le niveau d’exigences requis pour le calcul de la dose absorbée lors d’une planification de traitement, dans des situations où les algorithmes analytiques, actuellement utilisés dans les services de radiothérapie, n’atteignent pas un niveau de précision satisfaisant. L’enjeu est de prouver que GATE/GEANT4 est adapté pour la planification de traitement utilisant des électrons et capable de rivaliser avec d’autres codes Monte Carlo reconnus. Cet enjeu a été démontré par la simulation avec GATE/GEANT4 de faisceaux et des sources d’électrons réalistes utilisées en radiothérapie externe ou en radiothérapie moléculaire et la production de distributions de dose absorbée en accord avec les mesures expérimentales et avec d’autres codes Monte Carlo de référence pour la physique médicale. Par ailleurs, des recommandations quant à l’utilisation des paramètres de simulation à fixer, assurant un calcul de la distribution de dose absorbée satisfaisant les spécifications en radiothérapie, sont proposées. / Radiation therapy treatment planning requires accurate determination of absorbed dose in the patient. Monte Carlo simulation is the most accurate method for solving the transport problem of particles in matter. This thesis is the first study dealing with the validation of the Monte Carlo simulation plateform GATE (GEANT4 Application for Tomographic Emission), based on GEANT4 (GEometry And Tracking) libraries, for the computation of absorbed dose deposited by electron beams. This thesis aims at demonstrating that GATE/GEANT4 calculations are able to reach treatment planning requirements in situations where analatycal algorithms are not satisfactory. The goal is to prove that GATE/GEANT4 is useful for treatment planning using electrons and competes with well validated Monte Carlo codes. This is demonstrated by the simulations with GATE/GEANT4 of realistic electron beams and electron sources used for external radiation therapy or targeted radiation therapy. The computed absorbed dose distributions are in agreement with experimental measurements and/or calculations from other Monte Carlo codes. Furthermore, guidelines are proposed to fix the physics parameters of the GATE/GEANT4 simulations in order to ensure the accuracy of absorbed dose calculations according to radiation therapy requirements.
3

Ionisation par faisceau d'électrons de solutions aqueuses de benzènesulfonate et naphthalènesulfonate et sous-produits / Ionization by electron beam of aqueous solutions of naphthalenesulfonate, benzenesulfonate and by-products

Alkhuraiji, Turki 17 April 2013 (has links)
Ce sujet entre dans le cadre de l'étude d'un procédé d'oxydation avancé innovant dans le domaine de la dépollution des eaux, à savoir l'ionisation par faisceau d'électrons. Le radical hydroxyle (•OH) et l'électron hydraté (e−aq) sont les deux espèces majoritaires issues de l'ionisation de solutions aqueuses par un faisceau d'électrons d'intense énergie. Il a été démontré que la génération des radicaux supplémentaires tels que le radical sulfate (SO4•−) et le radical hydroxyle par les réactions radicalaires entre l'ion persulfate, le peroxyde d'hydrogène et l'électron hydraté respectivement, améliore l'efficacité de ce procédé pour la dégradation de polluants organiques en solution aqueuse. Dans le présent travail, la dégradation et la minéralisation de benzènesulfonate et naphthalènesulfonate de sodium, et d'acide gallique ont été obtenues par irradiation par faisceau d'électrons seul et couplé avec un oxydant (S2O8−−, H2O2). En absence d'oxydant une dose absorbée de 1,5 kGy a été suffisante pour l'élimination totale de ces composés. La présence d'oxydant permet généralement de réduire les doses d'irradiation nécessaires. Par ailleurs, l'augmentation de la concentration en oxydant ou de la dose appliquée a un effet bénéfique vis-à-vis de l'élimination du carbone organique. Cependant, le couplage S2O8−−/faisceau d'électrons est plus adapté que le couplage H2O2/faisceau d'électrons même en présence de constituants inorganiques. Les résultats obtenus soulignent l'importance du rôle du dioxygène dissous lors de l'étape de la minéralisation en vue de favoriser la formation des radicaux organiques (ROO•). Pour chaque une des molécules étudiées, des sous-produits d'oxydation... / This research belongs to the study of the ionization of aqueous solutions by electron beam (E.B.) as an advanced oxidation process for water treatment. The hydroxyl radical (•OH) and hydrated electron(eaq¯) are the two major active species produced from the ionization of aqueous solutions by high energy electron beam. It has been shown that the generation of additional radicals such as the sulphate radical (SO4•¯) and hydroxyl radical from the reaction of persulfate ion (S2O8¯) or hydrogen peroxide (H2O2) with the hydrated electron, improved the efficiency of this process towards the degradation and mineralization of organic pollutants in aquaeous solution. In the présent work, the degradation and mineralization of naphthalenesulfonate, benzenesulfonate and gallic acid were studied by electron beam irradiation alone and coupled with oxidants (S2O8¯, H2O2).In the absence of oxidant, an absorbed dose of 1,5 kGy leads to total elimnation of these pollutants. The presence of added oxidants usually reduces the radiation dose required. In addition, increasing oxidant concentration or applied dose had a beneficial effect towards the organic carbon removal. It was found that coupling E.B./S2O8¯ has more suitable than E.B./ H2O2 even in the presence of inorganic constituents. The results also highlighted the importance of dissolved oxygen in the system when mineralization is aimed. For each of the molecules studied, oxidation by-products resulting from hydroxylation and aromatic ring opening were identified.
4

Theoretical study of Ultra High Intensity laser-produced high-current relativistic electron beam transport through solid targets / Etude théorique de la propagation de faisceaux intenses d’électrons relativistes généré par lasers à grandes intensités

Debayle, Arnaud 04 December 2008 (has links)
Cette thèse porte sur l’étude théorique du transport d’un faisceau intense d’électrons relativistes dans une cible solide. Dans la première partie nous présentons les interprétations théoriques d’une partie des résultats d’une campagne d’expérience portant sur la production et le transport d’électrons relativistes dans une cible d’aluminium. Nous y démontrons la prédominance des e?ets collectifs sur les e?ets collisionels dans la première dizaine de microns de propagation grâce à des modèles de transports déjà existant au début de cette thèse. Ces modèles deviennent insu?sants dans le cas du transport de faisceau dans un isolant. Aussi, dans la deuxième partie, nous présentons un modèle de propagation du faisceau d’électrons relativistes dans un diélectrique incluant l’e?et de l’ionisation de la cible par le faisceau. Nous y quanti?ons les pertes d’énergies des électrons en fonction des paramètres du faisceau et du milieu environnant, et nous démontrons l’existence d’un régime de propagation pour lequel les électrons du plasma ne sont pas à l’équilibre thermodynamique local avec les ions. Ces résultats ont été comparés et con?rmés avec un code cinétique qui prend en compte l’ionisation par champ électrique et par collisions entre les électrons du plasma et les ions. Nous avons examiné la stabilité du faisceau et montré que ce dernier pouvait exciter deux types d’instabilités transverses sur des longueurs de propagation de l’ordre de 30 à 300 µm en fonction de la taille de la perturbation. / This PhD thesis is a theoretical study of high-current relativistic electron beam transport through solid targets. In the ?rst part, we present an interpretation of a part of experimental results of laser– produced electron beam transport in aluminium foil targets. We have estimated the fast electron beam characteristics and we demonstrated that the collective e?ects dominate the transport in the ?rst tens of µm of propagation. These quantitative estimates were done with the transport models already existing at the beginning of this thesis. These models are no longer su?cient in the case a fast electron beam propagation in insulator targets. Thus, in the second part, we have developed a propagation model of the beam that includes the e?ects of electric ?eld ionization and the collisional ionization by the plasma electrons. We present estimates of the electron energy loss induced by the target ionization, and we discuss its dependence on the beam and target parameters. In the case of a relatively low fast electron density, we demonstrated that the beam creates a plasma where the electons are not in a local thermodynamic equilibrium with ions. We have examined the beam stability and we demonstrated that transverse instabilities can be excited by the relativistic electron beam over the propagation distances of 30 - 300 µm depending on the perturbation wavelength.

Page generated in 0.0659 seconds