• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Proteção diferencial de transformadores de potência utilizando a transformada Wavelet com efeitos de borda

Medeiros, Rodrigo Prado de 21 December 2017 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-04-11T20:06:39Z No. of bitstreams: 1 RodrigoPradoDeMedeiros_TESE.pdf: 23526132 bytes, checksum: 52eacda3bf132cc7b21e6f712b970cc0 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-04-16T22:03:49Z (GMT) No. of bitstreams: 1 RodrigoPradoDeMedeiros_TESE.pdf: 23526132 bytes, checksum: 52eacda3bf132cc7b21e6f712b970cc0 (MD5) / Made available in DSpace on 2018-04-16T22:03:49Z (GMT). No. of bitstreams: 1 RodrigoPradoDeMedeiros_TESE.pdf: 23526132 bytes, checksum: 52eacda3bf132cc7b21e6f712b970cc0 (MD5) Previous issue date: 2017-12-21 / O Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A função diferencial é largamente utilizada na proteção de transformadores de potência, levando a uma discriminação confiável entre faltas internas e outros eventos associados à operação do transformador. No entanto, a função de proteção diferencial convencional baseada na estimação de fasores de corrente apresenta dificuldades na detecção de algumas faltas internas, tais como faltas espira-espira e espira-terra próximos ao neutro do transformador, e dependência das funções de bloqueio e de restrição por harmônicos na manutenção da segurança do esquema de proteção durante condições de inrush, sobreexcitação do transformador e faltas externas com saturação do transformador de corrente. Para melhorar o desempenho e a confiabilidade dos métodos tradicionais, um elemento de sequência negativa de alta sensibilidade tem sido utilizado em conjunto com as funções de bloqueio e restrição por harmônicos. Por outro lado, faltas internas e demais distúrbios associados à proteção de transformadores apresentam transitórios, os quais podem ser detectados de forma adequada pela transformada wavelet. Propõe-se neste trabalho recriar os tradicionais elementos diferenciais de corrente de fase e de sequência negativa por meio da utilização da transformada wavelet discreta redundante com efeitos de bordas das correntes que fluem nos enrolamentos secundários dos TCs ligados em conexão diferencial. O método proposto foi avaliado, quanto aos índices de desempenho de taxa de sucesso e tempo de operação, para simulações extensivas de faltas internas, faltas externas, saturações do TC, faltas simultâneas e energizações do transformador na ausência e na presença de falta, e o seu desempenho foi comparado com o de um esquema de proteção diferencial clássico. O método proposto foi bastante rápido, reduzindo o tempo de operação da proteção de alguns milissegundos para alguns microsegundos, confiável, seguro, simples (apenas duas funções diferenciais), imune ao ruído e apresentou um pequeno esforço computacional quando da sua implementação em um processador para aplicações em tempo real. Os resultados obtidos revelaram as vantagens da utilização da transformada wavelet na proteção diferencial em relação à proteção convencional, e critérios exigidos em sistemas de proteção, tais como confiabilidade, segurança e velocidade foram devidamente atendidos. / The differential function is widely used in power transformer protection, leading to a reliable discrimination between internal faults and other events associated with power transformer operation. However, the conventional differential protection function based on the estimation of current phasors presents difficulties in the detection of some internal faults, such as turn-to-turn faults and turn-to-earth faults close to the transformer neutral, and dependence on the harmonic restraint and harmonic blocking functions in maintaining protection scheme security during inrush conditions, overeexcitation, and external faults with current transformer saturation. In order to improve the performance of the traditional methods, a negative sequence differential element with high sensitivity has been used in association with the commom harmonic blocking and harmonic restraint functions. However, internal faults and other disturbances associated to the power transformer protection present transients, which can be properly detected by using the wavelet transform. This paper proposes recreate the traditional phase and negative sequence current differential elements by using the boundary discrete wavelet transform of the currents flowing through the secondary winding of the CTs connected in differential connection. The proposed method was evaluated for the success rate and operating time performance indices for extensive simulations of internal faults, external faults, CT saturations, crosscountry faults and transformer energizations in the absence and presence of fault, and its performance was compared to that of a classical differential protection scheme. The proposed method was very fast, reducing the protection operation time from a few milliseconds to some microseconds, reliable, safe, simple (only two differential functions), immune to noise and presented a low computational burden when implemented in a digital signal processor for real-time application purposes. The results obtained revealed the advantages of use of the wavelet transform in the differential protection in relation to conventional protection, and criteria required in protection systems, such as reliability, safety and speed, have been adequately met.
2

Prote??o diferencial de transformadores de pot?ncia utilizando a transformada Wavelet

Medeiros, Rodrigo Prado de 26 May 2014 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2015-10-01T13:21:43Z No. of bitstreams: 1 RodrigoPradoDeMedeiros_DISSERT.pdf: 23036779 bytes, checksum: a7e3d6bc86f0611a2e27faca2dc99a1e (MD5) / Approved for entry into archive by Elisangela Moura (lilaalves@gmail.com) on 2015-10-01T13:35:05Z (GMT) No. of bitstreams: 1 RodrigoPradoDeMedeiros_DISSERT.pdf: 23036779 bytes, checksum: a7e3d6bc86f0611a2e27faca2dc99a1e (MD5) / Made available in DSpace on 2015-10-01T13:35:05Z (GMT). No. of bitstreams: 1 RodrigoPradoDeMedeiros_DISSERT.pdf: 23036779 bytes, checksum: a7e3d6bc86f0611a2e27faca2dc99a1e (MD5) Previous issue date: 2014-05-26 / Cerca de 10% das faltas envolvendo o sistema el?trico ocorrem em transformadores de pot?ncia. Portanto, a prote??o aplicada aos transformadores de pot?ncia ? essencial para garantir o funcionamento cont?nuo desse dispositivo e a efici?ncia do sistema el?trico. Dentre as fun??es de prote??o aplicadas em transformadores, a prote??o diferencial aparece como um dos principais esquemas, apresentando confi?vel discrimina??o entre faltas internas e faltas externas ou condi??es de carregamento nominal do sistema. Por?m, a principal dificuldade dos m?todos de prote??o convencional consiste na demora para detec??o dos eventos. Contudo, faltas internas, faltas externas e os demais eventos apresentam transit?rios, podendo ser apropriadamente analisados pela transformada wavelet. Neste trabalho ? proposto o desenvolvimento de um esquema de prote??o diferencial de transformadores baseado na transformada wavelet para detec??o e identifica??o de faltas externas, faltas internas e energiza??o do transformador usando a energia dos coeficientes wavelets das correntes diferenciais. Os resultados revelam as vantagens da utiliza??o da transformada wavelet na prote??o diferencial em rela??o ? prote??o convencional, uma vez que ela prov? confiabilidade e rapidez na detec??o desses eventos. / About 10% of faults involving the electrical system occurs in power transformers. Therefore, the protection applied to the power transformers is essential to ensure the continuous operation of this device and the efficiency of the electrical system. Among the protection functions applied to power transformers, the differential protection appears as one of the main schemes, presenting reliable discrimination between internal faults and external faults or inrush currents. However, when using the low frequency components of the differential currents flowing through the transformer, the main difficulty of the conventional methods of differential protection is the delay for detection of the events. However, internal faults, external faults and other disturbances related to the transformer operation present transient and can be appropriately detected by the wavelet transform. In this paper is proposed the development of a wavelet-based differential protection for detection and identification of external faults to the transformer, internal faults, and transformer energizing by using the wavelet coefficient energy of the differential currents. The obtained results reveal the advantages of using of the wavelet transform in the differential protection compared to conventional protection, since it provides reliability and speed in detection of these events.
3

Lógica fuzzy aplicada na melhoria da proteção digital de geradores síncronos / Fuzzy logic applied in synchronous generators digital protection improvement

Renato Machado Monaro 28 February 2013 (has links)
Este trabalho propõe um novo método de proteção de geradores síncronos baseado em inteligência artificial, mais especificamente lógica fuzzy, com o propósito de melhorar a proteção destes componentes vitais aos sistema elétricos de potência. Um sistema elétrico de potência completo composto por geradores, linhas de transmissão e cargas foi simulado através do Real Time Digital Simulator para fornecer dados para realização de testes e validação do algoritmo de proteção inteligente. Adicionalmente, foram desenvolvidos dois esquemas experimentais que proporcionaram a obtenção de um conjunto extensivo de ensaios de faltas internas em dois geradores síncronos reais, com o objetivo de fornecer dados para comprovar a eficácia da proteção proposta. Um sistema integrado de software e hardware cujo objetivo é servir de plataforma para desenvolver e executar em tempo real algoritmos de proteção aplicados foi desenvolvido. Esse sistema integrado foi utilizado nos testes embarcados em tempo-real do algoritmo de proteção desenvolvido. Apresenta-se também um arranjo composto por funções de proteção tradicionais mais utilizadas em campo, as quais serviram como base de comparação de desempenho para o esquema de proteção inteligente desenvolvido. Os resultados apresentados mostram que o método de proteção inteligente proposto é mais sensível para detectar instantaneamente faltas fase-terra em geradores síncronos com aterramento de alta-impedância, além de ser capaz de identificar faltas entre-espiras e entre-caminhos / This work presents the development of a synchronous generator protective technique based on artificial intelligence, specifically fuzzy logic, in order to improve the protection of these vital components of the electric power system. A complete electric power system composed of generators, transmission lines and loads was simulated using the Real Time Digital Simulator to provide data for testing and validating the intelligent protection algorithm. Additionally, an extensive set of internal fault experiments conducted on two actual synchronous generators provided oscillograms to demostrate the proposed protection effectiveness. An integrated hardware and software system whose purpose is to serve as a platform for developing and executing real-time protection algorithms is presented. This integrated system was used for real-time embedded testing of the protection algorithm developed. An arrangement composed of traditional protection functions most used in the field is also presented, this arrangement served as a comparison basis for the intelligent protection scheme performance. The results show that the intelligent protection is more sensitive to detect instantly ground faults in synchronous generators with high-impedance grounding, it is also shown that the proposed scheme is able to identify inter-turns and inter-circuits faults
4

Lógica fuzzy aplicada na melhoria da proteção digital de geradores síncronos / Fuzzy logic applied in synchronous generators digital protection improvement

Monaro, Renato Machado 28 February 2013 (has links)
Este trabalho propõe um novo método de proteção de geradores síncronos baseado em inteligência artificial, mais especificamente lógica fuzzy, com o propósito de melhorar a proteção destes componentes vitais aos sistema elétricos de potência. Um sistema elétrico de potência completo composto por geradores, linhas de transmissão e cargas foi simulado através do Real Time Digital Simulator para fornecer dados para realização de testes e validação do algoritmo de proteção inteligente. Adicionalmente, foram desenvolvidos dois esquemas experimentais que proporcionaram a obtenção de um conjunto extensivo de ensaios de faltas internas em dois geradores síncronos reais, com o objetivo de fornecer dados para comprovar a eficácia da proteção proposta. Um sistema integrado de software e hardware cujo objetivo é servir de plataforma para desenvolver e executar em tempo real algoritmos de proteção aplicados foi desenvolvido. Esse sistema integrado foi utilizado nos testes embarcados em tempo-real do algoritmo de proteção desenvolvido. Apresenta-se também um arranjo composto por funções de proteção tradicionais mais utilizadas em campo, as quais serviram como base de comparação de desempenho para o esquema de proteção inteligente desenvolvido. Os resultados apresentados mostram que o método de proteção inteligente proposto é mais sensível para detectar instantaneamente faltas fase-terra em geradores síncronos com aterramento de alta-impedância, além de ser capaz de identificar faltas entre-espiras e entre-caminhos / This work presents the development of a synchronous generator protective technique based on artificial intelligence, specifically fuzzy logic, in order to improve the protection of these vital components of the electric power system. A complete electric power system composed of generators, transmission lines and loads was simulated using the Real Time Digital Simulator to provide data for testing and validating the intelligent protection algorithm. Additionally, an extensive set of internal fault experiments conducted on two actual synchronous generators provided oscillograms to demostrate the proposed protection effectiveness. An integrated hardware and software system whose purpose is to serve as a platform for developing and executing real-time protection algorithms is presented. This integrated system was used for real-time embedded testing of the protection algorithm developed. An arrangement composed of traditional protection functions most used in the field is also presented, this arrangement served as a comparison basis for the intelligent protection scheme performance. The results show that the intelligent protection is more sensitive to detect instantly ground faults in synchronous generators with high-impedance grounding, it is also shown that the proposed scheme is able to identify inter-turns and inter-circuits faults
5

Ajuste e ensaio de sistemas de proteção de geradores síncronos. / Regeneration of productive systems through dynamic reallocation of resources with functional flexibility.

Omar Chayña Chayña Velásquez 28 May 2015 (has links)
Os sistemas de proteção dos elementos da rede elétrica desempenham um papel de fundamental importância na segurança e confiabilidade dos sistemas de potência. A não atuação ou a atuação incorreta dos relés de proteção durante uma falta localizada em um componente da rede pode transformar-se em um evento sistêmico de grandes proporções (blecaute). Esses eventos trazem riscos e elevados prejuízos econômicos à sociedade. A proteção dos geradores síncronos, apesar do alto custo e complexidade deste tipo de equipamento, não recebe a mesma atenção na literatura que a dedicada à proteção de outros elementos da rede, como, por exemplo, a das linhas de transmissão. Isso decorre do menor número de geradores existentes na rede e também da ideia que as faltas neste tipo de equipamento são menos frequentes. Este trabalho aborda os principais aspectos envolvidos com o projeto de um sistema de proteção para geradores síncronos de grande porte. Incialmente, discutese os principais conceitos associados com os geradores, de interesse para a tarefa de proteção. Particular atenção é dedicada às formas de aterramento e aos critérios adotados para projeto do resistor de aterramento utilizado nesse equipamento. Em seguida, apresentam-se as principais funções de proteção aplicáveis aos geradores, particularmente aquelas voltadas para a detecção de faltas nos enrolamentos do estator. Discute-se também os critérios de ajustes dos parâmetros dessas funções. Descreve-se o uso de uma plataforma laboratorial, baseada em simulador de tempo real (RTDS), para ensaio e análise do sistema de proteção visando validar seu correto desempenho frente às possíveis condições operativas que podem ser encontradas em campo. Finalmente, utilizando os conceitos desenvolvidos ao longo do trabalho, desenvolve-se um estudo de caso, onde é realizado o projeto e implementação do sistema de proteção dos geradores de uma usina hidrelétrica hipotética. Para avaliar e analisar o desempenho do sistema de proteção dessa rede exemplo, parametrizou-se o IED G60 (GE) e realizou-se inúmeras simulações na plataforma de testes proposta. / Protection systems play a critical role in the safety and reliability of electric power systems. The non-operation or wrong operation of protective relays during a fault in a network element can evolve to a systemic event in large scale (blackout). These events bring risks and high economic losses to society. Despite the high cost and complexity, the protection of synchronous generators has not received much attention in the literature devoted to protection of other network elements, such as transmission lines. This stems from the smaller number of generators in the network and also the idea that the faults in this type of equipment are less frequent. This research discusses the main aspects involved in the design of a protection system for large synchronous generators. Initially, it discusses the key concepts of interest to the generation protection. Particular attention is given to grounding techniques and the criteria adopted for the design of grounding resistors used in those equipment. Then the main protection functions applicable to generators are presented, particularly those related to fault detection in the stator windings. The criteria for setting the parameters of these functions are also discussed. After that, the use of a laboratory shelf, based on Real-Time Digital Simulator (RTDS) for testing and analysis of the protection system, is described in order to validate the correct performance in face of possible operating conditions in the field. Finally, a study case is developed using the concepts developed throughout the research. Then, the design and implementation of the protection system of generators of a hypothetical hydroelectric plant are carried out. To evaluate and analyze the performance of this example network protection system, parameterized up IED G60 (GE) and held numerous simulations in the proposed test platform.
6

Ajuste e ensaio de sistemas de proteção de geradores síncronos. / Regeneration of productive systems through dynamic reallocation of resources with functional flexibility.

Chayña Velásquez, Omar Chayña 28 May 2015 (has links)
Os sistemas de proteção dos elementos da rede elétrica desempenham um papel de fundamental importância na segurança e confiabilidade dos sistemas de potência. A não atuação ou a atuação incorreta dos relés de proteção durante uma falta localizada em um componente da rede pode transformar-se em um evento sistêmico de grandes proporções (blecaute). Esses eventos trazem riscos e elevados prejuízos econômicos à sociedade. A proteção dos geradores síncronos, apesar do alto custo e complexidade deste tipo de equipamento, não recebe a mesma atenção na literatura que a dedicada à proteção de outros elementos da rede, como, por exemplo, a das linhas de transmissão. Isso decorre do menor número de geradores existentes na rede e também da ideia que as faltas neste tipo de equipamento são menos frequentes. Este trabalho aborda os principais aspectos envolvidos com o projeto de um sistema de proteção para geradores síncronos de grande porte. Incialmente, discutese os principais conceitos associados com os geradores, de interesse para a tarefa de proteção. Particular atenção é dedicada às formas de aterramento e aos critérios adotados para projeto do resistor de aterramento utilizado nesse equipamento. Em seguida, apresentam-se as principais funções de proteção aplicáveis aos geradores, particularmente aquelas voltadas para a detecção de faltas nos enrolamentos do estator. Discute-se também os critérios de ajustes dos parâmetros dessas funções. Descreve-se o uso de uma plataforma laboratorial, baseada em simulador de tempo real (RTDS), para ensaio e análise do sistema de proteção visando validar seu correto desempenho frente às possíveis condições operativas que podem ser encontradas em campo. Finalmente, utilizando os conceitos desenvolvidos ao longo do trabalho, desenvolve-se um estudo de caso, onde é realizado o projeto e implementação do sistema de proteção dos geradores de uma usina hidrelétrica hipotética. Para avaliar e analisar o desempenho do sistema de proteção dessa rede exemplo, parametrizou-se o IED G60 (GE) e realizou-se inúmeras simulações na plataforma de testes proposta. / Protection systems play a critical role in the safety and reliability of electric power systems. The non-operation or wrong operation of protective relays during a fault in a network element can evolve to a systemic event in large scale (blackout). These events bring risks and high economic losses to society. Despite the high cost and complexity, the protection of synchronous generators has not received much attention in the literature devoted to protection of other network elements, such as transmission lines. This stems from the smaller number of generators in the network and also the idea that the faults in this type of equipment are less frequent. This research discusses the main aspects involved in the design of a protection system for large synchronous generators. Initially, it discusses the key concepts of interest to the generation protection. Particular attention is given to grounding techniques and the criteria adopted for the design of grounding resistors used in those equipment. Then the main protection functions applicable to generators are presented, particularly those related to fault detection in the stator windings. The criteria for setting the parameters of these functions are also discussed. After that, the use of a laboratory shelf, based on Real-Time Digital Simulator (RTDS) for testing and analysis of the protection system, is described in order to validate the correct performance in face of possible operating conditions in the field. Finally, a study case is developed using the concepts developed throughout the research. Then, the design and implementation of the protection system of generators of a hypothetical hydroelectric plant are carried out. To evaluate and analyze the performance of this example network protection system, parameterized up IED G60 (GE) and held numerous simulations in the proposed test platform.

Page generated in 0.0881 seconds